GLC65 Single Instructions

GLC65 SERIES
INSTALLATION INSTRUCTIONS
CONDOR DC POWER SUPPLIES INC.
2311 STATHAM PKWY
OXNARD, CA 93033 + 805-486-4565
Internet: www.condorpower.com
MODEL NUMBERS: GLC65-X, where X is 5 or any number from 12 through 48, which represents the output voltage
rating. May be followed by suffix –C to indicate optional chassis/cover and/or suffix –XXX where XXX may be any number
from 001 thru 999 to indicate value added configurations that have no impact on safety and/or suffix G to indicate compliance
to RoHS.
RATINGS:
Input: 100-240 V ac, 1.5 A, 50/60 Hz
Output: 11 A or 65 W maximum or see table for standard output voltage models.
Model
Output
Watts
GLC65-5
GLC65-12
GLC65-15
GLC65-24
GLC65-28
GLC65-48
+5.1 V dc 11 A2
+12 V dc 5.4 A
+15 V dc 4.3 A
+24 V dc 2.7 A
+28 V dc 2.3 A
+48 V dc 1.35 A
562
65
65
65
65
65
Notes:
1. Maximum ambient temperature for rated output current is 50 °C.
2. Output rating at 11 A (56 W) requires 50 LFM airflow or derate to 9 A (46 W) maximum with convection cooling.
3. Maximum Operating Relative Humidity 96 %, no condensation.
4. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole responsibility that all
models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions
of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable
requirements of UL 60950-1, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, and IEC 60950-1. They are certified for Pollution
Degree 2 environment and Class I TN-S power systems. All DC outputs are SELV under normal and single fault conditions.
GROUNDING: The ground connection (quick connect tab) must be bonded to protective earth in the host equipment. Using
this terminal for the system ground is not recommended. A separate dedicated grounding point should be used.
SPACINGS: The required creepage and clearance distances from primary circuits to ground and secondary circuits must be
maintained after installation to preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety
components, as defined in the applicable safety standards, must not be exceeded
after installation to preserve the intended safety. The output power, ambient air
temperature and the availability, amount, direction and/or restriction of airflow
influence the temperatures of these components.
WARNING! RISK OF FIRE! A blown internal fuse is an indication of
catastrophic failure of circuit component(s). Refer to fuse marking on the supply for
rating. Repair must be performed by Condor authorized personnel.
WARNING! SHOCK HAZARD! Dangerous voltages are present on some
components, printed wiring traces and heatsinks.
CONNECTIONS
J1 Pin
AC Input
1
3
Line
Neutral
J3 Pin
1
2
+ Sense
- Sense
J2 Pin
1
2
3
4
5
6
DC Output
Output (+)
Output (+)
Output (+)
Return
Return
Return
EXPLANATION OF SYMBOLS
Alternating Current
Direct Current
Attention, Consult
Accompanying Documents
Attention, Dangerous Voltages
Earth (Ground)
MATING CONNECTORS
J1
J2
J3
Amp Housing 640250-3 Contact 770476-1
Amp Housing 640250-6 Contact 770476-1
Amp MTA-100 Receptacle
CAUTION: Do not exceed 5 A per pin on J2.
Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other
than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA,
and EN/IEC safety standard
41-34667-0001 Rev F 11/18/05