LDA30F

Ordering information
Rugged PCB type
LDA30F
LDA
1
30
2
F
3
-5
4
-O
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
R
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LDA30F-3
18
3V 6.0A
LDA30F-5
30
5V 6.0A
LDA30F-12
30
12V 2.5A
LDA30F-15
30
15V 2.0A
LDA30F-24
31.2
24V 1.3A
SPECIFICATIONS
MODEL
VOLTAGE[V]
LDA
CURRENT[A]
INPUT
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C
RIPPLE[mVp-p]
-10 - 0C
0 to +50C
RIPPLE NOISE[mVp-p]
-10 - 0C
TEMPERATURE REGULATION[mV]
*1
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
INRUSH CURRENT[A]
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*
*
*
ACIN 100V
ACIN 200V
LDA30F-3
LDA30F-5
LDA30F-12
LDA30F-15
LDA30F-24
AC85 - 264 1f or DC110 - 370
0.8typ (Io=100%)
0.4typ (Io=100%)
47 - 440 or DC
70typ
75typ
77typ
78typ
79typ
15typ (Io=100%) (At cold start)
30typ (Io=100%) (At cold start)
0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
3
5
12
15
24
6
6
2.5
2
1.3
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
60max
60max
150max
180max
290max
20max
20max
48max
60max
96max
200max (ACIN 100V, Io=100%)
10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%)
2.85 - 3.6
Fixed ("Y"which can be adjusted the output is available as option :5 - 24V t10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
xx
Works over 105% of rating and recovers automatically
4.00 - 5.25V
Works at 115 - 140% of rating
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
-10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL1950, EN60950, VDE0160, CSA C22.2 No.234 Complies with DEN-AN and IEC60950
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
55X26X133mm (WXHXD) /200g max (without chassis and cover)
Convection
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
D-30