Technical Specification Industrial Grade AC/DC Power

Technical
Specification
400 W Triple Vout Series
Industrial Grade AC/DC Power Supply With PFC
85-264 Vrms
12/24/36/48 V
400 W
Input Voltage
Semi-Regulated Output
500 W
Up to Up to 91 %
Output Continuous Output Transient Full Load Efficiency
Includes 5 V (10 W) and 12 V (50 W) “Always On” Standby Power Outputs
400 W Open Frame
Configurations
•400WEncasedorOpenFrame
•800WEncasedFlatorStacked
•1200WEncasedFlatorStacked
400 W Encased
1200 W Encased Stacked
800 W Encased Flat
Product Features
• High efficiency (91% for 48 VOUT Model at 400 W)
• Universal input voltage range
• Semi-regulated output for bus stability
• Parallel operation supported
• Integral fan cooling with speed control
• Active PFC; EN61000-3-2 compliant
• Low leakage; EN60601-1 compliant
• Low noise; EN55011 / EN55022 Class B compliant
Product # AQ0400IUxT
Phone 1-888-567-9596
• Over–current, over–voltage, & over–temp protection
• DC Power Good / AC Power Good signals
• Remote enable input
• Fan status output / Fan enable input
• Small size: 3" x 5" x 1.45"(open frame)
• RoHS 6/6 compliant
• 5 V (10 W) and 12 V (50 W) standby outputs
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 1
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
Technical Specification
ACuQor 400W Triple Vout Series Electrical Characteristics
All specifications typical with TA = 25 °C, unless otherwise specified. Specifications subject to change without notice.
MAIN OUTPUT SPECIFICATIONS
Output power (continuous) 85-132/170-264 Vrms
(5 s transient)
85-132/170-264 Vrms
132-170 Vrms
GENERAL SPECIFICATIONS
Input
400 W (Note 1) Fundamental ripple freq.
Output
500 W (Note 1)
Fan speed varies with temp.
See Figures 10 Audible noise
500 kHz
250 kHz
39 dBA @ 1 m max.
343 g (12.1 oz) \ 446 g (15.7 oz)
V Weight (EA \ EC)
(SC \ RC)
846 g (29.8 oz) \ 879 g (31 oz)
V
(UC \ TC)
1224 g (43.2 oz) \ 1298 g (45.8 oz)
V
V MTBF
MIL-217
343.6 kHours
Demonstrated
TBD kHours
Efficiency
12 Vout, 115 Vrms, 400 W
88% typ.
(see figs. 1, 3, 5, 7)
48 Vout, 115 Vrms, 400 W
90% typ. ISOLATION SPECIFICATIONS
(see Note 1)
12 Vout, 230 Vrms, 400 W
89% typ. Isolation voltage
Input to output
3000 Vrms
48 Vout, 230 Vrms, 400 W
91% typ.
Input to ground
1500 Vrms
Hold-up time (to -20%)
12 Vout
16 ms @ 400 W
Output to ground
500 Vrms
(see Note 1)
24 / 36 / 48 Vout
20 ms @ 400 W
Maximum load capacitance 12 Vout
16,000 µF Insulation resistance
Output to ground
10 MΩ min.
24 Vout
8,000 µF
Leakage currents
See Note 2
36 Vout
4,000 µF
48 Vout
2,000 µF ENVIRONMENTAL CHARACTERISTICS
Operating ambient (see Figure 2)
-40 ºC to +70 ºC
Output ripple voltage
Switching frequency (20 MHz BW)
0.5% p-p Thermal performance
Non-operating ambient
-40 ºC to +85 ºC
Twice line frequency (at 300W)
5.0% p-p
Relative humidity
Non-condensing
5-95% RH
Turn-on delay
2 s max. Altitude
Operating
10,000 ft max.
Non-operating
30,000 ft max.
Transient response
Iout steps from 50-75%
3% typ / 6% max. dev.
5-500 Hz
0.03 g2/Hz
At 0.2 A/µs
100 ms recovery Random vibration
Overvoltage protection
Cyclic restart
110-120% Shock
Half-sine, 10 ms, 3 axes
20 g peak
Nominal DC output
voltage (at 250W)
(Semi-regulated)
12
24
36
48
Vout
Vout
Vout
Vout
(model
(model
(model
(model
1T)
2T)
3T)
4T)
Short circuit protection
Cyclic operation
Total regulation
Over line, load and temperature
12V_STANDBY cross-reg.
ΔVout caused by 50 W step
5V_STANDBY cross-reg.
ΔVout caused by 10 W step
Thermal protection
Automatic recovery
REMOTE_ENABLE
Input Low Voltage
Input High Voltage
12V_STANDBY OUTPUT SPECIFICATIONS
Output power
85-264 Vrms
12.4
25
37.5
50
115% rated Iout EMC CHARACTERISTICS
±6.0% Conducted emissions
0.5%
Line frequency harmonics
0.1%
Voltage fluctuations
+125 ºC (PCB Temp)
ESD air
0.45 V (max)
4.15 V (min) ESD contact
Radiated immunity
50 W Fast transients
EN55011 and EN55022, FCC
part15
EN61000-3-2
Level B
Class A
EN61000-3-3
Clause 5b
EN61000-4-2
Level 3
EN61000-4-2
Level 3
EN61000-4-3
Level 3
EN61000-4-4
Level 3
Nominal DC output voltage Semi-regulated
12.4 V Line surge immunity
EN61000-4-5
Level 3
Total regulation
Over line, load and temperature
±6.0% Conducted immunity
EN61000-4-6
Level 3
Main output cross-reg.
Δ12V_STANDBY caused by Δ350W
on main output
Switching frequency (20 MHz BW)
Twice line frequency
400 mV Power freq. mag. field
EN61000-4-8
Output ripple
Output current
Continuous
Short circuit protection
Cyclic operation
Maximum load capacitance
5V_STANDBY OUTPUT SPECIFICATIONS
Output power
85-264 Vrms
Nominal DC output voltage Fully regulated
Total regulation
Over line, load and temperature
Output current
Continuous
Short circuit protection
Cyclic operation
Maximum load capacitance
3 A/m
EN61000-4-11
Perf Criteria A, A, B
<5% UT 10 ms,
70% UT 500 ms,
40% UT 100 ms
4.2 A NOTES:
5.0 A 1. Main output power rating always includes 5 V and 12 V standby outputs.
2,000 uF 2. Leakage currents see page 5.
10 W
5.0 V
±5.0%
2.0 A
2.5 A
1,000 uF
INPUT SPECIFICATIONS
AC input voltage
Universal range
Input frequency
85-264 Vrms
47-63 Hz
Input current
(see Note 1)
Power factor
115 Vrms @ 400 W
230 Vrms @ 400 W
Input surge current
264 Vrms (cold start)
Internal input fuses
Both AC lines
Product # AQ0400IUxT
10 mV
0.45 Vrms
Voltage dip immunity
Phone 1-888-567-9596
4 Arms
2 Arms
>0.98
40 A max.
6.3 A
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 2
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
Technical Specification
EFFICIENCY, DERATING, AND VOUT DROOP CURVES
100
14.0
95
13.5
13.0
Output Voltage (V)
Efficiency (%)
90
85
80
75
12.0
11.5
11.0
115 Vrms
70
65
12.5
10.5
230 Vrms
0
100
200
300
400
10.0
500
0
4
8
12
Figure 1: 12 VOUT efficiency curves.
28
95
27
Output Voltage (V)
Efficiency (%)
85
80
75
28
32
36
12
14
16
18
25
24
23
22
115 Vrms
70
21
230 Vrms
0
100
200
300
400
20
500
0
2
4
6
Figure 3: 24 VOUT efficiency curves.
8
10
Output Load (A)
Output Power (W)
Figure 4: 24 VOUT droop characteristic.
42
100
95
40
Output Voltage (V)
90
Efficiency (%)
24
26
90
85
80
75
115 Vrms
70
65
20
Figure 2: 12 VOUT droop characteristic.
100
65
16
Output Load (A)
Output Power (W)
38
36
34
32
230 Vrms
0
100
200
300
400
30
500
Figure 5: 36 VOUT efficiency curves.
Product # AQ0400IUxT
Phone 1-888-567-9596
0
2
4
6
8
10
12
Output Load (A)
Output Power (W)
Figure 6: 36 VOUT droop characteristic.
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 3
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
Technical Specification
EFFICIENCY, DERATING, AND VOUT DROOP CURVES
100
54
95
52
Output Voltage (V)
Efficiency (%)
90
85
80
75
115 Vrms
70
65
50
48
46
44
230 Vrms
0
100
200
300
400
42
500
0
1
2
3
4
5
6
7
8
9
Output Load (A)
Output Power (W)
Figure 7: 48 VOUT efficiency curves.
Figure 8: 48 VOUT droop characteristic.
600
500
500
400
Power (W)
Power (W)
400
300
200
300
200
24 / 36 / 48 V with Fan Enabled
12 V with Fan Enabled
100
Transient
100
24 / 36 / 48 V with Fan Disabled
Continuous
12 V with Fan Disabled
0
0
10
20
30
40
50
60
70
0
80
Product # AQ0400IUxT
Phone 1-888-567-9596
132
170
264
Input AC Voltage (VRMS)
Ambient Temperature (ºC)
Figure 9: Continuous power derating curve in natural convection
85
Figure 10: Rated output power vs Input AC Voltage
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 4
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
Technical Specification
Leakage Currents
AC Leakage Current
from Input to Earth
ACuQor Typical at
110% nominal input
voltage 60 Hz
AC Line Connection
Normal Open Neutral
Condition
Fault
240 V L-N, 1 phase
400 µA
800 µA
208 V L-L, 120 V L-N, 1 of 3 phases
200 µA
400 µA
240 V L-N-L, 120 V L-N, split phase
200 µA
400 µA
Standard Testing Certifications
SAFETY AGENCY CERTIFICATIONS
CAN/CSA-C22.2 No. 60950-1:2007
UL 60950-1:2007
EN 60950-1/A1:2010
CE Marked
Product # AQ0400IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 5
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
CONNECTOR DETAILS
OUTPUT CONNECTOR PINOUT (top side)
Pin 1 FAN_GOOD
Open collector with internal 5V pullup. See Figure A.
Pulsed low on fan failure, 100ms, 50% duty.
Short to VOUT(-) to disable fan.
Pin 2 AC_POWER_GOOD
Open collector with internal 5V pullup. See Figure B.
Pulled low on AC power dropout.
Pin 3 DC_POWER_GOOD
Open collector with internal 5V pullup. See Figure B.
Pulled low during startup ramp and within 5 ºC of
temperature shutdown threshold.
Pin 4 5V_STANDBY
5 V @ 10 W available whenever AC power is applied.
Figure A: Fan status output / Fan enable input interface circuitry.
Pin 5
VOUT(+)
Positive Output Voltage.
Pin 6
VOUT(+)
Positive Output Voltage.
Pin 7
VOUT(+)
Positive Output Voltage.
Pin 8
VOUT(+)
Positive Output Voltage.
Pin 9
Reserved
Reserved for future use.
Pin 10 Reserved
Reserved for future use.
Pin 11 REMOTE_ENABLE
Pin 12 12V_STANDBY
Logic input. See Figure C.
Pull high to enable main output.
12 V @ 50 W available whenever AC power is applied.
Pin 13 VOUT(–)
Negative Output Voltage.
Pin 14 VOUT(–)
Negative Output Voltage.
Pin 15 VOUT(–)
Negative Output Voltage.
Pin 16 VOUT(–)
Negative Output Voltage.
5V_STANDBY
N4148
5k
10 Ohms
AC_POWER_GOOD or
DC_POWER_GOOD
N3904
From AC/DC
Monitor
Circuitry
0.1 µF
VOUT(-)
Figure B: Power good interface circuitry.
12 V OUTPUT CONNECTOR PINOUT (bottom side)
Pin 1 VOUT(+)
Positive Output Voltage.
Pin 2
VOUT(+)
Positive Output Voltage.
Pin 3
VOUT(+)
Positive Output Voltage.
Pin 4
VOUT(+)
Positive Output Voltage.
Pin 5
VOUT(–)
Negative Output Voltage.
Pin 6
VOUT(–)
Negative Output Voltage.
Pin 7
VOUT(–)
Negative Output Voltage.
Pin 8
VOUT(–)
Negative Output Voltage
5V_STANDBY
5V_STANDBY
REMOTE_ENABLE
5k
10 Ohms
0.1 µF
To Enable
Circuitry
10k
VOUT(-)
Figure C: Remote enable interface circuitry.
MATING CONNECTORS
Connector
Type
Contact
INDIVIDUAL INPUT CONNECTOR PINOUT
Pin 1
Ground
OUTPUT (16 pins)
Molex 430251600
Molex 430300008*
12V_OUTPUT (8 pins)
Molex 436450800
Molex 430300008*
Pin 3
AC Neutral
INPUT
JST VHR-5N
JST SVH-41T-P1.1
Pin 5
AC Line
Product # AQ0400IUxT
* Each contact rated for a maximum of 5.5 A.
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 6
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
(1 Module Open Frame Version — E Package Type)
INPUT
CONNECTOR
3.00 [76.2]
.70
[17.8]
1.50
[38.1]
6 - 32 STANDOFF
1/4" HEX BODY
3/16" INTERNAL THREAD
(4 PIECES)
INPUT
CONNECTOR
.123 ±.019
[3.12 ±0.48]
BOTTOMSIDE
CLEARANCE
INPUT
CONNECTOR
Front
1.444 ±.053
[36.67 ±1.34]
.68
[17.4]
OUTPUT
1.06
[26.8]
5.00
[127]
4.60
[116.8]
Back
2.90
[73.7]
INPUT
Manufacturing Label
PN#
S/N
DATE CODE
1.03
[26.1]
3.03 [77]
.13
[3.3]
Top
.20
[5.1]
OUTPUT
CONNECTOR
.13
[3.2]
OUTPUT
CONNECTOR
2.60 [66]
Bottom
Right
(1 Module Encased Version — E Package Type)
Top
Right
Ø .19 PLASTIC RIVET OD.
[4.75]
Bottom
Front
6 - 32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTUDE 3/8” INTO THE CHASSIS
(4 PIECES)
1.63
[41.3]
3.59 [91.3]
.70
[17.8]
1.63
[41.3]
16 15 14 13 12 11 10 9
8 7 6 5 4 3 2 1
OUTPUT
1.31
[33.1]
4.13
[104.8]
5.25
[133.4]
.11
[2.9]
4.91
[124.7]
Back
3.03
[76.8]
Manufacturing Label
PN#
S/N
DATE CODE
1.05
[26.6]
.75
[19.1]
1.75 [44.5]
3.50 [88.9]
1.48
[37.5]
.17
[4.3]
.23 [5.9]
3.04 [77.1]
3.04 [77.1]
.38 [9.5]
NOTES (applies to all mechanicals)
1) Recommended screw tightening torque of 6 in.lbs
2) Undimensioned components are shown for visual reference only
3) All dimensions in inches [mm]
Tolerances:
x.xx in ± 0.02
x.xxx in ± 0.010
Product # AQ0400IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 7
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
(2 Modules Flat Version - R Package Type)
Front
3.63 [92.1]
.38 [9.5]
1.05 [26.7]
5
3
5
1
3
1
INPUT
Ø.19 [4.75] PLASTIC RIVET OD.
6.75 [171.5]
5.00 [127]
TOP
1.48
[37.5]
1.75 [44.5]
Right
5.25
[133.4]
4.88 [123.8]
3.03
[76.8]
6.84 [173.8]
.75 [19.1]
1.63 [41.3]
16 15 14 13 12 11 10 9
8 7 6 5 4 3 2 1
16 15 14 13 12 11 10 9
8 7 6 5 4 3 2 1
OUTPUT
Back
Bottom
OUTPUT
1.31 [33.1]
4.56 [115.7]
.71 [18]
6.29 [159.6]
3.14 [79.8]
.23 [5.9]
.17 [4.3]
6 - 32 Self - Clinching Insert
Mounting Screw shall not Protude
3/8” into the chassis (6 pieces)
4.91 [124.7]
Product # AQ0400IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 8
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
(2 Modules Stacked Version - S Package Type)
2.65
[67.2]
1.05
[26.7]
INPUT
INPUT
1
1
3
3
5
5
.38
[9.5]
3.25
[82.6]
6-32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTRUDE 3/8” INTO THE CHASSIS
(4 PIECES)
4.91
[124.7]
4.85
[123.2]
5.25
[133.4]
3.03
[76.8]
3.04
[77.1]
.17
[4.3]
.23
[5.9]
.20
[5.1]
1.75
[44.5]
1.59
[40.5]
.61
[15.4]
3.50
[88.9]
6-32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTRUDE .200” INTO THE CHASSIS
(4 PIECES)
8
7
16 15
7
OUTPUT
8
16 15
OUTPUT
4
3
11
2
10
1
9
1
9
12
2
10
5
3
11
13
4
12
6
5
13
14
6
14
1.31 [33.1]
.71
[18]
Product # AQ0400IUxT
Phone 1-888-567-9596
2.30
[58.5]
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 9
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
(3 Modules Flat Version - T Package Type)
6.88 [174.6]
3.63 [92.1]
.38 [9.5]
1.05
[26.7]
5
3
5
1
3
1
5
3
1
Ø .19
[4.8]
INPUT
PLASTIC RIVET OD.
1.48
[37.5]
5.25
[133.4]
4.88
[123.8]
3.03
[76.8]
1.75 [44.5]
.75
[19.1]
5.00 [127]
8.25 [12.096]
10.00 [254]
10.09 [256.4]
1.63
[41.3]
16 15 14 13 12 11 10 9
8 7 6 5 4 3 2 1
OUTPUT
16 15 14 13 12 11 10 9
8 7 6 5 4 3 2 1
16 15 14 13 12 11 10 9
8 7 6 5 4 3 2 1
OUTPUT
.71
[18]
OUTPUT
1.31 [33.1]
4.56 [115.7]
7.81 [198.2]
9.54 [242.2]
6.39 [162.4]
.23 [5.9]
.17 [4.3]
3.14 [79.8]
6 - 32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTUDE 3/8” INTO THE CHASSIS
(6 PIECES)
4.91
[124.7]
Product # AQ0400IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 10
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
DATE CODE
Manufacturing Label
PN#
S/N
(3 Modules Stacked Version - U Package Type)
3.50
[88.9]
1.75
[44.5]
3.03 [76.8]
5.25 [133.4]
6-32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTRUDE .200” INTO THE CHASSIS
(4 PIECES)
4.875
[123.83]
4.85 [123.2]
.20 [5.1]
INPUT
1
3
5
16 15
14
13
12
11
10
9
8
6
5
4
3
2
1
7
OUTPUT
4.26
[108.2]
3.92
[99.5]
INPUT
1
3
5
3.21
[81.5]
16 15
14
13
12
11
10
9
8
6
5
4
3
2
1
7
OUTPUT
2.66
[67.5] INPUT
1
3
2.31
[58.8]
5
1.05
[26.7]
.61
[15.4]
16 15
14
13
12
11
10
9
8
6
5
4
3
2
1
7
OUTPUT
.38
[9.5]
1.31
[33.1]
6-32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTRUDE 3/8” INTO THE CHASSIS
(4 PIECES)
4.91 [124.7]
.71
[18]
.17 [4.3]
.23 [5.9]
3.04
[77.1]
Product # AQ0400IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 11
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
Technical Specification
PARALLEL OPERATION - MULTIPLE UNITS
Chassis configurations for Parallel Units
ACuQor units are available either open-frame or pre-mounted
at the factory. Up to 3 units can be mounted into a chassis, in
either side-by-side or stacked configurations. For a complete list of
options, see the “Part Numbering System” table on the last page,
under “Package Type”, along with the Mechanical Drawings pages.
Only side-by-side configurations can be populated with 500W units,
since each includes a thermal pad underneath.
Interconnection of Parallel Units
ACuQor units mounted in 2 and 3 unit chassis are not connected
together. This allows the physical routing and connectivity of the
external wiring to be customized to each application. The following
table summarizes the recommended wiring to operate multiple
units in parallel:
Specifications of Parallel Units
As a rule, units wired in parallel behave the same as single units.
Any specification will remain unchanged that is expressed in units
of voltage, time, frequency, or efficiency. Specifications expressed
in terms of power, current, or capacitance, should be scaled by the
number of units wired in parallel.
ACuQor units are individually calibrated at the factory, so that the
output voltage vs. output current characteristic is always consistent
(see Vout droop characteristic figures). As such, multiple units will
share output current accurately. Full current is guaranteed from a
bank of multiple units wired in parallel.
Output Connector Signal
Suggested Connection
Behavior with Multiple Units
REMOTE_ENABLE
Wire in parallel
Inputs activated simultaneously
FAN_GOOD
“
Wired-OR outputs – can be pulled low by any unit during an abnormal condition.
AC_POWER_GOOD
“
“
DC_POWER_GOOD
“
“
VOUT(+), VOUT(-)
“
Built-in droop characteristic ensures graceful current sharing.
12V_STANDBY*
“
“
5V_STANDBY
Do not wire in parallel
Fully regulated characteristic does not support current sharing. If placed in
parallel, only the output with the highest set-point will drive current.
*Note: Triple output models only.
Product # AQ0400IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 12
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
INSTALLATION INSTRUCTIONS
General:ACuQorAC/DCpowersuppliesareintendedforuse
as components in industrial equipment. ACuQor units must be
properly installed within end use equipment before they can be
safely applied as described in this document. The suitability of
theACuQor/equipmentcombinationmustbeverifiedthroughend
productinvestigation.
Mounting:RefertotheMechanicalDrawingssection.ACuQor
unitsareprovidedwiththreadedstainless-steelstand-offsorinserts
formounting.Thismountinghardwareisinternallyconnectedto
the input connector protective-earth terminal for functional-earth
EMCcontrol.Anyorientation(vertical,horizontal,etc.)maybe
used.Adequateairspaceshouldbeprovidedoverthefanintake
(top) and exhaust (sides) to allow for exchange of cooling air.
ACuQorisdesignedforapollutiondegree2environment.The
suitabilityoftheenclosedACuQormechanicalassembliesmustbe
verifiedthroughendproductinvestigation.
Encased models: A minimum of 5 mm electrical clearance
shouldbeallowedfromtheconnectorendsofencasedmodels.
Input: Refer to the Connector Details section for input connectorwiring.ACuQorproductsrequireasinglephaseACpower
sourceof100-240V50/60Hznominal.Refertonameplatelabel
for input current ratings. A protective-earth connection is also
required. Minimum wire size of 18 AWG (0.8mm2) is recommended.BothsidesoftheAClineareinternallyfused(seetable
forspecificmodels).Thesefusesarenotuserreplaceable.
MODEL
AQ0300
AQ0400
AQ0500
Input Fuses (in Both AC Lines)
Littelfuse6.3A250V21606.3XEP
Littelfuse6.3A250V21606.3XEP
Littelfuse10.0A250V216010XEP
Product # AQ0400IUxT
Phone 1-888-567-9596
Output: Refer to the Connector Details section for output connector wiring and signal I/O functionality. Refer to nameplate
label for output current ratings. Main DC output (Vout+, Vout-)
pins should use 20 AWG (0.5mm2) wire size. Individual main
outputpinsshouldnotbeloadedtomorethan5.5A.Forcurrents
greaterthan5.5A,multiplemainoutputpins/wiresmustbeused
inparallel.AllsignalI/OpinsarereferencedtoVout-.
EMC:ACuQorproductshavebeentestedtotheEMCspecificationslistedintheElectricalCharacteristicssection.However,end
useequipmentmustbetestedtoverifyEMCcompliance.
Hipot Testing: ACuQor products are rated for Hipot testing
levels of 1500 Vac input to protective-earth, 500 Vac output to
protective-earth, and 3000 Vac input to output. When performing the 3000 Vac input to output test, the test voltage must be
balanced evenly 1500 Vac input and output to protective-earth.
Two oppositely phased test voltage sources or a single test voltagesourcewithexternalbalancingimpedances(capacitors)may
beusedtopreventoverstressinginputoroutputtoprotective-earth
insulationperIEC/ENC60950-1.
Fuses Total
2
2
2
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 13
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 400 W
Grade: Industrial
Ordering Information
PART NUMBERING SYSTEM
The part numbering system for SynQor’s ACuQor AC/DC power supplies follows the format shown in the table below.
Not all combinations make valid part numbers, please contact SynQor for availability.
Family
Output Power
AQ:
ACuQor series
of AC-DC
semi-regulated
output power
supplies
Grade
Range
0300:
0400:
0500:
0600:
300 W
400 W
500 W
600 W
(2 x 300 W)
0800: 800 W
(2 x 400 W)
0900: 900 W
(3 x 300 W)
1000: 1000 W
(2 x 500 W)
1200: 1200 W
(3 x 400 W)
1500: 1500 W
(3 x 500 W)
U: Universal
(85-264 VRMS)
I: (Industrial)
Output Voltage
12: 12 V
1T: 12 V /
5 & 12 V STBY
24: 24 V
2T: 24 V /
5 & 12 V STBY
36: 36 V
3T: 36 V /
5 & 12 V STBY
48: 48 V
4T: 48 V /
5 & 12 V STBY
Thermal
Design
Package Type
E: 1 unit (3"x5")
R: 2 units; flat
S: 2 units; stacked
T: 3 units; flat
U: 3 units; stacked
Options
A: Open frame
C: Encased
Industrial Grade:
IND: Industrial
Example: AQ0400IU2TRCIND
ACCESSORIES
SynQor offers a series of assemblies that can be ordered according to the table below. Mechanical drawings for these
accessories are available for download in pdf format from the SynQor website.
Part Number
Description
AQ-CBL-INPUT1C
AQ-CBL-OUT1C
AQ-CBL-OUT1CD
AQ-CBL-OUT2C
AQ-CBL-OUT2CD
AQ-INSUL1M
AQ-EVAL-PRL3
Input mating cable with pre-stripped wire ends (36” long).
Output mating cables with pre-stripped wire ends (18” long).
Same as AQ-CBL -OUT1C with an additional 8-pins connector.
Output mating cable with connectors on both ends (18" long).
Same as the AQ-CBL-OUT2C with an additional 8-pins connector.
Single module bottom-side Mylar insulator for open frame mounting
Evaluation board for up to three paralleled modules.
APPLICATION NOTES
A variety of application notes and technical white papers can be downloaded in pdf format from the SynQor website.
Online Application Notes
Online Library of Technical White Papers
SynQor website.
Contact SynQor for further information and to order:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
Product # AQ0400IUxT
978-849-0600
888-567-9596
978-849-0602
[email protected]
www.synqor.com
155 Swanson Road
Boxborough, MA 01719
USA
Phone 1-888-567-9596
PATENTS
SynQor holds numerous U.S. patents, one or more of which apply to most of its power converter
products. Any that apply to the product(s) listed in this document are identified by markings on
the product(s) or on internal components of the product(s) in accordance with U.S. patent laws.
SynQor’s patents include the following:
5,999,417
6,222,742
6,545,890
6,594,159
6,731,520
6,894,468
6,896,526
6,927,987
7,050,309
7,072,190
7,085,146
7,119,524
7,269,034
7,272,021
7,272,023
7,558,083
7,564,702
7,765,687
7,787,261
8,023,290
8,149,597
8,493,751
8,644,027
WARRANTY
SynQor offers a two (2) year limited warranty. Complete warranty
information is listed on our website or is available upon request from SynQor.
www.SynQor.com
Doc.# 005-005053 Rev. C
08/24/15
Page 14