INDEPENDENT TEST LABORATORY REPORT No. 30398

Lighting Sciences, Inc.
UL Verification Services
7826 E. Evans Rd.
Scottsdale, Arizona 85260 USA
P: 480-991-9260 F: 480-991-0375
[email protected]
www.lightingsciences.com
INDEPENDENT TEST LABORATORY REPORT No. 30398
Description:
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB5C4M
WITH SPECULAR REFLECTORS AND SEMI FROSTED CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10838 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
The sample(s) was(were) tested in accordance with the following applied
standards/regulations:
IES LM-41-98: Approved Method for Photometric Testing of Indoor Fluorescent Luminaire
(withdrawn)
IES LM-79-08: Approved Method for the Electrical and Photometric Measurements of
Solid-State Lighting Products
Accreditation: Lighting Sciences is ISO/IEC 17025 accredited by the International
Accreditation Service (IAS). The standards used in this test report are in Lighting
Sciences’ Scope of Accreditation.
Prepared for:
Approved by:
DIALIGHT
JIM DOMIGAN
FARMINGDALE, NJ
SR. TEST ENGINEER
MAR 26, 2012
This report shall not be reproduced except in full without the written approval of the laboratory. The results in this
report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to
indicate applicability to other similar products.
Page 1 of 8
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30398
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB5C4M
WITH SPECULAR REFLECTORS AND SEMI FROSTED CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10838 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
INTENSITY(CANDLEPOWER) SUMMARY
ANGLE
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
MEAN CP
4152
4135
4090
4012
3904
3779
3618
3390
3078
2682
2371
1869
1437
1089
775
485
249
70
0
LUMENS
399
1131
1740
2109
2076
1683
1081
521
98
ZONAL LUMENS AND PERCENTAGES
ZONE
0-30
0-40
0-60
0-90
40-90
60-90
90-180
0-180
LUMENS
3270
5379
9138
10838
5459
1700
0
10838
% LUMINAIRE
30.17
49.63
84.31
100.00
50.37
15.69
0.00
100.00
EFFICACY (LUMENS PER WATT):
74.2
*** THIS IS AN ABSOLUTE TEST ***
LUMINOUS LENGTH: 12.000 INS
WIDTH: 11.000 INS
11"
LUMINANCE SUMMARY CD./SQ.M.
ANGLE
45
55
65
75
85
S/MH:
SC:
MEAN CD/SQ M
44708
38409
30370
22074
9505
TESTED IN ACCORDANCE WITH IES PROCEDURES.
Page 2 of 8
1.3
1.3
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30398
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB5C4M
WITH SPECULAR REFLECTORS AND SEMI FROSTED CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10838 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
INTENSITY(CANDLEPOWER) DATA
IN 2.5 DEGREE STEPS
ANGLE
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
32.5
35.0
37.5
40.0
42.5
45.0
47.5
50.0
52.5
55.0
57.5
60.0
62.5
65.0
67.5
70.0
72.5
75.0
77.5
80.0
82.5
85.0
87.5
90.0
INTENSITY
LUMENS
(CANDLEPOWER)
4152
4147
4135
4116
4090
4056
4012
3960
3904
3845
3779
3705
3618
3513
3390
3246
3078
2887
2682
2489
2371
2142
1869
1640
1437
1256
1089
929
775
626
485
359
249
152
70
16
0
Page 3 of 8
399
1131
1740
2109
2076
1683
1081
521
98
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30398
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB5C4M
WITH SPECULAR REFLECTORS AND SEMI FROSTED CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10838 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
AVERAGE LUMINANCE DATA
CD./SQ.M
ANGLE
(FOOTLAMBERTS)
LUMINANCE
0
48750
(
14228)
30
49052
(
14316)
40
47183
(
13771)
45
44708
(
13048)
50
43311
(
12641)
55
38409
(
11210)
60
33750
(
9850)
65
30370
(
8863)
70
26620
(
7769)
75
22074
(
6442)
80
16846
(
4916)
85
9505
(
2774)
Page 4 of 8
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30398
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB5C4M
WITH SPECULAR REFLECTORS AND SEMI FROSTED CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10838 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CC
WALL
90
70
50
80
30
10
70
50
70
30
10
70
50
50
30
10
50
30
30
10
50
30
10
10
50
30
0
10
0
RCR
0 1.221.221.221.22 1.191.191.191.19 1.161.161.161.16 1.111.111.11 1.061.061.06 1.021.021.02 1.00
1 1.131.081.051.01 1.101.061.030.99 1.081.041.010.98 1.000.970.95 0.960.940.92 0.930.910.89 0.87
2 1.040.970.910.85 1.020.950.890.84 1.000.930.880.83 0.900.850.81 0.870.830.80 0.840.810.78 0.76
3 0.960.860.790.73 0.940.850.780.72 0.920.830.770.71 0.800.750.70 0.780.730.69 0.750.710.68 0.66
4 0.890.780.690.63 0.870.760.690.63 0.850.750.680.62 0.730.660.61 0.700.650.61 0.680.640.60 0.58
5 0.830.700.610.55 0.800.690.600.54 0.780.680.600.54 0.650.590.54 0.640.580.53 0.620.570.52 0.51
6 0.760.630.540.48 0.740.620.540.48 0.720.610.530.47 0.590.520.47 0.570.510.47 0.560.500.46 0.44
7 0.700.560.480.42 0.680.550.470.42 0.670.550.470.41 0.530.460.41 0.520.450.40 0.500.450.40 0.38
8 0.650.510.430.37 0.630.500.420.37 0.620.490.420.36 0.480.410.36 0.470.410.36 0.460.400.36 0.34
9 0.600.470.380.32 0.590.460.380.32 0.570.450.380.32 0.440.370.32 0.430.360.32 0.420.360.32 0.30
10 0.550.420.340.29 0.540.420.340.29 0.530.410.340.29 0.400.330.29 0.390.330.28 0.380.320.28 0.26
THE ABOVE COEFFICIENTS HAVE BEEN CALCULATED BASED ON LUMINAIRE LUMENS
BECAUSE IN AN ABSOLUTE TEST THE BARE LAMP LUMENS ARE UNKNOWN.
LIGHTING DESIGN CALCULATIONS MADE USING THESE COEFFICIENTS SHOULD
THEREFORE USE THE LUMINAIRE LUMENS IN THE CALCULATION FORMULA
LUMINAIRE INPUT WATTS 146.0
LABORATORY RESULTS MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE.
BALLAST AND FIELD FACTORS HAVE NOT BEEN APPLIED.
TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST
LUMINOUS OPENING OF LUMINAIRE.
Page 5 of 8
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30398
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB5C4M
WITH SPECULAR REFLECTORS AND SEMI FROSTED CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10838 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
ELECTRICAL MEASUREMENTS
INPUT VOLTAGE:
INPUT CURRENT:
INPUT POWER:
POWER FACTOR:
TOTAL HARMONIC DISTORTION:
OFF STATE POWER:
120.0
1.216
146.0
100.1
2.80
0.00
VOLTS AC
AMPS
WATTS
PERCENT
PERCENT
WATTS
INPUT VOLTAGE:
INPUT CURRENT:
INPUT POWER:
POWER FACTOR:
TOTAL HARMONIC DISTORTION:
277.0
0.537
140.2
94.2
7.88
VOLTS AC
AMPS
WATTS
PERCENT
PERCENT
10838
74.2
lm
lm/W
LIGHT OUTPUT
LUMENS:
EFFICACY:
SPECTRAL MEASUREMENTS
X:
y:
u/u':
v:
v':
Duv:
CRI(Ra):
0.3361
0.3373
0.2109
0.3174
0.4762
0.0034
76.1
CRI(R9):
CCT:
RADIANT FLUX:
5.6
5330
34734
Page 6 of 8
K
mW
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30398
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB5C4M
WITH SPECULAR REFLECTORS AND SEMI FROSTED CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10838 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
Tabulated Spectral Power Distribution
Wavelength
[nm]
[mW/nm]
380
390
400
410
420
430
440
450
460
470
480
490
500
510
520
530
540
550
560
570
580
0.58233
1.41736
2.82319
10.39392
44.12184
126.44161
268.70591
267.53750
118.76508
57.73307
38.15649
42.43125
69.07171
106.76268
138.41972
158.10942
169.48377
173.81924
175.68299
174.41601
170.77344
Wavelength
[nm]
[mW/nm]
590
600
610
620
630
640
650
660
670
680
690
700
710
720
730
740
750
760
770
780
164.85100
156.64041
145.21382
130.70558
114.02117
96.48376
79.61059
64.04126
50.47347
39.23225
30.15587
22.95082
17.44049
13.22088
9.97000
7.55330
5.70367
4.39199
3.33528
1.26436
Page 7 of 8
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30398
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB5C4M
WITH SPECULAR REFLECTORS AND SEMI FROSTED CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10838 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
LUMINOUS OPENING
SIDE VIEW
All testing was conducted in accordance with LM-79-08,
Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products as published
by the Illuminating Engineering Society of North America (IESNA).
The condition of the item tested was new.
Stabilization time before testing exceeded 16 hours.
The test results (luminous distribution and flux) were obtained by using a Lighting Sciences series
6000 Type C Moving Mirror Goniophotometer
•
The photometric reference standard used is a set of three incandescent luminous intensity
standard lamps calibrated and traceable to the U.S. National Institute of Standards and
Technology.
The test results (colorimetric
Integrating Sphere of either 1
geometry was used. Correction
spectroradiometer employed was
and luminous flux) were obtained by using a Lighting Sciences model 4000
or 2 meters diameter, having an internal reflectance exceeding 0.80. 4π
factors were applied for spectral mismatch and self-absorption. The
a LSC model 500E having a bandwidth of .84.
•
The photometric reference standard used is a set of three incandescent luminous flux standard
lamps calibrated and traceable to the U.S. National Institute of Standards and Technology.
•
The colorimetric reference standard used is an incandescent spectral standard lamp calibrated
and traceable to the U.S. National Institute of Standards and Technology.
Power measurements were obtained with a Yokogawa WT210 power analyzer.
Ambient temperature during testing was 25° C ± 1° C, measured using an Omega model DP460.
Calibration certificates are on file at the laboratories of Lighting Sciences Inc.
The results in this report apply to the test sample(s) mentioned in this report at the time of
the testing period only and are not to be used to indicate applicability to other similar
products.
Page 8 of 8