G2R-@-S - OMRON Industrial Automation

General-purpose Relay
G2R-@-S
CSM_G2R-_-S_DS_E_3_2
Slim and Space-saving Power Plug-in Relay
■ Lockable test button models now available.
■ Built-in mechanical operation indicator.
■ Provided with nameplate.
■ AC type is equipped with a coil-disconnection self-diagnostic
function (LED type).
■ High switching power (1-pole: 10 A).
■ Environment-friendly (Cd, Pb free).
■ Wide range of Sockets also available.
LR
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
G2R
-
-
1
2
3 4
5
1. Relay Function
Blank: General-purpose
6
7
5. Terminals
S:
Plug-in
2. Number of Poles
1:
1 pole
2:
2 poles
6. Classification
Blank: General-purpose
N:
LED indicator
D:
Diode
ND:
LED indicator and diode
NI:
LED indicator with test button
NDI:
LED indicator and diode with test button
3. Contact Form
Blank: SPDT
4. Contact Type
Blank: Single
7. Rated Coil Voltage
Ordering Information
List of Models
Classification
Enclosure
rating
Coil ratings
General-purpose
LED indicator
Plug-in terminal
LED indicator with test button
Diode
LED indicator and diode
LED indicator and diode with test button
AC/DC
Unsealed
DC
Contact form
SPDT
DPDT
G2R-1-S
G2R-2-S
G2R-1-SN
G2R-2-SN
G2R-1-SNI (S)
G2R-2-SNI (S)
G2R-1-SD
G2R-2-SD
G2R-1-SND
G2R-2-SND
G2R-1-SNDI (S)
G2R-2-SNDI (S)
Note: 1. The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combinations with the P2RF-E and P2RF-S. The Relays bear the CE Marking.
2. Refer to Connecting Sockets, below, for applicable Socket models.
3. When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.
New model
Example: G2R-1-S 12 VDC (S)
Rated coil voltage
1
G2R-@-S
Accessories (Order Separately)
Connecting Sockets
Track/surface-mounting Socket
Applicable Relay model
Screwless clamp terminal
1 pole
G2R-1-S(N)(D)(ND)(NI)(NDI)
• P2RF-05S (See note.)
+
(P2CM-S (option))
2 poles
G2R-2-S(N)(D)(ND)(NI)(NDI)
• P2RF-08S (See note.)
+
(P2CM-S (option))
Back-mounting Socket
Screw terminal
Terminals
Model
• P2RF-05-E
• P2RF-05
PCB terminals
P2R-05P, P2R-057P
Solder terminals
P2R-05A
• P2RF-08-E
• P2RF-08
PCB terminals
P2R-08P, P2R-087P
Solder terminals
P2R-08A
Note: Use of the P2CM Clip & Release Lever is recommended to ensure stable mounting.
Accessories for Screwless Clamp Terminal Socket (Option)
Name
Model
Clip & Release Lever
P2CM-S
Nameplate
R99-11 Nameplate for MY
Socket Bridge
P2RM-SR (for AC), P2RM-SB (for DC)
Mounting Tracks
Applicable Socket
Description
Model
Mounting track
50 cm (l) x 7.3 mm (t): PFP-50N
1 m (l) x 7.3 mm (t): PFP-100N
1 m (l) x 16 mm (t): PFP-100N2
End plate
PFP-M
Track-connecting Socket
Back-connecting Socket
Spacer
PFP-S
Mounting plate
P2R-P*
* Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
Specifications
Coil Ratings
Rated current*
Rated voltage
50 Hz
AC
60 Hz
Coil inductance (H)
(ref. value)
Armature
OFF
Armature
ON
24 V
43.5 mA
37.4 mA
253 Ω
0.81
1.55
110 V
9.5 mA
8.2 mA
5,566 Ω
13.33
26.83
120 V
8.6 mA
7.5 mA
7,286 Ω
16.13
32.46
230 V
4.4 mA
3.8 mA
27,172 Ω
72.68
143.90
240 V
3.7 mA
3.2 mA
30,360 Ω
90.58
182.34
Rated voltage
DC
Coil
resistance*
Rated current*
Coil
resistance*
Coil inductance (H)
(ref. value)
Armature
OFF
Armature
ON
6V
87.0 mA
69 Ω
0.25
0.48
12 V
43.2 mA
278 Ω
0.98
2.35
24 V
21.6 mA
1,113 Ω
3.60
8.25
48 V
11.4 mA
4,220 Ω
15.2
29.82
Must
operate
voltage
Must
release
voltage
Max.
voltage
% of rated voltage
80% max.
30% max.
Must
operate
voltage
Must
release
voltage
110%
Max.
voltage
% of rated voltage
70% max.
15% min.
110%
Power
consumption
(approx.)
0.9 VA at 60 Hz
Power
consumption
(approx.)
0.53 W
* The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±10%.
2
G2R-@-S
Contact Ratings
Number of poles
1 pole
Load
Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
(cosφ = 1)
2 poles
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Rated load
10 A at 250 VAC;
10 A at 30 VDC
7.5 A at 250 VAC;
5 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 3 A at
30 VDC
Rated carry current
10 A
5A
Max. switching voltage
440 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current
10 A
Max. switching power
2,500 VA,
300 W
Failure rate (reference value)
100 mA at 5 VDC
5A
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
10 mA at 5 VDC
Note: P level: λ60 = 0.1 x 10-6/operation
Characteristics
Item
1 pole
2 poles
Contact resistance
100 mΩ max.
Operate (set) time
15 ms max.
Release (reset) time
AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
Max. operating
frequency
Mechanical:
Electrical:
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
5,000 VAC, 50/60 Hz for 1 min between coil and
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
same polarity
Vibration resistance
Destruction:
Malfunction:
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance
Destruction:
Malfunction:
1,000 m/s2
200 m/s2 when energized; 100 m/s2 when not energized
Mechanical:
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)
Endurance
Electrical:
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
18,000 operations/hr
1,800 operations/hr (under rated load)
Ambient temperature
Operating:
–40°C to 70°C (with no icing or condensation)
Ambient humidity
Operating:
5% to 85%
Weight
Approx. 21 g
Note: Values in the above table are the initial values.
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is mounted.
Approved Standards
UL 508 (File No. E41643)
Model
Contact
form
Coil ratings
G2R-1-S SPDT
5 to 110 VDC
6 to 240 VAC
G2R-2-S DPDT
IEC/VDE (EN61810)
Contact ratings
Operations
Contact
form
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
1 pole
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
100 x 103
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
2 poles
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms)
100 x 103
CSA 22.2 No.0, No.14
(File No. LR31928)
Model
Contact
form
Coil ratings
G2R-1-S SPDT
5 to 110 VDC
6 to 240 VAC
G2R-2-S DPDT
Coil ratings
Contact ratings
Operations
LR
Contact ratings
Operations
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
Number
of poles
Coil ratings
Contact ratings
Operations
1 pole
5 to 110 VDC
6 to 240 VDC
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
100 x 103
2 poles
5 to 110 VDC
6 to 240 VDC
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
100 x 103
3
G2R-@-S
Engineering Data
Maximum Switching Power
Plug-in Relays
G2R-2-S
G2R-1-S
100
Switching current (A)
AC inductive load
(cosφ = 0.4)
AC resistive
load
10
DC resistive
load
DC inductive load
(L/R = 7 ms)
1
0.1
1
10
100
Switching current (A)
100
AC resistive
load
DC resistive
load
1
0.1
1000
AC inductive load
(cosφ = 0.4)
10
DC inductive load
(L/R = 7 ms)
1
10
Switching voltage (V)
100
1000
Switching voltage (V)
Endurance
Plug-in Relays
G2R-2-S
10,000
5,000
1,000
250-VAC/30-VDC
resistive load
500
100
250-VAC inductive load
(cosφ = 0.4)
30-VDC inductive load (L/R = 7ms)
50
Switching current (A)
Endurance (x103 operations)
Endurance (x103 operations)
G2R-1-S
5,000
1,000
500
30-VDC inductive load (L/R = 7ms)
250-VAC/30-VDC
resistive load
100
250-VAC
50 inductive load
(cosφ = 0.4)
Switching current (A)
Maximum voltage (%)
Ambient Temperature vs Maximum Coil Voltage
DC coil
AC coil
Note: The maximum voltage refers to the maximum
value in a varying range of operating power
voltage, not a continuous voltage.
Ambient temperature (°C)
4
G2R-@-S
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Relays with Plug-in Terminals
SPDT Relays
G2R-1-S, G2R-1-SN, G2R-1-SNI (S)
G2R-1-SD, G2R-1-SND, G2R-1-SNDI (S)
Terminal Arrangement/Internal Connections
(Bottom View)
G2R-1-SD (DC)
G2R-1-S
29 max.
1
13 max.
1
2
20
35.5 max.
5
4
3
G2R-1-SN, G2R-1-SNI (AC)
4.75
2
5
3
4
5
2
4
3
7.5
0.5
1
5
1
24V
3
4
G2R-1-SN, G2R-1-SNI (DC)
1
DC
2
5
G2R-1-SND, G2R-1-SNDI (DC)
5.2
5.2
17.5
1
2
5
4
3
DPDT Relays
G2R-2-S, G2R-2-SN, G2R-2-SNI (S)
G2R-2-SD, G2R-2-SND, G2R-2-SNDI (S)
Terminal Arrangement/Internal Connections
(Bottom View)
G2R-2-S
1
2
3
4
8
7
6
5
13 max.
2.5
35.5 max.
1
2
3
4
8
7
6
5
G2R-2-SN, G2R-2-SNI (DC)
1
2
3
4
1
2
3
4
8
7
6
5
8
7
6
5
7.4
8.9
2.4
G2R-2-SN, G2R-2-SNI (AC)
6.2
20
29 max.
0.5
G2R-2-SD (DC)
G2R-2-SND, G2R-2-SNDI (DC)
5
5
19.4
1
2
3
4
8
7
6
5
5
G2R-@-S
Track/Surface Mounting Sockets
38.2 max.
P2RF-05-S
Terminal Arrangement
(Top View)
36.5 max.
11
32.6
14
27.6
12
Option (with ejector and
label attached)
92.0 max.
Standard model
35.4
24.5
22.6
(5.3)
28.5
18.0 max.
A1 A2
32.6
Terminal Arrangement
(Top View)
38.2 max.
P2RF-08-S
36.5 max.
21 11
24 14
32.6
27.6
22 12
(3.4)
Standard model
35.4
92.0 max.
24.5
22.6
A1 A2
Option (with ejector
and label attached)
(5.3)
28.6
18.0 max.
32.6
Accessories for P2RF-@-S
Socket Bridge
Clip and Release Lever
Insulating coating
L
1.2 dia. conductor (See note 1.)
14
16.8
40.35
36
9
6
G2R-@-S
Terminal Arrangement
(Top View)
P2RF-05-E
Five, M3.5×7
2
48 max.
4
(14)
39.5
3
35.5
85.5 max.
Mounting Holes
(for Surface Mounting)
3.2-dia.
hole
(11)
2
(12)
39.5±0.1
3.5-dia.
hole
M3 or
3.5-dia.
hole
5
(A1)
(A2)
1
11.5
61 max.
16.0 max.
Note: Pin numbers in parentheses apply to DIN standard.
P2RF-08-E
2
Terminal Arrangement
(Top View)
2
1.5
Eight, M3×8
48.0 max.
Mounting Holes
(for Surface Mounting)
3
39.5
(21)
(22)
(24)
6
3
7
5
2
4
(11)
(12)
(14)
3.2-dia.
hole
35.5
85.5
max.
39.5±0.1
3.5-dia. hole
8
(A1)
(A2)
5
61.0
max.
1
M3 or
3.5-dia.
hole
11.5
16.0 max.
P2RF-05
2
7
Terminal Arrangement
(Top View)
Five, M3.5 x 8
4-dia. holes
Mounting Holes
(for Surface Mounting)
4.2-dia. hole
35.5
71.5 max.
30±0.05
4
19.5
30 max.
19.5 max.
M3 or 3.2-dia.
hole
54 max.
P2RF-08
2
7
Eight, M3.5 x 8
4-dia. holes
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
4.2-dia. hole
35.5
71.5 max.
30±0.05
4
19.5 max.
19.5
30 max.
54 max.
M3 or 3.2-dia.
hole
7
G2R-@-S
Mounting Height of Relay with Track/Surface Mounting Sockets
P2RF-@-E
P2RF-@
62.0
66.5
70.5
67.0
P2RF-@-S
72.0
65.0
28.6
(5.30)
Back-connecting Sockets
P2R-05P (1-pole)
4
1
Terminal Arrangement
(Bottom View)
14.5 max.
7
Mounting Holes
Tolerance: ±0.1
4
6
4.5
6
35.5 max.
15
Five,
1.6-dia.
holes
4.5
1.2
4
15
3.5
4
1.5
(5)
4
7
7
36.5 max.
P2R-08P (2-pole)
4
0.3
14.5 max.
7
Terminal Arrangement
(Bottom View)
Mounting Holes
7.5
Eight, 1.3-dia. holes
5
5
35.5 max.
20
1
5
5
20
2.8
1.5
(4.3)
7.5
Terminal plate thickness: 0.3
36.5 max.
8
G2R-@-S
5
P2R-05A (1-pole)
7
14.5 max.
1.2
0.3
Terminal Arrangement
(Bottom View)
6.7
3.8
35.5 max.
5
16.7
Panel Cutout
Five, 3 x 1.8-dia. holes
13.6±0.1
6
36.5 max.
Terminal plate thickness: 0.3
P2R-08A (2-pole)
7
30.5±0.2
7
14.5 max.
1.2
0.3
5
5
35.5 max.
Recommended thickness of
the panel is 1.6 to 2.0 mm
20
2.6
2.8
1.5
Eight, 3 x 1.2-dia. holes
7.5
Terminal plate thickness: 0.3
P2R-057P
0.7
14 max.
8.7
16.4
10.4
1
36.5 max.
Terminal Arrangement
(Bottom View)
Mounting Holes
4±0.1
Five,
1.6-dia.
holes
6±0.1
37 max.29.6
4.5±0.1 15±0.1
8.7
4±0.1
5
7.4
7±0.1
41 max.
P2R-087P
14 max.
7.5
Terminal Arrangement
(Bottom View)
16.4
1
10.4
Mounting Holes
7.5
37 max. 29.1
Eight,
1.3-dia.
holes
5
5
20
7.4
8.9
(8.1)
41 max.
Mounting Height of Relay with Back-connecting Sockets
G2R-@P
G2R-@A
G2R-@7P
G2R Relay
G2R Relay
44.5
P2R-_P
Socket
47.5
38.0
P2R-_A
Socket
9
G2R-@-S
Mounting Tracks
PFP-100N, PFP-50N
PFP-100N2
16
7.3±0.15
4.5
4.5
15
25
25
25
25
10
10
1,000 (500)
35±0.3 27
27±0.15
35±0.3
15 (5)
15
1
25
25 15
25
25
10
10
24
29.2
1
1.5
1,000
It is recommended to use a panel 1.6 to 2.0 mm thick.
End Plate
Spacer
10
6.2
PFP-M
PFP-S
16
12
5
1.8
1
50
1.8
11.5
10
M4 x 8 pan
head screw
35.5 35.3
34.8
44.3
1.3
4.8
16.5
Precautions
Cation
• Do not use the test button for any purpose other than testing. Be
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
• Check that the test button is released before turning ON relay circuits.
• If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position.
• Use an insulated tool when you operate the test button.
Precautions for P2RF-@-S Connection
• Do not move the screwdriver up, down, or from side to side while it
is inserted in the hole. Doing so may cause damage to internal
components (e.g., deformation of the clamp spring or cracks in the
housing) or cause deterioration of insulation.
• Do not insert the screwdriver at an angle. Doing so may break the
side of the socket and result in a short-circuit.
10
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
 Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
 Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
 Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.