Datasheet

D3V
Miniature Basic Switch
Reliable Basic Switch with
External Lever
● Available by 21 A, 16 A, 11 A, 6 A and 0.1 A
models, all with self-cleaning contacts.
● Available with internally or externally fitted
D
3
V
levers.
RoHS Compliant
Model Number Legend
1
D 3 V- @
1. Ratings
21 : 20 (4) A at 250 VAC
16 : 16 (3) A at 250 VAC
11 : 11 (3) A at 250 VAC
6 : 16 (2) A at 250 VAC
01 : 0.1 A at 125 VAC
2. Contact Gap
None : 1 mm (F gap)
G : 0.5 mm (G gap)
3. Actuator
None : Pin plunger
1 : Short hinge lever
2 : Hinge lever
3 : Long hinge lever
4 : Simulated roller lever
5 : Short hinge roller lever
6 : Hinge roller lever
4. Hinge Position
None : Internal/Far from plunger
8.1
2 @
3 @
4 -@
5 @
6 @
7 -@
8 -@
9
@
5. Contact Form
1 : SPDT
2 : SPST-NC
3 : SPST-NO
6. Terminals
A : Solder terminals
C2 : Quick-connect terminals (#187)
C : Quick-connect terminals (#250)
7. Maximum Operating Force
5 : 1.96 N {200 gf}
4A : 1.23 N {125 gf}
4 : 0.98 N {100 gf}
3 : 0.49 N {50 gf}
2 : 0.25 N {25 gf}
Note. These values are for the pin plunger models.
8. Mounting Hole Size
None : 3.1 mm
K : 2.9 mm
9. Special Code
None : Standard
H : High temperature (125°C) (See note)
E : Special rating: 21 (8) A
Note. Consult your OMRON sales representative for high
temperature models.
K
: External/Near plunger
14.3
1
D3V
Miniature Basic Switch
List of Models
●21 A (OF: 1.23 N {125 gf})
Ratings
Contact gap
Actuators
Pin plunger
Contact form
Terminals
Maximum operating
force (OF)
D3V-21G-1C4A
SPDT
SPDT-NC
Quick-connect
terminals (#250)
(C)
-
1.23 N {125 gf}
-
SPDT-NO
Short hinge lever
SPDT-NC
D
3
V
D3V-21G1-1C4A
SPDT
-
1.23 N {125 gf}
-
SPDT-NO
Hinge lever
SPDT
SPDT-NC
D3V-21G2-1C4A
-
0.78 N {80 gf}
-
SPDT-NO
Long hinge lever
21 A
0.5 mm
(G gap)
SPDT
SPDT-NC
D3V-21G3-1C4A
-
0.44 N {45 gf}
-
SPDT-NO
Simulated roller lever
SPDT
SPDT-NC
D3V-21G4-1C4A
-
0.83 N {85 gf}
-
SPDT-NO
Short hinge roller lever
SPDT
SPDT-NC
D3V-21G5-1C4A
-
1.42 N {145 gf}
-
SPDT-NO
Hinge roller lever
D3V-21G6-1C4A
SPDT
SPDT-NC
-
0.79 N {80 gf}
-
SPDT-NO
Note. If you need mounting hole 2.9 mm, add "-K" at last of model.
Consult your OMRON sales representative when you can't find a model on this List of Models.
●16 A (OF: 1.96 N {200 gf})
Ratings
Contact gap
Actuators
Pin plunger
Contact form
SPDT
D3V-16-1C5
D3V-16-2C25
D3V-16-2C5
SPDT-NO
D3V-16-3A5
D3V-16-3C25
D3V-16-3C5
SPDT
D3V-161-1A5
D3V-161-1C25
D3V-161-1C5
D3V-161-2A5
D3V-161-2C25
D3V-161-2C5
D3V-161-3A5
D3V-161-3C25
D3V-161-3C5
D3V-162-1A5
D3V-162-1C25
D3V-162-1C5
D3V-162-2A5
D3V-162-2C25
D3V-162-2C5
1.96 N {200 gf}
SPDT
SPDT-NC
16 A
1 mm
(F gap)
1.23 N {125 gf}
SPDT-NO
D3V-162-3A5
D3V-162-3C25
D3V-162-3C5
SPDT
D3V-163-1A5
D3V-163-1C25
D3V-163-1C5
SPDT-NC
Simulated roller lever
D3V-163-2A5
D3V-163-2C25
D3V-163-2C5
SPDT-NO
D3V-163-3A5
D3V-163-3C25
D3V-163-3C5
SPDT
D3V-164-1A5
D3V-164-1C25
D3V-164-1C5
SPDT-NC
0.69 N {70 gf}
1.23 N {125 gf}
SPDT-NO
Short hinge roller lever
SPDT
SPDT-NC
2.35 N {240 gf}
SPDT-NO
Hinge roller lever
SPDT
SPDT-NC
SPDT-NO
1.23 N {125 gf}
D3V-164-2A5
D3V-164-2C25
D3V-164-2C5
D3V-164-3A5
D3V-164-3C25
D3V-164-3C5
D3V-165-1A5
D3V-165-1C25
D3V-165-1C5
D3V-165-2A5
D3V-165-2C25
D3V-165-2C5
D3V-165-3A5
D3V-165-3C25
D3V-165-3C5
D3V-166-1A5
D3V-166-1C25
D3V-166-1C5
D3V-166-2A5
D3V-166-2C25
D3V-166-2C5
D3V-166-3A5
D3V-166-3C25
D3V-166-3C5
Note. If you need mounting hole 2.9 mm, add "-K" at last of model.
Consult your OMRON sales representative when you can't find a model on this List of Models.
2
Quick-connect
terminals (#250)
(C)
D3V-16-1C25
1.96 N {200 gf}
SPDT-NO
Long hinge lever
Quick-connect
terminals (#187)
(C2)
D3V-16-2A5
SPDT-NC
Hinge lever
Solder terminals
(A)
D3V-16-1A5
SPDT-NC
Short hinge lever
Terminals
Maximum operating
force (OF)
D3V
Miniature Basic Switch
●11 A (OF: 1.96 N {200 gf})
Ratings
Contact gap
Actuators
Pin plunger
Contact form
Terminals
Maximum operating
force (OF)
D3V-11-1A5
SPDT
SPDT-NC
Solder terminals
(A)
-
1.96N {200 gf}
-
SPDT-NO
Short hinge lever
D3V-111-1A5
SPDT
SPDT-NC
1.96N {200 gf}
SPDT-NO
Hinge lever
SPDT
SPDT-NC
Long hinge lever
11 A
1 mm
(F gap)
SPDT-NC
0.69N {70 gf}
Simulated roller lever
SPDT
SPDT-NC
SPDT-NO
Short hinge roller lever
SPDT
SPDT-NC
SPDT-NO
Hinge roller lever
D3V-112-1C25
D3V-113-1C25
D3V-113-1C5
-
-
-
-
-
D3V-114-1C25
D3V-114-1C5
-
-
-
-
-
-
D3V-115-1C25
D3V-115-1C5
-
-
-
-
-
-
D3V-116-1C25
D3V-116-1C5
-
-
-
-
-
-
Solder terminals
(A)
Quick-connect
terminals (#187)
(C2)
Quick-connect
terminals (#250)
(C)
1.23N {125 gf}
SPDT-NO
D
3
V
D3V-112-1C5
-
D3V-116-1A5
SPDT
SPDT-NC
-
D3V-115-1A5
2.35N {240 gf}
D3V-111-1C5
-
D3V-114-1A5
1.23N {125 gf}
-
-
D3V-113-1A5
SPDT-NO
D3V-111-1C25
D3V-11-1C5
-
-
SPDT
-
-
-
SPDT-NO
D3V-11-1C25
Quick-connect
terminals (#250)
(C)
D3V-112-1A5
1.23N {125 gf}
Quick-connect
terminals (#187)
(C2)
Note. If you need mounting hole 2.9 mm, add "-K" at last of model.
Consult your OMRON sales representative when you can't find a model on this List of Models.
●11 A (OF: 0.98 N {100 gf})
Ratings
Contact gap
Actuators
Pin plunger
Contact form
Terminals
Maximum operating
force (OF)
SPDT
SPDT-NC
D3V-11-1A4
0.98N {100 gf}
SPDT-NO
Short hinge lever
SPDT
SPDT-NC
SPDT-NO
Hinge lever
SPDT
SPDT-NC
SPDT-NO
Long hinge lever
11 A
1 mm
(F gap)
0.34N {35 gf}
SPDT-NO
Simulated roller lever
0.59N {60 gf}
SPDT-NO
Short hinge roller lever
SPDT
SPDT-NC
SPDT-NC
-
-
-
D3V-112-1C4
-
-
-
-
-
D3V-113-1C24
D3V-113-1C4
-
-
-
-
-
-
D3V-114-1C24
D3V-114-1C4
-
-
-
-
-
-
D3V-116-1A4
0.59N {60 gf}
D3V-112-1C24
-
-
SPDT-NO
D3V-111-1C4
-
-
SPDT
D3V-111-1C24
-
D3V-115-1A4
1.18N {120 gf}
SPDT-NO
Hinge roller lever
-
D3V-114-1A4
SPDT
SPDT-NC
-
D3V-113-1A4
SPDT
SPDT-NC
-
D3V-112-1A4
0.59N {60 gf}
D3V-11-1C4
D3V-111-1A4
0.98N {100 gf}
D3V-11-1C24
D3V-115-1C24
D3V-116-1C24
D3V-115-1C4
D3V-116-1C4
-
-
-
-
-
-
Note. If you need mounting hole 2.9 mm, add "-K" at last of model.
Consult your OMRON sales representative when you can't find a model on this List of Models.
3
D3V
Miniature Basic Switch
●6 A (OF: 0.98 N {100 gf})
Ratings
Contact gap
Actuators
Pin plunger
Contact form
Terminals
Maximum operating
force (OF)
D3V-6-1A4
SPDT
SPDT-NC
Solder terminals
(A)
-
0.98 N {100 gf}
-
SPDT-NO
Short hinge lever
SPDT-NC
D
3
V
D3V-61-1A4
SPDT
0.98 N {100 gf}
SPDT-NO
Hinge lever
SPDT
SPDT-NC
Long hinge lever
6A
1 mm
(F gap)
SPDT-NC
0.34 N {35 gf}
Simulated roller lever
SPDT
SPDT-NC
SPDT-NO
Short hinge roller lever
SPDT
SPDT-NC
SPDT-NO
Hinge roller lever
D3V-62-1C24
D3V-63-1C24
D3V-62-1C4
D3V-63-1C4
-
-
-
-
-
-
D3V-64-1C24
D3V-64-1C4
-
-
-
-
-
-
D3V-65-1C24
D3V-65-1C4
-
-
-
-
-
-
D3V-66-1A4
SPDT
SPDT-NC
-
D3V-65-1A4
1.18 N {120 gf}
D3V-61-1C4
-
D3V-64-1A4
0.59 N {60 gf}
-
-
D3V-63-1A4
SPDT-NO
D3V-61-1C24
D3V-6-1C4
-
-
SPDT
-
-
-
SPDT-NO
D3V-6-1C24
Quick-connect
terminals (#250)
(C)
D3V-62-1A4
0.59 N {60 gf}
Quick-connect
terminals (#187)
(C2)
D3V-66-1C24
D3V-66-1C4
-
-
-
-
-
-
Solder terminals
(A)
Quick-connect
terminals (#187)
(C2)
Quick-connect
terminals (#250)
(C)
0.59 N {60 gf}
SPDT-NO
●6 A (OF: 0.49 N {50 gf})
Ratings
Contact gap
Actuators
Pin plunger
Contact form
Terminals
Maximum operating
force (OF)
SPDT
SPDT-NC
D3V-6G-1A3
-
0.49 N {50 gf}
-
SPDT-NO
Short hinge lever
D3V-6G1-1A3
SPDT
SPDT-NC
0.49 N {50 gf}
SPDT-NO
Hinge lever
Long hinge lever
6A
0.5 mm
Ggap)
SPDT
SPDT-NC
0.20 N {20 gf}
Simulated roller lever
SPDT
SPDT-NC
SPDT-NO
Short hinge roller lever
SPDT
SPDT-NC
0.29 N {30 gf}
SPDT-NO
Note. If you need mounting hole 2.9 mm, add "-K" at last of model.
Consult your OMRON sales representative when you can't find a model on this List of Models.
4
D3V-6G3-1C23
D3V-6G2-1C3
D3V-6G3-1C3
-
-
-
-
-
D3V-6G4-1C23
D3V-6G4-1C3
-
-
-
-
-
-
D3V-6G5-1C23
D3V-6G5-1C3
-
-
-
-
-
-
D3V-6G6-1A3
SPDT
SPDT-NC
D3V-6G2-1C23
-
D3V-6G5-1A3
0.59 N {60 gf}
SPDT-NO
Hinge roller lever
-
D3V-6G4-1A3
0.29 N {30 gf}
D3V-6G1-1C3
-
D3V-6G3-1A3
SPDT-NO
-
-
-
SPDT-NO
D3V-6G1-1C23
D3V-6G-1C3
-
-
0.59 N {60 gf}
-
D3V-6G2-1A3
SPDT
SPDT-NC
D3V-6G-1C23
D3V-6G6-1C23
D3V-6G6-1C3
-
-
-
-
-
-
D3V
Miniature Basic Switch
●0.1 A (OF: 0.49 N {50 gf})
Ratings
Contact gap
Actuators
Pin plunger
Contact form
Terminals
Maximum operating
force (OF)
SPDT
SPDT-NC
0.49 N {50 gf}
D3V-01-1A3
D3V-01-1C23
D3V-01-1C3
D3V-01-2A3
D3V-01-2C23
D3V-01-2C3
D3V-01-3A3
D3V-01-3C23
D3V-01-3C3
SPDT
D3V-011-1A3
D3V-011-1C23
D3V-011-1C3
D3V-011-2A3
D3V-011-2C23
D3V-011-2C3
D3V-011-3A3
D3V-011-3C23
D3V-011-3C3
SPDT-NC
0.49 N {50 gf}
SPDT-NO
Hinge lever
SPDT
SPDT-NC
0.59 N {60 gf}
SPDT-NO
Long hinge lever
1 mm
(F gap)
Quick-connect
terminals (#250)
(C)
SPDT-NO
Short hinge lever
0.1 A
Quick-connect
terminals (#187)
(C2)
Solder terminals
(A)
SPDT
SPDT-NC
0.20 N {20 gf}
D3V-012-1A3
D3V-012-1C23
D3V-012-1C3
D3V-012-2A3
D3V-012-2C23
D3V-012-2C3
D3V-012-3A3
D3V-012-3C23
D3V-012-3C3
D3V-013-1A3
D3V-013-1C23
D3V-013-1C3
D3V-013-2A3
D3V-013-2C23
D3V-013-2C3
SPDT-NO
D3V-013-3A3
D3V-013-3C23
D3V-013-3C3
SPDT
D3V-014-1A3
D3V-014-1C23
D3V-014-1C3
D3V-014-2A3
D3V-014-2C23
D3V-014-2C3
Simulated roller lever
SPDT-NC
0.29 N {30 gf}
SPDT-NO
D3V-014-3A3
D3V-014-3C23
D3V-014-3C3
SPDT
D3V-015-1A3
D3V-015-1C23
D3V-015-1C3
D3V-015-2C3
Short hinge roller lever
D3V-015-2A3
D3V-015-2C23
SPDT-NO
SPDT-NC
D3V-015-3A3
D3V-015-3C23
D3V-015-3C3
SPDT
D3V-016-1A3
D3V-016-1C23
D3V-016-1C3
D3V-016-2A3
D3V-016-2C23
D3V-016-2C3
D3V-016-3A3
D3V-016-3C23
D3V-016-3C3
Hinge roller lever
0.59 N {60 gf}
SPDT-NC
0.29 N {30 gf}
SPDT-NO
D
3
V
Note. If you need mounting hole 2.9 mm, add "-K" at last of model.
Consult your OMRON sales representative when you can't find a model on this List of Models.
Contact Form
●SPDT
●SPST-NC
●SPST-NO
NC
NO
NC
NO
COM
COM
COM
Contact Specifications
Item
Model
D3V-21
D3V-16
D3V-11
Specification
Contact
Material
Gap (standard value)
Inrush current
NC
NO
Minimum applicable load (see note)
0.5 mm
50 A max.
D3V-6
Crossbar
Silver alloy
Gold alloy
1.0 mm (F gap) or 0.5 mm (G gap)
40 A max.
D3V-01
Rivet
24 A max.
160 mA at 5 VDC
1.0 mm
15 A max.
--1 mA at 5 VDC
Note. For more information on the minimum applicable load, refer to Using Micro Loads on page 11.
5
D3V
Miniature Basic Switch
Ratings
Item
Model
D3V-21
D3V-16
D
3
V
Resistive load
Rated voltage
D3V-11
D3V-6
D3V-01
250 VAC
21 A
125 VDC
0.6 A
250 VDC
0.3 A
250 VAC
16 A
125 VDC
0.6 A
250 VDC
0.3 A
250 VAC
11 A
125 VDC
0.6 A
250 VDC
0.3 A
250 VAC
6A
125 VDC
0.4 A
250 VDC
0.3 A
125 VAC
0.1 A
30 VDC
0.1 A
Note 1. The above current values are the normal current values of models with a contact gap of 1 mm (gap F), which vary with the normal current values of models with
a contact gap of 0.5 mm (gap G).
Note 2. The ratings values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min
Approved Safety Standards
Consult your OMRON sales representative for specific models with standard approvals.
UL1054 (File No. E41515)/CSA C22.2 No.55 (File No. LR21642)
Rated voltage
D3V-21G
D3V-16
D3V-16G
D3V-11
D3V-11G
D3V-6
D3V-6G
D3V-01
125 VAC
Model
---
16 A, 1/2 HP
16 A, 1/2 HP
11 A, 1/2 HP
11 A, 1/2 HP
6 A, 1/4 HP
6 A, 1/4 HP
0.1 A
250 VAC
20.1 A
16 A, 1/2 HP
16 A, 1/2 HP
11 A, 1/2 HP
11 A, 1/2 HP
6 A, 1/4 HP
6 A, 1/4 HP
---
125 VDC
---
0.6 A
0.1 A
0.6 A
0.1 A
---
---
---
250 VDC
---
0.3 A
---
0.3 A
---
---
---
---
EN 61058-1: 1992+A1: 1993 (License No. 40024894)
Rated voltage
Model
D3V-21G
D3V-16
D3V-11
D3V-6
D3V-01
125 VAC
---
---
---
---
0.1 A
250 VAC
20 (4) A
16 (3) A
11 (3) A
6 (2) A
---
Testing conditions: 5E4 (50,000 operations), T85 (0 to 85°C) for D3V-21/D3V-01, T105 (0 to 105°C) for D3V-16/D3V-11/D3V-6
Rated voltage
250 VAC
Model
D3V-21G
21 (8) A
Testing conditions: 10,000 operations, T85 (0 to 85°C)
6
D3V
Miniature Basic Switch
Characteristics
Item
Model
D3V-21
D3V-16
Permissible operating speed
D3V-11
D3V-6
D3V-01
0.1 mm to 1 m/s (pin plunger models)
Mechanical: 600 operations/min max.
Electrical:
30 operations/min max.
Permissible operating frequency
Insulation resistance
100 MΩ min. (at 500 VDC with insulation tester)
Contact resistance (initial values)
50 mΩ max.
0.49N {50 gf}: 50 mΩ
max.
0.25N {25 gf}: 100 mΩ
max.
30 mΩ max.
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
Dielectric strength (see note 2)
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each terminal and noncurrent-carrying metal parts
Vibration resistance (see note 3)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 400 m/s2 {approx. 40 G} max.
Malfunction: 100 m/s2 {approx. 10 G} max.
Shock resistance (see note 3)
Durability (see note 4)
Mechanical
10,000,000 operations min.
Electrical
50,000 operations min.
100,000 operations min. 200,000 operations min.
Degree of protection
500,000 operations min.
IEC IP40
Degree of protection against electric shock
Class I
Proof tracking index (PTI)
250
Ambient operating temperature
–25 to +85°C
(at ambient humidity
of 60% max.) (with no
icing or condensation)
–25 to +85°C
(at ambient humidity
of 60% max.) (with no
icing or condensation)
–25 to +105°C (at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating humidity
85% max. (for +5 to +35°C)
Weight
Approx. 6.2 g (pin plunger models)
Note 1. The data given above are initial values.
Note 2. The dielectric strength values shown in the table are for models with a Separator.
Note 3. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models, they apply at the total travel
position.
Note 4. For testing conditions, contact your OMRON sales representative.
Terminals/Appearances
(Unit: mm)
Solder Terminals
(A)
(5.5)
(6.5)
2.9
t = 0.5 (10)
Three, solder terminals
6.35
3.2 (see note)
Quick-connect Terminals (#187)
(C2)
Quick-connect Terminals (#250)
(C)
(4.9)
(5.5)
(7.7)
(6.5)
3.2
2.9
t = 0.5 (10)
Three, quick-connect
terminals (#187)
(12.0)
t = 0.8
Three, quick-connect
terminals (#250)
8
6.35
3.2
3.95
4.75±0.1
4.75±0.1
2.4 dia. 1.6 dia.
Note: Indicates the length to the center of the
1.6-dia. holes
6.35±0.1
1.6-dia. terminal hole
1.65-dia. terminal hole
Note. The table below is for the SPDT contact specifications. Two terminals will be available for SPST-NO or SPST-NC contact specifications. For terminal positions,
refer to Contact Form on page 5.
Mounting Holes (Unit: mm)
Two, 3.1-dia. mounting holes or
M3 screw holes
10.3±0.1
22.2±0.1
7
D
3
V
D3V
Miniature Basic Switch
Dimensions (Unit: mm) and Operating Characteristics
The following illustrations and drawings are for quick-connect terminals (#187) (terminals C2). D3V models incorporate terminals A and C. These models are different
from #187 models in terminal size only. Terminals A and C are omitted from the following drawings. Refer to "Terminals/Appearances" on page 7 for these terminals.
The @ in the model number is for the terminal code.
●Pin Plunger Models
D3V-21G-1C4A
D3V-16-1@5
D3V-11-1@5
D3V-11-1@4
D3V-6-1@4
D D3V-6G-1@3
3
V D3V-01-1@3
A
t=0.5
Three, quick-connect
terminals (#187)
Model
Operating Characteristics
Operating Force
Releasing Force
D3V-21G-1C4A
D3V-16-1@5
D3V-11-1@5
D3V-11-1@4
D3V-6-1@4
1.96 N {200 gf}
0.49 N {50 gf}
0.98 N {100 gf}
0.15 N {15 gf}
OF
RF
Max.
Min.
1.23 N {125 gf}
0.20 N {20 gf}
Pretravel
PT
Overtravel
OT
Movement Differential MD
Max.
Min.
Max.
1.2 mm
1.0 mm
0.3 mm
Operating Position
Model
10.3±0.1
15.9 7.2
D3V-161-1@5
D3V-111-1@5
D3V-111-1@4
D3V-61-1@4
1.96 N {200 gf}
0.49 N {50 gf}
0.98 N {100 gf}
0.15 N {15 gf}
Max.
Min.
Max.
1.6 mm
0.8 mm
0.5 mm
D3V-6G1-1@3
OP
D3V-011-1@3
0.49 N {50 gf}
0.05 N {5 gf}
1.6 mm
0.8 mm
0.6 mm
1.6 mm
0.8 mm
0.5 mm
1.6 mm
0.8 mm
0.6 mm
15.2±0.5 mm
●Hinge Lever Models
D3V-21G2-1C4A
D3V-162-1@5
D3V-112-1@5
D3V-112-1@4
D3V-62-1@4
D3V-6G2-1@3
D3V-012-1@3
A
35.6±0.8
3.1+0.13
−0.03
dia. hole 1.6
0.7
Model
Operating Characteristics
D3V-21G2-1C4A
OF
RF
Max.
Min.
0.78 N {80 gf}
0.06 N {6 gf}
Pretravel
PT
Overtravel
OT
Movement Differential MD
Max.
Min.
Max.
4.0 mm
1.6 mm
0.8 mm
PT
8.1
2.8
4
18.8
2.85 4.2
t=0.5
10.3±0.1
15.9 7.2
t=0.5
Three, #187 series tab
2.8
(10)
3.4±0.15 dia. hole
22.2±0.1
27.8
37.8±0.8
D3V-162-1@5
D3V-112-1@5
OP
3.1+0.13
−0.03
D3V-112-1@4
D3V-62-1@4
1.23 N {125 gf}
0.14 N {14 gf}
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
8
10.3
D3V-21G1-1C4A
Pretravel
PT
Overtravel
OT
Movement Differential MD
OP
3.1+0.13
−0.03
3.4±0.15 dia. hole
22.2±0.1
27.8
37.8±0.8
2.8
(10)
t=0.5
Three, #187 series tab
1.23 N {125 gf}
0.20 N {20 gf}
4.2
2.8
4
18.7
2.85
PT
t=0.5
8.1
0.7
Max.
Min.
Operating Position
A
22.1
3.1+0.13
−0.03 dia. hole 1.6
OF
RF
Operating Force
Releasing Force
1.2 mm
1.0 mm
0.4 mm
1.2 mm
1.0 mm
0.3 mm
14.7±0.4 mm
Operating Characteristics
Operating Position
D3V-01-1@3
0.49 N {50 gf}
0.05 N {5 gf}
1.2 mm
1.0 mm
0.4 mm
OP
●Short Hinge Lever Models
D3V-21G1-1C4A
D3V-161-1@5
D3V-111-1@5
D3V-111-1@4
D3V-61-1@4
D3V-6G1-1@3
D3V-011-1@3
Operating Force
Releasing Force
D3V-6G-1@3
OP
10.3
D3V-6G2-1@3
0.59 N {60 gf}
0.06 N {6 gf}
4.0 mm
1.6 mm
1.5 mm
0.29 N {30 gf}
--4.0 mm
1.6 mm
0.8 mm
15.2±1.2 mm
D3V-012-1@3
4.0 mm
1.6 mm
1.5 mm
D3V
Miniature Basic Switch
●Long Hinge Lever Models
D3V-21G3-1C4A
D3V-163-1@5
D3V-113-1@5
D3V-113-1@4
D3V-63-1@4
D3V-6G3-1@3
D3V-013-1@3
A
3.1+0.13
−0.03 dia. hole
59.4±0.8
1.6
8.1
0.7
2.85 4.2
PT
t=0.5
2.8
4
15.9 7.2
18.7
10.3±0.1
OP
+0.13
2.8
(10)
t=0.5
Three, #187 series tab
3.1−0.03
3.4±0.15 dia. hole
22.2±0.1
27.8
10.3
D
3
V
37.8±0.8
Model
Operating Characteristics
Operating Force
Releasing Force
D3V-21G3-1C4A
OF
RF
Max.
Min.
0.44 N {45 gf}
0.03 N {3 gf}
Pretravel
PT
Overtravel
OT
Movement Differential MD
Max.
Min.
Max.
9.0 mm
2.0 mm
2.0 mm
Operating Position
D3V-163-1@5
D3V-113-1@5
0.69 N {70 gf}
0.06 N {6 gf}
Model
Operating Characteristics
9.0 mm
3.2 mm
2.8 mm
9.0 mm
3.2 mm
2.0 mm
15.2±2.6 mm
A
+0.13
3.1−0.03 dia. hole
1.6
PT
2.8
4
18.8
D3V-21G4-1C4A
0.83 N {85 gf}
0.07 N {7 gf}
Pretravel
PT
Overtravel
OT
Movement Differential MD
Max.
Min.
Max.
4.0 mm
1.6 mm
1.4 mm
2.85 4.2
t=0.5
8.1
0.7
Max.
Min.
10.3±0.1
15.9 7.2
2.8
(10)
3.4±0.15 dia. hole
OP
3.1+0.13
−0.03
10.3
22.2±0.1
27.8
37.8±0.8
D3V-164-1@5
D3V-114-1@5
D3V-114-1@4
D3V-64-1@4
1.23 N {125 gf}
0.14 N {14 gf}
D3V-6G4-1@3
0.59 N {60 gf}
0.06 N {6 gf}
OP
D3V-014-1@3
0.29 N {30 gf}
--4.0 mm
1.6 mm
1.5 mm
4.0 mm
1.6 mm
1.4 mm
4.0 mm
1.6 mm
1.5 mm
18.7±1.2 mm
●Short Hinge Roller Lever Models
D3V-21G5-1C4A
D3V-165-1@5
D3V-115-1@5
D3V-115-1@4
D3V-65-1@4
D3V-6G5-1@3
D3V-015-1@3
A
+0.13
3.1−0.03
20.1±0.8
Model
Operating Characteristics
PT
dia. hole 1.6
8.1
0.7
4.8
2.8
OP
10.3±0.1
4
2.8
(10)
3.4±0.15 dia. hole
22.2±0.1
27.8
37.8±0.8
3.1+0.13
−0.03
D3V-21G5-1C4A
D3V-165-1@5
D3V-115-1@5
D3V-115-1@4
D3V-65-1@4
2.35 N {240 gf}
0.49 N {50 gf}
1.18 N {120 gf}
0.15 N {15 gf}
OF
RF
Max.
Min.
1.42 N {145 gf}
0.2 N {20 gf}
Pretravel
PT
Overtravel
OT
Movement Differential MD
Max.
Min.
Max.
1.6 mm
0.8 mm
0.5 mm
5.1
t=0.5
15.9 7.2
18.8
t=0.5
Three, #187 series tab
Operating Position
D3V-013-1@3
0.20 N {20 gf}
---
32.5±0.8
OF
RF
Operating Force
Releasing Force
0.34 N {35 gf}
---
+2.6
15.2 −3.2 mm
OP
t=0.5
Three, #187 series tab
Operating Position
D3V-6G3-1@3
9.0 mm
2.0 mm
2.8 mm
●Simulated Roller Lever Models
D3V-21G4-1C4A
D3V-164-1@5
D3V-114-1@5
D3V-114-1@4
D3V-64-1@4
D3V-6G4-1@3
D3V-014-1@3
Operating Force
Releasing Force
D3V-113-1@4
D3V-63-1@4
OP
1.6 mm
0.8 mm
0.6 mm
10.3
D3V-6G5-1@3
D3V-015-1@3
0.59 N {60 gf}
0.06 N {6 gf}
1.6 mm
0.8 mm
0.5 mm
1.6 mm
0.8 mm
0.6 mm
20.7±0.6 mm
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
9
D3V
Miniature Basic Switch
●Hinge Roller Lever Models
D3V-21G6-1C4A
D3V-166-1@5
D3V-116-1@5
D3V-116-1@4
D3V-66-1@4
D3V-6G6-1@3
D3V-016-1@3
A
33.0±0.8
+0.13
3.1−0.03 dia. hole
8.1
Model
Operating Characteristics
Operating Force
Releasing Force
2.8
OP
10.3±0.1
15.9 7.2
18.7
+0.13
D3V-21G6-1C4A
Max.
Min.
0.79 N {80 gf}
0.05 N {5 gf}
Pretravel
PT
Overtravel
OT
Movement Differential MD
Max.
Min.
Max.
4.0 mm
1.6 mm
0.8 mm
2.8
(10)
D3V-166-1@5
D3V-116-1@5
OP
3.4±0.15 dia. hole
3.1−0.03
10.3
22.2±0.1
27.8
37.8±0.8
D3V-116-1@4
D3V-66-1@4
1.23 N {125 gf}
0.14 N {14 gf}
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
10
4.8
0.7
OF
RF
Operating Position
5.1
PT
t=0.5
4
t=0.5
Three, #187 series tab
D
3
V
1.6
D3V-6G6-1@3
0.59 N {60 gf}
0.06 N {6 gf}
0.29 N {30 gf}
--4.0 mm
1.6 mm
0.8 mm
4.0 mm
1.6 mm
1.5 mm
20.7±1.2 mm
D3V-016-1@3
4.0 mm
1.6 mm
1.5 mm
D3V
Miniature Basic Switch
Precautions
★Please refer to "Common Precautions" for correct use.
Cautions
●Handling
Be careful not to drop the switch. Doing so may cause damage to
the switch's internal components because it is designed for a
small load.
Correct Use
D
3
V
●Using Micro Loads
Use two M3 mounting screws with an appropriate screwdriver to
mount the switch. Tighten the screws to a torque of 0.39 to 0.59
N·m {4 to 6 kgf·cm}.
Using a model for ordinary loads to open or close the contact of
a micro load circuit may result faulty contact. Use models that
operate in the following range. However, even when using micro
load models within the operating range shown below, if inrush
current occurs when the contact is opened or closed, it may
increase contact wear and so decrease durability. Therefore,
insert a contact protection circuit where necessary.
The minimum applicable load is the N-level reference value. This
value indicates the malfunction reference level for the reliability
level of 60% (λ 60). The equation, λ 60 = 0.5 × 10-6/operations
indicates that the estimated malfunction rate is less than
1/2,000,000 operations with a reliability level of 60%.
●Mounting Direction
Mount lever-operated switches with a maximum operating force
of 0.49 N in a direction where the actuator weight will not be
applied to the switch. Since the switch is designed for a small
load, its resetting force is small. Therefore, resetting failure may
occur if unnecessary load is applied to the switch.
●Insulation Distance
According to EN61058-1, the minimum insulation thickness for
this switch should be 1.1 mm and minimum clearance distance
between the terminal and mounting plate should be 1.9 mm. If
the insulation distance cannot be provided in the product
incorporating the switch, either use a switch with insulation
barrier or use a Separator to ensure sufficient insulation
distance.
Voltage (V)
●Mounting
Operating range
for micro load
models D3V-01
Operating
range for
generalload models
Inoperable
range
Current (mA)
●Solder Terminal Approval Conditions
Soldering iron can be used.
Soldering hook hole available.
Soldering terminal types 1 and 2 are met.
Actuator (Sold Separately)
Various Actuators are available as shown on D3V/V/VX/D2MV/D2RV Common Accessories.
Connector (Sold Separately)
Refer to Terminal Connectors.
11
D3V
Miniature Basic Switch
D
3
V
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
12
Contact: www.omron.com/ecb
Cat. No.B103-E1-05
0815(0207)(O)