EE-SX47/67 - OMRON Industrial Automation

Slot-type Photomicrosensor (Non-modulated) *1
EE-SX47/67
CSM_EE-SX47/67_DS_E_11_1
Global Standard Slot-type
photomicrosensors with 50- to
100-mA direct switching capacity.
• Series includes models that enable switching between
dark-ON and light-ON operation.
• Response frequency as high as 1 kHz.
• Easy operation monitoring with bright light indicator.
• Wide operating voltage range: 5 to 24 VDC
• Models in which the light indicator turns ON for dark-ON
operation are also available.
• A wide range of variations in eight different shapes.
• Flexible robot cable is provided as a standard feature. *2
Be sure to read Safety Precautions on
page 5.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
*1. Pre-wired Models are available only in the EE-SX67 Series.
*2. Only for Pre-wired Models.
Ordering Information
Connector
Appearance
Infrared light
Sensing Connectmethod ing method
Sensing distance
Standard
L-shaped
T-shaped,
slot center
7 mm
Closemounting
Closemounting
T-shaped,
slot center
10 mm
Throughbeam
type
(with slot)
Connector
(4 poles)
5 mm
Output
configuration
Indicator mode
Model
NPN output
PNP output
Dark-ON/Light-ON Incident light
(selectable) *3 *4 No incident light
EE-SX670
EE-SX670P
EE-SX670A
EE-SX670R
Light-ON
EE-SX470
Incident light
---
Dark-ON/Light-ON Incident light
(selectable) *3 *4 No incident light
EE-SX671
EE-SX671P
EE-SX671A
EE-SX671R
Light-ON
EE-SX471
---
Dark-ON/Light-ON Incident light
(selectable) *3 *4 No incident light
EE-SX672
EE-SX672P
EE-SX672A
EE-SX672R
Light-ON
EE-SX472
---
Dark-ON/Light-ON Incident light
(selectable) *3 *4 No incident light
EE-SX673
EE-SX673P
EE-SX673A
EE-SX673R
Light-ON
EE-SX473
---
Dark-ON/Light-ON Incident light
(selectable) *3 *4 No incident light
EE-SX674
EE-SX674P
EE-SX674A
EE-SX674R
Light-ON
Incident light
EE-SX474
---
Dark-ON/Light-ON
Incident light
(selectable) *3 *4
EE-SX675
EE-SX675P
Dark-ON/Light-ON
Incident light
(selectable) *3 *4
EE-SX676
EE-SX676P
Dark-ON/Light-ON
Incident light
(selectable) *3 *4
EE-SX677
EE-SX677P
Incident light
Incident light
Incident light
(slot width)
F-shaped
R-shaped
*3. Dark-ON when the L terminal of the connector is opened, and light-ON when the L terminal and positive (+) terminal are connected. Do not connect the L terminal
to 0 V when using dark-ON operation. When using light-ON, it is useful to select the connector EE-1001-1. The L terminal and positive (+) terminal of this connector
are connected in advance.
*4. If you do not use the L terminal wire ((2) pink) when you use a Connector with Cable for an EE-1006 or EE-1010-series Photomicrosensor, noise may affect the
Photomicrosensor. To prevent the effects of noise, cut the unused L terminal wire at the base of the connector and wrap it with insulating tape to prevent it from
coming in contact with other terminals.
1
EE-SX47/67
Pre-wired Models
Appearance
Infrared light
Sensing
method
Sensing distance
Output
configuration
Indicator
mode
Connecting
method
Model
NPN output
PNP output
Standard
EE-SX670-WR 1M
EE-SX670P-WR
1M
EE-SX671-WR 1M
EE-SX671P-WR
1M
EE-SX672-WR 1M
EE-SX672P-WR
1M
EE-SX673-WR 1M
EE-SX673P-WR
1M
EE-SX674-WR 1M
EE-SX674P-WR
1M
EE-SX675-WR 1M
EE-SX675P-WR
1M
EE-SX676-WR 1M
EE-SX676P-WR
1M
EE-SX677-WR 1M
EE-SX677P-WR
1M
L-shaped
T-shaped,
slot center
7 mm
Closemounting
Throughbeam
type
(with slot)
Closemounting
Dark-ON/
Light-ON
5 mm
(slot width) (selectable)
*1 *2
Incident
light
Pre-wired
Models (1m)
T-shaped,
slot center
10 mm
F-shaped
R-shaped
*1. Dark-ON operation can be used when the L terminal is left unconnected or Light-ON operation can be used when the L terminal and positive (+) terminal are
connected to each other. Do not connect the L terminal to 0 V when using dark-ON operation.
*2. If you do not use the L terminal wire ((2) pink) when you use a Connector with Cable for an EE-1006 or EE-1010-series Photomicrosensor, noise may affect the
Photomicrosensor. To prevent the effects of noise, cut the unused L terminal wire at the base of the connector and wrap it with insulating tape to prevent it from
coming in contact with other terminals.
Accessories (Order Separately) Connector Models
Type
Cable
length
Connector
1m
Connector with Cable
2m
Connector with Robot
Cable
Connector Hold-down Clip
1m
2m
Model
EE-1001
EE-1001-1
EE-1009
EE-1006 1M
EE-1010 1M
EE-1006 2M
EE-1010 2M
EE-1010-R 1M
EE-1010-R 2M
EE-1006A
Remarks
L terminal and positive (+) terminal are already short-circuited.
For EE-1006 only.
* Refer to Accessories for details.
2
EE-SX47/67
Ratings and Specifications
Type
Standard
L-shaped
T-shaped,
slot center
7 mm
EE-SX672
EE-SX672A
EE-SX472
EE-SX672WR
EE-SX672P
EE-SX672R
EE-SX672PWR
T-shaped,
slot center
10 mm
Close-mounting
F-shaped
R-shaped
EE-SX670
EE-SX671
EE-SX673
EE-SX674
Connector
EE-SX670A
EE-SX671A
EE-SX673A
EE-SX674A
EE-SX675
EE-SX676
EE-SX677
models
EE-SX470
EE-SX471
EE-SX473
EE-SX474
Pre-wired EE-SX670EE-SX671EE-SX673EE-SX674EE-SX675EE-SX676EE-SX677models WR
WR
WR
WR
WR
WR
WR
Connector EE-SX670P
EE-SX671P
EE-SX673P
EE-SX674P
EE-SX675P
EE-SX676P
EE-SX677P
models EE-SX670R
EE-SX671R
EE-SX673R
EE-SX674R
PNP
models
Pre-wired EE-SX670PEE-SX671PEE-SX673PEE-SX674PEE-SX675PEE-SX676PEE-SX677PItem
models WR
WR
WR
WR
WR
WR
WR
Sensing distance
5 mm (slot width)
Sensing object
Opaque: 2 × 0.8 mm min.
Differential distance
0.025 mm
Light source
Infrared LED with a peak wavelength of 940 nm
Indicator *1
Light indicator (red) (turns ON when light is interrupted for models with A or R suffix)
Supply voltage
5 to 24 VDC ±10%, ripple (p-p): 10% max.
Current consumption
12 mA max. (Connector models, L terminal open), 35 mA max. (NPN pre-wired models), 30 mA max. (PNP pre-wired models)
NPN open collector: 5 to 24 VDC, 100 mA max.
100 mA load current with a residual voltage of 0.8 V max.
40 mA load current with a residual voltage of 0.4 V max.
Control output
OFF current (leakage current): 0.5 mA max.
PNP open collector: 5 to 24 VDC, 50 mA max.
50 mA load current with a residual voltage of 1.3 V max.
OFF current (leakage current): 0.5 mA max.
Protection circuits
Load short circuit protection (Connector models), No circuit protection (Pre-wired models)
Response frequency *2
1 kHz min. (3 kHz average)
Ambient illumination
1,000 lx max. with fluorescent light on the surface of the receiver.
Ambient temperature range Operating: −25 to +55°C, Storage: −30 to +80°C (with no icing or condensation)
Ambient humidity range
Operating: 5% to 85%, Storage: 5% to 95% (with no icing or condensation)
Destruction: 20 to 2,000 Hz (peak acceleration: 100 m/s2)
Vibration resistance
1.5-mm double amplitude for 2 h (4-min periods) each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection
IEC60529 IP50
Connector Models (direct soldering possible), Pre-wired Models (Standard cable length: 1 m),
Connecting method
Models with Connectors (Standard cable length: 0.1 m)
Approx. 3.1 g Approx. 3 g
Approx. 2.4 g Approx. 2.3 g Approx. 3 g
Approx. 2.7 g Approx. 2.2 g Approx. 2.2 g
Wei- Connector models
ght
Pre-wired models
Approx. 18.9 g Approx. 17.3 g Approx. 17.8 g Approx. 16.8 g Approx. 17.1 g Approx. 18.3 g Approx. 16.9 g Approx. 16.9 g
Polybutylene phthalate (PBT)
Ma- Case
teri- Cover
Polycarbonate
al
Emitter/receiver
NPN
models
*1. The indicator is a GaP red LED (peak wavelength: 690 nm).
*2. The response frequency was measured by detecting the rotating disk shown at the right.
Disk
1 mm
2.1 mm
1 mm
t = 0.2 mm
3
EE-SX47/67
Engineering Data (Reference Value)
Sensing Position Characteristics
Dark-ON
Tr ON
Repeated Sensing Position Characteristics
Dark-ON
Tr ON
d
Output level transistor
Sensing Position Characteristics
OFF
Δd2
Δd3
Δd1
Δd4
d
Δd5
d
ON
Tr OFF
0
1.0
2.0
3.0
4.0
5.0
6.0
Tr OFF
0
1.0
Distance d (mm)
2.0
3.0
4.0
5.0
Ta = −25°C Ta = 55°C Ta = 25°C
0
6.0
Distance d (mm)
3.20
3.22
3.24
3.26
3.28
Distance d (mm)
Vcc =12 V, No. of repetitions: 20, Δd1 = 0.002 mm,
Δd2 = 0.004 mm, Δd3 = 0.005 mm, Δd4 = 0.02 mm,
Δd5 = 0.04 mm
Note: The data applies to dark status. Operation may
be affected by external light interference or light
coming through the sensing object.
I/O Circuit Diagrams
NPN Output
Model
Output
configuration
Light-ON
EE-SX67@
EE-SX67@-WR
Incident
Interrupted
ON
Light indicator
(red)
OFF
ON
Output
transistor
OFF
Operates
Load
(e.g., relay) Releases
Terminal
connections
L
Incident
Interrupted
ON
Light indicator
(red)
OFF
ON
Output
transistor
OFF
Operates
Load
(e.g., relay) Releases
Short-circuited
between
L terminal and
positive
terminal
Dark-ON
Incident
Interrupted
Light indicator
ON
(red)
OFF
Output
ON
transistor
OFF
Operates
Load
(e.g., relay) Releases
Open between
L terminal and
positive
terminal
*1 *2
Light-ON
Incident
Interrupted
ON
Light indicator
(red)
OFF
ON
Output
transistor
OFF
Operates
Load
(relay)
Releases
EE-SX670A
EE-SX671A
EE-SX672A
EE-SX673A
EE-SX674A
*
(red)
Open between
L terminal and
positive
terminal
*1 *2
Light-ON
Output circuit
EE-SX67@
Short-circuited
between
EE-SX67@A
L terminal and
positive
terminal
Light indicator
Incident
Interrupted
ON
Light indicator
(red)
OFF
ON
Output
transistor
OFF
Operates
Load
(e.g., relay) Releases
Dark-ON
EE-SX470
EE-SX471
EE-SX472
EE-SX473
EE-SX474
Timing charts
Main
circuit
Load
OUT
IC (Control output)
100 mA max.
5 to
24 VDC
*The terminal arrangement depends on the model.
Check the dimensional diagrams.
EE-SX67@-WR
*
Light indicator
(red)
L
Main
circuit
Load
OUT
IC (Control output)
100 mA max.
5 to
24 VDC
*The terminal arrangement depends on the model.
Check the dimensional diagrams.
Light indicator
(red)
Load
---
Main
circuit
OUT
IC
5 to
24 VDC
*1. Do not connect the L terminal to 0 V when using dark-ON operation.
*2. If you do not use the L terminal wire ((2) pink) when you use a Connector with Cable for an EE-1006 or EE-1010-series Photomicrosensor, noise may affect the
Photomicrosensor. To prevent the effects of noise, cut the unused L terminal wire at the base of the connector and wrap it with insulating tape to prevent it from
coming in contact with other terminals.
4
EE-SX47/67
PNP Output
Output
configuration
Model
Timing charts
Terminal
connections
Output circuit
Incident
Interrupted
Light-ON
Light indicator
(red)
Output
transistor
Load
(relay)
EE-SX67@P
EE-SX67@P-WR
ON
OFF
ON
OFF
Operates
Short-circuited
between
L terminal and
positive
terminal
Releases
Incident
Interrupted
Dark-ON
Light indicator
(red)
Output
transistor
Load
(relay)
ON
OFF
ON
OFF
Operates
Open between
L terminal and
positive
terminal
*1 *2
L
Releases
EE-SX670R
EE-SX671R
EE-SX672R
EE-SX673R
EE-SX674R
Light indicator
(red)
Output
transistor
ON
OFF
ON
OFF
Operates
5 to
24 VDC
OUT
IC
Main
circuit
Incident
Interrupted
Light-ON
*
Light indicator
(red)
Load
Short-circuited
between
L terminal and
positive
terminal
*The terminal arrangement depends on the model.
Check the dimensional diagrams.
Load
(e.g., relay) Releases
Dark-ON
Incident
Interrupted
ON
Light indicator
(red)
OFF
ON
Output
transistor
OFF
Operates
Load
(e.g., relay) Releases
Open between
L terminal and
positive
terminal
*1 *2
*1. Do not connect the L terminal to 0 V when using dark-ON operation.
*2. If you do not use the L terminal wire ((2) pink) when you use a Connector with Cable for an EE-1006 or EE-1010-series Photomicrosensor, noise may affect the
Photomicrosensor. To prevent the effects of noise, cut the unused L terminal wire at the base of the connector and wrap it with insulating tape to prevent it from
coming in contact with other terminals.
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Precautions for Correct Use
Make sure that this product is used within the rated ambient
environment conditions.
● Installation
• When direct soldering to the terminals, use the following guidelines.
Precautions for Safe Use
● Operating Environment
These Photomicrosensors have an IP50 (conforms to IEC) enclosure
and do not have a water-proof or dust-proof structure. Therefore, do
not use them in applications in which the sensor will be subjected to
splashes from water, oil, or any other liquid. Liquid entering the
Sensor may result in malfunction.
Soldering Conditions
Item
Soldering
iron
Temper- Permissible
ature
time
350°C
max.
3 s max.
Remarks
The portion between the base of the
terminals and the position 1.5 mm from
the terminal base must not be soldered.
• The terminal base uses a polycarbonate resin, which could be deformed by
excessive soldering heat, resulting in damage to the product's functionality.
● Lot Number and Model Number Legend
In the following diagrams, 343U
indicates the lot number and factory
where the product was
manufactured. Do not include this
code with the model number when
ordering.
The QR code on connector models
is used by OMRON only.
EE-SX@70@
Model number
EE-SX670
343U
Lot number and factory code
5
EE-SX47/67
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
Sensors
EE-SX670/670P
EE-SX670A/670R
EE-SX470
EE-SX671/671P
EE-SX671A/671R
EE-SX471
Terminal Arrangement
(1)
Vcc
(2)
L
(3)
OUT
Terminal Arrangement
(1)
L*
OUTPUT
(4)
Vcc
(2)
L
L*
(3)
OUT
OUTPUT
(4)
GND (0 V)
GND (0 V)
* Pin 2 is not used for the EE-SX471.
* Pin 2 is not used for the EE-SX470.
26.2
25.4
19
19
Two, 3.2 dia.
holes
Four, R2
3.2
6.95
14.5
3
19
13.4
5
Four, R1
3
Four, R1
6.4
0.8
6.2
3.8
Indicator window
1
2 3
4
2.54
9
Optical
axis
2
13
6.35
0.8
13.4
5
13.8
8.4
13.2
6.2
9
Two,
3.8 dia.
holes
Indicator window
5.5
3.8
Optical axis
Two, 3.2 dia. holes
8.3
9
2
3 4
0.3
2.54
EE-SX672/672P
EE-SX672A/672R
EE-SX472
(1)
Vcc
7.2
6.2
0.7
0.7
Terminal Arrangement
15.5
2.1 0.3
7.2
3.6
1
2
13
13.4
19
0.6
EE-SX673/673P
EE-SX673A/673R
EE-SX473
6.95
Terminal Arrangement
(1)
Vcc
(2)
L
L*
(2)
L
L*
(3)
OUT
OUTPUT
(3)
OUT
OUTPUT
(4)
GND (0 V)
(4)
* Pin 2 is not used for the EE-SX472.
GND (0 V)
* Pin 2 is not used for the EE-SX473.
13.7
3
26
12.6
6.4
6.3
12.8
(6.65)
3.5
Two, R1
Two, 3.2 dia. holes
7
7
13.4
0.8
13.4
5
5
2
Optical axis
9
4.3
13
Optical axis
9
Indicator window
3
Four, R1.6 22.2
0.8
14.4
22.2
8.4
6.2
2
2.8
6.3
6.3
2.5
Four, R1
6.2
3.8
6.2
2.5
1
0.3
2 3
0.7
19
4.9
4
2.54
3.8
Indicator window
1
2 3
4
2.54
0.3
0.7
13
6
EE-SX47/67
EE-SX674/674P
EE-SX674A/674R
EE-SX474
EE-SX675/675P
Terminal Arrangement
Terminal Arrangement
(1)
Vcc
(1)
Vcc
(2)
L
L*
(2)
L
L
(3)
OUT
OUTPUT
(3)
OUT
OUTPUT
GND (0 V)
(4)
(4)
GND (0 V)
* Pin 2 is not used for the EE-SX474.
16.7
4
Optical axis
Two, R1
Two, 3.5 dia. holes
7
6.35 26
Indicator window
7
10
21.5 6.95
3
0.8
3
Sensing
window
3.8
6.2
13.4
5
Optical axis
9
1
2
3
13
2.54
13
5
0.8 0.1
3.7
(R)
Optical axis
2.1
22.2
3.2
15.5
0.3
2.5
3.8
6.2
0.7
0.3
6.2
2.6
0.7
1
2
3
4
2.54
19.5
13
16.7
0.6
13.6
3
8.4
2
(9.3)
(R)
6
6.3
(2.9)
Indicator window
2
4
EE-SX676/676P
EE-SX677/677P
Terminal Arrangement
(1)
(1)
Vcc
(2)
L
L
(2)
L
L
(3)
OUT
OUTPUT
(3)
OUT
OUTPUT
GND (0 V)
(4)
(4)
13.7
Terminal Arrangement
Vcc
Optical axis
GND (0 V)
13.7
Optical axis
2.5
2.5
13.2
7
13.2
6.35
6.35
13.4
7
7
0.8
5
Optical axis
9
Indicator window
8.4
13.4
5
0.8
Optical axis
22.2
7
Sensing
window
2
9
3
13.6
9
2
22.2
Sensing
window
7
8.4
3
7 13.6
2.5
6.2
Indicator window
9
2.5
3.3
3.8
3.3
0.3
0.3
1 2 3 4
2.54
Two, 3.5 dia. holes
0.7
0.7
6.2
3.8
1 2 3 4
Two, 3.5 dia. holes
2.54
7
EE-SX47/67
EE-SX671-WR/671P-WR
EE-SX670-WR/670P-WR
Terminal Arrangement
Brown
Terminal Arrangement
Vcc
Brown
Vcc
Pink
L
Pink
L
Blue
GND (0 V)
Blue
GND (0 V)
Black
OUTPUT
Black
OUTPUT
26.2
R3.5
R1
Optical axis
19
Optical axis
6.95
3.2
6.95
3
R1
19
18.7
3
3.2 dia.
Indicator window
25.4
2
13.4
6.35
Optical axis
5
0.8
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
13.4
2
9
11.2
8.4
26.2
6.35
13.4
5
Sensing
window
13.8
3
Optical axis
11
5.5
2.5
Indicator window
9
4.6 dia.
2.8
6.2
7.2
3.8 dia.
4.6 dia.
2
2
9
15.5
0.8
Sensing
window
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
3.6
EE-SX672-WR/672P-WR
19
3.2 dia.
EE-SX673-WR/673P-WR
Terminal Arrangement
Brown
Terminal Arrangement
Vcc
Brown
Vcc
Pink
L
Pink
L
Blue
GND (0 V)
Blue
GND (0 V)
Black
OUTPUT
Black
OUTPUT
13.7
7
Optical axis
12.6
6.3
12.8
Optical axis
(6.65)
3.5
R1
3
7
3.2 dia.
13.4
6.35
5
13.4
5
0.8
Sensing
window
Optical axis
2
2.5
13
9
9
4.3
Indicator
window
R1.6
26.2
14.4
2.5
2
4.6 dia.
19
Sensing
window
8.4
8.9
R1
2 dia.
2
26.2
6.2
10.3
0.8
Optical axis
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
2.8
Indicator window
3
2
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
4.6 dia.
26
8
EE-SX47/67
EE-SX675-WR/675P-WR
EE-SX674-WR/674P-WR
Terminal Arrangement
Brown
3.5 dia.
Terminal Arrangement
Vcc
Brown
L
Pink
L
Blue
GND(0V)
Blue
GND(0V)
Black
OUTPUT
Black
OUTPUT
R1
7
Vcc
Pink
10
Optical axis
6.35 26
7
7
4
6.95
25.7
Optical axis 3
3
13.4
5
19.5
0.8
Sensing
window
2
Optical axis
2
Indicator window
9
(R)
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
Indicator window
13
3
26.2 8.4
6 3.2
13.6
5
Optical axis
0.8
Sensing
window
(2.9)
3.7
2.5
10.3
(R)
2
9
4.6 dia.
2
15.5
4.6 dia.
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
2.6
6.2
2.8
13.4
16.7
EE-SX676-WR/676P-WR
EE-SX677-WR/677P-WR
Terminal Arrangement
Brown
Terminal Arrangement
Vcc
Brown
Vcc
Pink
L
Pink
L
Blue
GND(0V)
Blue
GND(0V)
Black
OUTPUT
Black
OUTPUT
Optical axis
2.5
Optical axis
2.5
7
7
13.7
13.7
13.2
6.4
13.2
Optical axis
6.4
13.4
5
7
9
8.4
3
Sensing
window
13.4
5
Indicator window
9
9
0.8
26.2 8.4
26.2
13
Optical axis
2
2
0.8
9
Sensing
window
7
7
7
2.5
2.5
3
13
3.3
3.3
Indicator window
2
4.6 dia.
4
4
3.5 dia.
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
3.5
4.6 dia.
2
Robot cable of 2.8 dia., 4 cores,
(0.15 mm2 with 0.8 mm dia. insulator);
Standard length: 1 m
9
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.