3173 WITHSTANDING VOLTAGE HiTESTER

3173 PORTABLE WITHSTANDING VOLTAGE HiTESTER
Safety Standards
Measuring Instruments
Simple design with a selected set of functions
Setting range: 1 to 99 seconds
(1-second resolution)
Standard equipped with external I/O
3931 HIGH VOLTAGE CONTACT CHECKER
http://www.hioki.co.jp/
HIOKI company overview, new products, environmental considerations and
other information are available on our website.
(optional, soon to be released)
During voltage withstand testing, an erroneous pass
result is returned in the event of test lead discontinuity
or bad connection. The 3931 can verify connection of
measurement leads to assure reliable testing.
Selected set of functions in a portable unit
External I/O
The 3173 comes equipped with a timer function and external
I/O as standard in a handy portable unit, and can perform
voltage withstand testing up to 3 kV AC and 10 mA. Further,
the unit features a safe design that complies with EN61010-1
safety standards.
Input signal: START (active LOW)
STOP (active LOW)
Output signal: PASS (relay contact)
FAIL (relay contact)
TEST (open collector)
Adjustable range of output
voltage: 0 to 3 kV AC
Test result display: LED
Current threshold setting range: 0.1 to 9.9 mA
Timer setting range: 1 to 99 sec
Timer ON/OFF
■ Basic Specifications
■ General Specifications
[ Voltage generator ]
Operating temperature
range
Storage temperature
range
Temperature range for
guaranteed accuracy
Operating environment
Power supply
Output voltage range
Voltage application method
Transformer capacity
Voltage adjustment method
Voltage meter
Accuracy
Waveform
Frequency
: 0 to 3 kV AC (single range)
: Zero power switch
: 30 VA
: Manual adjustment
: Analog voltage meter, 0 to 3 kV AC (full scale)
: ±5% f.s.
: Power waveform
: Synchronized to power
[ Current detector ]
: 0.1 to 9.9 mA, resolution of 0.1 mA with
digital switching
: Setting value ± (5%+0.05mA)
: Using an analog comparator
: PASS: when testing stops because the current
being measured falls below the selected current
cut-off value (when using timer shut-off)
FAIL: when the current being measured is the
same or greater than the selected current cutoff value
Evaluation process : Outputs a buzzer sound and external I/O for
each evaluation result
Current cut-off
setting range
Current cut-off accuracy
Evaluation method
Evaluation content
[ Interface ] (rear panel)
EXT I/O input signal : START and STOP for external control
EXT I/O output signal : PASS and FAIL (contact make method using
relay contact)
TEST (open collector output)
[ Timer area ]
Setting range
Timer accuracy
: -10 to 50˚C, 90% rh or less (non-condensating)
: 23 ± 5˚C, 80% rh or less (non-condensating)
After a 10-minute warm-up period
: Indoors, up to 2000 m ASL
: 100 V AC (3173)
120 V AC (3173-01), 220 V AC (3173-02)
230 V AC (3173-03), 240 V AC (3173-04)
Power frequency : 50/60 Hz
Maximum rated power : 50 VA (common to all voltages)
Withstand voltage : Between power supply and chassis;
1.35 kV AC, 10 mA, 1 minute
: Approx. 149 (W) x 200 (H) x 215 (D) mm
Dimensions
: Approx. 6.3 kg (for 100 V AC)
Mass
Approx. 7.0 kg (for 120 to 240 V AC)
: 100 to 120 V AC (250 V T1AL)
Operating fuse
220 to 240 V AC (250 V T0.5AL)
Supplied accessories : Power cord, spare fuse,
1 x 9615-01 H.V. TEST LEAD (red - high voltage side),
1 x 9615-02 H.V. TEST LEAD lead (black - return side)
Conforming standards : EMC: EN61326-1:1997+A1:1998 CLASS A
EN61000-3-2:1995+A14:2000
EN61000-3-3:1995
Safety: EN61010-1:1993+A2:1995
Power area: Pollution level 2, overvoltage category
(the expected transient overvoltage is 2500 V),
Input area: Pollution level 2, overvoltage category,
EN61010-2-031:1994
: 1 to 99 sec (1-second resolution) or continuous
(timer OFF)
: Setting value ± (1%+50msec)
3173
PORTABLE WITHSTANDING VOLTAGE HiTESTER (100 V AC)
3173-01 PORTABLE WITHSTANDING VOLTAGE HiTESTER (120 V AC)
3173-02 PORTABLE WITHSTANDING VOLTAGE HiTESTER (220 V AC)
: 0 to 40˚C, 80% rh or less (non-condensating)
9615-01 H.V. TEST LEAD (red - high voltage side)
9615-02 H.V. TEST LEAD (black - return side)
Lead length: 1.5 m
3173-03 PORTABLE WITHSTANDING VOLTAGE HiTESTER (230 V AC)
3173-04 PORTABLE WITHSTANDING VOLTAGE HiTESTER (240 V AC)
DISTRIBUTED BY
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: os-com@ hioki.co.jp
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: hioki@ hiokiusa.com
Europe Representative Office :
Meineckestrasse 48, 40474 Dusseldorf, Germany
TEL / FAX +49-211-4544153
E-mail: hioki-eu@ doitsu.de
Shanghai Representative Office :
1108 Union Building, 100 Yan An Road (East),
Shanghai, 200002, P.R.China
TEL +86-21-6328-9947/4938
FAX +86-21-6328-2064
E-mail: [email protected]
All information correct as of Jun. 26, 2002. All specifications are subject to change without notice.
3173E1-26E-20P