ROHM BP5728

Data Sheet
100-200VAC Input/12W Output
Isolated AC/DC Converter
BP5728
Absolute Maximum Ratings
Dimensions (Unit : mm)
Unit
VD
VFB
VDD
IDD
PD
Tcmax
Topr
Tstg
800
−0.2 to +6
24
8
0.64
105
−25 to +80
−25 to +105
V
V
V
mA
W
°C
°C
°C
Electrical Characteristics
18.8MAX.
1
3.25MAX.
Symbol
VDD
fo
VDD on
VDD off
Duty MAX
Ioz
Min.
8.9
59
15.5
7.7
68
0.85
Typ.
12
65
16.5
8.3
75
1.15
Max.
20
71
17.5
8.9
82
1.45
Unit
Parameter
Over drain current
protection
Symbol
VDD
10V
15V
20V
Min.
217
269
314
Typ.
247
302
349
Max.
281
338
388
Conditions
R1
+
T1
R2
0.8
IFB=0.5mA
VDD=0→17.5V
VDD=17.5→0V
IFB=0.5mA
IFB=0→1.55mA
Unit
0.7
Conditions
VD=0→15V
mA
SW1=R2
BP5728
AC80 to 154V(100V )
AC154V to 286V(200V )
R3
Vo
C4
NP
NS
C7
D2
6
3
2
1
IC1
0.4
0.3
0.1
R4
ND
PC1
R6
R7
C13
R5
-10
10
30
50
70
Ambient Templature Ta /
80
70
60
50
40
30
20
10
0
0
C12 R9
IC2
200
400
600
800
Pin
No. Terminal name
Terminal function
Common terminal at primary side
1
COM
2
FB
Feed back terminal
3
VDD
Power supply terminal for internal drive
6
VD
Drain terminal for built-in FET
R8
Load regulation
(In case of 12V output)
Output charasteristic
(Vi=311V, Ta=25°C)
14
12
10
8
6
4
2
0
: C5 is charged by R2 when the power is on, and the switching starts
0
500
1000
1500
Output current / mA
when the voltage at VDD pin reaches the voltage threshold (17.5V max.)
Vdd
is
supplied
via
Nd
and
FB
current
flows
to
PC1
once
Vo
exceeds
the
threshold
voltage.
Once
PC1
2.During operation
:
turns ON a current Ioz flows through the transistor.
Also, FB current runs to Pin 2 of BP5728 when Vo exceeds the designed voltage and the constant voltage control is executed.
3.In overcurrent conditions : The input current will increase if the output power increases, and the overcurrent protection circuit will turn
ON once the Drain current exceeds the specified value (Idocp).
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
IC2 :
FL1 :
R1 :
R2 :
R3 :
R4 :
R5 :
R6 :
R7 :
R8 :
R9 :
PC1 :
T1 :
ZNR1 :
Rated at 300VAC or higher
0.1 to 0.22µF
22µF / 450V
2200pF / 1kV
10µF / 50V
470µF / 35V low impedance
0.1µF / 50V
2200pF / AC250V
FRD 800V / 0.5A
80V / 0.1A
SBD 90V / 3A
800V / 1A
Use for safety
BP5728
1/1
1000
Output current / mA
Operating Principle
1.When turned on
External Component Specifications
C1,C2 : Noise reduction capacitors
C3 : Input smoothing capacitor
C4 : Noise reduction capacitor
C5 : Vdd smoothing capacitor
C7 : Output capacitor
C12 : Phase compensation capacitor
C13 : Noise reduction capacitor
D2 : Rectifier diode
D3 : Rectifier diode
D4 : Rectifier diode
DB : Diode bridge
F1.F2 : Fuse
IC1 : BP5728
90
°C
Conversion Efficiency
(In case of 12V output)
D3
C5
Operation range
0.2
GND
F2
Tsmax=105°C
0.5
Conversion efficiency
(Vi=311V, Ta=25°C)
12V/0.5A(100V )
12V/1A(200V )
D4
0.6
0
-30
Output voltage / V
C3
4.35MAX.
Derating curve
−
V
kHz
V
V
%
mA
+
DB
C2
0.25±0.05
5.55MAX.
90
+
C1
6
0.5±0.1
1.3±0.2
Derating Curve
Conversion efficiency / %
Be sure to use fuse for safety.
FL1
ZNR1
3
2.54±0.2
Application Circuit (In case of 12V output)
F1
2
2.54X5=12.7TYP.
(VDD=15V, Vd=15V,IFB=0.1mA,SW1=R1,Ta=25°C, unless otherwise specified)
Parameter
Input voltage
Output frequency
Turn on voltage
Turn off voltage
Maximum Duty
Zero-Duty IFB
Idocp
9.9MAX.
MARKING SIDE
Allowable loss / W
6pin Input Voltage
2pin Input Voltage
3pin Input Voltage
3pin Input Current
Allowable Loss
Max Surface Temperature
Operating Temperature Range
Storage Temperature Range
MARKING SIDE
Limits
19.5MAX.
Symbol
4.0±1.0
Parameter
Shunt regulator
Noise reduction filter
Resistor
Resistor
Resistor
Resistor
Resistor
Resistor
Resistor
Resistor
Resistor
Photo coupler
Switching transformer
Varistor
2000
Vref=2.495V
Use if necessary
0Ω
750kΩ 0.5W / 600V
200kΩ / 3W
51Ω / 0.125W
1kΩ / 0.1W
15kΩ / 0.1W
3kΩ / 0.1W
4.7kΩ / 0.1W
1kΩ / 0.1W
PC817
SRW25ES-47V015(TDK)
A varistor is required to protect against
lightning surges and static electricity.
2010.01 - Rev.A
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specified in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices).
The Products specified in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, fire or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any
of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
R1010A