omron.com

Digital Panel Meter
K3TE
CSM_K3TE_DS_E_3_1
Easy-to-use, Low-cost Digital Panel Meter
that Accepts DC Input
• Compact DIN-size (96 x 48 (W x H)) body.
• Mounting thickness of only 3.5 mm required.
• Highly visible display with 14.2-mm-high LEDs.
• Easy-to-mount snap-in construction.
• Conforms to EMC standards EN61010-1 (IEC61010-1).
For the most recent information on models that have been
certified for safety standards, refer to your OMRON website.
Note: This Panel Meter does not support scaling.
Model Number Structure
■ Model Number Legend
K3TE 1
2
1, 2. Input Code
V1:
V2:
V3:
V4:
A1:
A2:
A3:
A4:
A5:
±199.9 mV
±1.999 V
±19.99 V
±199.9 V
±199.9 µA
±1.999 mA
±19.99 mA
±199.9 mA
±1.999 A
3
4
3. Series No.
1: Current series
4. Supply Voltage
4: 100 to 120 VAC
5: 200 to 240 VAC
6: 24 VDC (internally insulated)
1
K3TE
Ordering Information
■ List of Models
Range
Measuring ranges
Supply voltage
100 to 120 VAC
DC voltage
DC current
200 to 240 VAC
24 VDC
(internally insulated)
±199.9 mV
K3TE-V114
K3TE-V115
K3TE-V116
±1.999 V
K3TE-V214
K3TE-V215
K3TE-V216
±19.99 V
K3TE-V314
K3TE-V315
K3TE-V316
±199.9 V
K3TE-V414
K3TE-V415
K3TE-V416
±199.9 µA
K3TE-A114
K3TE-A115
K3TE-A116
±1.999 mA
K3TE-A214
K3TE-A215
K3TE-A216
±19.99 mA
K3TE-A314
K3TE-A315
K3TE-A316
±199.9 mA
K3TE-A414
K3TE-A415
K3TE-A416
±1.999 mA
K3TE-A514
K3TE-A515
K3TE-A516
Note: The K3TE-V4@@ does not conform to CE marking standards.
■ Accessories (Order Separately)
Name
Appearance
Model
Water-resistive Soft Front Cover
K32-L49SC
Water-resistive Mounting Bracket
K32-L49MB
Watertight Cover
Y92A-49N
Note: Be sure to use the Soft Front Cover and Mounting Bracket as a set.
2
K3TE
Specifications
■ Ratings
Supply voltage
100 to 120 VAC; 200 to 240 VAC (50/60 Hz); 24 VDC (internally insulated)
Operating voltage range
−15% to +10% of supply voltage
Power consumption
3 VA (at max. AC load); 1.3 W (at max. DC load) (see note)
Insulation resistance
10 MΩ min. (at 500 VDC) between external terminal and case
Dielectric strength
AC model:
2,000 VAC min. for 1 min between input terminal and power supply
DC model:
500 VDC min. for 1 min between input terminal and power supply
AC/DC model: 2,000 VAC min. for 1 min between external terminal and case
Noise immunity
AC model:
DC model:
±1,500 V on power supply terminals in normal or common mode
±480 V on power supply terminals in normal mode
±1,500 V on power supply terminals in common mode
Vibration resistance
Malfunction:
Destruction:
10 to 55 Hz, 0.5-mm single amplitude for 10 min each in X, Y, and Z directions
10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions
Shock resistance
Malfunction:
Destruction:
98 m/s2 for 3 times each in 6 directions
294 m/s2 for 3 times each in 6 directions
Ambient temperature
Operating:
Storage:
−10° to 55°C (with no icing)
−20° to 65°C (with no icing)
Ambient humidity
Operating:
35% to 85% (with no condensation)
Ambient operating atmosphere
No corrosive gas
EMC
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Approved standards
Conforms to EN61326+A1, EN61010-1 (IEC61010-1)
Conforms to VDE0106/P100 (finger protection) when the terminal cover is mounted.
EN61326+A1
Industry
CISPR 11 Group 1 class A: CISRP16-1/-2
CISPR 11 Group 1 class A: CISRP16-1/-2
EN61326+A1
Industry
EN61000-4-2:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:
EN61000-4-3:
10 V/m (amplitude-modulated,
80 MHz to 1 GHz) (level 3)
Immunity Fast Transient Noise: EN61000-4-4:
2 kV (power line) (level 3)
Immunity Burst Noise:
1 kV line to line (I/O signal line)
Immunity Surge:
EN61000-4-5:
1 kV line to line
2 kV line to ground (power line)
Immunity Conducted Disturbance EN61000-4-6:
3 V (0.15 to 80 MHz) (level 2)
Immunity Voltage Dip/Interrupting EN61000-4-11:
0.5 cycles, 0, 180°, 100% (rated voltage)
Note: 1. An inrush current of approximately 0.5 A will flow at the moment the power is turned on and continued for approximately 2 ms.
2. The K3TE-V4@@ does not conform to CE marking standards.
■ Characteristics
Input signal
DC voltage/current
A/D conversion method
Double integral method
Sampling period
2.5 times/s
Display refresh period
2.5 times/s
Max. displayed digits
3 1/2 digits (±1999)
Display
7-segment red LED
Decimal point display position
By short-circuiting terminals
Sign display
“−” is displayed automatically with a negative input signal
Overflow/underflow display
Overflow: 1@@@
Underflow: −1@@@
Zero suppression
Not supported.
External control
Process value hold (terminals on rear panel short-circuited)
Degree of protection
Front panel: IEC IP51 (see note)
Case:
IEC IP20
Terminals: IEC IP00
Note: IP51 is maintained when the water-resistive soft cover and bracket are used. IP50 will be, however, maintained without these water-resistive
accessories.
3
K3TE
■ Measuring Ranges
Input range
Measuring range
DC voltage
DC current
Max. resolution
Input impedance
Accuracy
Max. permissible load
±199.9 mV
100 µV
100 MΩ
±0.1%rdg ±1 digit
±250 V
±1.999 V
1 mV
100 MΩ
±0.1%rdg ±1 digit
±250 V
±19.99 V
10 mV
10 MΩ
±0.1%rdg ±1 digit
±250 V
±199.9 V
100 mV
10 MΩ
±0.1%rdg ±1 digit
±350 V
±199.9 µA
100 nA
1 kΩ
±0.1%rdg ±1 digit
±10 mA
±1.999 mA
1 µA
100 Ω
±0.1%rdg ±1 digit
±50 mA
±19.99 mA
10 µA
10 Ω
±0.1%rdg ±1 digit
±150 mA
±199.9 mA
100 µA
1Ω
±0.1%rdg ±1 digit
±500 mA
±1.999 mA
1 mA
0.1 Ω
±0.3%rdg ±1 digit
±3 A
Note: The above accuracy is at an ambient temperature of 23±5°C.
Connections
■ External Connections
Connector and connector screws are provided with the model.
AC Power Supply
1
+
2
3
−
Signal input
4
5 6
DC Power Supply
7
8 9 10 11 12 13 14 15 16 17 18
COM HOLD
103 102 101
Decimal position
AC power supply
1 2
3
+
−
4
5 6
7
8 9 10 11 12 13 14 15 16 17 18
COM HOLD
Signal input
103 102 101
Decimal position
DC power supply
Note: 1. Terminals 3 and 7 of the AC and DC models are not internally insulated. Connect a relay with high contact reliability and insulation
(with a minimum load current of 0.3 mA) or a photocoupler with high insulation (with a residual voltage of 1 V max. and a current
leakage of 0.1 mA max.) to these terminals for external control.
2. The terminals marked with a white rectangular box are not used. Do not use these terminals for transmission of signals.
Nomenclature
Select the decimal position
with terminal 12, 13, or 14
on the rear panel.
PV display
103
102
101
Unit name
4
K3TE
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Panel Cutouts
92+0.8
−0
92
45+0.6
−0
75 min.
120 min.
48
43
Note: The values above are recommended
values. Do not group-mount the meters
at intervals less than the
recommended ones.
LED Indicator Size
96
70
3.5
14.2 mm
7.8 mm
Application Examples
High DC Voltage Measurement
Large DC Current Measurement
When voltage exceeding the maximum voltage in the
standard range is measured (for example: more than
200 V), a divider is connected externally.
When large DC current exceeding 2 A is measured, a
shunt is connected externally.
Divider
R1
Input
Lo
E1
R2
Hi
Hi
E2
Digital
panel
meter
Lo
Input
Hi
Voltage
(mV)
Current
Lo
Lo
Shunt
E2 = R2
E1 R1 + R2
Digital
panel
meter
When current range DPM is
used, disconnect the internal
shunt resistor.
5
K3TE
Safety Precautions
Mounting
Accessories (Order Separately)
Recommended panel thickness is 1 to 3.2 mm.
When mounting, insert the Digital Panel Meter in the mounting hole
and make sure that the Digital Panel Meter is secured with mounting
hooks.
Always attach the Mounting Bracket before wiring the terminals. Also,
always remove the wiring before removing the Mounting Bracket.
Mount the Digital Panel Meter as horizontally as possible.
Never use the Digital Panel Meter in locations where corrosive gas
(particularly sulfide or ammonia gas) is generated.
Water-resistive Soft Front Cover
Before mounting the Digital Panel Meter to a panel, attach the waterresistive soft front cover and mounting bracket to the Digital Panel
Meter properly so that the Digital Panel Meter will maintain IP51
water-resistive standards. Before you calibrate Digital Panel Meters,
remove the water-resistive soft front cover. Refer to the operation
manual included with the Digital Panel Meter for the calibration procedure.
As much as possible avoid use of the Digital Panel Meter in a location subject to severe shock or vibration, excessive dust, or excessive moisture.
Mounting
Bracket
Select a mounting location where the Digital Panel Meter can be
used at an ambient operating temperature −10° to 55°C.
No product is shipped with the unit label attached. Select a unit label
from the sheet provided, and attach it to the Digital Panel Meter.
Soft Cover
Note: Be sure to use the Water-resistive Soft Front Cover and
mounting bracket together.
Calibration
Calibrate the Digital Panel Meter regularly so that the Digital Panel
Meter can maintain processing accuracy.
Use a standard signal generator with an accuracy of 99.99% min. for
calibration.
For the precise calibration methods, refer to the Instruction Sheet for
the Digital Panel Meter.
After the front panel cover is removed to calibrate the K3TE, be sure
not to touch components other than the calibration adjustor. Keep
metal objects off the K3TE while calibrating, especially when power
is turned on.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
6
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.2
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/