XYA Series - First Sensor

XYA Series
Oxygen sensors
FEATURES
· Oxygen pressure range 2 mbar...3 bar
· Zirconium dioxide (ZrO2) sensing elements
· Non-consumptive technology
· Integral heating element
· No need for temperature stabilisation
· No reference gas required
· Function testing and calibration in
ambient air
· High accuracy
· Linear output signal
· Operates with external interface boards
ELECTRICAL CONNECTION
SPECIFICATIONS
Maximum ratings
Stainless steel wires (XYA1S)
Heater supply voltage1
Stand by
Pump resistance @ 700 °C
4.35 ±0.1 VDC (1.85 A)
2.0 VDC (0.85 A)
2
Permissable gas temperature3
XYA1
all others
Gas flow rate
6 kΩ
-100...400 °C
-100...250 °C
P
C
H
H
S
P: Pump
C: Common
S: Sense
H: Heater
0...10 m/s
Repetitive permissable accelaration
5g
Incidental permissable accelaration
30 g
Molex connector (XYA...M)
1:
2:
3:
4:
5:
Pump (Red)
Common (Black)
Heater (Yellow)
Sense (Blue)
Heater (Yellow)
Note:
1. It is important to measure the heater voltage as close to the sensor as possible due to voltage drops in the supply cable.
The heater can also be operated with an equivalent AC or PWM signal.
2. The constant current source used in the pump circuit should be designed to drive a load of up to 6 kΩ.
3. For gas temperatures above 200 °C the heater supply voltage has to be decreased accordingly.
E / 11637 / C
1/3
www.first-sensor.com
www.sensortechnics.com
XYA Series
Oxygen sensors
PERFORMANCE CHARACTERISTICS
Characteristics
Min.
Oxygen pressure range
Typ.
Max.
2
Unit
3000
Accuracy
mbar
5
Internal operational temperature
700
Stand by temperature
500
°C
Response time (10 to 90 %)
4
Warm up time (prior to sensor operation)
100
Warm up time (from stand by)
20
s
OUTLINE DRAWING
XYA1S
Ø 12
15
16.5
Ø6
P
C
H
H S
Ø 0.64
Ni-plated stainless steel wires
mass: 4 g
dimensions in mm
XYA2M
150
80
4
Ø 12
mass: 24 g
E / 11637 / C
dimensions in mm
2/3
www.first-sensor.com
www.sensortechnics.com
XYA Series
Oxygen sensors
OUTLINE DRAWING (cont.)
XYA5M, XYA6M, XYA7M
150
80
15.5
7
5
4
Ø 12
M18 x 1.5
x
x = 28 mm for XYA5...
x = 45 mm for XYA6...
x = 55 mm for XYA7...
mass: 48 g
dimensions in mm
ORDERING INFORMATION
Series
Options
XYA
1S
Housing type
cylinder
Termination
stainless steel wires
2M
probe
Molex connector*
5M
screw fit probe, M18 x 1.5
(28 mm sensor header)
screw fit probe, M18 x 1.5
(45 mm sensor header)
screw fit probe, M18 x 1.5
(55 mm sensor header)
Molex connector*
6M
7M
Molex connector*
Molex connector*
* Molex mating connector:
39-01-2061 (plastic plug)
39-00-0041 (pins)
Example:
XYA
2M
Note: Custom specific options are available. Please contact First Sensor for further information.
First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the application
or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11637 / C
3/3
www.first-sensor.com
www.sensortechnics.com