ST60 Data Sheet - ARCH Electronics Corp.

VER : PA_2
update : 2015.08.18
Encapsulated DC-DC Converter
ST60 SERIES
60 Watts
KEY FEATURES
 Power Module for PCB Mountable
 Smaller Size
 4:1 Wide Input Range
 Regulated Output
 High Efficiency
 Operating Temperature: -40°C…+85°C (with derating)
 Remote ON/OFF Control
 3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
( Single Output )
ST60-48F-12S
Max Output Wattage (W)
60W
Input
Output
Voltage (with Derating)
48V (18-72V)
Voltage (V.DC.)
12
Trim Voltage Range
10%
Voltage Accuracy
2%
Current (mA) max
5000
Line Regulation (LL-HL) (typ.)
0.5%
Load Regulation (10-100%) (typ.)
1%
Capacitor Load (max) (at 48 Vin)
1000uF
Ripple & Noise
Protection
Isolation
Environment
Physical
Safety
EMC
(Note 1)
ST60-48F-15S
ST60-48F-24S
15
24
4000
2500
680uF
150uF
90%
90%
1% of Vout
Efficiency
91%
Switching Frequency
200KHz
Over Power Protection
Auto-recovery
Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Auto-recovery
Voltage
Resistance
1600 VDC.
108 ohms
Capacitance
2200 pF
Operating Temperature
-40°C…+85°C (with derating)
Storage Temperature
-50°C…+105°C
Case Temperature
+105°C max.
Temperature Coefficient
±0.05%/°C
Humidity
95% RH
MTBF
>550,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
2.08 x 1.08 x 0.55 Inches ( 52.8 x 27.4 x 14.0 mm ) Tolerance 0.5 mm
Case Material
Six-side shielded Aluminum with Non-Conductive base, Black Anodize
Weight
Pending
Cooling Method
Free-air convection
Agency Approvals
EMI
(Note 3)
(Conducted & Radiated Emission)
EMS (Noise Immunity)
CE, UL, cUL (Pending)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
EN 55022 class A (Pending)
EN 55024
(Pending)
-1-
VER : PA_2
update : 2015.08.18
Encapsulated DC-DC Converter
ST60 SERIES
60 Watts
NOTE
1. Ripple & Noise are measured at 20MHz of bandwidth with ceramic 0.1uF & chemi-con KY 47uF parallel capacitor.
A 30cm twisted pair of no.18 AWG copper wire is connected to a
47uF and 0.1uF capacitor of proper polarity and voltage rating.
The oscilloscope probe ground led should connect right to the
ground ring of the probe and be as short as possible.
The oscilloscope bandwidth should be at 20MHz and connected
to AC ground.
2. That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
3.
4. Please refer to our PDF file "DC-DC Application" on our website: www.archcorp.com.tw
MECHANICAL DIMENSION
( Top View )
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
PIN#
Single
1
CTRL
2
-DC IN
3
+DC IN
4
TRIM
5
-DC OUT
6
+DC OUT
TRIM
-2-