Datasheet

G3VM-401A/D
MOS FET Relays
Expanded Range of Analog-switching MOS FET Relays
with 400-V Load Voltage.
• Continuous load current of 120 mA.
• Dielectric strength of 2,500 Vrms between I/O.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal
Connections
• Test & Measurement equipment
• Security equipment
4
3
• Amusement equipment
Mold pin mark *
OMRON logo
Model name
Pin 1 mark
1
932
LOT.NO.
2
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
■ List of Models
Package type Contact form
Load voltage
(peak value) *
Terminals
PCB Terminals
DIP4
1a
(SPST-NO)
Model
G3VM-401A
400 V
Surface-mounting Terminals
G3VM-401D
G3VM-401D (TR)
Minimum package quantity
Number per tube Number per tape and reel
100
-
-
1,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Connection temperature
Dielectric strength between I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
IFP
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
TJ
VI-O
Ta
Tstg
-
Rating
50
1
−0.5
5
125
400
120
−1.2
125
2500
−40 to +85
−55 to +125
260
Unit
mA
A
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
°C
°C
°C
Measurement conditions
100 µs pulses, 100 pps
Ta ≥ 25°C
Ta ≥ 25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25°C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.0
1.15
1.3
Reverse current
IR
10
Capacity between terminals
CT
30
Trigger LED forward current
IFT
1
3
Maximum resistance with output ON
RON
18
35
Current leakage when the relay is open
ILEAK
1.0
Capacity between terminals COFF
40
Capacity between I/O terminals
CI-O
0.8
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
1.0
Turn-OFF time
tOFF
1.0
1
Unit
V
µA
pF
mA
Ω
µA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
Note: 2. Turn-ON and Turn-OFF Times
VR = 5 V
IF 1
4 RL
VDD
V = 0, f = 1 MHz
VOUT
2
3
IO = 120 mA
IF = 5 mA, IO = 120 mA
VOFF = 400 V
V = 0, f = 1 MHz
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60%
90%
VOUT
10%
IF = 5 mA, RL = 200 Ω,
t
ON
t OFF
VDD = 20 V(See note 2.)
G3VM-401A/D
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Load voltage (AC peak/DC)
VDD
-
-
320
Unit
V
Operating LED forward current
IF
5
7.5
25
mA
Continuous load current (AC peak/DC)
IO
-
-
100
mA
Ambient operating temperature
Ta
−20
-
65
°C
■ Engineering Data
Continuous load current vs. Ambient
temperature
IF - Ta
LED forward current vs. LED forward
voltage
IO - Ta
80
60
40
IF - VF
280
LED forward current IF (mA)
100
Continuous load current IO (mA)
LED forward current IF (mA)
LED forward current vs. Ambient
temperature
240
200
160
120
20
40
60
80
100
0
-20
120
0
20
40
80
100
50
IF = 5mA
t < 1s
40
30
20
10
2
0
-20
3
0
20
tON, tOFF - IF
3000
Ta = 25°C
IF = 5mA
VDD = 20V
1000
RL = 200Ω
500
300
100
60
80
tOFF
tON, tOFF - Ta
1000
VDD = 20V
RL = 200Ω
800
IF = 5mA
tON
600
400
t < 1s
4
3
2
1
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
Current leakage vs. Ambient
temperature
ILEAK - Ta
300
VOFF = 400V
100
30
10
3
1
200
tOFF
0.3
50
30
0.5
1.8
IO = 120mA
0
-40
100
Turn ON, Turn OFF time vs. Ambient
temperature
Turn ON, Turn OFF time tON, tOFF (µs)
Turn ON, Turn OFF time tON, tOFF (µs)
Turn ON, Turn OFF time vs. LED
forward current
tON
40
1.6
5
Ambient temperature Ta (°C)
Current leakage ILEAK (nA)
1
On-state voltage VON (V)
1.4
IFT - Ta
IO = 120mA
-100
0
1.2
LED forward voltage VF (V)
Trigger LED forward current IFT (mA)
0
-1
1
RON - Ta
100
-2
0.8
Trigger LED forward current vs.
Ambient temperature
60
Ta = 25°C
IF = 5mA
-200
-3
0.1
0.6
120
On-state resistance vs. Ambient
temperature
On-state resistance RON (Ω)
Continuous load current IO (mA)
60
Ambient temperature Ta (°C)
IO - VON
200
3
0.3
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
10
1
40
0
30
80
20
0
-20
100
1
3
5
10
30
50
100
0
-40
0.1
-20
LED forward current IF (mA)
0
20
40
60
80
100
Ambient temperature Ta (°C)
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
DIP4 type
■ Appearance
DIP (Dual Inline Package)
DIP4
Mold pin mark *
OMRON logo
Model name
Pin 1 mark
932
LOT.NO.
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.
■ Dimensions
(Unit:mm)
PCB Terminals
Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW)
Weight: 0.25 g
Weight: 0.25 g
Four, 0.8-dia. holes
2.54
(0.61)
2.54
4.58±0.25
4.58±0.25
6.4±0.25
Actual Mounting Pad Dimensions
7.62±0.25
7.62±0.25
0.8±0.25
3.65+0.15
–0.25
0.25 +0.1
–0.05
2.5 min.
1.2±0.15
0.5±0.1
2.54±0.25
(0.61)
(1.52)
(1.52)
6.4±0.25
+0.15
3.65–0.25
(Recommended Value, TOP VIEW)
2.54
4.0+0.25
–0.2
1.0 min.
7.85 to 8.80
1.2±0.15
2.54±0.25
Note: The actual product is marked differently from the
image shown here.
1.0 min.
8.3 to 8.8
10.0 max.
1.3
1.5
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K149-E1-01
0412(0412)(O)