480W Single output industrial DIN RAIL with PFC function
(PFC function for DRP-480 only)
Built-in passive PFC function compliance to EN61000-3-2(For DRP-480)
High efficiency 89% and low dissipation
Protections:Short circuit/Over load/Over voltage/Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
Can be installed on DIN rail TS-35/7.5 or 15
UL 508(industrial control equipment)approved
EN61000-6-2(EN50082-2) industrial immunity level
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
OUTPUT
DR-480-24
DR-480-48
DRP-480-24
DRP-480-48
DC VOLTAGE
24V
48V
24V
48V
RATED CURRENT
20A
10A
20A
10A
CURRENT RANGE
0 ~ 20A
0 ~ 10A
0 ~ 20A
0 ~ 10A
RATED POWER
480W
480W
480W
480W
RIPPLE & NOISE (max.) Note.2
120mVp-p
120mVp-p
120mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
24 ~ 28V
48 ~ 53V
24 ~ 28V
48 ~ 53V
VOLTAGE TOLERANCE Note.3
1%
1.0%
1%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1%
1.0%
1%
1.0%
SETUP, RISE, HOLD TIME
1200ms, 40ms, 16ms/230VAC at full load
VOLTAGE RANGE
180 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
INPUT
EFFICIENCY (Typ.)
250 ~ 370VDC
0.7 (for DRP-480)
89%
AC CURRENT
6A/230VAC
INRUSH CURRENT (max.)
COLD START 50A/230VAC
LEAKAGE CURRENT
OVER LOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
4A/230VAC
<3.5mA / 240VAC
105 ~ 150% of rate load
Protection type : Constant current limiting, recovers automatically after fault condition is removed
54 ~60V
30 ~ 36V
30 ~ 36V
54 ~60V
Protection type : Shunt down o/p voltage, re-power on to recover
100
5
(TSW : Detect on heatsink of power switch)
Protection type : Shun down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP., HUMIDITY
-20 ~ +70
(Refer to output load derating curve), 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
ENVIRONMENT
TEMP. COEFFICIENT
-20 ~ +85
, 10 ~ 95% RH
0.03%/
(0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
EMI CONDUCTION & RADIATION
UL508, TUV EN60950 Approved
Compliance to EN55022 (CISPR22) Class B
SAFETY &
HARMONIC CURRENT
Compliance to EN61000-3-2,-3, Class D(For DRP-480)
EMC
EMS IMMUNITY
WITHSTAND VOLTAGE
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
OTHERS
MTBF
180.9Khrs min.
DIMENSION
227*125.2*100mm (W*H*D)
2.1Kgs/pcs, 6pcs/12.6Kgs/1.75CUFT
PACKING
NOTE
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
File Name:DR-480,DRP-480-SPEC 2003-09-19
DR-480/D
UR
S P - 42 82 05
Mechanical Specification
Case No.930
100
series
Unit:mm
125.2
227
TB1
3 2 1
LED
TB2
4 3 2 1
ADJ
35
8.5
Admissible Din Rail: TS35/7.5 or TS35/15
120
TB1 Terminal Pin. No Assignment
Pin No.
1
2
3
54.25
TB2 Terminal Pin. No Assignment
Pin No.
1,2
3,4
Assignment
AC/L
AC/N
FG
Derating Curve
Assignment
DC OUTPUT +V
DC OUTPUT -V
Output Derating VS Input Voltage
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-20
0
10
20
30
40
AMBIENT TEMPERATURE (
50
)
60
70 (VERTICAL)
60
50
40
180
190
200
264
INPUT VOLTAGE (V) 60Hz