TFS1220E

Filename: tfs 1220E.doc
Version 1.0
VI TELEFILTER
17.10.2006
Filter specification
TFS 1220E
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
95 Ω || -0.3 pF
95 Ω || -0.3 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 1220 is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter
attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 1220,0 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss
ae = amin
4,0
Nominal frequency
fN
-
Centre frequency
fc
1220
dB
Variation/ Limitation
max.
4,5
dB
(reference level)
Passband ripple
(P-P)
within fN ± 100 KHz
Group delay ripple within fN ± 100 KHz
Relative attenuation
fN
....... fN ±
0,1 MHz
fN ± 4 MHz ....... fN ±
5 MHz
fN ± 5 MHz ....... fN ±
6 MHz
fN ± 6 MHz ....... fN ±
20 MHz
fN + 20 MHz ....... fN + 180 MHz
fN - 20 MHz ....... fN - 1150 MHz
0,4
43
arel
0,4
25
28
37
35
45
1220
MHz
dB
max
1
dB
ns
max. 100
ns
dB
max.
1
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
10
12
14
30
30
dB
dB
dB
dB
dB
max.
10
dBm
Input power level
Temperature coefficient of frequency
Frequency inversion temperature
TCf **
MHz
-0,05
ppm/K²
40
°C
Operating temperature range
- 40 °C ... + 85 °C
Storage temperature range
- 45 °C ... + 90 °C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K²) x (T - TA)² x fCAT (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 1220E.doc
Version 1.0
VI TELEFILTER
17.10.2006
Filter specification
TFS 1220E
2/5
Filter characteristic
0
0
0.5
-1
-10
-2
-30
-4
0.4
-5
-6
-40
0.35
delay in µs
magnitude in dB
-20
magnitude in dB
0.45
-3
-7
-8
-50
0.3
-9
-60
1100
1150
1200
1250
1300
frequency in MHz
-10
1350
1219
1219.5
1220
1220.5
frequency in MHz
1221
1221.5
0.25
Construction and pin connection
(All dimensions in mm)
7
C20E
● U40
1
SQ 3,81 + 0,2/-0,1
5
1
2
3
4
5
6
7
8
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
Date code:
U
V
W
...
Year + week
2006
2007
2008
3
7
5
0,1
12
0%
0,6
%
d
3
1,78
2,54
1
1,2 Max.
Dat e code
1,78
50 Ω Test circuit
2
L1
6
L2
SAW
C1
C2
1, 3, 4, 5, 7, 8
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Filename: tfs 1220E.doc
Version 1.0
VI TELEFILTER
17.10.2006
Filter specification
TFS 1220E
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 4,30 ± 0,1
Bo
: 4,30 ± 0,1
Ct
: 9,5 ± 0,1
P1
Date Code
Do
P2
W
G
Ct
Bo
F
G
E
t
Po
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Filename: tfs 1220E.doc
Version 1.0
VI TELEFILTER
17.10.2006
Filter specification
TFS 1220E
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Filename: tfs 1220E.doc
VI TELEFILTER
Version 1.0
Filter specification
17.10.2006
TFS 1220E
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of filter specification according to customer specification
Noack
17.10.2006
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information