CJ1W-PA/PD

CJ-series Power Supply Unit
CJ1W-PA/PD
CSM_CJ1W-PA_PD_DS_E_5_1
Equipped with the RUN output for
checking the operation status, as
well as the replacement
notification function for easy
maintenance.
Lineup of five models including the
AC power supply (25W).
CJ1W-PA205C
CJ1W-PA202
• Stable power supply is available from the CJ-series
CPU Unit to each I/O Units via the dedicated bus. The
most suitable Power Supply Unit can be selected among various I/O specifications and/or options.
Features
• The replacement notification function can prevent an overflow of the system due to the power lifetime. (CJ1W-PA205C only)
• Power Supply Unit provides wide variations according to the system scale up to maximum 25 W.
• Power Supply Unit provides wide variations according to the power supply (100 to 240 V AC/ 24 V DC) status.
• The output contact during operation enables you to check the CPU operation. (CJ1W-PA205R only)
• Conforming to the SEMI-F47 Standard. *
* AC input type, 200 V min. input.
1
CJ1W-PA/PD
Ordering Information
International Standards
• The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus
(Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
• Contact your OMRON representative for further details and applicable conditions for these standards.
Power Supply Units
Output capacity
Product name
Power supply
voltage
5-VDC
output
capacity
5A
AC Power
Supply
Unit
24-VDC
output
capacity
0.8 A
Total power
consumption
Options
24-VDC
service
power
supply
RUN
output
Maintenance
forecast
monitor
No
Yes
CJ1W-PA205C
Yes
No
CJ1W-PA205R
Model
Standards
25 W
100 to 240
VAC
UC1, N, L,
CE
DC Power
Supply
Unit
2.8 A
0.4 A
14 W
5A
0.8 A
2A
0.4 A
No
No
No
CJ1W-PA202
25 W
No
No
CJ1W-PD025
19.6 W
No
No
CJ1W-PD022
24 VDC
UC1, CE
Note: This unit cannot be used with the Machine Automation Controller NJ-series.
Accessories
There is no accessory for the CJ series Power Supply Unit.
2
CJ1W-PA/PD
Specifications
Item
Model
Specifications
CJ1W-PA205R
CJ1W-PA205C
CJ1W-PA202
CJ1W-PD025
CJ1W-PD022
Supply voltage
100 to 240 V AC (wide-range), 50/60 Hz
24 VDC
Operating voltage
and frequency
ranges
85 to 264 V AC, 47 to 63 Hz
19.2 to 28.8 V DC
21.6 to 26.4 V DC
Power consumption
100 VA max.
50 VA max.
50 W max.
35 W max.
At 100 to 120 V AC:
15 A/8 ms max. for cold start at room temperature
At 200 to 240 V AC:
30 A/8 ms max. for cold start at room temperature
At 100 to 120 V AC:
20 A/8 ms max. for cold
start at room temperature At 24 V DC:
At 200 to 240 V AC:
30 A/20 ms max. for cold start
40 A/8 ms max. for cold
start at room temperature
5.0 A, 5 V DC (including supply to CPU Unit)
2.8 A, 5 V DC
(including supply to CPU
Unit)
Inrush current *1
Output capacity *7
0.4 A, 24 V DC
0.8 A, 24 V DC
0.4 A, 24 V DC
Total: 25 W max.
Total: 14 W max.
Total: 25 W max.
Total: 19.6 W max.
Not provided.
RUN output *2
Contact configuration:
SPST-NO
Switch capacity:
250 V AC, 2 A (resistive
load)
Not provided.
120 V AC, 0.5 A
(inductive load), 24 V DC,
2A (resistive load)
24 V DC, 2 A (inductive load)
With Alarm output (opencollector output)
30 V DC max., 50 mA
max.
Not provided.
20 MΩ min. (at 500 V DC)
between AC external and
GR terminals
*3
• 20 MΩ min. (at 500 V
DC) between all
external terminals and
GR terminal *3, and
between all alarm
output terminals.
• 20 MΩ 1 min. (at 250 V
DC) between all alarm
output terminals and
GR terminal *3.
20 MΩ min. (at 500 V DC)
between AC external and
GR terminals
*3
20 MΩ min. (at 500 V DC)
between DC external and
GR terminals
*3
2,300 V AC 50/60 Hz
for 1 min between AC
external and GR terminals
*3
Leakage current: 10 mA
max.
• 2,300 VAC, 50/60 Hz for
1 min between all
external terminals and
GR terminal *3 and
between all alarm
output terminals with a
leakage current of 10
mA max.
• 1,000 V AC, 50/60 Hz
for 1 min between all
alarm output terminals
and GR terminal *3 with
a leakage current of 10
mA max.
2,300 V AC 50/60 Hz
for 1 min between AC
external and GR terminals
*3
Leakage current: 10 mA
max.
1,000 V AC, 50/60 Hz for
1 min between DC
external and GR terminals
*3
Leakage current: 10 mA
max.
Replacement
Not provided.
notification function
Dielectric strength
*4
2.0 A, 5 V DC
(including supply to CPU
Unit)
0.8 A, 24 V DC
Output terminal
(service supply)
Insulation
resistance
5.0 A, 5 V DC
(including supply to CPU
Unit)
−
*6
−
*6
1,000 V AC, 50/60 Hz for 1 minute between DC external and GR terminals *3
Leakage current: 10 mA max.
Noise immunity
2 kV on power supply line (conforming to IEC61000-4-4)
Vibration resistance
Conforms to IEC60068-2-6
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz
Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min)
Shock resistance
Conforms to IEC60068-2-27
147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units)
Ambient operating
temperature
0 to 55°C
Ambient operating
humidity
10% to 90% (with no
condensation)
Atmosphere
Must be free from corrosive gases.
Ambient storage
temperature
−20 to 70°C (excluding
battery)
Grounding
Less than 100 Ω
Enclosure
Mounted in a panel.
Weight
All models are each 5 kg max.
10% to 90% (with no
condensation)
*5
−20 to 75°C
*5
10% to 90% (with no condensation)
−20 to 75°C (excluding battery)
3
CJ1W-PA/PD
Item
Specifications
Model
CJ1W-PA205R
CJ1W-PA205C
CJ1W-PA202
CJ1W-PD025
CJ1W-PD022
CPU Rack
dimensions
90.7 to 466.7 × 90 × 65 mm (W × H × D) (not including cables)
Note: W = a + b + 20 × n + 31 × m + 14.7
a: Power Supply Unit: PA205R and PA205C = 80; PA202 = 45; PD025 = 60; PD022=27
b: CPU Unit: CJ1-H or CJ1 = 62; CJ1M-CPU1@ = 31; CJ1M-CPU2@ = 49
The total width is given by the following: W = 156.7 + n × 20 + m × 31, where n is the number of 32-point I/O Units or I/O Control Units
and m is the number of other Units.
Safety measures
Conforms to cULus and EC Directives.
*1. Disconnect the Power Supply Units LG terminal from the GR terminal when testing insulation and dielectric strength. Testing the insulation and
dielectric strength with the LG terminal and the GR terminals connected will damage internal circuits in the CPU Unit.
*2. Supported only when mounted to CPU Rack.
*3. The inrush current is given for a cold start at room temperature. The inrush control circuit uses a thermistor element with a low-temperature
current control characteristic. If the ambient temperature is high or the PLC is hot-started, the thermistor will not be sufficiently cool, and the
inrush currents given in the table may be exceeded by up to twice the given values. When selecting fuses or breakers for external circuits,
allow sufficient margin in shut-off performance.
*4. Maintain an ambient storage temperature of −25 to 30°C and relative humidity of 25% to 70% when storing the Unit for longer than 3 months
to keep the replacement notification function in optimum working condition.
*5. Change the applied voltage gradually using the adjuster on the Tester. If the full dielectric strength voltage is applied or turned OFF using the
switch on the Tester, the generated impulse voltage may damage the Power Supply Unit.
*6. CJ1W-PD022 is not insulated between the primary DC power and secondary DC power.
*7. Internal components in the Power Supply Unit will deteriorate or be damaged if the Power Supply Unit is used for an extended period of time
exceeding the power supply output capacity or if the outputs are shorted.
External Interface
CJ1W-PA205R
POWER Indicator
Lit when 5 V are being output from the Power Supply Unit.
PA205R
POWER
External connection terminals
L1
AC100-240V
INPUT
AC input
L2/N
LG
GR
RUN
OUTPUT
AC240V
DC24V
RUN output
CJ1W-PA205C
Replacement notification display
CJ1W-PA205C
Terminals
external connect
POWER
AC100-240V
INPUT
POWER indicator
Lit: 5-V output from Power Supply Unit.
Years
L1
AC input
TEST
L2/N
LG
ALARM
OUTPUT
DC30V,50mA
GR
NORMAL:ON
ALARM :OFF
L
+
TEST switch
The TEST switch can be used to
temporarily turn OFF the alarm output
that notifies when replacement is
needed.
NC
NC
Alarm output
(replacement notification output)
4
CJ1W-PA/PD
CJ1W-PA202
POWER Indicator
Lit when 5 V are being output from the Power Supply Unit.
PA202
POWER
External connection terminals
L1
AC100
-240V
INPUT
AC input
L2/N
LG
GR
NC
NC
CJ1W-PD025
POWER Indicator
Lit when 5 V are being output from the Power Supply Unit.
PD025
POWER
External connection terminals
DC24V+
INPUT
DC input
LG
GR
NC
NC
CJ1W-PD022
PD022
POWER
External
connection
terminals
DC24V
INPUT
DC input
POWER Indicator
Lit when 5 V are being output
from the Power Supply Unit.
+
NC
GR
5
CJ1W-PA/PD
AC Input
Supply 100 to 240 V AC (allowable: 85 to 264 V AC). (Voltage selection is not required.)
DC Input
Supply 24 V DC.
Allowable power supply voltage
fluctuation range
Model
CJ1W-PD025
19.2 to 28.8 VDC (±20%)
CJ1W-PD022
21.6 to 26.4 VDC (±10%)
LG
Ground to a resistance of 100 Ω or less to increase noise resistance and avoid electric shock.
GR
Ground to a resistance of 100 Ω or less to avoid electric shock.
RUN Output (CJ1W-PA205R Only)
The internal contact turns ON when the CPU Unit is operating (RUN or MONITOR mode). The Power Supply Unit must be in the CPU Rack to use
this output.
Alarm Output (CJ1W-PA205C Only)
The alarm output is used to notify when Power Supply Unit replacement is required. The output is normally ON. The output turns OFF when the
time until replacement is 6 months or less.
Wiring
Wire
For AC/DC power supply
Recommended wire size
AWG14 to 20
(0.517 to 2.08mm2)
For grounding wire
Recommended wire size
2 mm2 min.
For alarm output
Recommended wire size
Use
AWG 22 to 18
(0.32 to 0.82 mm2)
Connecting to PLC terminal block models
AWG 28 to 24
(0.08 to 0.2 mm2)
Connecting to PLC connector models
Pushing strength
(clamping operation)
Pulling strength
(holding force)
Length of stripped
section
30 N min.
30 N max.
7 to 10 mm
10 N min.
6
CJ1W-PA/PD
Crimp Terminals
The terminals on the Power Supply Unit are M4, self-raising terminals with screws. Use crimp terminals for wiring.
Crimp terminal for the AC power supply
7mm max.
Crimp terminal for the DC power supply
7mm max.
7mm max.
Crimp terminal for the grounding wire
7mm max.
7mm max.
The crimp terminal is not required for the alarm output.
Checking Current Consumption and Power Consumption
After selecting a Power Supply Unit based on considerations such as the power supply voltage, calculate the current and power requirements for
each Rack.
Condition 1: Current Requirements
There are two voltage groups for internal power consumption: 5 V and 24 V.
Current consumption at 5 V (internal logic power supply)
Current consumption at 24 V (relay driving power supply)
Condition 2: Power Requirements
For each Rack, the upper limits are determined for the current and power that can be provided to the mounted Units. Design the system so that
the total current consumption for all the mounted Units does not exceed the maximum total power or the maximum current supplied for the voltage
groups shown in the following tables.
The maximum current and total power supplied for CPU Racks and Expansion Racks according to the Power Supply Unit model are shown below.
Note: 1. For CPU Racks, include the CPU Unit current and power consumption in the calculations. When expanding, also include the current and
power consumption of the I/O Control Unit in the calculations.
2. For Expansion Racks, include the I/O Interface Unit current and power consumption in the calculations.
Max. current supplied
Power Supply Units
5V
24 V (relay driving current)
Max. total power supplied
CJ1W-PA205R
5.0 A
0.8 A
25 W
CJ1W-PA205C
5.0 A
0.8 A
25 W
CJ1W-PA202
2.8 A
0.4 A
14 W
CJ1W-PD025
5.0 A
0.8 A
25 W
CJ1W-PD022
2.0 A
0.4 A
19.6 W
Conditions 1 and 2 below must be satisfied.
Condition 1: Maximum Current
(1) Total Unit current consumption at 5 V ≤ (A) value
(2) Total Unit current consumption at 24 V ≤ (B) value
Condition 2: Maximum Power
(1) × 5 V + (2) × 24 V ≤ (C) value
7
CJ1W-PA/PD
Example: Calculating Total Current and Power Consumption
Example: When the Following Units are Mounted to a CJ-series CPU Rack Using a CJ1W-PA202 Power Supply Unit
Unit type
Model
CPU Unit
Voltage group
Quantity
CJ1M-CPU13
1
5V
24 V
0.580 A
−
I/O Control Unit
CJ1W-IC101
1
0.020 A
−
Basic I/O Units
(Input Units)
CJ1W-ID211
2
0.080 A
−
CJ1W-ID231
2
0.090 A
−
Basic I/O Units
(Output Units)
CJ1W-OC201
2
0.090 A
0.048 A
Special I/O Unit
CJ1W-DA041
1
0.120 A
−
CPU Bus Unit
CJ1W-CLK23
1
0.350 A
−
0.580 + 0.020 + 0.080 × 2 + 0.090 ×
2 + 0.090 × 2 + 0.120 + 0.350
0.048 A × 2
Current consumption
Power consumption
Total
Result
1.59 A (≤ 2.8 A)
0.096 A (≤ 0.4 A)
Total
1.59 × 5 V = 7.95 W
0.096 A × 24 V = 2.304 W
Result
7.95 + 2.304 = 10.254 W (≤ 14 W)
Note: For details on Unit current consumption, refer to Ordering Information.
Using the CX-Programer to Display Current Consumption and Width
CPU Rack and Expansion Rack current consumption and width can be displayed by selecting Current Consumption and Width from the Options
Menu in the CS/CJ/CP Table Window. (The width can be displayed for the CJ/CP Series only.) If the capacity of the Power Supply Unit is exceeded,
it will be displayed in red characters. For details, refer to the CX-Programmer Operation Manual (Cat. No. W446).
Example:
Power Supply
Unit model
Current
Total current
consumption
Width
at 5 V
consumption
Current
Long-distance
consumption
expansion
at 26 V/24 V
8
CJ1W-PA/PD
Dimension
(Unit: mm)
CJ1W-PA205R
PA205R
POWER
L1
AC100-240V
INPUT
L2/N
90
RUN
OUTPUT
AC240V
DC24V
65
81.6
80
CJ1W-PA205C
CJ1W-PA205C
POWER
AC100-240V
INPUT
Years
L1
TEST
L2/N
90
ALARM
OUTPUT
DC30V,50mA
NORMAL:ON
ALARM :OFF
L
+
NC
NC
65
81.6
80
CJ1W-PA202
PA202
POWER
L1
AC100
-240V
INPUT
L2/N
90
NC
NC
65
81.6
45
9
CJ1W-PA/PD
CJ1W-PD025
PD025
POWER
DC24V+
INPUT
90
NC
NC
65
81.6
60
CJ1W-PD022
PD022
POWER
90
65
81.6
27
Related Manuals
Cat. No.
W393
Name
SYSMAC CJ Series
CJ1H-CPU@@H-R, CJ1G/H-CPU@@H, CJ1G-CPU@@P,
CJ1G-CPU@@, CJ1M-CPU@@
Programmable Controllers Operation Manual
Contents
Provides an outlines of and describes the design, installation,
maintenance, and other basic operations for the CJ-series PLCs.
10
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
 Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
 Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
 Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.