PDF - Osram

product details
QT-D/E 1X9-13/230-240 UNV1
Product description:
EAN/ Product:
Quantity:
QT-D/E 1X9-13/230-240 UNV1 1)
4050300025827
Unpacked (UNV) contains 1 Piece (PCE)
Applications
Dimmable
NO
Lamp start
Preheat start within 1.5 s 2)
General Description
Design / version
ECG standard
SEG no.
7980076
Standards
acc. to DIN VDE 0875/CISPR 15/EN 55015 | acc. to EN 61547 | acc. to IEC 610003-2/EN 61000-3-2 | acc. to EN 61347-2-3 / IEC 61347-2-3
Energy Label - EEI
A2
Sstl-Number
4030429
Technical - Electrical Data
Operating frequency
? 40 kHz
TH full width at half maximum
310 µs
Lamp wattage
13 W
Power factor c
0.99
Nominal voltage
230 V
DC voltage
176...254 V 3)
IP inrush current
11 A
Max. no. of ECGs on circuit breaker 10A
17
Max. no. of ECGs on circuit breaker 16A
28
Technical - Geometries
Mounting hole spacing, length
96 mm
Wire preparation length, output side
8.5 ... 9.5 mm
Wire preparation length, input side
8.5 ... 9.5 mm
Technical - Light Technical Data
Luminous flux
900 lm
Technical - Temperatures
Maximum casing temperature in the event
110 °C
Maximum operating temperature at the Tc
70 °C
Ambient temperature range
-10 ... +50 °C
Storage temperature
-40 ... 85 °C
Relative humidity
5 ... 85 % 4)
Packaging units
EAN
Packaging type and content
Dimensions in h x w x l
Gross weight
Volume
4050300025827
Unpacked contains 1 Piece
0,000 mm x 0,000 mm x 0,000 mm
0,000 kg (0,116 kg)
0,000 Cubic
dec.
4050300258065
Shipping carton box contains 20 Piece
85,000 mm x 210,000 mm x 315,000 mm
2,500 kg (2,320 kg)
5,623 Cubic
dec.
1)
Battery voltage may drop to 176V. Lamps must be ignited at over198V however. Same luminous flux with direct
current and alternating current
28.08.2008
Amalgam lamps such as DULUX T/E IN (red stamp) are not suitable for outdoor lighting (t<sub>a</sub> < 5°C)
Subject to change without notice. Errors and omission excepted.
or in most emergency lighting applications where a fast run-up is necessary
2)
If there is a temporary interruption in the power supply (< 0.5 sec.) the lamp will start within 0.3 sec.
3)
Ignition must take place above 198 V
4)
max. 56d/y at 85%
© 2008 OSRAM GmbH
Page 1 from 2
QT-D/E 1X9-13/230-240 UNV1
product details
system overview
operation of ecg with
Length in
mm
Number of
lighting
outlet
Length in
mm
Width in
mm
Height in
mm
System
power
consumptio
n in W
(ECG)
System
power
consumptio
n in W
(CCG)
DULUX S/E 9
144 mm
1
93 mm
58 mm
29 mm
12 W
640 lm
1.06
DULUX S/E 11
214 mm
1
93 mm
58 mm
29 mm
14 W
850 lm
0.96
DULUX D/E 10
103 mm
1
93 mm
58 mm
29 mm
12 W
600 lm
1
DULUX D/E 13
131 / 106
mm
1
93 mm
58 mm
29 mm
14 W
850 lm
0.96
L 13
517 mm
1
93 mm
58 mm
29 mm
15 W
DULUX T/E 13
131 / 106
mm
1
93 mm
58 mm
29 mm
14 W
19 W
System
power
consumptio
n in W
(LLB)
17 W
Luminous
flux with
ECG in
lumen
950 lm
850 lm
Luminous
flux in
lumen
(CCG)
950 lm
Power
factor
1
0.96
28.08.2008
Subject to change without notice. Errors and omission excepted.
© 2008 OSRAM GmbH
Page 2 from 2