international + series installation instructions

SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
INTERNATIONAL + SERIES
INSTALLATION INSTRUCTIONS
RATINGS:
Input:
100/120/215/230-240 V ac, 50/60 Hz, Refer to chassis marking for input current ratings.
Output:
Model
Output Ratings at 25°C Ambient With Airflow Specified - See Notes
Airflow
Level
Notes
CP197-A+
F5-25/OVP-A+
F15-15-A+
F24-12-A+
F48-6-A+
G5-35/OVP-A+
HDBB105W-A+
HDCC150W-A+
HDD15-5-A+
HE12-10.2-A+
HE15-9-A+
HE2-18-A+
HE24-7.2-A+
HE28-6-A+
HE48-4-A+
HE5-18/OVP-A+
35 cfm
14 cfm
35 cfm
35 cfm
35 cfm
35 cfm
26 cfm
35 cfm
14 cfm
14 cfm
14 cfm
14 cfm
14 cfm
14 cfm
14 cfm
14 cfm
L5
L3M1
L5
L5
L1
L5
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L1
L3M1
2,4,6
2,3
2,3,5
2,4,6
2,4,7
2,3,5
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3,8
2,3
Notes:
1.
2
3.
4.
5.
6.
7.
8.
9.
10.
5 V 50 A (derate to 44 A at 50 °C)
5 V 25 A
12 V 16 A or 15 V 15 A
24 V 12 A (derate to 10 A at 50 °C) or 28 V 10 A (derate to 8.6 A at 50 °C)
48 V 6 A (derate to 5 A at 50 °C)
5 V 35 A
5 V 12 A; +12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or –15 V 1.5 A or –5 V 0.7 A
5 V 12 A; +12 V 3.4 A or +15 V 3 A; -12 V 3.4 A or –15 V 3 A or –5 V 1.5 A
±12 V 5 A or ±15 V 5 A
12 V 10.2 A
15 V 9 A
2 V 18 A
24 V 7.2 A
28 V 6 A
48 V 4 A
5 V 18 A
Models may be followed by suffix G to indicate compliance to RoHS.
Derate output current ratings 10 % for operation at 50 Hz.
No derating required for operation at 50 °C ambient unless specified otherwise above.
For operation at >25 °C to 50 °C, derate output linearly to value shown in table.
Output capable of exceeding 240 VA when overloaded.
Output rating exceeds 240 VA.
Output exceeds 240 VA and may exceed 60 V dc as a result of a component failure.
Output may exceed 60 V dc under certain conditions.
Maximum Relative Humidity 96 %, no condensation.
Storage: -40 °C to +80 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
SAFETY DECLARATION: SL Power Electronics Corp. declares under our sole responsibility that all
models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions
of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable
requirements of UL 1950, CSA 22.2 No. 234 (see table for level), and EN 60950-1 for Pollution Degree 2
environment and Class I TN-S power systems. The output of some models poses an energy hazard or do not meet the
requirements for SELV. To identify these models, refer to the notes for the table above.
GROUNDING: Protection Class I requires that the chassis be bonded to Protective Earth in the end application.
SPACINGS: Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the
applicable safety standards, must be maintained after installation to preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the applicable safety
standards, must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature
and the availability, amount, direction and/or restriction of airflow influence the temperatures of these components.
WARNING! RISK OF FIRE! All models require
external fusing to maintain the intended safety. Refer to
marking on chassis for maximum fuse ratings.
1
2
100 VAC
AC INPUT HOOKUP
INSTRUCTIONS
1
3
5
4
1
2
120 VAC
3
5
4
2
215 VAC
3
5
4
1
230-240
VAC
2
3
5
4
41-33496-0001 Rev. G 09/12/06 SHT 1 OF 2
FUSING: Internal Secondary fuse(s) are provided on the models listed below A blown internal fuse is an indication of
catastrophic failure of circuit component(s). Repair must be performed by SL Power Electronics Corp. authorized personnel.
Fuse(s) must be replaced with the same type and ratings as listed below.
HB48-0.5-A+, HC48-1-A+: FN7 (T1) = F 1 A/125 V (Littlefuse P/N 251001 or Certified equiv.).
HD48-3-A+: FN7 (T1) = F 3 A/125 V (Littlefuse P/N 251003 or Certified equiv.).
HE48-4-A+: FN7 (T1) = F 5 A/125 V (Littlefuse P/N 251005 or Certified equiv.).
F15-15-A+, F24-12-A+, F48-6-A+: F1 (A1 PWB) = F 5 A/125 V (Littlefuse P/N 251005 or Certified equiv.).
CP197-A+, F5-25/OVP-A+, G5-35/OVP-A+: F1, F2 (A1 PWB) = F 5 A/125 V (Littlefuse P/N 251005 or Certified equiv.).
SL Power Electronics Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than
authorized agents of SL Power Electronics Corp., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, and EN
safety standards.
41-33496-0001 Rev. G 09/12/06
SHT 2 OF 2