INDEPENDENT TEST LABORATORY REPORT No. 30394

Lighting Sciences, Inc.
UL Verification Services
7826 E. Evans Rd.
Scottsdale, Arizona 85260 USA
P: 480-991-9260 F: 480-991-0375
[email protected]
www.lightingsciences.com
INDEPENDENT TEST LABORATORY REPORT No. 30394
Description:
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB2C4M
WITH SPECULAR REFLECTORS AND CLEAR CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10817 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
The sample(s) was(were) tested in accordance with the following applied
standards/regulations:
IES LM-41-98: Approved Method for Photometric Testing of Indoor Fluorescent Luminaire
(withdrawn)
IES LM-79-08: Approved Method for the Electrical and Photometric Measurements of
Solid-State Lighting Products
Accreditation: Lighting Sciences is ISO/IEC 17025 accredited by the International
Accreditation Service (IAS). The standards used in this test report are in Lighting
Sciences’ Scope of Accreditation.
Prepared for:
Approved by:
DIALIGHT
JIM DOMIGAN
FARMINGDALE, NJ
SR. TEST ENGINEER
MAR 26, 2012
This report shall not be reproduced except in full without the written approval of the laboratory. The results in this
report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to
indicate applicability to other similar products.
Page 1 of 8
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30394
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB2C4M
WITH SPECULAR REFLECTORS AND CLEAR CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10817 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
INTENSITY(CANDLEPOWER) SUMMARY
ANGLE
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
MEAN CP
3926
3917
3891
3828
3728
3650
3580
3520
3379
3003
2585
2066
1593
1082
522
199
66
20
0
LUMENS
379
1078
1686
2197
2297
1852
1057
245
26
ZONAL LUMENS AND PERCENTAGES
ZONE
0-30
0-40
0-60
0-90
40-90
60-90
90-180
0-180
LUMENS
3143
5340
9489
10817
5478
1328
0
10817
% LUMINAIRE
29.06
49.36
87.72
100.00
50.64
12.28
0.00
100.00
EFFICACY (LUMENS PER WATT):
74.1
*** THIS IS AN ABSOLUTE TEST ***
LUMINOUS LENGTH: 12.000 INS
WIDTH: 11.000 INS
11"
LUMINANCE SUMMARY CD./SQ.M.
ANGLE
45
55
65
75
85
S/MH:
SC:
MEAN CD/SQ M
50060
42464
30174
9059
2692
TESTED IN ACCORDANCE WITH IES PROCEDURES.
Page 2 of 8
1.4
1.4
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30394
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB2C4M
WITH SPECULAR REFLECTORS AND CLEAR CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10817 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
INTENSITY(CANDLEPOWER) DATA
IN 2.5 DEGREE STEPS
ANGLE
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
32.5
35.0
37.5
40.0
42.5
45.0
47.5
50.0
52.5
55.0
57.5
60.0
62.5
65.0
67.5
70.0
72.5
75.0
77.5
80.0
82.5
85.0
87.5
90.0
INTENSITY
LUMENS
(CANDLEPOWER)
3926
3925
3917
3907
3891
3863
3828
3779
3728
3686
3650
3618
3580
3548
3520
3472
3379
3227
3003
2723
2585
2332
2066
1824
1593
1354
1082
802
522
330
199
113
66
39
20
5
0
Page 3 of 8
379
1078
1686
2197
2297
1852
1057
245
26
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30394
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB2C4M
WITH SPECULAR REFLECTORS AND CLEAR CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10817 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
AVERAGE LUMINANCE DATA
CD./SQ.M
ANGLE
(FOOTLAMBERTS)
LUMINANCE
0
46099
(
13454)
30
48537
(
14166)
40
51791
(
15116)
45
50060
(
14610)
50
47216
(
13780)
55
42464
(
12393)
60
37412
(
10919)
65
30174
(
8806)
70
17932
(
5233)
75
9059
(
2644)
80
4482
(
1308)
85
2692
(
785)
Page 4 of 8
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30394
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB2C4M
WITH SPECULAR REFLECTORS AND CLEAR CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10817 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CC
WALL
90
70
50
80
30
10
70
50
70
30
10
70
50
50
30
10
50
30
30
10
50
30
10
10
50
30
0
10
0
RCR
0 1.221.221.221.22 1.191.191.191.19 1.161.161.161.16 1.111.111.11 1.061.061.06 1.021.021.02 1.00
1 1.141.091.061.02 1.111.071.041.01 1.081.051.020.99 1.010.980.96 0.970.950.93 0.930.920.90 0.88
2 1.050.980.920.87 1.030.960.910.86 1.010.940.890.85 0.910.870.83 0.880.840.81 0.850.820.80 0.78
3 0.970.870.800.74 0.950.860.790.74 0.930.840.780.73 0.820.760.72 0.790.750.71 0.770.730.69 0.67
4 0.900.790.700.64 0.880.770.700.64 0.860.760.690.63 0.740.680.63 0.710.660.62 0.690.650.61 0.59
5 0.830.710.620.56 0.810.690.610.55 0.790.680.610.55 0.660.590.55 0.640.580.54 0.630.580.53 0.51
6 0.760.630.540.49 0.740.620.540.48 0.730.610.530.48 0.590.530.47 0.580.520.47 0.560.510.46 0.45
7 0.700.560.480.42 0.680.550.470.42 0.670.550.470.41 0.530.460.41 0.520.450.40 0.500.450.40 0.38
8 0.650.510.430.37 0.630.500.420.36 0.620.490.420.36 0.480.410.36 0.470.400.36 0.460.400.36 0.34
9 0.600.460.380.32 0.580.450.370.32 0.570.450.370.32 0.430.360.32 0.420.360.31 0.410.350.31 0.29
10 0.550.420.330.28 0.540.410.330.28 0.530.400.330.28 0.390.330.28 0.390.320.28 0.380.320.27 0.26
THE ABOVE COEFFICIENTS HAVE BEEN CALCULATED BASED ON LUMINAIRE LUMENS
BECAUSE IN AN ABSOLUTE TEST THE BARE LAMP LUMENS ARE UNKNOWN.
LIGHTING DESIGN CALCULATIONS MADE USING THESE COEFFICIENTS SHOULD
THEREFORE USE THE LUMINAIRE LUMENS IN THE CALCULATION FORMULA
LUMINAIRE INPUT WATTS 146.0
LABORATORY RESULTS MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE.
BALLAST AND FIELD FACTORS HAVE NOT BEEN APPLIED.
TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST
LUMINOUS OPENING OF LUMINAIRE.
Page 5 of 8
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30394
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB2C4M
WITH SPECULAR REFLECTORS AND CLEAR CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10817 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
ELECTRICAL MEASUREMENTS
INPUT VOLTAGE:
INPUT CURRENT:
INPUT POWER:
POWER FACTOR:
TOTAL HARMONIC DISTORTION:
OFF STATE POWER:
120.0
1.218
146.0
99.9
3.05
0.00
VOLTS AC
AMPS
WATTS
PERCENT
PERCENT
WATTS
INPUT VOLTAGE:
INPUT CURRENT:
INPUT POWER:
POWER FACTOR:
TOTAL HARMONIC DISTORTION:
277.0
0.545
143.0
94.8
8.16
VOLTS AC
AMPS
WATTS
PERCENT
PERCENT
10817
74.1
lm
lm/W
LIGHT OUTPUT
LUMENS:
EFFICACY:
SPECTRAL MEASUREMENTS
X:
y:
u/u':
v:
v':
Duv:
CRI(Ra):
0.3349
0.3357
0.2107
0.3168
0.4752
0.0037
76.3
CRI(R9):
CCT:
RADIANT FLUX:
6.2
5380
34753
Page 6 of 8
K
mW
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30394
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB2C4M
WITH SPECULAR REFLECTORS AND CLEAR CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10817 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
Tabulated Spectral Power Distribution
Wavelength
[nm]
[mW/nm]
380
390
400
410
420
430
440
450
460
470
480
490
500
510
520
530
540
550
560
570
580
0.62371
1.47933
2.79965
10.65700
45.79020
129.55507
268.91664
271.20306
120.53792
58.80763
38.77302
42.85095
69.34151
106.92064
138.43233
158.10241
169.10653
173.24308
174.97321
173.74077
170.35987
Wavelength
[nm]
[mW/nm]
590
600
610
620
630
640
650
660
670
680
690
700
710
720
730
740
750
760
770
780
164.59771
156.28891
144.73254
130.24771
113.50313
95.86664
78.72931
62.94343
49.35795
38.33091
29.52838
22.53233
17.08815
13.01514
9.77323
7.42160
5.63949
4.38550
3.38853
1.32540
Page 7 of 8
LIGHTING SCIENCES, INC.
7826 E. EVANS RD.
SCOTTSDALE, AZ, USA 85260
INDEPENDENT TEST LABORATORY REPORT No. 30394
DIALIGHT - LED HIGH BAY LUMINAIRE,CAT# HB2C4M
WITH SPECULAR REFLECTORS AND CLEAR CURVED PLASTIC LENS
EIGHTY FOUR LEDS. LUMINAIRE OUTPUT = 10817 LM
LUMINAIRE OPERATING AT 120 VAC AND 146 WATTS
LUMINOUS OPENING
SIDE VIEW
All testing was conducted in accordance with LM-79-08,
Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products as published
by the Illuminating Engineering Society of North America (IESNA).
The condition of the item tested was new.
Stabilization time before testing exceeded 16 hours.
The test results (luminous distribution and flux) were obtained by using a Lighting Sciences series
6000 Type C Moving Mirror Goniophotometer
•
The photometric reference standard used is a set of three incandescent luminous intensity
standard lamps calibrated and traceable to the U.S. National Institute of Standards and
Technology.
The test results (colorimetric
Integrating Sphere of either 1
geometry was used. Correction
spectroradiometer employed was
and luminous flux) were obtained by using a Lighting Sciences model 4000
or 2 meters diameter, having an internal reflectance exceeding 0.80. 4π
factors were applied for spectral mismatch and self-absorption. The
a LSC model 500E having a bandwidth of .84.
•
The photometric reference standard used is a set of three incandescent luminous flux standard
lamps calibrated and traceable to the U.S. National Institute of Standards and Technology.
•
The colorimetric reference standard used is an incandescent spectral standard lamp calibrated
and traceable to the U.S. National Institute of Standards and Technology.
Power measurements were obtained with a Yokogawa WT210 power analyzer.
Ambient temperature during testing was 25° C ± 1° C, measured using an Omega model DP460.
Calibration certificates are on file at the laboratories of Lighting Sciences Inc.
The results in this report apply to the test sample(s) mentioned in this report at the time of
the testing period only and are not to be used to indicate applicability to other similar
products.
Page 8 of 8