Appendix DEMKO CERTIFICATE

DEMKO CERTIFICATE
Certificate No.
Page
Date of Issue
D-04274
1/10
2015-06-17
Certificate Holder
Everlight Electronics Co., Ltd.
No.6-8, Zhonghua Rd., Shulin Dist., New Taipei City
23860 Taiwan
Manufacturer
Everlight Electronics Co., Ltd.
No.6-8, Zhonghua Rd., Shulin Dist., New Taipei City
23860 Taiwan
Production site
Certified Product
Model
Trademark
Rated Voltage / Frequency
Rated Current / Power
Insulation Class
Degree of protection (IP)
Tested acc. to
Test Report No.
Additional
Expire date
Certification Manager
Jan-Erik Storgaard
Certification Body
Everlight Electronics (China) Co., Ltd.
No. 2135 Zhong Shan North Rd. Wujiang Economy
Development Zone (Yun Xi Area), Songling Town,
Wujiang City, Jiang Su China
Optocouplers
See Page 2 to Page 9
EVERLIGHT
250Vrms
EN 60065:2002/A11:2008, EN 60065:2002/A12:2011,
EN 60065:2002/A1:2006, EN 60065:2002/A2:2010,
EN 60065:2002, EN 60950-1:2006/A11:2009,
EN 60950-1:2006/A12:2011, EN 60950-1:2006/A1:2010,
EN 60950-1:2006/A2:2013, EN 60950-1:2006,
EN 61347-1:2008/A1:2011, EN 61347-1:2008/A2:2013
EN 61347-1:2008, EN 60335-1:2012/A11:2014,
EN 60335-1:2012, EN 62368-1:2014
P15219385 issued on 2015-02-09
This is to replace previous certificate No. D-03294 issued on
2014-04-24, D-03295-M1 issued on 2014-04-30, D-03296 issued on
2014-04-24 and D-03301-M1 issued on 2014-04-30 due to new test
report has been issued
2025-06-16
This is to certify that representative sample(s) of the Product described herein (“Certified Product”) have been
investigated and found in compliance with the Standard(s) indicated on this Certificate, in accordance with the D
Mark Requirements. The Designated Certificate holder is entitled to use the δ or for cables <DEMKO>
> for the
Certified Product manufactured at the production site(s) identified above, in accordance with the D Mark Service
Agreement, including without limitation the D Mark Testing and Certification Services Service Terms. Only those
Products bearing the D Mark should be considered as being covered by UL’s D Mark Service. This Certificate shall
remain valid through the expiration date, unless terminated earlier in accordance with the Service Agreement
including without limitation if the Standard identified on this Certificate is amended or withdrawn prior the expiration
date.
UL International Demko A/S, Borupvang 5A, DK-2750
Ballerup, Denmark, Tel. +45 44 85 65 65, [email protected]
www.ul-europe.com
Appendix DEMKO CERTIFICATE
Certificate No.
Page
Date of Issue
D-04274
2/10
2015-06-17
Model / Type Ref.
EL817./EL816./EL819./EL829./EL826./EL827./
EL717./4N25./4N26./4N27./4N28./4N35./4N36./4N37./4N38./MCT2./MCT2E./
MCT210./CNY17-1./CNY17-2./CNY17-3./CNY17-4./MOC8111./MOC8112./
MOC8113./H11A1./H11A2./H11A3./H11A4./H11A5./TIL111./TIL117/CNX35U.
Optocoupler. Minimum external creepage distance is measured to 7.7mm,
minimum internal creepage distance is measured to 6.0mm and minimum
distance through insulation is measured to 0.5mm. Tested for reinforced
insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in 110 degree C, 1h
in 25 degree C, 2h in 0 degree C and 1h in 25 degree C. After the cycling test
a humidity test for 48h in 93% relative humidity. Electric strength test between
input and output 4800Vac/1 minute. The symbol "." in type designation may be
blank, A~Z or numbers, and denote different pin shape. Maximum operating
temperature: 110ºC.Tested for 5000m.
Model / Type Ref.
EL451./EL452.
Optocoupler. Minimum external creepage distance is measured to 5.0mm,
minimum internal creepage distance is measured to 4.0mm and minimum
distance through insulation is measured to 0.4mm. Tested for reinforced
insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in 110 degree
C, 1h in 25 degree C, 2h in 0 degree C and 1h in 25 degree C. After the
cycling test a humidity test for 48h in 93% relative humidity. Electric strength
test between input and output 4800Vac/1 minute. The symbol “.” in type
designation may be blank, A~Z or numbers, and denote different pin shape.
Maximum operating temperature: 110°C. The symbol “X” in type denotes X
= Part no. (0,1,2,3,4).
Model / Type Ref.
ELD3H5./ ELD3H6./ ELD3H7./ ELD3H4./ ELQ3H4./ ELQ3H5./ ELQ3H7./ ELM314.
Optocoupler. Minimum external creepage distance is measured to 5.0mm,
minimum internal creepage distance is measured to 4.0mm and minimum
distance through insulation is measured to 0.4mm. Tested for reinforced
insulation. Maximum operating temperature: 110°C. Thermal cycling test, 10
cycles. Each cycle: 68h in 110 degree C, 1h in 25 degree C, 2h in 0 degree
C and 1h in 25 degree C. After the cycling test a humidity test for 48h in 93%
relative humidity. Electric strength test between input and output 4800Vac/1
minute. The symbol "." in type designation may be blank, A~Z or numbers,
and denote different pin shape.
Certification Body
UL International Demko A/S, Borupvang 5A, DK-2750
Ballerup, Denmark, Tel. +45 44 85 65 65, [email protected]
www.ul-europe.com
Appendix DEMKO CERTIFICATE
Certificate No.
Page
Date of Issue
D-04274
3/10
2015-06-17
Model / Type Ref.
ELM452./ ELM453./ ELM600./ ELM601./ ELM611./ ELM452L./ ELM453L./
ELM600L./ ELM601L./ ELM611L./ELM454.
High Speed Optocoupler. Minimum external creepage distance is measured
to 5.0mm, minimum internal creepage distance is measured to 4.0mm and
minimum distance through insulation is measured to 0.4mm. Tested for
reinforced insulation. Maximum operating temperature: 100°C. Thermal
cycling test, 10 cycles. Each cycle: 68h in 100 degree C, 1h in 25 degree
C, 2h in 0 degree C and 1h in 25 degree C. After the cycling test a humidity
test for 48h in 93% relative humidity. Electric strength test between input and
output 4800Vac/1 minute. The symbol "." in type designation may be blank,
A~Z or numbers, and denote different pin shape.
Model / Type Ref.
ELD851./ELD852./4N29./4N30./4N31./4N32./4N33./H11B1./H11B2./H11B3./
H11B255./TIL113./MOC119./MOC8020./MOC8021./MOC8030./MOC8050./
MOC8080./EL301X./EL302X./EL305X./EL307X./EL303X./EL304X./EL306X./
EL308X./EL3161./EL3162./EL3163./H11L1./H11L2.
Optocoupler. Minimum external creepage distance is measured to 7.7mm,
minimum internal creepage distance is measured to 5.5mm and minimum
distance through insulation is measured to 0.5mm.Tested for reinforced
insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in 100 degree
C, 1h in 25degree C, 2h in 0 degree C and 1h in 25 degree C. After the
cycling test a humidity test for 48h in 93% relative humidity. Electric strength
test between input and output 4800Vac/1 minute. The symbol “.” in type
designation may be blank, A~Z or numbers, and denote different pin shape.
Maximum operating temperature: 100°C. The symbol “X” in type denotes X
= Part no. (0,1,2,3,4).
Model / Type Ref.
ELR3602./ELR3603./ELR2602./ELR2603./ELR1602./ELR1603./ELR3502./
ELR3503./ELR2502./ELR2503./ELR1502./ELR1503.
Power Triac Optocoupler. Minimum external creepage distance is measured
to 8.2mm, minimum internal creepage distance is measured to 5.1mm and
minimum distance through insulation is measured to 0.5mm. Tested for
reinforced insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in
100 degree C, 1h in 25degree C, 2h in 0 degree C and 1h in 25 degree C.
After the cycling test a humidity test for 48h in 93% relative humidity. Electric
strength tests, between input and output 4800Vac/1 minute. The symbol “.”
in type designation may be blank, A~Z or numbers, and denote different pin
shape. Maximum operating temperature: 100°C
Certification Body
UL International Demko A/S, Borupvang 5A, DK-2750
Ballerup, Denmark, Tel. +45 44 85 65 65,
[email protected]
www.ul-europe.com
Appendix DEMKO CERTIFICATE
Certificate No.
Page
Date of Issue
D-04274
4/10
2015-06-17
Model / Type Ref.
EL2801./EL354./EL355./EL356./EL357./EL359./EL121./EL124./EL2701./
EL2705./EL357N./EL356N./EL121N./EL124N./EL2701N./EL354N./
EL2705N./EL3H7./EL281./EL3H4./EL280./EL3H71./ELM301X./ELM302X./
ELM305X./ELM307X./ELM303X./ELM304X./ELM306X./ELM308X.
Optocoupler. Minimum external creepage distance is measured to 5.0mm,
minimum internal creepage distance is measured to 4.0mm and minimum
distance through insulation is measured to 0.4mm. Tested for reinforced
insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in 110 degree
C, 1h in 25 degree C, 2h in 0 degree C and 1h in 25 degree C. After the
cycling test a humidity test for 48h in 93% relative humidity. Electric strength
test between input and output 4800Vac/1 minute. The symbol “.” in type
designation may be blank, A~Z or numbers, and denote different pin shape.
Maximum operating temperature: 110°C. The symbol “X” in type denotes X
= Part no. (0,1,2,3,4).
Model / Type Ref.
EL847./EL844./EL845.
Optocoupler. Minimum external creepage distance is measured to 8.0mm,
minimum internal creepage distance is measured to 5.1mm and minimum
distance through insulation is measured to 0.5mm. Tested for reinforced
insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in 110 degree
C, 1h in 25 degree C, 2h in 0 degree C and 1h in 25 degree C. After the
cycling test a humidity test for 48h in 93% relative humidity. Electric strength
tests, between input and output 4800Vac/1 minute. The symbol "." in type
designation may be A to Z, numbers or blank, denote different pin shape.
Maximum operating temperature: 110°C
Model / Type Ref.
EL815./ EL814./EL824./ EL825.
Optocoupler. Minimum external creepage distance is measured to 7.9mm,
minimum internal creepage distance is measured to 6.0mm and minimum
distance through insulation is measured to 0.5mm. Tested for reinforced
insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in 110 degree
C, 1h in 25degree C, 2h in 0 degree C and 1h in 25 degree C. After the
cycling test a humidity test for 48h in 93% relative humidity. Electric strength
test between input and output 4800Vac/1 minute. The symbol “.” in type
designation may be blank, A~Z or numbers, and denote different pin shape.
Maximum operating temperature: 110º
Certification Body
UL International Demko A/S, Borupvang 5A, DK-2750
Ballerup, Denmark, Tel. +45 44 85 65 65,
[email protected]
www.ul-europe.com
Appendix DEMKO CERTIFICATE
Certificate No.
Page
Date of Issue
D-04274
5/10
2015-06-17
Model / Type Ref.
EL101X./ EL357L./ EL355L./ EL354L./ EL111X./ EL161X./ EL151X.
Optocoupler. Minimum external creepage distance is measured to 8.1mm,
minimum internal creepage distance is measured to 5.2mm and minimum
distance through insulation is measured to 0.4mm. Tested for reinforced
insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in 110 degree
C, 1h in 25degree C, 2h in 0 degree C and 1h in 25 degree C. After the
cycling test a humidity test for 48h in 93% relative humidity. Electric strength
test between input and output 4800Vac/1 minute. The symbol “.” in type
designation may be blank, A~Z or numbers, and denote different pin shape.
Maximum operating temperature: 110°C. The symbol “X” in type denotes X
= Part no. (0,1,2,3,4,5,6,7,8,9).Tested for 5000m.
Model / Type Ref.
EL205./EL206./EL207./EL208./EL211./EL212./EL213./EL215./EL216./
EL217./ELD207./ELD208./ELD213./ELD217./ELD205./ELD206./ELD211.
Optocoupler. Minimum external creepage distance is measured to 4.4mm,
minimum internal creepage distance is measured to 3.5mm and minimum
distance through insulation is measured to 0.4mm. Tested for basic and
supplementary insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in
110 degree C, 1h in 25 degree C, 2h in 0 degree C and 1h in 25 degree C.
After the cycling test a humidity test for 48h in 93% relative humidity. Electric
strength test between input and output 2400Vac/1 minute. The symbol “.” in
type designation may be blank, A~Z or numbers, and denote different pin
shape. Maximum operating temperature: 110°C
Model / Type Ref.
6N135./6N136./6N137./6N138./6N139./EL2502./EL250L./EL2503./EL4502./
EL4503./EL2530./EL253L./EL2531./EL4534./EL2730./EL2731./EL2601./
EL260L./EL2611./EL261A./EL261N./EL2630./EL263L./EL263A./EL263N./
EL2631./EL4661./EL4504.
High Speed Optocoupler. Minimum external creepage distance is measured
to 8.0mm, minimum internal creepage distance is measured to 5.0mm and
minimum distance through insulation is measured to 0.5mm.Tested for
reinforced insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in
100 degree C, 1h in 25 degree C, 2h in 0 degree C and 1h in 25 degree C.
After the cycling test a humidity test for 48h in 93% relative humidity. Electric
strength test between input and output 4800Vac/1 minute. The symbol “.” in
type designation may be blank, A~Z or numbers, and denote different pin
shape. Maximum operating temperature: 100°C.
Certification Body
UL International Demko A/S, Borupvang 5A, DK-2750
Ballerup, Denmark, Tel. +45 44 85 65 65,
[email protected]
www.ul-europe.com
Appendix DEMKO CERTIFICATE
Certificate No.
Page
Date of Issue
D-04274
6/10
2015-06-17
Model / Type Ref.
H11L3./H11D1./H11D2./H11D3./H11D4./H11G1./H11G2./EL371./
EL725./4N50./4N51./4N52./4N53./4N54./4N55./4N56./4N57./4N58./4N59./
EL852./EL851./H11G3.
Optocoupler. Minimum external creepage distance is measured to 7.7mm,
minimum internal creepage distance is measured to 5.5mm and minimum
distance through insulation is measured to 0.5mm.Tested for reinforced
insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in 100 degree
C, 1h in 25degree C, 2h in 0 degree C and 1h in 25 degree C. After the
cycling test a humidity test for 48h in 93% relative humidity. Electric strength
test between input and output 4800Vac/1 minute. The symbol “.” in type
designation may be blank, A~Z or numbers, and denote different pin shape.
Maximum operating temperature: 100°C. The symbol “X” in type denotes X
= Part no. (0,1,2,3,4).
Model / Type Ref.
EL0500./EL0501./EL0452./EL0453./EL0454./EL0600./EL0601./EL0611./
EL0700./EL050L./EL060L./EL0701./EL061A./EL061N./EL0551./EL0530./
EL0531./EL0533./EL063X./EL0661./EL0730./EL0731./EL053L.
High Speed Optocoupler . Minimum external creepage distance is measured
to 4.4mm, minimum internal creepage distance is measured to 3.5mm and
minimum distance through insulation is measured to 0.4mm. Tested for
basic and supplementary insulation. Thermal cycling test, 10 cycles. Each
cycle: 68h in 100 degree C, 1h in 25degree C, 2h in 0 degree C and 1h in
25 degree C. After the cycling test a humidity test for 48h in 93% relative
humidity. Electric strength test between input and output 2400Vac/1 minute.
The symbol “.” in type designation may be blank, A~Z or numbers, and
denote different pin shape. Maximum operating temperature: 100°C. The
symbol “X” in type denotes X = Part no. (0,1,L,A,N).
Model / Type Ref.
EL617./CNY75G./CQY80.G/K233.G/TCDT110.G/TCDT111.G/TCDT112.G/
HS817.G/TCET110.G/TCET111.G/ TCET120.G
Optocoupler. Minimum external creepage distance is measured to 8.0mm,
minimum internal creepage distance is measured to 6.0mm and minimum
distance through insulation is measured to 0.5mm. Tested for reinforced
insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in 110 degree
C, 1h in 25 degree C, 2h in 0 degree C and 1h in 25 degree C. After the
cycling test a humidity test for 48h in 93% relative humidity. Electric strength
test between input and output 4800Vac/1 minute. The symbol “.” in type
designation may be blank, A~Z or numbers, and denote different pin shape.
Maximum operating temperature: 110°C
Certification Body
UL International Demko A/S, Borupvang 5A, DK-2750
Ballerup, Denmark, Tel. +45 44 85 65 65,
[email protected]
www.ul-europe.com
Appendix DEMKO CERTIFICATE
Certificate No.
Page
Date of Issue
D-04274
7/10
2015-06-17
Model / Type Ref.
EL2200./EL2212./EL2231./EL2201./EL2202./EL2219./EL2211./ EL2232.
High Speed Optocoupler. Minimum external creepage distance is measured
to 8.2mm, minimum internal creepage distance is measured to 5.1mm and
minimum distance through insulation is measured to 0.5mm. Tested for
reinforced insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in
100 degree C, 1h in 25degree C, 2h in 0 degree C and 1h in 25 degree C.
After the cycling test a humidity test for 48h in 93% relative humidity. Electric
strength tests, between input and output 4800Vac/1 minute. The symbol “.”
in type designation may be blank, A~Z or numbers, and denote different pin
shape. Maximum operating temperature: 100°C
Model / Type Ref.
CNX36U./CNX38U./CNX39U./SL5500./SL5501./SL5504./SL5511./
MOC8100./MOC8101./MOC8102./MOC8103./MOC8104./MOC8105./
MOC8106./MOC8107./MOC8108./EL9001./CNY17F-1./CNY17F-2./
CNY17F-3./CNY17F-4./H11AA1./H11AA2./H11AA3./H11AA4./HS817./
K817P./TCET110.
Optocoupler. Minimum external creepage distance is measured to 7.7mm,
minimum internal creepage distance is measured to 6.0mm and minimum
distance through insulation is measured to 0.5mm. Tested for reinforced
insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in 110 degree
C, 1h in 25 degree C, 2h in 0 degree C and 1h in 25 degree C. After the
cycling test a humidity test for 48h in 93% relative humidity. Electric strength
test between input and output 4800Vac/1 minute. The symbol "." in type
designation may be blank, A~Z or numbers, and denote different pin shape.
Maximum operating temperature: 110ºC.Tested for 5000m.
Model / Type Ref.
TCET111./TCET120./VO610A./VO615A./CNY17G./CNY75./CQY80./K233./
TCDT110./TCDT111./TCDT112./EL2501./EL2561./EL8171./CNY171-1./
CNY171-2./CNY171-4./CNY17F1-1./CNY17F1-2./CNY17F1-3./CNY17F1-4./
EL610./CNY1713.
Optocoupler. Minimum external creepage distance is measured to 7.7mm,
minimum internal creepage distance is measured to 6.0mm and minimum
distance through insulation is measured to 0.5mm. Tested for reinforced
insulation. Thermal cycling test, 10 cycles. Each cycle: 68h in 110 degree
C, 1h in 25 degree C, 2h in 0 degree C and 1h in 25 degree C. After the
cycling test a humidity test for 48h in 93% relative humidity. Electric strength
test between input and output 4800Vac/1 minute. The symbol "." in type
designation may be blank, A~Z or numbers, and denote different pin shape.
Maximum operating temperature: 110ºC.Tested for 5000m.
Certification Body
UL International Demko A/S, Borupvang 5A, DK-2750
Ballerup, Denmark, Tel. +45 44 85 65 65,
[email protected]
www.ul-europe.com
Appendix DEMKO CERTIFICATE
Certificate No.
Page
Date of Issue
D-04274
8/10
2015-06-17
Model / Type Ref.
EL806A./ EL810A./ EL820A./ EL825A./ EL835A./ EL840A./ EL860A./
EL406A./ EL410A./ EL420A./ EL425A./ EL435A./ EL440A./ EL460A./
EL606A./ EL610A./ EL620A./ EL625A./ EL635A./ EL640A./ EL660A.
Solid State Relay. Minimum external creepage distance is measured to
7.7mm, minimum internal creepage distance is measured to 6.0mm and
minimum distance through insulation is measured to 0.5mm. Tested for
reinforced insulation. Maximum operating temperature: 85ºC. Thermal
cycling test, 10 cycles. Each cycle: 68h in 85 degree C, 1h in 25 degree C,
2h in 0 degree C and 1h in 25 degree C. After the cycling test a humidity test
for 48h in 93% relative humidity. Electric strength test between input and
output 4800Vac/1 minute. The symbol "." in type designation may be blank,
A~Z or numbers, and denote different pin shape.
Model / Type Ref.
ELT301X./ ELT302X./ ELT305X./ ELT303X./ ELT304X./ ELT306X./
ELT308X./ ELT307X.
Triac Optocoupler. Minimum external creepage distance is measured to
7.7mm, minimum internal creepage distance is measured to 6.0mm and
minimum distance through insulation is measured to 0.5mm. Tested for
reinforced insulation. Maximum operating temperature: 110ºC. Thermal
cycling test, 10 cycles. Each cycle: 68h in 110 degree C, 1h in 25 degree
C, 2h in 0 degree C and 1h in 25 degree C. After the cycling test a humidity
test for 48h in 93% relative humidity. Electric strength test between input
and output 4800Vac/1 minute. The symbol “X” in type denotes X = Part
no. (0,1,2,3,4). The symbol "." in type designation may be blank, A~Z or
numbers, and denote different pin shape.
Model / Type Ref.
ELW137./ ELW139./ ELW2601./ ELW2611./ ELW136./ ELW135./
ELW4502./ ELW4503./ ELW138./ ELW260L./ ELW250L./ ELW4504.
High Speed Optocoupler. Minimum external creepage distance is measured
to 11.85mm, minimum internal creepage distance is measured to 7.72mm
and minimum distance through insulation is measured to 0.9mm. Tested
for reinforced insulation. Maximum operating temperature: 100°C. Thermal
cycling test, 10 cycles. Each cycle: 68h in 100 degree C, 1h in 25 degree
C, 2h in 0 degree C and 1h in 25 degree C. After the cycling test a humidity
test for 48h in 93% relative humidity. Electric strength test between input and
output 4800Vac/1 minute. The symbol "." in type designation may be blank,
A~Z or numbers, and denote different pin shape.
Certification Body
UL International Demko A/S, Borupvang 5A, DK-2750
Ballerup, Denmark, Tel. +45 44 85 65 65,
[email protected]
www.ul-europe.com
Appendix DEMKO CERTIFICATE
Certificate No.
Page
Date of Issue
D-04274
9/10
2015-06-17
Model / Type Ref.
EL3120./ EL3140./ EL3150./ EL3180./ EL3184.
IGBT Gate Drive Optocoupler. Minimum external creepage distance is
measured to 7.7mm, minimum internal creepage distance is measured to
6.0mm and minimum distance through insulation is measured to 0.5mm.
Tested for reinforced insulation. Maximum operating temperature: 110ºC.
Thermal cycling test, 10 cycles. Each cycle: 68h in 110 degree C, 1h in 25
degree C, 2h in 0 degree C and 1h in 25 degree C. After the cycling test a
humidity test for 48h in 93% relative humidity. Electric strength test between
input and output 4800Vac/1 minute. The symbol "." in type designation may
be blank, A~Z or numbers, and denote different pin shape.
Model / Type Ref.
ELW3120./ ELW3140./ ELW3150./ ELW3180./ ELW3184.
IGBT Gate Drive Optocoupler. Minimum external creepage distance is
measured to 11.85mm, minimum internal creepage distance is measured to
7.72mm and minimum distance through insulation is measured to 0.9mm.
Tested for reinforced insulation. Maximum operating temperature: 110°C.
Thermal cycling test, 10 cycles. Each cycle: 68h in 110 degree C, 1h in 25
degree C, 2h in 0 degree C and 1h in 25 degree C. After the cycling test a
humidity test for 48h in 93% relative humidity. Electric strength test between
input and output 4800Vac/1 minute. The symbol "." in type designation may
be blank, A~Z or numbers, and denote different pin shape.
External Certification Information:
The certificate has been issued on the basis of CB certificate No. P15219385, issued on 2015-02-09 by Nemko AS
Certification Body
UL International Demko A/S, Borupvang 5A, DK-2750
Ballerup, Denmark, Tel. +45 44 85 65 65,
[email protected]
www.ul-europe.com
Appendix DEMKO CERTIFICATE
Certificate No.
Page
Date of Issue
Certification Body
D-04274
10/10
2015-06-17
UL International Demko A/S, Borupvang 5A, DK-2750
Ballerup, Denmark, Tel. +45 44 85 65 65, [email protected]
www.ul-europe.com