POWERLINE 4 Watt Single /Dual Output Features - recom

Features
Regulated
Converters
●
●
●
●
●
●
●
●
Ultracompact AC-DC Power Supply
4 Watt PCB Mount Package
Universal Input Voltage Range including 277VAC
3kVAC Isolation (Class II)
Very Low No Load Input Current
Dual output version for standby relay circuits
Short Circuit Protected
UL Certified
POWERLINE
AC/DC-Converter
Selection Guide
Part
Number
RAC04-3.3SA
Input
Range (VAC)*
(Std)
(/277)
90-264
90-305
Output
Voltage
(VDC)
3.3
Output
Current
(mA)
1200
Efficiency
(%)
68
Max
Capacitive
Load
14000µF
RAC04-05SA
90-264
90-305
5
800
72
8000µF
RAC04-09SA
90-264
90-305
9
444
76
2400µF
RAC04-12SA
90-264
90-305
12
333
77
1000µF
RAC04-15SA
90-264
90-305
15
267
77
700µF
RAC04-24SA
90-264
90-305
24
167
77
220µF
RAC04-0512DA
90-264
90-305
5/12
120/250
77
4700/330µF
4 Watt
Single /Dual
Output
* add suffix /277 for 90-305VAC input. High input voltage converters are identified by omitting pin 1.
Specifications (typical at 25°C and after warm up time unless otherwise specified )
standard
/277 versions
90-264VAC or 120-370VDC
90-305VAC or 120-430VDC
RAC04
Rated Power
4 Watts max
Input Frequency Range (for AC Input)
Input Current (full load)
115/230VAC
No Load Power Consumption
115/230/277VAC
Inrush Current (<0.5ms)
115/230VAC
Leakage Current
Output Voltage Accuracy (full load)
single outputs
Dual output version
5V/12V
Line Voltage Regulation (low line, high line at full load)
Dual output version
5V/12V
Load Voltage Regulation
3.3V output
( 0% to 100% full load )
All others
Dual output version
5V/12V
Output Ripple and Noise
3.3V, 5V output
(20MHz limited)
All others
15/25A max.
0.3mA max
±2%
±5%/±2%
±0.2% typ
±3%/±0.2% typ
±1% typ
±0.5% typ
±5%/±0.5% typ
150mVp-p max
100mVp-p max
132kHz typ
single outputs
5V/12V
RMS Isolation Voltage (input to output)
15ms min.
0%
1%/0%
3kVAC / 1minute
Temperature Coefficient
100 MΩ max
Short Circuit Protection
Hiccup, Automatic Restart
All others
Dual output version
Storage Temperature Range
Zener Clamping Diode
-40°C to +70°C
-25°C to +70°C
-55°C to +125°C
Humidity
95% RH max
Case Material
Epoxy with Fibreglass (UL94V-0)
Package Weight
26g
Packing Quantity
EMC
Conducted and Radiated
Noise Immunity
12 pcs
EN 55022 Class B
EN 55024
using MIL-HDBK-217F
>350 x 103 hours
MTBF (+25°C)
PA-4
RAC04
Description
The RAC04 series is an ultra-compact universal input
AC/DC power module for PCB mounting.
It features ultralow no-load power consumption, short
circuit, overload and output overvoltage protection as
well as a built-in EMC Class B filter. A high input
voltage version (suffix /277) is also available for input
voltages of up to 305VAC or 430VDC.
±0.02%/°C typ
Isolation Resistance
Output Overvoltage Protection
Operating Temperature Range
(natural convection, with derating)
UL-60950-1 Certified
E196683
(/277 Version UL Pending)
150/210/220mW typ.
Operating Frequency
Hold-up time
Minimum Load
RoHS
2002/95/EC
6/6
47-440Hz
95/65mA max.
REV: 2/2010
Derating Graph (Ambient Temperature)
125
Natural Convection
100
Output Power (%)
Input Voltage Range
75
Dual
Output
Version
50
40
3.3V and 5V /277
at Vin=305VAC
25
0
-40
80 90 100
45 60
50
70
Ambient Temperature Range (°C)
-25 0
Please Read Application Notes
www.recom-electronic.com
RAC04-SA
Series
POWERLINE
AC/DC-Converter
Typical Characteristics
Efficiency / Input Voltage (Full Load)
Efficiency / Load
90
100
80
85
RAC04-24SA
RAC04-24SA/277
60
Efficiency %
Efficiency %
RAC04-24SA/277
75
40
20
0
RAC04-24SA
80
0% 20%
40%
60%
Total Output current (%)
80%
100%
70
65
90
180
115
264
230
305
Input Voltage (VAC)
Standard Package Style and Pinning
36.7
3rd angle
projection
27.2
17.1
4.0
0.60
21.0
Pin Connections
3.1
7.5
21.5
7
21.0
6
Pin #
5
Bottom View
3.8
2
3 4
3.75 x 2
21.5
1
NC
NC
No Pin
2
+VDC out
+12V
same
3
-VDC out
Com
same
4
NC
+5V
same
5
VAC in (L)
VAC in (L)
VAC in (L)
6
VAC in (N)
VAC in (N)
VAC in (N)
7
NC
NC
NC
NC = No Connection
It is recommended to additionally bond the /277 version of the converter
to the PCB if the application is subject to vibration or mechanical shock.
RAC04
1 /277 Versions
omit Pin 1
Single Output Dual Output /277 Versions
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Standard Application Circuit
Standby Relay Application
With 110VAC supply and 10mA
standby load, the circuit
consumes typically only 150mW.
Once activated by the remote
handset, the standard 12V relay
can switch a 16A load.
L
Fuse
VACin (L)
+12V
Relay
+5V
IR receiver
VACin (N)
N
Vout-
To Application
IR transmitter
Compact single output regulated
power supply
L
Fuse
VACin (L)
Vout+
C1(Optional)
0.1uF
25V
Suggested fuse rating:
1A Slo Blo
www.recom-international.com
N
VACin (N)
REV:2/2010
C2(Optional)
47uF
50V
Load
VoutPA-5