ZSSC4151 Evaluation Kit Start-up Guide Rev. 1.00

SSC Evaluation Kit
Rev. 1.00 / September 2015
ZSSC4151
ZSSC4151 Evaluation Kit Start-up Guide
Multi-Market Sensing Platforms
Precise and Deliberate
ZSSC4151
Evaluation Kit Start-up Guide
Important Notes
Restrictions in Use
ZMDI’s ZSSC4151 SSC Evaluation Kit, consisting of the SSC Communication Board (SSC CB), ZSSC415x/6x/7x Evaluation Board (SSC
EB), Sensor Replacement Board (SSC RB), and ZSSC41xx Software, is designed for sensor module evaluation, laboratory setup, and
module calibration development only. ZMDI’s SSC Evaluation Kit hardware and software must not be used for module production or
production test setups.
The related product ZSSC41xx SSC Mass Calibration System is designed only for development, evaluation, and laboratory setup of
sensor modules with ZMDI Sensor Signal Conditioner ICs. The ZMDI Mass Calibration System hardware and software must not be used
for module production and production test setups.
Disclaimer
Zentrum Mikroelektronik Dresden AG (ZMD AG) shall not be liable for any damages arising out of defects resulting from
(i) delivered hardware or software
(ii) non-observance of instructions contained in this manual and in any other documentation provided to user, or
(iii) misuse, abuse, use under abnormal conditions, or alteration by anyone other than ZMD AG.
To the extent permitted by law, ZMD AG hereby expressly disclaims and user expressly waives any and all warranties, whether express,
implied, or statutory, including, without limitation, implied warranties of merchantability and of fitness for a particular purpose, statutory
warranty of non-infringement, and any other warranty that may arise by reason of usage of trade, custom, or course of dealing.
Contents
1
2
3
4
5
6
Introduction ....................................................................................................................................................... 4
Setting up Hardware and Software .................................................................................................................. 4
2.1. Hardware Setup ......................................................................................................................................... 4
2.2. Software Setup .......................................................................................................................................... 5
2.3. Activating the Hardware Connection ......................................................................................................... 6
2.4. Creating and Loading the Default Configuration File ................................................................................ 7
2.5. Loading the NVM Dump File ..................................................................................................................... 8
2.6. Writing the Memory Contents to NVM ....................................................................................................... 8
2.7. Taking Measurements ............................................................................................................................... 9
Performing a Sample Calibration ................................................................................................................... 10
3.1. Setting up the Calibration and Acquiring Data ........................................................................................ 10
3.2. Checking the Calibration ......................................................................................................................... 12
3.3. Saving the NVM Data and GUI Configuration Settings ........................................................................... 12
Related Documents and Tools ....................................................................................................................... 12
4.1. ZMDI Related Documents and Tools ...................................................................................................... 12
Glossary ......................................................................................................................................................... 12
Document Revision History ............................................................................................................................ 13
Startup Guide
September 14, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 1.00. All rights reserved. The material contained herein may not
be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
information furnished in this publication is subject to changes without notice.
2 of 13
ZSSC4151
Evaluation Kit Start-up Guide
List of Figures
Figure 2.1
Figure 2.2
Figure 2.3
Figure 2.4
Figure 2.5
Figure 2.6
Figure 2.7
Figure 3.1
Figure 3.2
ZSSC4151 SSC Evaluation Kit Assembly .......................................................................................... 5
Enabling Resizing Window ................................................................................................................. 6
2
Connecting the Hardware via I C™ or OWI ...................................................................................... 6
Loading the GUI Configuration File .................................................................................................... 7
Load the NVM Data into GUI .............................................................................................................. 8
Writing the Configuration into the ZSSC4151 NVM............................................................................ 8
Starting and Monitoring the Measurement Sequence ........................................................................ 9
Using the Calibration Window Tab to Set Upper and Lower Target Limits ..................................... 10
Using the Calibration Window Tab to Acquire Data and Calculate Coefficients ............................. 11
Startup Guide
September 14, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 1.00. All rights reserved. The material contained herein may not
be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
information furnished in this publication is subject to changes without notice.
3 of 13
ZSSC4151
Evaluation Kit Start-up Guide
1
Introduction
This document guides first-time users through the initial hardware setup, software installation, and basic steps for
using the ZSSC4151 IC with the ZSSC4151 SSC Evaluation Kit available from ZMDI. By following this document,
users should gain a quick understanding of the basic operations and options available in the hardware and
software and be able to perform a simple calibration and store the results in non-volatile memory (NVM).
Refer to the ZSSC4151 Evaluation Kit Hardware Manual for an overview of the hardware, schematics, and details
related to the connectors.
The ZSSC4151 Evaluation Kit consists of the following parts:






2
*
SSC Communication Board (SSC CB) V4.1
ZSSC415x/6x/7x SSC Evaluation Board (SSC EB) V1.1
SSC Sensor Replacement Board (SRB) V2.0
6 ZSSC4151 samples (QFN24 4x4mm)
USB cable
Vacuum suction pen (provided for safe handling of IC samples)
Setting up Hardware and Software
2.1.
Hardware Setup
The Evaluation Kit hardware consists of the following three boards as shown in Figure 2.1 and includes samples
of the ZSSC4151 (QFN24):
2
1. SSC Communication Board – Connects to computer through a USB 2.0 cable and handles the I C™
(trademark of NXP) and OWI interfaces between the PC-based software and the ZSSC4151.
2. ZSSC415x/6x/7x Evaluation Board. This board contains a socket for the ZSSC4151 and convenient
access points for connection to instrumentation and external sensor circuitry. Note the location of pin 1
for the QFN24 socket. Jumpers should be installed initially as shown in Figure 2.1.
3. Sensor Replacement Board – See equivalent circuit in Figure 2.1. This board provides a simulated input
signal for easy evaluation of functionality without an actual bridge or stimulus. It should be removed
when connecting an external sensor bridge (through screw terminals on Evaluation Board).
*
For detailed information about SSC Communication Board, please refer to the SSC Communication Board Data Sheet available on the ZMDI website at
http://www.zmdi.com/ssc-tools.
Startup Guide
September 14, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 1.00. All rights reserved. The material contained herein may not
be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
information furnished in this publication is subject to changes without notice.
4 of 13
ZSSC4151
Evaluation Kit Start-up Guide
Figure 2.1 ZSSC4151 SSC Evaluation Kit Assembly
Power Indicator
SSC Communication Board
SSC Sensor
ZSSC415x/6x/7x Evaluation Board Replacement Board
SSC Sensor
Replacement Board
Equivalent Circuit
TOP
Pin 1
2KΩ
BR1P
100Ω
BR1N
2KΩ
BOT
K1 Power Enable Jumper
With the three boards assembled as shown in Figure 2.1, attach the USB cable included in the kit between the
SSC Communication Board and a USB port on a PC. In some cases, the user’s operating system detects the
board type and automatically installs a driver the first time that the SSC Communication Board is connected. For
this reason, the PC should be connected to the Internet during the first USB connection so that the operating
system can download a driver. If a driver fails to install, contact ZMDI for assistance.
2.2.
Software Setup
The ZSSC4151 Application Software provides a user-friendly graphical user interface (GUI). It is available for
download on the ZSSC4151 product page www.zmdi.com/zssc415x. After downloading the software, extract the
zip file contents.
Run the ZSSC415xSetup.exe file from the unzipped location to install the GUI. Launch the ZSSC415x program
from the Start Menu in Windows or by clicking the desktop icon created by the installation program.
To enable resizing the window, go to “SETTINGS” on the top menu and check the “No limits on resizing” as
shown in Figure 2.2.
Startup Guide
September 14, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 1.00. All rights reserved. The material contained herein may not
be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
information furnished in this publication is subject to changes without notice.
5 of 13
ZSSC4151
Evaluation Kit Start-up Guide
Figure 2.2 Enabling Resizing Window
2.3.
Activating the Hardware Connection
2
1. Select I C™ or OWI (One Wire Interface) from the drop-down menu below “Protocol” (see Figure 2.3).
2. Click the “Connect” button. On the Evaluation Board, verify that the green LED power indicator turns on.
The “ACTIVE DEVICES” list on the right side of the “Main” tab menu shows information about the board
and device that are connected.
2
Figure 2.3 Connecting the Hardware via I C™ or OWI
1
2
Startup Guide
September 14, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 1.00. All rights reserved. The material contained herein may not
be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
information furnished in this publication is subject to changes without notice.
6 of 13
ZSSC4151
Evaluation Kit Start-up Guide
2.4.
Creating and Loading the Default Configuration File
1. On the top menu, select FILE > Load GUI Configuration to load a configuration file (Figure 2.4).
2. A default configuration file, ZSSC4151.cfgx, is provided with the software as shown in the “File name”
field in Figure 2.4. If necessary, browse to the file location and click the “Open” button.
3. In the resulting “Load GUI Configuration” window, click the “Yes” button to accept overwriting the current
configuration settings.
Figure 2.4 Loading the GUI Configuration File
1
3
2
Startup Guide
September 14, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 1.00. All rights reserved. The material contained herein may not
be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
information furnished in this publication is subject to changes without notice.
7 of 13
ZSSC4151
Evaluation Kit Start-up Guide
2.5.
Loading the NVM Dump File
1. On the top menu, select FILE > Load NVM Dump to load a file containing the NVM data (see Figure 2.5).
2. A default NVM file, zssc4151_nvm.dmpx, is provided with the software as shown in the “File name” field
in Figure 2.5. Browse to the file location, and click the “Open” button.
3. In the resulting “Load RAM Dump” window, click the “Yes” button to accept overwriting current data.
Figure 2.5 Load the NVM Data into GUI
1
3
2
2.6. Writing the Memory Contents to NVM
1. Click the “Write All To NVM” button to download the NVM data into the ZSSC4151 (see Figure 2.6).
Figure 2.6 Writing the Configuration into the ZSSC4151 NVM
1
Startup Guide
September 14, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 1.00. All rights reserved. The material contained herein may not
be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
information furnished in this publication is subject to changes without notice.
8 of 13
ZSSC4151
Evaluation Kit Start-up Guide
2.7. Taking Measurements
Note: The GUI refers to the bridge sensor measurand as “Pressure,” but this can be any type of resistive sensor
signal. The ZSSC4151 is designed for almost all types of resistive full and half bridge sensors.
1. Click the “Start” button to begin acquiring and recording measurements (see Figure 2.7).
2. With the “Pressure” selected in the “Measurements” pulldown, turn the red knob on the Sensor
Replacement Board (Figure 2.1). The “Pressure” (Green) waveform plot should move up and down with
the knob rotation. The “Temperature” and “Pressure Raw” waveforms can also be displayed using the
“Measurements” pulldown selector, but only one waveform at a time will be displayed.
3. Click the “Stop” button to discontinue measurements.
Figure 2.7 Starting and Monitoring the Measurement Sequence
2
1
Startup Guide
September 14, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 1.00. All rights reserved. The material contained herein may not
be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
information furnished in this publication is subject to changes without notice.
9 of 13
ZSSC4151
Evaluation Kit Start-up Guide
3
Performing a Sample Calibration
This section describes the basic operations to perform a simple, two-point linear calibration at a single temperature. Higher order calibrations are performed similarly, but with additional points taken over the bridge measurand
and temperature.
3.1. Setting up the Calibration and Acquiring Data
1. Select the “Calibration” tab to display the “Calibration” window (see Figure 3.1).
2. Ensure that the “Calibration Type Settings” and “Acquisition Settings” are set as shown in Figure 3.1. The
“Calibration Table” shows that there are only two points required to complete the calibration in this case.
3. Set the upper and lower “Target” limits to 90% and 10%. DO NOT change the “Tgt.Min” and “Tgt.Max”
fields.
Figure 3.1
Using the Calibration Window Tab to Set Upper and Lower Target Limits
1
2
3
Startup Guide
September 14, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 1.00. All rights reserved. The material contained herein may not
be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
information furnished in this publication is subject to changes without notice.
10 of 13
ZSSC4151
Evaluation Kit Start-up Guide
4. Turn the red knob on the Sensor Replacement Board fully counterclockwise. Select the “P1” field and
click the “Acquire Data” button (see Figure 3.2).
5. Turn the red knob on the Sensor Replacement Board fully clockwise. Select the “P2” field and click the
“Acquire Data” button.
6. Click the Calculate button. The coefficients for the calibration will be calibrated and updated in the
calibration formula textbox at the bottom of the window. HINT: Scroll to the bottom of the textbox so that
the “Output” button appears. Move the cursor over the “Output” button. A popup window will appear
showing the complete set of calibration coefficients.
7. Click the “Write Coefficients To NVM” button. This will download the updated coefficients to the NVM of
the ZSSC4151.
Figure 3.2
Using the Calibration Window Tab to Acquire Data and Calculate Coefficients
5
6
4
Startup Guide
September 14, 2015
7
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 1.00. All rights reserved. The material contained herein may not
be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
information furnished in this publication is subject to changes without notice.
11 of 13
ZSSC4151
Evaluation Kit Start-up Guide
3.2.
Checking the Calibration
The calibration can be checked in the “Main” tab.
1. Click the “Start” button in this window and observe the reading to verify readings. If the red knob of the
Sensor Replacement Board has been left in the fully clockwise position as in step 5 in section 3.1, the
calibration at the “P2” calibration point can be verified by checking that the output for “Pressure” is 90%.
2. Similarly, if the red knob is turned fully counterclockwise, the reading should be 10%.
3.3.
Saving the NVM Data and GUI Configuration Settings
The GUI settings and NVM contents for this example can be saved to new configuration and NVM dump files.
Select FILE > Save GUI Configuration from the top menu, and save the configuration under a new name. In a
similar way, the NVM dump file can be saved using FILE > Save NVM Dump and creating a new name.
4
4.1.
Related Documents and Tools
ZMDI Related Documents and Tools
Note: X_xy refers to the current revision of the document.
Document
File Name
ZSSC4151 Data Sheet
ZSSC4151_Data_Sheet_Rev_X_xy.pdf
ZSSC4151 Feature Sheet
ZSSC4151_Feature_Sheet_Rev_X_xy.pdf
ZSSC415x Graphical User Interface Operation Manual
ZSSC415x_GUI_Operation_Manual_Rev_X_xy.pdf
ZSSC4151 SSC Evaluation Kit Hardware Manual
ZSSC4151_EVKIT_Hardware_Manual_Rev_X_xy.pdf
Visit the ZSSC4151 product page www.zmdi.com/zssc415x on ZMDI’s website at www.zmdi.com or contact your
nearest sales office for the latest version of these documents.
5
Glossary
Term
Description
DUT
Device Under Test
GUI
Graphical User Interface
NVM
Nonvolatile Memory
OWI
One-Wire Interface
SSC
Sensor Signal Conditioner
USB
Universal Serial Bus
Startup Guide
September 14, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 1.00. All rights reserved. The material contained herein may not
be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
information furnished in this publication is subject to changes without notice.
12 of 13
ZSSC4151
Evaluation Kit Start-up Guide
6
Document Revision History
Revision
Date
Description
1.00
September 14, 2015
First release.
Sales and Further Information
www.zmdi.com
[email protected]
Zentrum Mikroelektronik
Dresden AG
Global Headquarters
Grenzstrasse 28
01109 Dresden, Germany
ZMD America, Inc.
1525 McCarthy Blvd., #212
Milpitas, CA 95035-7453
USA
Central Office:
Phone +49.351.8822.306
Fax
+49.351.8822.337
USA Phone 1.855.275.9634
Phone +1.408.883.6310
Fax
+1.408.883.6358
European Technical Support
Phone +49.351.8822.7.772
Fax
+49.351.8822.87.772
DISCLAIMER: This information applies to a product under development. Its characteristics and specifications are subject to change without notice.
Zentrum Mikroelektronik Dresden AG (ZMD AG) assumes no obligation regarding future manufacture unless otherwise agreed to in writing. The
information furnished hereby is believed to be true and accurate. However, under no circumstances shall ZMD AG be liable to any customer,
licensee, or any other third party for any special, indirect, incidental, or consequential damages of any kind or nature whatsoever arising out of or
in any way related to the furnishing, performance, or use of this technical data. ZMD AG hereby expressly disclaims any liability of ZMD AG to any
customer, licensee or any other third party, and any such customer, licensee and any other third party hereby waives any liability of ZMD AG for
any damages in connection with or arising out of the furnishing, performance or use of this technical data, whether based on contract, warranty,
tort (including negligence), strict liability, or otherwise.
European Sales (Stuttgart)
Phone +49.711.674517.55
Fax
+49.711.674517.87955
Startup Guide
September 14, 2015
Zentrum Mikroelektronik
Dresden AG, Japan Office
2nd Floor, Shinbashi Tokyu Bldg.
4-21-3, Shinbashi, Minato-ku
Tokyo, 105-0004
Japan
ZMD FAR EAST, Ltd.
3F, No. 51, Sec. 2,
Keelung Road
11052 Taipei
Taiwan
Phone +81.3.6895.7410
Fax
+81.3.6895.7301
Phone +886.2.2377.8189
Fax
+886.2.2377.8199
Zentrum Mikroelektronik
Dresden AG, Korea Office
U-space 1 Building
Unit B, 906-1
660, Daewangpangyo-ro
Bundang-gu, Seongnam-si
Gyeonggi-do, 463-400
Korea
Phone +82.31.950.7679
Fax
+82.504.841.3026
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 1.00. All rights reserved. The material contained herein may not
be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
information furnished in this publication is subject to changes without notice.
13 of 13