3f31 ver1.3.fm

FERROXCUBE
DATA SHEET
3F31
Material specification
2013 Jun 05
Ferroxcube
Material specification
3F31
3F31 SPECIFICATIONS
A medium frequency power material for use in power
and general purpose transformers at frequencies of 0.2
- 0.5 MHz.
SYMBOL
CONDITIONS
VALUE
µi
25 °C; ≤10 kHz; 0.25 mT
1800 ±
20%
µa
100 °C; 25 kHz; 200 mT
≈ 3800
B
25 °C; 10 kHz; 1200 A/m
≈ 520
µ's , µ''s
UNIT
100 °C; 400 kHz; 50 mT
µ's
µ''s
mT
10 2
≈ 80
kW/m3
100 °C; 500 kHz; 50 mT
≈ 175
DC; 25 °C
≈8
Ωm
TC
≥ 230
°C
density
≈ 4750
kg/m3
ρ
3F31
10 3
100 °C; 10 kHz; 1200 A/m ≈ 420
PV
ABW481
10 4
handbook, halfpage
10
10 1
1
Fig.1
10
f (MHz)
Complex permeability as
a function of frequency.
ABW455
5000
handbook, halfpage
3F31
µi
25oC
100oC
500
4000
ABW015
handbook, halfpage
3F31
B
(mT)
400
3000
300
2000
200
1000
100
0
50
0
50
50
Fig.2
2013 Jun 05
150
T ( o C)
250
Initial permeability as a
function of temperature.
0
50
100
500
1000
H (A/m)
Fig.3 Typical B-H loops.
2
10 2
Ferroxcube
Material specification
3F31
ABW443
8000
25 oC
o
100 C
handbook, halfpage
µa
3F31
ABW477
10 4
handbook, halfpage
3F31
6000
µ rev
10 3
4000
2000
10 2
0
0
100
200
300
400
B (mT)
10
Fig.4
Amplitude permeability as
function of peak flux density.
10 2
10
1
Fig.5
H (A/m) 10
Reversible permeability as a
function of magnetic field strength.
ABW456
400
handbook, halfpage
10 4
handbook, halfpage
T = 100
o
3F31
C
Pv
(kW/m 3)
3F31
Pv
(kW/m 3 )
ABW048
3
f
B
(kHz) (mT)
700
kHz
40
0k
Hz
200
kHz
300
10 3
200
10 2
500
50
200
100
400
50
100
10
1
10
10 2
B (mT)
10
0
3
0
Fig.7
Fig.6
Specific power loss as a function of peak
flux density with frequency as a parameter.
2013 Jun 05
3
40
80
T (o C)
120
Specific power loss for several
frequency/flux density combinations
as a function of temperature.
Ferroxcube
Material specification
3F31
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2013 Jun 05
4