MAAVSS0007

MAAVSS0007
Voltage Variable Absorptive Attenuator
40 dB, 0.5 - 3.0 GHz
Functional Schematic 3,4,5,6
Features










Rev. V2
Single Positive Voltage Control: 0 to +5 Volts
40 dB Attenuation Range at 900 MHz
± 2 dB Linearity from BSL
Low DC Power Consumption
Tape and Reel Packaging Available
Lead-Free SOIC-8 Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
260°C Reflow Compatible
RoHS* Compliant Version of AT-108
8
7
6
5
1
2
3
4
Description
M/A-COM's MAAVSS0007 is a GaAs MESFET
MMIC voltage variable absorptive attenuator in a
lead-free SOIC-8 surface mount plastic package.
The MAAVSS0007 is ideally suited for use where
linear attenuation, fine tuning and very low power
consumption are required.
Typical applications include radio, cellular, GPS
equipment and automatic gain/level control circuits.
The MAAVSS0007 is fabricated with a monolithic
GaAs MMIC using a mature 1-micron process. The
process features full chip passivation for increased
performance and reliability.
3. Vcc = +5 VDC @ 50 µA maximum.
4. Vc = 0 VDC to +5 VDC @ 50 µA maximum.
5. External DC blocking capacitors are requirements on all RF
ports.
6. 39 pF used for data measurements.
Pin Configuration
Pin No.
Function
Pin No.
Function
1
Ground
5
VC
2
Ground
6
Ground
3
RF Port
7
RF Port
4
VCC
8
Ground
Ordering Information 1,2
Part Number
Package
MAAVSS0007
Bulk Packaging
MAAVSS0007TR
1000 piece reel
MAAVSS0007SMB
Sample Board
Absolute Maximum Ratings 7,8
Parameter
Absolute Maximum
Input Power
+21 dBm
Supply Voltage VCC
-1 V < VCC < +8 V
Control Voltage VC
-1 V < VC < VCC +0.5 V
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
1. Reference Application Note M513 for reel size information.
2. All sample boards include 5 loose parts.
7. Exceeding any one or combination of these limits may cause
permanent damage to this device.
8. M/A-COM does not recommend sustained operation near
these survivability limits.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAAVSS0007
Voltage Variable Absorptive Attenuator
40 dB, 0.5 - 3.0 GHz
Rev. V2
Electrical Specifications: TA = 25°C, Z0 = 50 Ω
Parameter
Test Conditions
Units
Min.
Typ.
Max.
Insertion Loss
0.5 - 1.0 GHz
1.0 - 3.0 GHz
dB
dB
—
—
2.5
2.6
—
3.5
Attenuation
0.5 - 1.0 GHz
1.0 - 2.0 GHz
2.0 - 3.0 GHz
dB
dB
dB
—
35
—
43
40
33
—
—
—
Flatness
(peak-to-peak)
0.5 - 1.0 GHz
1.0 - 2.0 GHz
2.0 - 3.0 GHz
dB
dB
dB
—
—
—
± 0.5
± 1.2
± 1.5
—
—
—
VSWR
0.5 - 3.0 GHz
Ratio
—
2:1
—
Trise, Tfall
10% to 90% RF, 90% to 10% RF
µS
—
15
—
Ton, Toff
50% Control to 90% RF, 50% Control to 10% RF
µS
—
25
—
Transients
In-Band
mV
—
12
—
Lead-Free SOIC-8†
†
Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAAVSS0007
Voltage Variable Absorptive Attenuator
40 dB, 0.5 - 3.0 GHz
Rev. V2
Typical Performance Curves @ 25°C
Insertion Loss vs. Frequency
Attenuation vs. Control Voltage
0
-1.6
-1.8
-10
-2.0
-20
-2.2
-30
-2.4
900 MHz
1800 MHz
2200 MHz
-40
-2.6
-50
5
4
3
2
1
0
-2.8
0.0
0.5
Control Voltage (V)
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
Return Loss vs. Control Voltage, F = 900 MHz
Return Loss vs. Control Voltage, F = 1800 MHz
0
0
-5
-5
S11 (dB)
S22 (dB)
-10
-10
-15
-15
-20
-20
-25
-25
-30
-30
S11 (dB)
S22 (dB)
-35
-35
5
4
3
2
1
5
0
4
3
2
1
0
Control Voltage (V)
Control Voltage (V)
Return Loss vs. Control Voltage, F = 2200 MHz
Maximum Attenuation vs. Frequency
0
0
-5
-10
-10
-20
-15
-20
-30
S11 (dB)
S22 (dB)
-25
-40
-30
-50
-35
5
4
3
2
Control Voltage (V)
1
0
0.5
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
3
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAAVSS0007
Voltage Variable Absorptive Attenuator
40 dB, 0.5 - 3.0 GHz
Rev. V2
Typical Performance Curves @ 25°C
1 dB Compression vs. Control Voltage, F = 900 MHz
IP3 vs. Control Voltage
35
25
400 MHz
900 MHz
30
20
25
15
20
10
15
5
10
0
5
0
-5
5
4
3
2
1
0
5
4
3
2
1
0
Control Voltage (V)
Control Voltage (V)
Attenuation vs. Temperature
Normalized to 25°C, F = 900 MHz
3
Handling Procedures
-40°C
+85°C
2
1
Please observe the following precautions to avoid
damage:
0
Static Sensitivity
-1
-2
5
4
3
2
1
0
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
Control Voltage (V)
4
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAAVSS0007
Voltage Variable Absorptive Attenuator
40 dB, 0.5 - 3.0 GHz
Rev. V2
M/A-COM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
5
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support