www.roassoc.com www.astrodyne.com

Astrodyne Corporation
35 Hampden Road
Tel: (508) 964-6300
Fx: (508) 339-0375
nV300LF
82.5-120 Watts
300 VDC Input
1/2 Brick
NanoVerter Series
The nV300LF NanoVerter modules are high density DC-DC
converters with an input range of 220-400 VDC. These supplies
utilize metal PC boards, planar transformers, and surface mount
construction to produce up to 120 watts in a small package with
maximium reliability. The converters are board mountable with
isolation of 4500 VDC (input to output), are fully encapsulated
with base-plate cooled operation up to 100°C and have been
qualified to international safety standards including the latest
Lead-Free and RoHS requirements. These converters are ideal
for customers who need reliable power conversion in a compact,
conduction cooled package.
Operational Features
• Lead-Free / RoHS Compliant Design
• Small Footprint of only 2.30 x 2.40”
• Low Profile of only 0.42” or 0.32” (recessed mounting)
• Extremely Low Thermal Resistance
• -40 ~ 100°C Baseplate Operation
• Parallelable with Current Sharing
• Secondary Referenced Controls
• Auxiliary (housekeeping) Supply Output (PV pin)
• Logic On-Off
• Safety Agency Approved to UL/cUL 60950 (pending)
• Two Year Warranty
Typical Applications
Model Selection
• Aerospace
• Civil Avionics
• Military / COTS
• Industrial Control
• Telecommunication
CE Mark (LVD)
(pending)
UL / cUL 60950
(pending)
Input
Range
(VDC)
Output
Voltage
(VDC)
nV300-3LF
220-400
3.3
25
nV300-5LF
220-400
5.0
20
nV300-12LF
220-400
12
10
nV300-15LF
220-400
15
8
nV300-24LF
220-400
24
5
Model
Number
Lead
Free
RoHS
Compliant
Output
Current
(Amps)
www.astrodyne.com
www.roassoc.com
Astrodyne USA: 1-800-823-8082
nV300LF
82.5-120 Watt / 300 VDC Input / Half Brick
Specifications:
CATEGORY
INPUT
SPECIFICATION
MIN
TYP
MAX
Input voltage (VDC)
220
300
400
Input reflected ripple
10%
full load, nominal line
Input ripple rejection
60dB
@ 120Hz
No load power dissipation
1.5W
nominal line
Logic disabled power in
0.8W
nominal line
Set point accuracy
± 0.5%
1%
Load regulation
0.1%
0.2%
0 - full load
Line regulation
0.1%
0.2%
220- 400 VDC
1%
3%
0 - 20MHz, 3.3V / 5V outputs
1%
2%
0 - 20MHz, 12V / 15V / 24V outputs
Ripple / Noise
Trim range
Remote sense compensation
OUTPUT
OVP (non shutdown auto. rec.)
+ 5%,- 10% for 3V
0.5V
OVP Limited on 3V model
105%
110%
120%
3V outputs
110%
115%
130%
5V / 12V / 15V / 24V outputs
Current Limit (auto recovery)
115%
full load
Short circuit current
130%
full load
Current sharing (automatic)
± 1%
Vout 1%
See Curves
80- 86%
full load, nominal line
Turn on time (power applied)
150ms
full load, nominal line
Logic turn on time
2ms
full load, nominal line
Logic disabled current
20µ A
2mA PV load
10.3V
main output @ full load
10mA PV load
9.3V
main output @ full load
10.3V
main output disabled
Input to output
4500VDC
Input to case
2500VDC
Output to case
500VDC
Input to output capacity
Operating temperature
THERMAL
200µ s
0.02%/°C
2mA PV load
ISOLATION
full load
20 - 80% FL, 1/2 A/µ s
50µ s
Temperature drift
PV OUTPUT
± 5%
3%
Transient response - Recovery Time
CONTROL
full load
± 10%*
Transient response - Excursion
EFFICIENCY
CONDITIONS
5200pF
- 40°C
Automatic shut down temperature
+100°C
Thermal resistance case to ambient
Storage temperature
+ 100°C
+105°C
Baseplate Temperature
+110°C
Baseplate Temperature
6.6 °C/watt
- 55°C
WEIGHT
3.4oz. (96 grams)
SIZE
0.42 x 2.40 x 2.30” / (10.70 x 60.96 x 58.42mm)
+ 110°C
Ambient Temperature
www.astrodyne.com
www.roassoc.com
Astrodyne USA: 1-800-823-8082
nV300LF
82.5-120 Watt / 300 VDC Input / Half Brick
Output Ripple
(300VDC Nominal Input)
5V Model, 300V Input, 20A Output
Efficiency (Percentage)
Efficiency Curves
Vout
50mv
div
Output Power (Percentage of Load)
1µ s/div
Transient Response
Thermal Performance
Output Power, % of Full Load
5V Model, 4-16-4A, Current Slew Rate 0.5/µ s
Vout
100mv
div
Iout
5A
div
Ambient Temperature (C)
50µ s/div
1 - With no Heatsink or airflow
2 - With 2003 Heatsink and no airflow (or 2.9C/W Heatsink)
3 - With 2003 Heatsink and 200 LFM airflow (or 2.4C /W Heatsink)
4 - With 2003 Heatsink and 400 LFM airflow (or 1.6C/W Heatsink)
5 - Output Power vs. Case Temperature, No De-Rating <100 C
A wide variety of evaluation boards are available for your evaluation
requirements. Our application notes provide circuit design and board
layout details to simplify your design processes.
Our experienced application engineering team is available for “free
engineering evaluation” of your schematic and board layout to ensure
your design is right the first time.
www.astrodyne.com
www.roassoc.com
Astrodyne USA: 1-800-823-8082
nV300LF
82.5-120 Watt / 300 VDC Input / Half Brick
Mechanical Drawing
Recessed Mounting
Conventional Mounting
0.32”
0.42”
Note: Pin Material
* Input and Control Pins are Brass
* Output Pins are Copper
* Pin Finish is Gold over Nickel, JESD97
2nd Level Interconnect Category e4
Note:
Specifications are subject to change without notice
REV 060223-A
www.astrodyne.com