International Linears Safety Certs

File E135803
Project 91SC05587
1991-07-15
COMPONENT – POWER SUPPLIES
INFORMATION TECHNOLOGY EQUIPMENT
INCLUDING ELECTRICAL BUSINESS EQUIPMENT
Condor DC Power Supplies, Inc.
Oxnard, California
Copyright © 1991 Underwriters Laboratories Inc.
Underwriters Laboratories Inc. authorizes the above named company to
reproduce this Report provided it is reproduced in its entirety.
Underwriters Laboratories Inc. authorizes the above-named company to
reproduce that portion of this Report consisting of this Cover Page through
Page 3.
File E135803
Vol. 1
Sec. 6
and Report
Page 1
Issued:
1991-07-15
DESCRIPTION
PRODUCT COVERED:
USR, Linear Power Supply, see model numbers listed under Electrical
Ratings. All model numbers may be followed by -XXX, where X is a digit 0
to 9.
ELECTRICAL RATINGS:
Input Ratings:
rated input current.
Model
HA15-0.9-A+
HA2-1.5-A+
HA24-0.5-A+
HA5-1.5/OVP-A+
HAA15-0.8-A+
HAA24-0.6-A+
HAA5-1.5/OVP-A+
HAA512-A+
HAA524-A+
HAD12-0.4-A+
HAD15-0.4-A+
HB12-1.7-A+
HB15-1.5-A+
HB2-3-A+
HB24-1.2-A+
HB28-1-A+
HB48-0.5-A+
HB5-3/OVP-A+
HBAA-40W-A+
HBB15-1.5-A+
HBB512-A+
HBB524-A+
HBB5-3/OVP-A+
HC12-3.4-A+
HC15-3-A+
HC24-2.4-A+
HC2-6-A+
HC28-2-A+
HC48-1-A+
HC5-6/OVP-A+
HTAA-16W-A+
100/120/215/230-240 V ac, 50/60 Hz.
Input Current
0.5/0.4/0.2/0.2 A
0.4/0.3/0.2/0.2 A
0.5/0.4/0.2/0.2 A
0.4/0.4/0.2/0.2 A
0.77/0.65/0.35/0.33
0.77/0.65/0.35/0.33
0.53/0.46/0.24/0.24
0.61/0.52/0.28/0.26
0.7/0.6/0.3/0.3 A
0.4/0.3/0.2/0.2 A
0.5/0.4/0.2/0.2 A
0.6/0.5/0.3/0.3 A
0.65/0.56/0.31/0.28
0.45/0.38/0.2/0.2 A
0.76/0.65/0.35/0.32
0.72/0.62/0.34/0.31
0.6/0.5/0.3/0.3 A
0.6/0.5/0.3/0.3 A
1.3/1.1/0.6/0.6 A
1.4/1.2/0.7/0.6 A
1.2/1.0/0.6/0.5 A
1.2/1.1/0.6/0.5 A
1.0/0.9/0.5/0.5 A
1.2/1.0/0.6/0.5 A
1.3/1.1/0.6/0.6 A
1.4/1.2/0.7/0.6 A
0.9/0.8/0.4/0.4 A
1.4/1.2/0.7/0.6 A
1.1/1.0/0.5/0.5 A
1.1/0.9/0.5/0.5 A
0.7/0.6/0.3/0.3 A
A
A
A
A
A
A
A
See below for
File E135803
Vol. 1
Sec. 6
and Report
Page 2
Issued:
Revised:
V2
A2
-12 to 15
-18 to 24
-5
9 to 15
18 to 24
-12
-15
1.0/0.8
0.4/0.6
1.5
0.5
0.3
0.4
0.4
+12/15
-12/15
+9 to 15
+18 to 24
-5
+9 to 15
1991-07-15
2003-01-31
Output Ratings:
Model
HA15-0.9-A+
HA2-1.5-A+
HA24-0.5-A+
HA5-1.5/OVP-A+
HAA15-0.8-A+
HAA24-0.6-A+
HAA5-1.5/OVP-A+
HAA512-A+
HAA524-A+
HAD12-0.4-A+
HAD15-0.4-A+
HB12-1.7-A+
HB15-1.5-A+
HB2-3-A+
HB24-1.2-A+
HB28-1-A+
HB48-0.5-A+
HB5-3/OVP-A+
HBAA-40W-A+
HBB15-1.5-A+
HBB512-A+
HBB524-A+
HBB5-3/OVP-A+
HC12-3.4-A+
HC15-3-A+
HC24-2.4-A+
HC2-6-A+
HC28-2-A+
HC48-1-A+
HC5-6/OVP-A+
HTAA-16W-A+
V1
12/15
2
24/28
5
12/15
+18 to 24
+5
5
5
+12
+15
12
15
2
24
28
48
5
5
+12/15
5
5
+5
12
15
24
2
28
48
5
5
A1
0.9
1.5
0.5
1.5
1.0/0.8
0.4/0.6
1.5
2.0
2.0
0.4
0.4
1.7
1.5
3.0
1.2
1.0
0.5
3.0
3.0
1.7/1.5
3.0
3.0
3.0
3.4
3.0
2.4
6.0
2.0
1.0
6.0
2.0
V3
A3
1/0.8
1.7/1.5
1.25
0.8
3.0
-12/15/5
1/0.8/0.4
0.4
-9 to 15
or –5
0.4
ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE):
This product is for use only in (or with) complete equipment where the
acceptability of the combination is determined by Underwriters Laboratories
Inc.
*
USR/CNR indicates investigation to the U.S. and Canadian (BiNational) Standard for Safety of Information Technology Equipment, CSAC22.2 No. 60950-00 ♦ UL 60950, Third Edition.
The equipment is for building in, Class I (earthed), for use on a TN
power system.
File E135803
Vol. 1
Sec. 6
and Report
Page 3
Issued:
Revised:
1991-07-15
2003-01-31
Conditions of Acceptability - When installed in the end-use equipment,
the following are among the considerations to be made:
1.*
This component has been judged on the basis of the required spacings
in the Standard for Information Technology Equipment, Including
Electrical Business Equipment, CSA-C22.2 No. 60950-00 ♦ UL 60950,
Third Edition, which would cover the component itself if submitted
for unrestricted listing.
2.
All secondary output circuits on all models except HAA24-0.6-A+,
HB48-0.5-A+ and HC48-1-A+ are SELV and are not hazardous energy
levels.
3.
The terminals and connectors have not been evaluated for field
wiring.
4.*
The power supply shall be properly bonded to the main protective
earthing termination in the end product as this unit was investigated
for Class I construction as defined in UL 60950. An additional
evaluation shall be made if the power supply is intended for use in
other than Class I equipment.
5.
Bonding terminals provided on this equipment have not been evaluated
as protective earthing terminals.
6.
Magnetic device transformer T1 employs an OBJY2 electrical insulation
system designated Class F.
7.
The equipment has been evaluated for use in a Pollution Degree 2
environment.
8.
The component shall be installed in compliance with the enclosure,
mounting, spacing, casualty markings and segregation requirements of
the end-use application.
9.
This power supply was evaluated for use in a 50°C ambient. An
additional evaluation should be made if the power supply is intended
to be used in an elevated ambient.
10.
These power supplies were tested with a UL Listed external input line
fuse. The fuse ratings used are as described in Illustration 3. An
additional evaluation should be made if an input line fuse greater
than that specified is to be used in the end product.
File E135803
Project 91SC12647
1991-10-15
REPORT
on
COMPONENT – POWER SUPPLIES
INFORMATION TECHNOLOGY EQUIPMENT
INCLUDING ELECTRICAL BUSINESS EQUIPMENT
Condor DC Power Supplies, Inc.
Oxnard, California
Copyright © 1991 Underwriters Laboratories Inc.
Underwriters Laboratories Inc. authorizes the above named company to
reproduce this Report provided it is reproduced in its entirety.
Underwriters Laboratories Inc. authorizes the above-named company to
reproduce that portion of this Report consisting of this Cover Page through
Page 3.
File E135803
Vol. 1
Sec. 9
and Report
Page 1
Issued:
Revised:
1991-10-15
2004-06-18
DESCRIPTION
PRODUCT COVERED:
USR – Component - Linear Power Supplies for use in Information
Technology Equipment, A+ Series, see model numbers listed under Electrical
Ratings. All model numbers may be followed by XXX, where X is a digit 0 to
9.
USR/CNR – Model CP1803.
ELECTRICAL RATING:
Model
*
HD12-6.8-A+
HD15-6-A+
HD2-12-A+
HD24-4.8-A+
HD28-4-A+
HD5-12/OVP-A+
HN12-5.1-A+
HN15-4.5-A+
HN2-9-A+
HN24-3.6-A+
HN28-3-A+
HN5-9/OVP-A+
* HD48-3-A+
CP1413
CP1803
Input Current
100/120/215/230-240 V
2.8/2.4/1.3/1.2 A
2.8/2.4/1.3/1.2 A
1.5/1.3/0.7/0.7 A
2.8/2.4/1.3/1.2 A
2.5/2.1/1.2/1.1 A
2.3/1.9/1.0/1.0 A
1.7/1.5/0.8/0.8 A
1.7/1.5/0.8/0.8 A
2.0/1.7/0.9/0.9 A
2.1/1.8/0.9/0.9 A
2.0/1.7/0.9/0.9 A
1.6/1.3/0.7/0.7 A
3/2.6/1.4/1.3 A
2.1/1.8/0.9/0.9 A
2.0/1.7/1.0/0.9 A
Output Ratings
12 V, 6.8 A
15 V, 6 A
2 V, 12 A
24 V, 4.8 A
28 V, 4 A
5 V, 12 A
12 V, 5.1 A
15 V, 4.5 A
2 V, 9 A
24 V, 3.6 A
28 V, 3 A
5 V, 9 A
48 V, 2.5 A with 14 cfm fan 48 V, 3 A
24 V, 3.6 A
5 V, 8 A, 5 V, 2 A
File E135803
Vol. 1
Sec. 9
and Report
Page 2
Issued:
Revised:
1991-10-15
2004-06-18
ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE):
*
USR/CNR indicates investigation to the U.S. and Canadian (BiNational) Standard for Safety of Information Technology Equipment, CSAC22.2 No. 60950-00 ♦ UL 60950, Third Edition.
Conditions of Acceptability - When installed in the end-use
equipment, considerations shall be given to the following:
1.
This component has been judged on the basis of the required spacings
in the Standard for Information Technology Equipment, Subclause 2.9,
which would cover the component itself if submitted for unrestricted
Listing.
2.
This power supply shall be installed in compliance with the
enclosure, mounting, creepage, clearance, casualty, markings and
segregation requirements of the end-use application.
3.
The need for conducting leakage current tests is to be determined as
part of the end-product evaluation.
4.
This power supply has only been evaluated for use in a pollution
degree 2 environment.
5.
All transformers employ a min. Class B (130°C) electrical insulation
system. Transformer for CP1803 has a Class F (155°C) insulation
system.
6.
The input and output connectors have not been evaluated for field
connections and are only intended for connection to mating connectors
of internal wiring inside the end-use machine. The acceptability of
these and the mating connectors relative to secureness, insulating
materials, and temperature shall be considered. Models provided with
suffix "XXX" may be provided with Wiring Harnesses.
File E135803
Vol. 1
Sec. 9
and Report
Page 3
Issued:
Revised:
1991-10-15
2004-06-18
7.
This power supply shall be properly bonded to earth in the end-use
product as this unit was investigated for Class I construction as
defined in CSA-C22.2 No. 60950-00 ♦ UL 60950. The bonding terminal
has not been investigated as a protective earthing terminal. An
additional evaluation shall be made if the power supply is intended
for use in other than Class I equipment.
8.
All secondary outputs of these power supplies are considered SELV,
except for the 48 V dc outputs.
9.
This power supply was evaluated under the assumption that the power
source is a TN-S system as defined by CSA-C22.2 No. 60950-00 ♦
UL 60950.
10.
This power supply has been evaluated for use in a 25°C and a 50°C
ambient.
11.
The end use product shall provide a primary fuse and the fuse
replacement marking. See Ill. 2 for fuse values.
File E135803
Project 92SC18124
1993-02-26
COMPONENT – POWER SUPPLIES
INFORMATION TECHNOLOGY EQUIPMENT
INCLUDING ELECTRICAL BUSINESS EQUIPMENT
Condor DC Power Supplies, Inc.
Oxnard, California
Copyright © 1993 Underwriters Laboratories Inc.
Underwriters Laboratories Inc. authorizes the above named company to
reproduce this Report provided it is reproduced in its entirety.
Underwriters Laboratories Inc. authorizes the above-named company to
reproduce that portion of this Report consisting of this Cover Page through
Page 4.
File E135803
Vol. 1
Sec. 18
and Report
Page 1
Issued:
1993-02-26
DESCRIPTION
PRODUCT COVERED:
Component - Linear Power Supplies for use in Information Technology
Equipment, Models F5-25/OVP-A+, HDBB-105W-A+, HDD15-5-A+, HE2-18-A+, HE518/0VP-A+, HE12-10.2-A+, HE15-9-A+, HE24-7.2-A+, HE28-6-A+, and HE48-4-A+.
65
ELECTRICAL RATINGS:
Input:
Model
F5-25/OVP-A+
HDBB-105W-A+
HDD15-5-A+
HE2-18-A+
HE5-18/OVP-A+
HE12-10.2-A+
HE15-9-A+
HE24-7.2-A+
HE28-6-A+
HE48-4-A+
Voltage
100/120/215/230-240
100/120/215/230-240
100/120/215/230-240
100/120/215/230-240
100/120/215/230-240
100/120/215/230-240
100/120/215/230-240
100/120/215/230-240
100/120/215/230-240
100/120/215/230-240
Current
3.8/1.6
3.0/1.3
3.4/1.5
2.2/0.9
2.9/1.2
3.3/1.4
3.7/1.5
3.9/1.6
3.6/1.5
4.0/1.7
Frequency
47
47
47
47
47
47
47
47
47
47
-
63
63
63
63
63
63
63
63
63
63
File E135803
Vol. 1
Sec. 18
and Report
Page 2
Issued:
Revised:
1993-02-26
2003-02-10
Output:
Model
F5-25/OVP-A+
HDBB-105W-A+
V1
A1
V2
5
5
25
12
12
15
-15
-
or
HDD15-5-A+
HE2-18-A+
HE5-18/OVP-A+
HE12-10.2-A+
HE15-9-A+
HE24-7.2-A+
HE28-6-A+
HE48-4-A+
15
2
5
12
15
24
28
48
5
18
18
10.2
9
7.2
6
4
A2
1.7
1.5
5
-
V3
A3
-12
-15
-
1.7
1.5
-
ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE):
*
This product was investigated under the Standard for Information
Technology Equipment, UL 60950, Third Edition.
Conditions of Acceptability - When installed in the end-use
equipment, considerations shall be given to the following:
1.
These components have been judged on the basis of the required
spacings in the Standard for Information Technology Equipment, SubClause 2.9, which would cover the components themselves if submitted
for unrestricted Listing.
2.
These power supplies shall be installed in compliance with the
enclosure, mounting, creepage, clearance, casualty, markings, and
segregation requirements of the end-use application.
File E135803
Vol. 1
Sec. 18
and Report
Page 3
Issued:
1993-02-26
3.
The need for conducting leakage current tests is to be determine as
part of the end-product evaluation.
4.
This power supply has only been evaluated for use in a pollution
degree 2 environment.
5.
Consideration should be given to conducting a Heating Test in the end
product; as a 14 CFM Fan was used with testing. Consideration should
be given to measuring the temperature on power electronic components,
inductors, and transformer windings when the power supply is
installed in the end-use equipment. All transformers employ a Class
130 electrical insulation system.
6.
The input and output connectors have not been evaluated for field
connections and are only intended for connection to mating connectors
of internal wiring inside the end-use machine. The acceptability of
these and the mating connectors relative to secureness, insulating
materials, and temperature shall be considered.
7.
This power supply shall be properly bonded to earth in the end-use
product as this unit was investigated for Class I construction as
defined in UL 60950. The bonding terminal has not been investigated
as a protective earthing terminal. An additional evaluation shall be
made if the power supply is intended for use in other than Class I
equipment.
8.
The secondary outputs of this power supply are considered SELV.
9.
This power supply was evaluated under the assumption that the power
source is a TN-S system as defined by
UL 1950.
10.
This power supply has been evaluated for use in a 25°C and a 50°C
ambient.
File E135803
Vol. 1
Sec. 18
and Report
Page 4
Issued:
1993-02-26
11.
The voltage selector jumper has not been evaluated for current
interruption while the unit is under load.
12.
The power supply, Model HE48-4-A+, has outputs which exceed 240 VA at
a potential of 2 V or more. Therefore, the accessibility of these
circuits should be considered when installed in the end-use product.
13.
This power supply is provided with overcurrent protection in one side
of the line. Consideration should be given to protecting both sides
of the line if one side of the line is not a neutral conductor.
14.
The isolating transformer T1, employs Recognized Component Insulation
Systems (OBJY2), designated
Class 130.
Issue Date:
2003-10-31
Correction 1
2003-11-04
Page 1 of 1
Report Reference #
E135803-A1-UL-1
COVER PAGE FOR TEST REPORT
Product Category:
Power Supplies for Information Technology Equipment Including Electrical
Business Equipment
QQGQ2, QQGQ8
Component Recognition
Power Supplies
HA15-0.9-A+, HA2-1.5-A+, HA24-0.5-A+, HA5-1.5/OVP-A+, HB12-1.7-A+,
HB15-1.5-A+, HB2-3-A+, HB24-1.2-A+, HB28-1-A+, HB5-3/OVP-A+, HC123.4-A+, HC15-3-A+, HC2-6-A+, HC24-2.4-A+, HC28-2-A+, HC5-6/OVP-A+,
and HD12-6.8-A+, HD15-6-A+, HD2-12-A+, HD24-4.8-A+ , HD28-4-A+, HD512/OVP-A+, HN12-5.1-A+ , HN15-4.5-A+ , HN2-9-A+, HN24-3.6-A+, HN28-3A+ , HN5-9/OVP-A+, HE12-10.2-A, HE15-9-A, HE2-18-A, HE24-7.2-A, HE286-A, and HE5-18-OV-A.
100/120/215/230-240 V~, 50/60 Hz, for current ratings, see General Product
Information.
UL 60950-1:2003, First Edition
Product Category CCN:
Test Procedure:
Product:
Model/Type Reference:
Rating(s):
Standards:
Applicant Name and Address: CONDOR D C POWER SUPPLIES INC
2311 STATHAM PKY
OXNARD CA 93033
This Report includes the following parts, in addition to this cover page:
1. Specific Technical Criteria
2. National Differences
This is to certify that representative samples of the products covered by this Test Report have been investigated by Underwriters
Laboratories Inc. ('UL') in accordance with the above referenced Standards. The products have been found to comply with the
requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure.
The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable
requirements of UL in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are
considered as being covered by UL's Follow-Up Service under the indicated Test Procedure.
UL authorizes the applicant to reproduce the referenced Test Report provided it is reproduced in its entirety.
UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific
Technical Criteria through to the end of the Conditions of Acceptability.
Test Report By:
Reviewed By:
Ahmad Daoudi
Engineering Project Handler
Robert Hilbrecht
Senior Staff Engineer
Underwriters Laboratories Inc.
Copyright © 2002 Underwriters Laboratories Inc.
Issue Date:
2006-12-07
Page 1 of 2
Report Reference #
E135803-A35-UL-1
COVER PAGE FOR TEST REPORT
Product Category:
Product Category CCN:
Test Procedure:
Product:
Model/Type Reference:
Rating(s):
Standards:
Power Supplies for Information Technology Equipment Including Electrical
Business Equipment
QQGQ2, QQGQ8
Component Recognition
Built-in Power Supply, AC/DC
CP131-A+, CP323-A+, HAA15-0.8-A+, HAA24-0.6-A+, HAA5-1.5-OV-A+,
HAA512-A+, HAA524-A+, HAD12-0.4-A+, HAD15-0.4-A+, HBAA40W-A+,
HBB15-1.5-A+, HBB512-A+, HBB524-A+, HBB5-3-OV-A+, HCAA60W-A+,
HCBB105W-A+, HCBB75W-A+, HCC15-3-A+, HCC512-A+, HCC524-A+,
HCC5-6-OV-A+, HDBB105W-A+, HDCC150W-A+, HDD15-5-A+, HTAA-16WA+, CP1803. Models may be followed by suffix G to indicate compliance to
RoHS. (RoHS compliance has not been evaluated by UL)
100/120/215/230-240 V~, 50/60 Hz, for current ratings, see General Product
Information.
UL 60950-1:2003, First Edition
CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003
Applicant Name and
Address:
SL POWER ELECTRONICS CORP
6050 KING ST
VENTURA CA 93003
This Report includes the following parts, in addition to this cover page:
1. Specific Inspection Criteria
2. Specific Technical Criteria
3. Clause Verdicts
4. Critical Components
5. Test Results
6. National Differences
7. Enclosures
Copyright © 2006
Issue Date:
2006-12-07
Page 2 of 2
Report Reference #
E135803-A35-UL-1
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in
accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being
covered by UL's Follow-Up Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific
Technical Criteria through to the end of the Conditions of Acceptability.
Any information and documentation provided to you involving UL Mark services are provided on behalf of Underwriters Laboratories
Inc(ULI) or any authorized license of ULI.
Test Report By:
Reviewed By:
Ahmad Daoudi
Engineering Project Handler
Underwriters Laboratories Inc.
Robert Hilbrecht
Staff Engineer
Underwriters Laboratories Inc.
Copyright © 2006
Issue Date:
2006-12-07
Page 1 of 57
Report Reference #
E135803-A35-UL-1
SPECIFIC INSPECTION CRITERIA
BA1.0
Special Instructions to UL Representative
BA1.1
N/A
BB1.0
Supporting Documentation
BB1.1
The following documents located at the beginning of this Procedure supplement the requirements
of this Test Report:
A. Authorization - The Authorization page may include additional Factory Identification Code
markings.
B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this
Procedure. Products described in this Test Report must comply with any applicable items
listed unless otherwise stated in the body of this Test Report.
ii. Part AE details any requirements which may be applicable to all products covered by this
Procedure. Products described in this Test Report must comply with any applicable items
listed unless otherwise stated in the body of each Test Report.
iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the
technical standard used to investigate these products. Products are permitted to bear only
the Certification Mark(s) corresponding to the countries for which it is certified, as indicated
in each Test Report.
BC1.0
Markings and instructions
BC1.1
The following markings and instructions are provided as indicated.
BC1.2
All clause references are from UL 60950-1:2003, First Edition.
Standard
Clause
Clause Title
Marking or Instruction Details
1.7
Safety
Instructions Rack Mount
"Rack Mount Instructions - The following or similar rack-mount instructions are
included with the installation instructions:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not
compromised.
C) Mechanical Loading - Mounting of the equipment in the rack should be
such that a hazardous condition is not achieved due to uneven mechanical
loading.
Underwriters Laboratories Inc.
Issue Date:
2006-12-07
Page 2 of 57
Report Reference #
E135803-A35-UL-1
D) Circuit Overloading - Consideration should be given to the connection of
the equipment to the supply circuit and the effect that overloading of the
circuits might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when
addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be
maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (e.g. use of power strips)."
1.7.1
Power rating Ratings
Ratings (voltage, frequency/dc, current)
Power rating Model
Model Number
BD1.0
Production-Line Testing Requirements
BD1.1
Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for
further information.
Test
Potential
Model
Component
Removable Parts
Test probe location
N/A
N/A
N/A
N/A
BD1.2
Earthing Continuity Test Exemptions - This
test is not required for the following models:
N/A
BD1.3
Electric Strength Test Exemptions - This test
is not required for the following models:
N/A
BD1.4
Electric Strength Test Component
Exemptions - The following solid-state
components may disconnected from the
remainder of the circuitry during the
performance of this test:
N/A
BE1.0
Sample and Test Specifics for Follow-Up Tests at UL
BE1.1
Model
N/A
Component
N/A
Material
N/A
Test
N/A
Underwriters Laboratories Inc.
V
Test
rms V dc Time, s
N/A
Sample(s)
N/A
N/A
N/A
Test
Specifics
N/A
Issue Date:
2006-12-07
Page 3 of 57
Report Reference #
E135803-A35-UL-1
SPECIFIC TECHNICAL CRITERIA
UL 60950-1, First Edition
Information technology equipment - SafetyPart 1: General Requirements
Report Reference No ........................: E135803-A35-UL-1
Compiled by .....................................: Ahmad Daoudi
Reviewed by ....................................: Robert Hilbrecht
Date of issue ....................................: 2006-12-07
Standards .........................................: UL 60950-1:2003, First Edition
CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003
Test procedure .................................: Component Recognition
Non-standard test method ...............: N/A
Test item description .......................: Built-in Power Supply, AC/DC
Trademark ........................................:
Model and/or type reference ............: CP131-A+, CP323-A+, HAA15-0.8-A+, HAA24-0.6-A+, HAA5-1.5-OVA+, HAA512-A+, HAA524-A+, HAD12-0.4-A+, HAD15-0.4-A+,
HBAA40W-A+, HBB15-1.5-A+, HBB512-A+, HBB524-A+, HBB5-3OV-A+, HCAA60W-A+, HCBB105W-A+, HCBB75W-A+, HCC15-3-A+,
HCC512-A+, HCC524-A+, HCC5-6-OV-A+, HDBB105W-A+,
HDCC150W-A+, HDD15-5-A+, HTAA-16W-A+, CP1803. Models may
be followed by suffix G to indicate compliance to RoHS. (RoHS
compliance has not been evaluated by UL)
Rating(s) ...........................................: 100/120/215/230-240 V~, 50/60 Hz, for current ratings, see General
Product Information.
Particulars: test item vs. test requirements
Equipment mobility .................................................... : for building-in
Operating condition ................................................... : continuous
Mains supply tolerance (%) ....................................... : +6%, -10%
Tested for IT power systems ..................................... : Yes, considered
IT testing, phase-phase voltage (V) .......................... : 230
Class of equipment ................................................... : Class I (earthed)
Mass of equipment (kg) ............................................ : See table under General Product Information
Protection against ingress of water ........................... : IP X0
Underwriters Laboratories Inc.
Issue Date:
2006-12-07
Page 4 of 57
Report Reference #
E135803-A35-UL-1
Possible test case verdicts:
- test case does not apply to the test object ............. : N / A
- test object does meet the requirement ................... : Pass
- test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent
national requirement is "Pass")
General remarks:
- "(see Enclosure #)" refers to additional information appended to the Test Report
- "(see appended table)" refers to a table appended to the Test Report
- Throughout the Test Report a point is used as the decimal separator
Underwriters Laboratories Inc.
Issue Date:
2006-12-07
Page 5 of 57
Report Reference #
E135803-A35-UL-1
GENERAL PRODUCT INFORMATION:
CA1.0
Report Summary
CA1.1
N/A
CB1.0
Product Description
CB1.1
This product is a component linear power supply intended to be built into an end product. It is
provided with input/output terminals for internal wiring to the end use equipment.
CC1.0
Model Differences
CC1.1
All models are similar except for the transformer construction and output ratings.
CD1.0
Additional Information
CD1.1
INPUT CURRENT RATINGS - Amps
Model
100V
120V
CP131-A+
2.3
2.0
CP323-A+
1.7
1.4
HAA15-0.8-A+
0.77
0.65
HAA24-0.6-A+
0.77
0.65
HAA5-1.5-OV-A+ 0.53
0.46
HAA512-A+
0.61
0.52
HAA524-A+
0.7
0.6
HAD12-0.4-A+
0.5
0.4
HAD15-0.4-A+
0.5
0.4
HBAA40W-A+
1.3
1.1
HBB15-1.5-A+
1.4
1.2
HBB512-A+
1.2
1.0
HBB524-A+
1.2
1.1
HBB5-3-OV-A+
1.0
0.9
HCAA60W-A+
3.0
2.8
HCBB105W-A+
2.7
2.2
HCBB75W-A+
2.3
2.0
HCC15-3-A+
2.4
1.9
HCC512-A+
2.5
2.2
HCC524-A+
2.4
2.0
HCC5-6-OV-A+
2.0
1.7
HDBB105W-A+
3.0
2.5
HDCC150W-A+
4.4
3.8
HDD15-5-A+
3.4
2.9
HTAA-16W-A+
0.7
0.6
CP1803
2.0
1.7
Model
CP131-A+
-5 V 0.7 A
CP323-A+
Case Code
NBB
B
215V
1.1
0.8
0.35
0.35
0.24
0.28
0.3
0.2
0.2
0.6
0.7
0.6
0.6
0.5
1.5
1.2
1.1
1.0
1.2
1.2
1.0
1.4
2.1
1.6
0.3
1.0
230-240V
1.0
0.7
0.33
0.33
0.24
0.26
0.3
0.2
0.2
0.6
0.6
0.5
0.5
0.5
1.4
1.1
1.0
1.0
1.1
1.0
0.9
1.3
1.9
1.5
0.3
0.9
Output Ratings
5 V 9 A; +12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or -15 V 1.5 A or
12 V 4 A; 5 V 2 A
Underwriters Laboratories Inc.
Issue Date:
2006-12-07
HAA15-0.8-A+
HAA24-0.6-A+
HAA5-1.5/OVP-A+
HAA512-A+
HAA524-A+
HAD12-0.4-A+
HAD15-0.4-A+
HBAA40W-A+
V 0.4 A
HBB15-1.5-A+
A
HBB512-A+
HBB524-A+
HBB5-3/OVP-A+
HCAA60W-A+
V 0.4 A
HCBB105W-A+
V1A
Page 6 of 57
Report Reference #
E135803-A35-UL-1
AA
AA
AA
AA
AA
B
B
BAA
+12 V 1 A or +15 V 0.8 A; -12 V 1 A or -15V 0.8 A or -5 V 0.4 A
±24 V 0.6 A
±5 V 1.5 A
5 V 2 A; 9-15 V 0.5 A
5 V 2 A; 18-24 V 0.3 A
±12 V 0.4 A
±15 V 0.4 A
5 V 3 A; +12 V 1 A or +15 V 0.8 A; -12 V 1 A or -15 V 0.8 A or -5
BB
+12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or -15 V 1.5 A or -5 V 0.7
BB
BB
BB
D
5 V 3 A; 9-15 V 1.25 A
5 V 3 A; 18-24 V 0.8 A
±5 V 3 A
5 V 6 A; +12 V 1 A or +15 V 0.8 A; -12 V 1 A or -15 V 0.8 A or -5
CBB
5 V 3 A; +12 V 2.5 A or +15 V 2 A; -12 V 2.5 A or -15 V 2 A or -5
(+12 V 3.4 A or +15 V 3 A; -12 V 3.4 A or -15 V 3 A or -5 V 1.5 A
with 14cfm
HCBB75W-A+
-5 V 0.7 A
HCC15-3-A+
HCC512-A+
HCC524-A+
HCC5-6/OVP-A+
HTAA-16W-A+
CP1803
CBB
airflow)
5 V 6 A; +12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or -15 V 1.5 A or
CC
CC
CC
CC
AA
D
+12 V 3.4 A or +15 V 3 A; -12 V 3.4 A or -15 V 3 A or -5 V 1.4 A
5 V 4 A (6 A with 14 cfm airflow); 9-15 V 2.5 A
5 V 4 A (6 A with 14 cfm airflow); 18-24 V 2 A
±5 V 4 A (6 A with 14 cfm airflow)
5 V 2 A; +9-15 V 0.4 A; -9 to -15 V 0.4 A or -5 V 0.4 A
5 V 8 A; 5 V 2 A
Mass of equipment (kg):
Case Code
Weight kg
AA, B
0.9
BB
1.8
BAA
2.3
CC
3.2
D
3.4
CBB
3.6
NBB
5.4
The schematics for these models are kept in file at the CB Testing Laboratory mentioned in the
first page of this test report, and can be provided by the manufacturer upon request by
CBTLs/NCBs.
CE1.0
Technical Considerations
CE1.2
The product was submitted and tested for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 50°C
CE1.4
The product is intended for use on the following power systems: TN, IT
CE1.7
The product was investigated to the following additional standards: EN 60950-1:2001 (which
includes all European national differences, including those specified in this test report).
Underwriters Laboratories Inc.
Issue Date:
2006-12-07
Page 7 of 57
Report Reference #
E135803-A35-UL-1
CE1.14
The following are available from the Applicant upon request: Installation (Safety) Instructions /
Manual
CF1.0
Engineering Conditions of Acceptability
CF1.1
For use only in or with complete equipment where the acceptability of the combination is
determined by Underwriters Laboratories Inc.
When installed in an end-product, consideration must be given to the following:
CF1.5
The following secondary output circuits are SELV: All secondary output circuits on all models
except the 48 Vdc outputs and Models HAA24-0.6-A+ are SELV and are not hazardous energy
levels.
CF1.7
The following secondary output circuits are at non-hazardous energy levels: All secondary output
circuits on all models except the 48 Vdc outputs and Models HAA24-0.6-A+ are not hazardous
energy levels.
CF1.11
The power supply terminals and/or connectors are: Not investigated for field wiring
CF1.13
The investigated Pollution Degree is: 2
CF1.15
Proper bonding to the end-product main protective earthing termination is: Required
CF1.16
An investigation of the protective bonding terminals has: Not been conducted
CF1.18
The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2
insulation system with the indicated rating greater than Class A (105°C): All transformers are
(Class F, 155°C)
CF1.19
The following end-product enclosures are required: Mechanical, Electrical, Fire
CF1.23
The equipment is suitable for direct connection to: AC mains supply
CF2.0
The power supply shall be installed in compliance with the enclosure, mounting, spacing,
casualty and segregation requirements of the end-use application.
CF2.1
This power supplies were evaluated for use in a 25 or 50°C ambient. An additional evaluation
should be made if the power supply is intended to be used in an elevated ambient.
CF2.2
Consideration should be given to conducting a Heating Test in the end product; as a 14 cfm fan
was used for models HDBB-105W-A+ and HDD15-5-A+, and a 35 cfm fan was used for model
HDCC-150W-A+ when tested. Consideration should be given to measuring the temperature on
power electronic components, inductors, and transformer windings when the power supply is
installed in the end-use equipment.
CF2.3
The input/output terminals have not been evaluated for field connection and are only intended for
internal wiring inside the end-use product. The acceptability of this and secureness, insulating
materials, and temperature shall be considered in the end-product evaluation.
CF2.4
All tests were conducted with an external R/C fuse, rated per external fuse value marked on the
chassis and a 20 A external circuit breaker.
CF2.5
The product input and output are isolated from each other by Reinforced insulation.
CF2.6
The PWB is rated minimum 130°C.
CF2.7
Installation Instructions can be found on the SL Power Electronics Corp. website at
www.slpower.com or can be requested by writing to "SL Power Electronics Corp., 6050 King
Drive, Bldg. A, Ventura, CA 93003, U.S.A."
CF2.8
The need for conducting Touch Current Tests is to be determined as part of the end-product
evaluation.
Underwriters Laboratories Inc.
Issue Date:
2006-12-07
Page 8 of 57
Report Reference #
E135803-A35-UL-1
CF2.9
The voltage selector jumper has not been evaluated for current interruption.
CF3
Consideration should be given to protecting both sides of the line if one side of the line is not a
neutral conductor.
CF3.1
The end use product shall provide a primary fuse and the fuse replacement marking.
Underwriters Laboratories Inc.