UVLUX270-3

v2 07/14
UVLUX270-3
► Deep Ultraviolet Light Emission Source
► 275 nm, 1-3 mW
► 4 chip LED array
►
Water Sterilization, DNA Sequencing
Description
UVLUX270-3 is a series of AlGaN based deep UV multi chip LED arrays, utilizing 4 parallel connected chip dies, with a typical peak
wavelength of 270 nm and optical output power of 1-3 mW. It comes in hermetically sealed TO39 metal can package with
hemispherical lens or flat glass window. UVLUX270-3 is widely used for forensic analysis, disinfection, water sterilization, protein
analysis, DNA sequencing and drug discovery.
Maximum Rating (T
CASE
= 25°C)
Parameter
Power Dissipation, DC*
Forward Current (TA=25°C)
Values
Symbol
Max.
Min.
PD
IF
Unit
600
mW
80
mA
Operating Temperature
TOPR
- 30
+ 55
°C
Storage Temperature
TSTG
- 30
+ 100
°C
Soldering Temperature
TSOL
+ 190
°C
* Maximum dissipated power must not exceed 200mW without thermal management
Electro-Optical Characteristics (T
CASE =
Parameter
Peak Wavelength
*1
Spectral Width (FWHM)
Forward Voltage
*2
Symbol
λP
Min.
270
∆λ
VF
25°C, IF = 80 mA)
Values
Typ.
Max.
Unit
275
280
nm
12
15
nm
6.2
7.5
V
3
mW
*3
PO
Beam Angle (hemispherical lens)
2Ө1/2
20
deg.
Beam Angle (flat window)
2Ө1/2
120
deg.
Radiated Power
1
*1wavelength measurement tolerance: ± 2 nm
2
* forward voltage measurement tolerance: ± 2 %
3
* output power measurement tolerance: ± 10 %
Electrical Connection
Bottom view:
Pin #
Function
Pin 1
Anode
Pin 2
Cathode
Pin 3
Case
www.roithner-laser.com
Electrical layout:
1
Outline Dimensions
FW - Flat window
All dimensions in mm
HL - Hemispherical lens
All dimensions in mm
Device Materials
Part
Header
Leads
Bonding wires
Lens
www.roithner-laser.com
Material
Fe-Ni alloy, plated Ni-Au
Fe-Ni alloy, plated Ni-Au
Au
SiO2
2
Emission Characteristics
FW - Flat window
HL - Hemispherical lens
www.roithner-laser.com
3
Precautions
Soldering:
•
•
•
•
•
•
•
•
•
•
Do avoid overheating of the LED
Do avoid electrostatic discharge (ESD)
Do avoid mechanical stress, shock, and vibration
Do only use non-corrosive flux.
Do only solder the leads. Soldering of header or cap will damage the LED
Do only cut the leads at room temperature with an ESD protected tool
Do not solder closer than 3 mm from base of the header
Do form leads prior to soldering
Do not impose mechanical stress on the header when forming the leads
Do not apply current to the LED until it has cooled down to room temperature after soldering
Recommended soldering conditions:
dip soldering
pre-heat time
dipping time
solder bath temperature
hand soldering
max 30 s
max 5 s
max 190 °C
soldering time
solder temperature
max 5 s
max 190 °C
It is strongly advised to perform soldering at the shortest time and lowest temperature
possible.
Cleaning:
Cleaning with isopropyl alcohol, propanol, or ethyl alcohol is recommended
DO NOT USE acetone, chloroseen, trichloroethylene, or MKS
DO NOT USE ultrasonic cleaners
Static Electricity:
UVTOP are sensitive to electrostatic discharge (ESD). Precautions against ESD must be taken when handling or
operating these LEDs. Surge voltage or electrostatic discharge can result in complete failure of the device.
UV-Radiation:
During operation these LEDs do emit high intensity ultraviolet light, which is hazardous to skin and eyes, and may
cause cancer. Do avoid exposure to the emitted UV light. Protective glasses are recommended. It is further advised
to attach a warning label on products/systems that do utilize UV-LEDs:
Class 1
Operation:
Do only operate UVTOP LEDs with a current source.
Running these LEDs from a voltage source will result in complete failure of the device.
Current of a LED is an exponential function of the voltage across it. Usage of current regulated drive circuits is