omron.com

New Product
Key-type Selector Switches
A22NK
Keyed 22-mm Selector Switches
Universal Design.
Emphasis on Color Coding, Workability,
and Safety.
Easy to Use
• You can connect up to three Contact Blocks in one stage for
multistage expansion.
• The terminals can be retightened when Contact Blocks are
stacked.
• Contact Blocks can be attached in any direction for easy
assembly.
• Screw terminal structure is compatible with round crimp
terminals.
Safety
• Easy-to-operate lock lever for secure locking.
• Easy-mounting Contact Blocks provide finger protection.
• Different colors of Contract Blocks (NO: blue, NC: orange)
help prevent wiring errors.
Product Lineup
• Meet global safety standards.
• Available with metal or plastic bezels.
• All models are keyed alike.
• Standard-feature degree of protection: IP66 and NEMA 13.
Refer to Safety Precautions for All Pushbutton Switches/Indicators and Safety Precautions in the A22NN/
A22NL datasheet
1
A22NK
Model Number Structure
Model Number Legend - - - - - -Shipped as a set that includes the Operation Unit, Mounting Collar, and Contact Block.
For information on combinations, refer to Ordering Information on pages 5 to 6.
Model Numbers for Sets
(1)
(2)
(3)
(4) (5)
(6)
(7)
(8)
A22N K - 2B M - 01 A A - G 100
(1) Type
(4) Key Number
(7) Contact Specification
Code
Type
Code
No.
Code
Description
K
Key-type Selector Switch
01
No.1
G
General purpose
(2) Number of Positions and
Bezel Material
Code
No. of
positions
Bezel material
2B
2
Plastic
2M
2
Brushed metal
2R
2
Metal
3B
3
Plastic
3M
3
Brushed metal
3R
3
Metal
(5) Key Release Position
Code
Release
position
A
All
positions
Two
positions
Three
positions
B
Left
C
Right
D
M
L
R
B
Center
Automatic
reset on
left
Automatic
reset on
right
Automatic
reset on
left and
right
Twopositions
manual
Left and
right
G
Threepositions
manual
---
❍: Release position
●: Locked position
Twopositions
automatic
(6) Degree of Protection
Threepositions left
automatic
Code
Protection
A
IP66, NEMA13
Threepositions
right
automatic
Threepositions left
or right
automatic
Two Positions
Contact
Blocks
Unit position
Two
positions
1
2
3
100
1
0
NO
---
---
Yes
---
002
0
1
---
---
NC
Yes
---
101
2
0
NO
---
NO
Yes
Yes
102
1
1
NO
---
NC
Yes
Yes
201
1
1
NC
---
NO
---
Yes
202
0
2
NC
---
NC
Yes
Yes
110
2
0
NO NO
---
---
Yes
111
3
0
NO NO NO
Yes
Yes
112
2
1
NO NO NC
Yes
Yes
210
1
1
NC NO
---
---
Yes
211
2
1
NC NO NO
---
Yes
212
1
2
NC NO NC
---
Yes
011
2
0
---
NO NO
---
Yes
012
1
1
---
NO NC
---
Yes
120
1
1
NO NC
---
Yes
121
2
1
NO NC NO
---
Yes
122
1
2
NO NC NC
Yes
Yes
220
0
2
NC
NC
---
---
Yes
221
1
2
NC
NC NO
---
Yes
---
222
0
3
NC
NC NC
Yes
Yes
021
1
1
---
NC NO
---
Yes
022
0
2
---
NC NC
---
Yes
Three Positions
0
90°
2
1
45°
45°
2
■ Specifications: Refer to page 10 and refer to the A22NN/A22NL. ■ Precautions for correct use: Refer to the A22NN/A22NL.
■ Dimensions: Refer to page 11.
2
Three
positions
Note: 1. NO (blue): Normally open, NC (orange):
Normally closed.
2. Refer to the following figure for Unit
positions.
Operation Angle
1
---
Reset method
Manual
Code
NO NC
(3) Reset Method
Code
(8) Contact Configuration
A22NK
Structure
Operation Angle
Contact Configuration Table
Two Positions
Two Positions
No. of
outputs
Code
Contact
configuration
1
100
SPST-NO
1
2
2
2
3
3
3
3
002
102
101
202
111
222
122
112
SPST-NC
SPST-NO/
SPST-NC
DPST-NO
DPST-NC
3PST-NO
3PST-NC
SPST-NO/
DPST-NC
DPST-NO/
SPST-NC
Position
Unit
position
Contacts
(1)
NO
(2)
---
---
(3)
---
---
---
(1)
---
---
-----
1
Three Positions
0
90°
2
1
2
1
45°
45°
2
ON
(2)
---
---
(3)
NC
ON
(1)
NO
(2)
---
---
(3)
NC
ON
(1)
NO
(2)
---
(3)
NO
---
ON
--ON
---
--ON
(1)
NC
(2)
---
---
(3)
NC
ON
(1)
NO
ON
(2)
NO
ON
(3)
NO
(1)
NC
ON
(2)
NC
ON
(3)
NC
ON
(1)
NO
(2)
NC
ON
(3)
NC
ON
(1)
NO
(2)
NO
(3)
NC
Unit
position
Contacts
(1)
NO
ON
ON
---
ON
ON
ON
ON
ON
Three Positions
No. of
outputs
2
2
2
2
2
2
2
Code
110
011
101
220
022
202
120
Contact
configuration
DPST-NO
DPST-NO
DPST-NO
DPST-NC
DPST-NC
DPST-NC
SPST-NO/
SPST-NC
Position
1
0
2
(2)
NO
ON
(3)
---
---
---
---
(1)
---
---
---
---
(2)
NO
ON
(3)
NO
(1)
NO
ON
(2)
---
---
(3)
NO
(1)
NC
ON
(2)
NC
ON
(3)
---
---
---
---
(1)
---
---
---
---
(2)
NC
ON
ON
ON
---
--ON
ON
ON
ON
ON
(3)
NC
(1)
NC
ON
ON
(2)
---
---
---
---
(3)
NC
ON
ON
(1)
NO
ON
(2)
NC
(3)
---
ON
---
---
---
3
A22NK
No. of
outputs
2
2
2
2
2
3
3
3
3
3
3
3
3
4
Code
Contact
configuration
102
SPST-NO/
SPST-NC
210
201
012
021
111
222
122
212
221
211
121
112
SPST-NO/
SPST-NC
SPST-NO/
SPST-NC
SPST-NO/
SPST-NC
SPST-NO/
SPST-NC
3PST-NO
3PST-NC
SPST-NO/
DPST-NC
SPST-NO/
DPST-NC
SPST-NO/
DPST-NC
DPST-NO/
SPST-NC
DPST-NO/
SPST-NC
DPST-NO/
SPST-NC
Contacts
(1)
NO
ON
(2)
---
---
---
(3)
NC
ON
ON
1
(1)
NC
(2)
NO
ON
(3)
---
---
(1)
NC
(2)
---
(3)
NO
Operation Angle
Position
Unit
position
0
Three Positions
0
ON
---
2
--1
ON
ON
---
---
ON
ON
---
--ON
(1)
---
---
(2)
NO
ON
---
--ON
(3)
NC
ON
(1)
---
---
(2)
NC
(3)
NO
(1)
NO
ON
(2)
NO
ON
(3)
NO
(1)
NC
ON
(2)
NC
ON
ON
---
---
ON
ON
ON
ON
(3)
NC
ON
(1)
NO
ON
(2)
NC
(3)
NC
(1)
NC
(2)
NO
ON
(3)
NC
ON
(1)
NC
ON
(2)
NC
ON
ON
ON
ON
ON
ON
ON
(3)
NO
(1)
NC
(2)
NO
(3)
NO
(1)
NO
(2)
NC
(3)
NO
(1)
NO
ON
(2)
NO
ON
(3)
NC
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
45°
45°
2
A22NK
Ordering Information
Model Numbers for Sets - - - - Shipped as a set that includes the Operation Unit, Mounting Collar, and Contact Block.
Two-position, Key-type Selector Switches
Appearance
Bezel
material
Plastic bezels
No. of
outputs
(5)
Key release
positions
(8)(8)(8)
Contact
configuration
100
002
2
102
101
202
A22NK-2B(3)-01(5)A-G(8)(8)(8)
3
111
222
122
112
1
100
002
2
2M
Metal bezels
(3)
Reset method
1
2B
Brushed metal bezels
Model
A22NK-2M(3)-01(5)A-G(8)(8)(8)
M: Manual
L: Automatic reset on left
A: All positions
B: Left
C: Right
102
101
202
3
111
222
122
112
1
100
002
2
102
101
202
2R
A22NK-2R(3)-01(5)A-G(8)(8)(8)
3
111
222
122
112
5
A22NK
Three-position, Key-type Selector Switches
Appearance
Bezel
material
No. of
outputs
(3)
Reset method
Model
(5)
Key release
positions
110
011
101
220
022
202
120
102
210
201
012
021
Plastic bezels
2
3B
A22NK-3B(3)-01(5)A-G(8)(8)(8)
3
111
222
122
212
221
211
121
112
2
110
011
101
220
022
202
120
102
210
201
012
021
Brushed metal bezels
3M
A22NK-3M(3)-01(5)A-G(8)(8)(8)
A: All positions
M: Manual
B: Left
L: Automatic reset on left
C: Right
R: Automatic reset on right
D: Center
B: Automatic reset on left and right
G: Left and right
3
111
222
122
212
221
211
121
112
2
110
011
101
220
022
202
120
102
210
201
012
021
Metal bezels
3R
A22NK-3R(3)-01(5)A-G(8)(8)(8)
3
■ Subassemblies: Refer to pages 7 to 9.
(You can order Operation Units, Mounting Collars, and
Contact Blocks individually.)
6
(8)(8)(8)
Contact
configuration
111
222
122
212
221
211
121
112
■ Specifications: Refer to page 10 and refer to the A22NN/A22NL.
■ Dimensions: Refer to page 11.
■ Accessories and tools: Refer to the A22NN/A22NL.
A22NK
Ordering Information
Subassemblies
- - - - - You can order Operation Units, Mounting Collars, and Contact Blocks individually. Use them in combination for
models that are not available as assembled Switches. They can also be used as inventory for maintenance
parts.
Plastic Operation Units
Brushed Metal Operation Units
Metal Operation Units
Mounting Collar
Contact Blocks
Note: Use a Reinforcement Plate for greater strength.
Reinforcement Plate
■ Model numbers of sets: Refer to page 5.
■ Specifications: Refer to page 10 and refer to the A22NN/A22NL.
■ Dimensions: Refer to page 11.
■ Accessories and tools: Refer to the A22NN/A22NL.
7
A22NK
Ordering Information
Subassemblies - - - - - You can order Operation Units, Mounting Collars, and Contact Blocks individually. Use them in combination for
models that are not available as assembled Switches. They can also be used as inventory for maintenance parts.
Operation Units
Plastic
Brushed metal
Metal
Bezel material and shape
No. of
positions
2
3
Reset method
(1)
Key release
positions
Model
Model
Manual
A22NZ-2BM-01(1)A
A22NZ-2MM-01(1)A
A22NZ-2RM-01(1)A
Automatic reset
on left
A22NZ-2BL-01(1)A
A22NZ-2ML-01(1)A
A22NZ-2RL-01(1)A
Manual
A22NZ-3BM-01(1)A
A22NZ-3MM-01(1)A
A22NZ-3RM-01(1)A
Automatic reset
on left
A22NZ-3BL-01(1)A
A22NZ-3ML-01(1)A
A22NZ-3RL-01(1)A
Automatic reset
on right
A22NZ-3BR-01(1)A
A22NZ-3MR-01(1)A
A22NZ-3RR-01(1)A
Automatic reset
on left and right
A22NZ-3BB-01(1)A
A22NZ-3MB-01(1)A
A22NZ-3RB-01(1)A
■ Model numbers of sets: Refer to page 5.
8
Model
A: All positions
B: Left
C: Right
A: All positions
B: Left
C: Right
D: Center
G: Left and right
■ Specifications: Refer to page 10 and refer to the A22NN/A22NL.
■ Dimensions: Refer to page 11.
■ Accessories and tools: Refer to the A22NN/A22NL.
A22NK
Ordering Information
Subassemblies
- - You can order Operation Units, Mounting Collars, and Contact Blocks individually. Use them in combination for
models that are not available as assembled Switches. They can also be used as inventory for maintenance parts.
Mounting Collar
Appearance
Model
A22NZ-H-01
Contact Blocks
Appearance
Contact
Specification
Model
SPST-NO (blue)
A22NZ-S-G1A
SPST-NC (orange)
A22NZ-S-G1B
Reinforcement Plate
Appearance
Model
A22NZ-A-C01
Accessories
Appearance
Model
Key
A22NZ-K-01
9
A22NK
Specifications
Characteristics
Type
Key-type Selector Switches
Item
Allowable operating
frequency
Mechanical
30 operations/minute max.
Electrical
30 operations/minute max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
Dielectric strength
100 mΩ max. (initial value)
Between terminals
of same polarity
2,500 VAC at 50/60 Hz for 1 min
Between each termi2,500 VAC at 50/60 Hz for 1 min
nal and ground
Vibration resistance
Malfunction
10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms)
Shock resistance
Malfunction
1,000 m/s2 max. (malfunction within 1 ms)
Mechanical
500,000 operations min. (Switches with 3 positions: 300,000 operations min.)
Electrical
500,000 operations min. (Switches with 3 positions: 300,000 operations min.)
Durability
Ambient operating temperature*1
−25 to 70°C
Ambient operating humidity
35% to 85% RH
Ambient storage temperature*1
−40 to 80°C
Degree of protection*2
IP66, NEMA13
Electric shock protection class
Class II
PTI (tracking characteristic)
175
Degree of contamination (application environment)
3 (IEC 60947-5-1)
Weight
Approx. 65 g (for 1NC/1NO)
*1. With no icing or condensation.
*2. Degree of protection from the front of the panel.
Operating Characteristics (for SPST-NO/SPST-NC)
Type
Key-type Selector Switches
Item
Manual reset
Automatic reset
Total travel force (torque) (maximum TTF)
0.6 N·m
0.6 N·m
Total travel (TT)
2 positions: Approx. 90°, 3 positions: Approx. 45°
Resetting force (torque) (RF)
0.5 N·m max.
---
Examples of Linked Contact Blocks
Contact Blocks
Key-type Selector Switches
Linking example
2 positions
3 positions
Operation Unit
Operation Unit
Mounting Collar
Mounting Collar
Note: If you increase the number of Contact Blocks, evaluate the Switch under actual working conditions before permanent installation and use
the Switch within a number of switching operations that will not adversely affect the Switch’s performance.
10
A22NK
Dimensions
(Unit: mm)
Lighted and Non-lighted Key-type Selection Switches
Two-position Switches with Plastic Bezels
A22NK-2B@
R29.2
90°
Two positions
28.8 dia.
43.5
47
11
0.5
5
1.8
24.2
30
18.8
45.3
Three-position Switches with Plastic Bezels
A22NK-3B@
43.5
28.8 dia.
11
5
0.5
1.8
24.2
18.8
45.3
Two-position Switches with Brushed Metal Bezels Three-position Switches with Brushed Metal Bezels
A22NK-2M@
A22NK-3M@
28.8 dia.
28.8 dia.
43.5
43.5
11
11
24.2
18.8
24.2
45.3
18.8
45.3
Two-position Switches with Metal Bezels
Three-position Switches with Metal Bezels
A22NK-2R@
A22NK-3R@
28.8 dia.
43.5
28.8 dia.
43.5
11
24.2
Depth with Linked Units
18.8
11
45.3
24.2
Terminal Wiring Diagrams
18.8
45.3
Terminal Connection Diagrams
Bottom View
2NO/1NC
Contact configuration
code:112
2NO/1NC
Contact configuration
code:112
20
10
45.3
Bottom View
Contact
Blocks
1
3
3
2
4
4
66.8
Six, M3.5
Phillips/slotted
screws
11
A22NK
Safety Precautions
Refer to Safety Precautions for All Pushbutton Switches/Indicators for common precautions.
Read the Safety Precautions in the A22NN/A22NL datasheet.
Precautions for Correct Use
Insert the key all of the way to the back of the cylinder before you turn it.
12
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2015 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
CSM_1_1_0415
Cat. No. A241-E1-01
0415 (0415)