LD1625-C120

LD1625-C120
TECHNICAL DATA
Infrared Laser Diode
pulsed
Features
•
•
•
•
Lasing Mode Structure: single mode
Peak Wavelength : typ. 1625 nm
Optical Ouput Power: 120 mW, pulse mode
Package: 5.6 mm, flat window
Absolute Maximum Ratings (TC=25°C)
Item
CW Output Power
LD Reverse Voltage
LD Forward Current
Operating Case Temperature
Storage Temperature
Symbol
PO
Vr
Iop
TC
Tstg
Value
120
2
1200 *
0 … +60
-40 … +85
Unit
mW
V
mA
°C
°C
* DC ≤ 1%, PW ≤ 10 µs
Specifications (TC=25°C)
Item
Optical Specifications
CW Output Power
Center Wavelength
Spectral Width *
FWHM Beam Divergence
Electrical Specifications
Threshold Current
Slope Efficiency
Operating Voltage
Conditions
Symbol
Min.
Typ.
Max.
Unit
PO
100
120
-
mW
λC
1600
1625
1650
nm
Δλ
-
4
7
nm
CW, PO=40mW
Θ║
Θ┴
-
17
44
-
deg.
deg.
PW=10µs, DC=1%
CW, PO=40mW
CW, PO=40mW
Ith
η
Vop
-
45
0.3
1.0
1.9
mA
W/A
V
Iop=500mA,
PW=10µs, DC=1%
Iop=500mA,
PW=10µs, DC=1%
Iop=500mA,
PW=10µs, DC=1%
* RMS, -20 dB
The above specifications are for reference purpose only and subjected to change without prior notice.
13.09.2011
LD1625-C120
1 of 4
Package Dimensons
5.6 mm Package (Unit:mm)
Bottom View
PIN
1
2
3
4
13.09.2011
LD1625-C120
Funciton
Case, LD Anode
LD Cathode
nc
nc
2 of 4
Typical Performance Curves
Chip-level LI curve, 25°C fixture temperature
CW mode (blue), pulsed (10 µs PW, 1% DC) mode (magenda)
Chip-level far field curves, CW mode, Pop = 40 mW, 25°C fixture temperature
prependicular (blue), parallel (red)
13.09.2011
LD1625-C120
3 of 4
Chip-level spectral measurement
pulsed (10 µs PW, 1% DC) mode, 25°C fixture temperature
Safety of Laser light
•
•
Laser Light can damage the human eyes and skin. Do not expose the
eye or skin directly to any laser light and/or through optical lens. When
handling the LDs, wear appropriate safety glasses to prevent laser
light, even any reflections from entering to the eye. Focused laser
beam through optical instruments will increase the chance of eye
hazard.
The LD emitts invisible light
Cautions
1. Operating methode
• This LD shall change its forward voltage requirement and optical ouput power according to
temperature change. Also, the LD will require more operation current to maintain same ouput
power as it degrades. [In order to maintain output power, use of APC (Automatic Power
Control) is recommended. Which use monitor feedback to adjust the operation current.]
• Confirm that electrical spike current generated by switching on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handeling the product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated striclty below
absolute maximum rating.
13.09.2011
LD1625-C120
4 of 4