TFS1200

Filename: tfs 1200.doc
Version 1.3
VI TELEFILTER
09.06.2006
Filter specification
TFS 1200
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
168Ω // -1,0pF
168Ω // -1,0pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 1200 is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 1200,0 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss
(reference level)
ae
3,25
Nominal frequency
fN
-
Centre frequency
fC
PB
Passband
Relative attenuation
fN
… fN
±
fN ±
3
MHz … fN
6
MHz … fN
fN ±
17
MHz … fN
fN +
30
MHz … fN
fN +
17
MHz … fN
fN Group delay ripple within PB
±
±
+
+
-
0,1
6
17
30
180
1150
arel
MHz
MHz
MHz
MHz
MHz
MHz
Input power level
Operating temperature range
OTR
Storage temperature range
max.
TCf **
6,0
1200,0
MHz
dB
MHz
fN
0,3
dB
max.
0,3
± 100,0
1,0
kHz
dB
dB
max.
1
dB
20
28
33
43
39
19
dB
dB
dB
dB
dB
ns
min.
min.
min.
min.
min.
max.
15
20
25
30
30
100
dB
dB
dB
dB
dB
ns
26
dBm
max.
15
-
- 40 °C ... + 85°C
-
- 45 °C ... + 90°C
40
Frequency inversion temperature
Temperature coefficient of frequency
dB
p-p
Pass band ripple
1200,0
tolerance / limit
0,05
°C
ppm/K
dBm
2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fTo(MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 1200.doc
Version 1.3
VI TELEFILTER
09.06.2006
Filter specification
TFS 1200
2/5
Filter characteristic
-20
magnitude in dB
magnitude in dB
-10
-30
-40
-50
-60
1065
1092
1119
1146
1173
1200
1227
frequency in MHz
1254
1281
1308
-2
0.45
-4
0.4
-6
0.35
-8
0.3
-10
1335
0.5
1199
1199.5
1200
1200.5
frequency in MHz
1201
delay in µs
0
0
0.25
1201.5
Construction and pin connection
(All dimensions in mm)
C00
● U23
1
2
3
4
5
6
7
8
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
Date code:
U
V
W
...
Year + week
2006
2007
2008
50 Ohm Test circuit
2
6
1, 3, 4, 5, 7, 8
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Filename: tfs 1200.doc
Version 1.3
VI TELEFILTER
09.06.2006
Filter specification
TFS 1200
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 4,30 ± 0,1
Bo
: 4,30 ± 0,1
Ct
: 9,5 ± 0,1
t
P1
Date Code
Po
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Filename: tfs 1200.doc
Version 1.3
VI TELEFILTER
09.06.2006
Filter specification
TFS 1200
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Filename: tfs 1200.doc
VI TELEFILTER
Version 1.3
Filter specification
09.06.2006
TFS 1200
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
13.06.2005
1.1
- Change of input power level to +15dBm
Sabah
06.07.2005
1.2
- Add of typical values and typical filter performances
Sabah
06.07.2005
1.3
- Improve limit line scheme
- Change filter characteristic
Noack
09.06.2006
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information