F15-1**, -2**, -3**, -4** Series
Flange mount Flameproof vertical switch
Flameproof switch with flange mounting and manual check system
II 1 / 2 G D
Ex d IIC T4 (Tamb = -50ºC to +100ºC)
Ex tD A20/A21 T110ºC IP6X
Max Process Temp 100ºC
for use in Zones 1 and 2
One, two, three, or four switch levels
Switch configurations of SPST or SPDT reed switch
contacts for high reliability
Enclosure Stainless Steel 316L , Viton O ring IP68
All are custom built to suit particular applications,
based on information provided
The F15 series are vertical float switches
that are top mounted, via a flange
connection, from the outside of the tank.
Access to the inside of the tank is not
required for fitting the float switch.
These can be made with either 1, 2, 3 or 4
point level switches of either SPST or SPDT
action. The electrical loom is fully
insulated and encapsulated within the
stem of the device.
Designed to withstand the most arduous
applications, they are suitable for use in
Water, Diesel, Oil and hydraulic tanks and
reservoirs, as well as Chemical and Petrochemical storage and process control.
The float or floats follow the level of the
liquid and operate the SPST or SPDT switch
elements within the stem.
This type has a manual check system that
moves the floats, thereby checking the
integrity of the switches and wiring on full
or empty tanks. Padlock supplied to
disable check facility, when switch is in
normal operation.
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:[email protected]
ISO9001 C E R T I F I E D
Technical Specification
Float Material
Stainless Steel, D300 (PVC), Buna
Stem Material
Stainless Steel 316L
Temp. Range °C
-20 / +100
°F
-4 / +212
Min. Fluid SG
dependant on float type
Conduit entry
M20x1.5
Standard Flange
1 ½” ASA 150 RF, others are available
Minimum high level
100mm from flange
Maximum low level
2700mm from flange
Terminations
Klippon screw type MK12
Maximum pressure
dependant on length
MaximumLength (Depth)
3 metres
Electrical Specification
SPST
SPST
Switching Power Max
VA
25
100
Switching Voltage AC Max
V
240
250
Switching Voltage DC Max
V
120
250
Switching Current Max
A
0.6
3
All ratings are for resistive load only.
SPDT
25
250
250
1
SPDT
60
250
250
3
Applicable Standards
Low voltage directive
PED directive, where applicable
Lloyds Type Approved
ATEX directive EC Type Examination Cert No BAS01ATEX2265
All are custom built to suit particular applications, based on information
provided. Please contact Cynergy3 with your requirements.
Information that is normally required:
The application and fluid in which the float switch will be used
The Specific Gravity, SG, of the fluid
The maximum temperature of the fluid
Will the float switch be fitted in a tank that is pressurised
The required flange mount size (If unknown we can specify)
The distance from the mounting face of the float switch to the switching
point or points. The switching action required at the switch points 'make on rise' or ‘make on fall'
www.cynergy3.com
© 2013 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.