RACD100 - recom

Features
LED DRIVER
●
●
●
●
●
●
●
High Output Voltage
Universal AC Input
Constant Current Operation
Active Power Factor Correction
IP67 Design for Indoor and Outdoor Use
Compact Size
Digital PWM and Analogue Voltage Dimming
LIGHTLINE
AC/DC-Converter
with 5 year Warranty
Selection Guide
Part
Number
Nominal
Voltage
(VAC)
Rated
Voltage
(V)
Output Voltage
Range
(VDC)
Rated
Current
(mA)
Efficiency
typ.
(%)
RACD100-700A
100-277
142
100-142
700
91
RACD100-1400A
100-277
71
50-71
1400
91
100 Watt
Single
Output
Specifications (measured at 240V AC and 25°C ambient temperature)
2/Input Voltage Range
Input Frequency Range
Power Factor
DC Dimming
PWM Dimming
THD
AC Current
Full Load, 115VAC
Full Load, 230VAC
70% Load
Open = 100%
Open = 100%
Freq.
Voltage
Full Load, 115VAC
Full Load, 230VAC
Full Load, 277VAC
115VAC
230VAC
90-305 VAC or 127-430VDC
47-63Hz
>0.98
>0.94
>0.90
DC 1-10V
Duty 10% - 100%
500Hz - 3000Hz
Hi=10V, Low=0V
8% max.
15% max.
17% max.
1.2A max.
0.6A max.
3.75kVAC / 1minute
1.8kVAC / 1minute
0.5kVAC / 1minute
<0.75mA
50A
Input/Output Isolation
Input/Case Isolation
Output/Case Isolation
Leakage Current
230VAC
Inrush Current
230VAC
(Class C Circuit Breaker is recommended)
Voltage Tolerance
-1% to 5%
Current Tolerance
±5%
Start-up Time (@ Full Load)
230VAC
2s
Ripple & Noise
142V Version
1000mV max.
(@20MHz bandwidth)
71V Version
500mV max.
Over Voltage
110 - 140% Rated Voltage
Shutdown Mode
Short Circuit Protection
Hiccup Mode
Over Temperature Protection
100°C ±10°C
Operation Temperature
without derating
-30°C to +55°C (see graph)
Operation Humidity
20%-90% RH Non-Condensing
Storage Temperature
-40°C to +80°C
Storage Humidity
10%-95% RH
Vibration
10-500Hz, 2G, 60 Min. along X, Y and Z
IP Rating
IP67
Safety Standards
UL/cUL LED Lighting Safety
UL8750
CE LVD Directive, Safety
EN61347-2-13
CB
Report: 1103631 001
IEC61347-2-13
continued on next page
L-62
REV: 0/2015
RoHS
2011/65/EU
6/6
E340696
UL 8750 Certified
EN 61347 Certified
RACD100-A
Derating-Graph
(Ambient Temperature)
Load
100%
100V
80%
230V
60%
40%
20%
-30
-10
10
30
50
70
55
Ambient Temperature (°C)
Refer to Application Notes
www.recom-power.com
RACD100-A
Series
LIGHTLINE
AC/DC-Converter
Specifications (measured at 240V AC and 25°C ambient temperature)
EMC Standards
EMC Compatibility
EN55015
FCC, Part 15
EN61000-3-2 Class C
EN61000-3-3
EN61000-4-2, 3, 4, 5, 6, 11
EN61547
177*57*37mm
750g
70 x 10³ hours max.
200 x 10³ hours min.
Harmonic Current
EMC Immunity
Dimension
Weight
Design Lifetime
MTBF
using MIL-HDBK-217F (25°C)
Note:
All LED Drivers may not be used without a load. They must be switched on the primary side only. Noncompliance may damage the LED or reduce its lifetime.
Derating Curves
Load
100%
80%
80%
60%
60%
40%
40%
20%
20%
90
100
130
180
220
240
DC Voltage Dimming Curve
Efficiency (%)
Ta=25°C
100%
305
Input Voltage (VAC)60Hz
10
20
30
40
50
60
70
80
90
PWM Dimming Curve
Iout (%)
Iout (%)
100%
100%
10%
10%
100
0
1
Dimming (%)
Vdim (V)
0 10%
10
Note: Resistor dimming is only possible with a digital
potentiometer (current sink), like the RECOM REPOT
Ddim (%)
100%
Pule: Hi = 10V, Low = 0V
Frequency: 500 - 3KHz
Maximum Number of LED drivers per circuit breakers
Condition
230VAC, 1Ohm
90° phase angle
277VAC, 1Ohm
90° phase angle
Circuit Breaker Current
Typ
10A
16A
20A
25A
C
7
12
14
18
B
6
10
12
14
C
13
22
24
31
B
7
11
14
17
C
15
25
29
36
RACD100-A
115VAC, 1Ohm
90° phase angle
Circuit Breaker
Package Style and Pinning
10.5
5.3
15.0
6.7
300±20
AC/L (Brown)
AC/N (Blue)
Earth (Green/Yellow)
177.0
Tc
57.0
42.0
300±20
30.6
18AWG x 2C
+V(Red)
-V(Black)
+Dim (Blue)
-Dim (White)
188
37.0
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 0/2015
L-63