TFS121B

Filename: tfs 121b.doc
Version 1.5
VI TELEFILTER
21.02.2006
Filter specification
TFS 121B
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
0
°C
dBm
50 Ω
50 Ω
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 121B is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 121,5 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss
(reference level)
ae
1,25
Nominal frequency
fN
-
fN ± 25
dB
dB
2,8
Relative attenuation
2,20
3,00
5,00
8,00
max.
±0,5
dB
MHz
kHz
dB
BW
Bandwidth
±
±
±
±
2,5
121,5
-
Pass band ripple
fN
fN
fN
fN
max.
PB
Passband
1
3
dB
tolerance / limit
MHz
MHz
MHz
MHz
…
…
…
…
fN
fN
fN
fN
±
±
±
±
3,00
5,00
8,00
20,00
arel
MHz
MHz
MHz
MHz
Input power level
Operating temperature range
OTR
± 25
-
min.
min.
min.
min.
5
15
20
40
dB
dB
dB
dB
-
max.
15
dBm
-
- 40 °C ... + 85°C
22
35
53
dB
dB
dB
-
Storage temperature range
Temperature coefficient of frequency
min.
MHz
TCf *
-32
KHz
- 45 °C ... + 90°C
ppm/K
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 121b.doc
Version 1.5
VI TELEFILTER
21.02.2006
Filter specification
TFS 121B
2/5
0
0
-10
-0.5
-20
-1
-30
-1.5
-40
magnitude in dB
magnitude in dB
Filter characteristic
-50
-60
-2
-2.5
-3
-70
-3.5
-80
-4
-90
-4.5
-100
110
115
120
frequency in MHz
125
130
-5
135
120
120.5
121
121.5
122
frequency in MHz
122.5
123
Construction and pin connection
(All dimensions in mm)
S 121B
● U08
3
Date cod e
2 Max.
1
Input
Ground
Ground
Ground
Ground
Ground
Output
Ground
Ground
Ground
Ground
Ground
Date code:
U
V
W
...
Year + week
2006
2007
2008
1
5,2 Max.
2,54 ±0,2
7,2 Max.
2,54 ±0,2
1
1
2
3
4
5
6
7
8
9
10
11
12
0,80
50 Ω Test circuit
L1
1
7
L2
SAW
2, 3, 4, 5, 6, 8, 9, 10, 11, 12
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 121b.doc
Version 1.5
VI TELEFILTER
21.02.2006
Filter specification
TFS 121B
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,50 ± 0,1
Bo
: 7,50 ± 0,1
Ct
: 13,5 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 121b.doc
Version 1.5
VI TELEFILTER
21.02.2006
Filter specification
TFS 121B
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 121b.doc
VI TELEFILTER
Version 1.5
Filter specification
21.02.2006
TFS 121B
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
28.07.2005
1.1
- Add bandwidth@1dB
Strehl
30.08.2005
1.2
- Change teminating impedance
Sabah
26.09.2005
1.3
- Generation of Filter specification and add of typical values
Sabah
27.10.2005
1.4
- Change insertion loss and relative attenuation
- Change stability characteristics
- Correct filter characteristic
Strehl
08.02.2006
Strehl
21.02.2006
1.5
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.