View - Crydom

Single Channel SSRs
SRs
Dual Channel SSRs
SeriesOne DR
THE GLOBAL EXPERT
IN SOLID STATE RELAY
TECHNOLOGY
ABOUT US
Crydom, a company of Custom Sensors & Technologies (CST) and
global expert in Solid State Relay Technology, has a distinguished
record of providing high quality, world class Solid State Relay and
Control Products for a variety of heating, lighting and motion control
applications. Crydom products, coupled with unparalleled technical
support, timely delivery and competitive pricing, provide
Crydom’s clients with the innovative products and support necessary
to succeed in today’s competitive and fast paced global markets.
Crydom’s extensive selection of standard off-the-shelf products is
constantly being updated and expanded through its continuous
improvement and aggressive new product development programs.
Utilizing state of the art designs, materials and technology, Crydom
offers a wide range of AC and DC output SSRs in industry standard
Panel Mount, PCB Mount and DIN Rail packages, all meeting global
safety and standards agency requirements such as CE, RoHS, UL,
IEC, etc.
DIN RAIL MOUNTED
AC & DC OUTPUT
SOLID STATE RELAYS
SeriesOne DR Single & Dual Channel SSRs
Crydom’s SeriesOne DR Solid State Relays incorporate proprietary
thermal management technology resulting in exceptional output ratings
of 6 and 12 amps at 40 °C ambient in compact 11 and 18 mm wide DIN
rail mounted housings. Ideally suited for heating , lighting or motion
control applications where DIN rail space may be limited, the unique
design provides both greater power density than previously available in
DIN rail mounted Solid State Relays, and greater safety for personnel by
eliminating exposed hot metal surfaces typical of SSRs utilizing external
heat sinks to attain comparable ratings.
SeriesOne DR SSRs feature all solid state design with optical coupling,
AC or DC inputs with LED input status indicator, mounting to standard
35 mm DIN rail, RoHS compliance, CE certification, and UL/cUL
Bolstered by four decades of Solid State Relay operations experience,
Crydom also specializes and encourages adapted and fully
custom-designed SSR products for nearly any application where
unique specifications and optimized performance are critical for
recognition including General Use, Motor Controller and 100k cycle
endurance ratings.
SeriesOne DR Single Channel Outputs
SeriesOne DR Single Channel output SSRs incorporate either rugged
success.
SCRs for heavy AC industrial loads up to 600 VAC, or power FETs for
foot
superior performance with DC loads up to 100 VDC. Single channel
manufacturing facility houses all aspects of its ISO certified
models are available with output ratings of either 6 Amps at 40 °C in an
operation
Engineering,
11 mm package, or 12 Amps at 40 °C in an 18 mm wide package. AC
Manufacturing Operations and Quality Assurance, Customer Service,
output models also offer either zero voltage turn-on for resistive loads
Finance, Marketing and General Management, permitting close
or random turn-on for inductive loads. Both AC and DC control voltages
coordination of all aspects of Crydom’s activities.
are available.
Crydom’s
modern
including
purpose-built
Design
and
100,000
square
Development
Applications
Engineering and Sales support are both performed in the field to
provide Crydom’s Customers with the unparalleled technical and
commercial support.
SeriesOne DR Dual Channel Outputs
SeriesOne DR Dual Channel AC output SSRs also feature SCRs for
superior performance. The two independent channels are housed in an
Following rigid design guidelines and standards, Crydom products
have set the bench mark for SSR performance and reliability world
wide. In addition to award winning designs, Crydom has acquired an
18 mm package with output ratings up to 6 Amps rms per channel at 40
°C, 600 VAC, in zero voltage or random turn-on, and 4 to 32 VDC control
voltage.
impressive list of patents related to SSRs and Solid State Controls,
while continuing to develop new circuit and technology-related
inventions as part of extensive R&D programs.
For more information, technical support or questions about adapted
assemblies, contact your local Crydom Distributor or Regional Sales
office.
To learn more about Crydom SSR technology and products, or how an
alliance with Crydom can contribute to the success of your project,
visit www.crydom.com or contact your authorized Crydom
Distributor or Crydom Customer Service Representative today.
www.crydom.com
SeriesOne DR Single Channel
AC/DC Output
6 & 12 Amps output power rating
60 & 100 VDC, 24 to 600 VAC operating voltage ratings
4-32 VDC, 24, 120 & 230 VAC control input options available
IP20 housing with unique integrated heat sink design (Patent Pending)
AC Output versions with Zero Voltage Turn-On for resistive loads and Random Turn-On for
inductive loads
High power density for multiple units
UL & cUL approved including General Purpose and Motor Controller ratings
CE & RoHS compliant
OUTPUT SPECIFICATIONS (A)
DR06x06
DR10x06
DR24x06
DR48x06
DR06x12
DR10x12
DR24x12
DR48x12
Operating Voltage (47-63Hz AC Only)
General Use Current Rating (B) (Resistive Load)
UL Motor Controller Ratings @ 240 VAC [HP]
Min. Load Current
Max.Off-State Leakage Current @ Rated Voltage
Max. Surge Current [Apk] (Duration in ms)
Max. Surge Current [Apk] (Duration in ms)
Transient Overvoltage [Vpk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
On-State Resistence at rated load current [Ohm]
Max. I²t for Fusing (10/8.3 ms) [A²sec]
Min. Off-State dv/dt @ Max. Rated Voltage [V/μsec]
Maximum Turn-On Time (D)
Maximum Turn-Off Time (E)
Power Factor (Minimum) with Maximum Load
1-60 VDC
6 ADC
N/A
2.5 mA DC
0.1 mA DC
60 (10)
N/A
N/A
0.6
0.1
N/A
N/A
600 (μsec)
300 (μsec)
N/A
1-100 VDC
6 ADC
N/A
2.5 mA DC
0.1 mA DC
60 (10)
N/A
N/A
0.6
0.1
N/A
N/A
600 (μsec)
300 (μsec)
N/A
24-280 VAC
6 Arms
1/6
0.15 Arms
0.1 mArms
300 (16.6)
285 (20)
600
1.3
N/A
410/375
500
1/2 cycle
1/2 cycle
0.5
48-600 VAC
6 Arms
1/6
0.15 Arms
0.1 mArms
300 (16.6)
285 (20)
1200
1.3
N/A
410/375
500
1/2 cycle
1/2 cycle
0.5
1-60 VDC
12 ADC
N/A
2.5 mA DC
0.1 mA DC
100 (10)
N/A
N/A
0.5
0.045
N/A
N/A
1 (msec)
300 (μsec)
N/A
1-100 VDC
12 ADC
N/A
2.5 mA DC
0.1 mA DC
100 (10)
N/A
N/A
0.5
0.045
N/A
N/A
1 (msec)
300 (μsec)
N/A
24-280 VAC
12 Arms
1/3
0.15 Arms
0.1 mArms
750 (16.6)
715 (20)
600
1.3
N/A
2560/2330
500
1/2 cycle
1/2 cycle
0.5
48-600 VAC
12 Arms
1/3
0.15 Arms
0.2 mArms
750 (16.6)
715 (20)
1200
1.3
N/A
2560/2330
500
1/2 cycle
1/2 cycle
0.5
DRxxD06
DRxxE06
DRxxB06
DRxxA06
DRxxD12
DRxxE12
DRxxB12
DRxxA12
90-140 VAC
90 VAC
10 VAC
N/A
5 mA @ 120 VAC
200-265 VAC
200 VAC
90 VAC
N/A
3 mA @ 230 VAC
90-140 VAC
90 VAC
10 VAC
N/A
5 mA @ 120 VAC
200-265 VAC
200 VAC
90 VAC
N/A
3 mA @ 230 VAC
INPUT SPECIFICATIONS (A)
Control Voltage Range
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Reverse Polarity Protection
Typical Input Current
(C)
4-32 VDC
18-36 VAC
4 VDC
18 VAC
1 VDC
4 VAC
Yes
N/A
(F)
10 mA @ 24 VDC 6 mA @ 24 VAC
GENERAL SPECIFICATIONS (A)
Dielectric Strength, Input to Output. AC Output Versions (50/60Hz) [Vrms]
Dielectric Strength, Input to Output. DC Output Versions [Vrms]
Dielectric Strength, Input-Output to Case (50/60Hz) [Vrms]
Minimum Insulation Resistance (@ 500 VDC) [Ohm]
Maximum Capacitance, Input/Output [pF]
Ambient Operating Temperature Range [°C]
Ambient Storage Temperature Range [°C]
Weight (typical) [oz] (gr)
Housing Material
Input Terminal Wire Capacity
Output Terminal Wire Capacity
Maximum Recommended Terminal Screw Torque Input/Output [in/lbs] (Nm)
GENERAL NOTES
All parameters at 25°C unless otherwise specified.
Minimum spacing required between devices (see derating curves).
(C) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1.
(D) Turn-On time for Random-type AC Output is 0.1 ms for DC Control Models and
20 ms for AC Control Models.
(E) Turn-Off time for AC output versions with AC control is 30 ms.
(F) Input circuit incorporates active current limitation.
(G) Not all combinations of ratings are available.
4-32 VDC
18-36 VAC
4 VDC
18 VAC
1 VDC
4 VAC
Yes
N/A
(F)
10 mA @ 24 VDC 6mA @ 24 VAC
DRxxx06
DRxxx12
4000
2500
2500
109
10
-30 to 80
-30 to 125
3.17 (90)
UL 94 V0 Self-extinguishing
22 AWG minimum, 16 AWG maximum
22 AWG minimum, 14 AWG x 2 or 12 AWG x1 (standed/solid) maximum
4.4 (0.5) / 7.0 (0.8)
1.76 (50)
Part Number Nomenclature (G)
Max Output Voltage
(A)
(B)
Series
DR
06: 1 to 60 VDC
10: 1 to 100 VDC
24: 24 to 280 VAC
48: 48 to 600 VAC
24
D
Output Current
06: 6 Amps
12: 12 Amps
12
R
Control Voltage
Required for valid part number
For options only and not required
for valid part number
Other Crydom products and competitive part number cross-reference available at:
www.crydom.com
D: 4 to 32 VDC
A: 208 to 265 VAC
B: 90 to 140 VAC
E: 18 to 36 VAC
Options
AC
Output
Only
Blank: Zero Voltage Turn-On
R: Random Turn-On
(AC Output Only)
Wiring Diagrams (J)
Mechanical Dimensions
Tolerances: ± 0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
For DRxxx06 or DRxxx12 versions
FRONT VIEW
OL
2.88
[73,0]
2.02
[51,2]
2.02
[51,2]
.71
[18,0]
4/A2
.43
[11,0]
+3/A1
2.88
[73,0]
2
4/A
For DRxxx12 or DRDxxD06 versions
1
+3/A
For DRxxx06
R
NT
CO GE
C
A
A
/
DC VOLT
(H)
INPUT
STATUS
2/T1
1/L1
SIDE VIEW
d
For DRxxx06 or DRxxx12 versions
For DRDxxD06 versions
3.55
[90,3]
Loa
Y
L
PP
/AC
SU
DC
3.55
[90,3]
For DRDxxD06 versions
dA
Loa
3.32
[84,4]
3/B1
1/L1
2/A2
4/B2
2/A2
INPUT INPUT
STATUS STATUS
INPUT
STATUS
2.59
[65,9]
3.45
[87,6]
3.45
[87,6]
(J)
+A
-A
(H) +B
OL -B
3/B1
2.59
[65,9]
4/B2
1.77
[45,0]
INPUT
INPUT
STATUS STATUS
1.77
[45,0]
R
NT
DC
(H)
Y
PL
UP
S
AC
1/A1
4/A2
1/A1
2
2/A
3.3
[83,7]
2/T1
1
1/A
+3/A1
CO
dB
Y
PL
Loa
P
4 Pin connector for dual channel ouput only. Matting connector: MOLEX 050579404 or equivalent.
No grounding wire required. DC inductive loads must be diode suppressed.
AC
SU
Derating Curves
DRxxx12
12.0
Load Current (Amps)
Load Current (Amps)
DRDxxD06
Combined Load Current (Amps)
DRxxx06
6.0
5.0
4.0
3.0
2.0
1.0
0.0
10.0
8.0
6.0
4.0
2.0
0.0
0
10
20
30
40
50
60
70
80
0
Ambient Temperature (°C)
Installed Single Unit
Multiple Units (No Spacing)
Questions? Call or e-mail
Americas +1 (877) 502 5500 [email protected]
Europe +44 (0) 1202 606030 [email protected]
10
20
30
40
50
60
Ambient Temperature (°C)
70
80
12.0
10.0
8.0
6.0
4.0
2.0
0.0
0
10
20
30
40
50
60
Ambient Temperature (°C)
70
80
SeriesOne DR Dual Channel
AC Output
Two independent 6 Amp channels
DIN rail mount 18 mm wide package
4-32 VDC control input
24 to 600 VAC operating voltage ratings
IP20 housing with unique integrated heat sink design (Patent Pending)
AC Output versions with Zero Voltage Turn-On for resistive loads and Random Turn-On for inductive loads
High power density for multiple units
UL & cUL approved including General Purpose and Motor Controller ratings
CE & RoHS compliant
OUTPUT SPECIFICATIONS (A)
Operating Voltage (47-63Hz) [VAC]
General Use Current Rating (B) (Resistive Load)
UL Motor Controller Ratings @ 240 VAC [HP]
Minimum Load Current [Arms]
MaximumOff-State Leakage Current @ Rated Voltage [mArms]
Maximum Surge Current [Apk] @ 60 Hz (Duration in ms)
Maximum Surge Current [Apk] @ 50 Hz (Duration in ms)
Transient Overvoltage [Vpk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum I²t for Fusing (10/8.3 ms) [A²sec]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (C)
Maximum Turn-On Time (D)
Maximum Turn-Off Time
Power Factor (Minimum) with Maximum Load
DRD24D06
DRD48D06
24-280
6 Arms per channel
1/6
0.15
0.1
750 (16.6)
715 (20)
600
1.3
2560/2330
500
1/2 cycle
1/2 cycle
0.5
48-600
6 Arms per channel
1/6
0.15
0.2
750 (16.6)
715 (20)
1200
1.3
2560/2330
500
1/2 cycle
1/2 cycle
0.5
INPUT SPECIFICATIONS (A)
Control Voltage Range [VDC]
Min. Turn-On Voltage [VDC]
Min. Turn-Off Voltage [VDC]
Reverse Polarity Protection
Typical Input Current
GENERAL SPECIFICATIONS (A)
ID Marker Strips
CNLB, CNLN, CNL2
Packages of 10 plastic strips comprising
10 individual markers which can be
placed for easy identification during
the use of multiple units.
Blank Strips
Part no.: CNLB
DRDxxD06
4-32
4
1
Yes
10 mA @ 24 VDC (F)
Numbered 1 to 10 Strips
Part no.: CNLN
DRDxxD06
Dielectric Strength, Input to Output (50/60Hz) [Vrms]
2500
Dielectric Strength, Input-Output to Case (50/60Hz) [Vrms]
2500
Minimum Insulation Resistance (@ 500 VDC) [Ohm]
109
10
Maximum Capacitance, Input/Output [pF]
-30 to 80
Ambient Operating Temperature Range [°C]
-30 to 125
Ambient Storage Temperature Range [°C]
Weight (typical) [oz] (gr)
3.17 (90)
Housing Material
UL 94 V0 Self-extinguishing
Input Terminal Wire Capacity
22 AWG minimum, 16 AWG maximum
22 AWG minimum, 14 AW G x 2 or 12AW G x1 (standed/solid) maximum
Output Terminal W ire Capacity
4.4 (0.5) / 7.0 (0.8)
Maximum Recommended Terminal Screw Torque Input/Output [in/lbs] (Nm)
GENERAL NOTES
(A)
(B)
(C)
(D)
(F)
All parameters at 25°C unless otherwise specified.
Minimum spacing required between devices (see derating curves).
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1.
Turn-On time is 0.1 ms for Random-type DC Control Models.
Input circuit incorporates active current limitation.
Numbered 11 to 20 Strips
Part no.: CNL2
Part Number Nomenclature
Max Output Voltage
Series
DRD
Output Current
24: 24 to 280 VAC
48: 48 to 600 VAC
24
D
06: 6 Amps
06
Control Voltage
To view available Installation Sheet
scan the QR code with your
smartphone or visit www.crydom.com
Required for valid part number
For options only and not required
for valid part number
Other Crydom products and competitive part number cross-reference available at:
www.crydom.com
D: 4 to 32 VDC
R
Options
Blank: Zero Voltage Turn-On
R: Random Turn-On
AMERICAS
USA & CANADA
Crydom Inc
2320 Paseo de las Americas,
Suite 201
San Diego CA 92154
Sales Support
Tel.: +1 (877) 502 5500
Fax: +1 (619) 210 1590
[email protected]
Tech Support
Tel.: +1 (877) 702 7700
[email protected]
Across the Globe
MEXICO
Automatismo Crouzet
S.A. de C.V.
Calzada Zavaleta 2505 - C
Col Sta Cruz Buenavista
C.P. 72150 - Puebla
MEXICO
Tel.: +52 (222) 409 7000
Fax: +52 (222) 409 7810
01 800 087 6333
[email protected]
SOUTHERN AND
CENTRAL AMERICAN
COUNTRIES
CST Latinoamerica
Alameda Rio Negro, 1030,
18º andar – Conjunto 1803
CEP: 06454-000
Barueri - SP
BRASIL
Tel.: +55 (11) 4195 1384
Fax: +55 (11) 4195 1834
[email protected]
EUROPE
MIDDLE EAST
AFRICA
UNITED KINGDOM
Crydom SSR Ltd
Arena Business Centre
Holyrood, Close
Poole, Dorset BH17 7FJ
Sales Support
Tel.: +44 (0) 1202 606030
Fax: +44 (0) 1202 606035
[email protected]
Tech Support
[email protected]
AUSTRIA & SWITZERLAND
Tel.: +44 (0) 1202 606030
Fax: +44 (0) 1202 606035
[email protected]
GERMANY
Tel.: +49 (0) 180 3000 506
Fax: +49 (0) 180 3205 227
[email protected]
BELGIUM
Tel.: +32 (0) 2 460 4413
Fax: +32 (0) 2 461 2614
[email protected]
FRANCE
Tel.: +33 (0) 810 123 963
Fax: +33 (0) 810 057 605
[email protected]
ITALY
Tel.: +39 (0) 2 665 99 260
Fax: +39 (0) 2 665 99 268
[email protected]
THE NETHERLANDS
Tel.: +31 (0) 71 582 0068
Fax: +31 (0) 71 542 1648
[email protected]
SPAIN
Tel.: +34 902 876 217
Fax: +34 902 876 219
[email protected]
MIDDLE EAST,
AFRICA AND OTHER
EUROPEAN COUNTRIES
Tel.: +44 (0) 1202 606030
Fax: +44 (0) 1202 606035
[email protected]
ASIA
PACIFIC
CHINA & HONG KONG
Custom Sensors &
Technologies Asia
(Shanghai) Ltd.
2 Floor, Innovation Building,
No.1009, Yi Shan Road,
Shanghai, 200233
Tel.: +86 (21) 2401 7766
Fax: +86 (21) 6249 0701
[email protected]
TAIWAN
Custom Sensors &
Technologies
3F, No. 39, Ji-Hu Road
Nei-Hu Dist.
Taipei 114, Taiwan
Tel.: +886 2 8751 6388
Fax: +886 2 2657 8725
[email protected]
SOUTH KOREA
Custom Sensors &
Technologies
5F, Jeil Bldg.,
94-46 Youngdeungpo-dong 7-ga
Youngdeungpo-gu,
Seoul, 150-037
South Korea
Tel.: +82 2 2629 8312
Fax: +82 2 2629 8310
[email protected]
INDIA
CST Sensors India Pvt Ltd
Unit 1301 and 1302 Prestige
Meridian II
30 M.G.Road,
Bangalore - 560001
INDIA
Tel.: +91 (80) 4113 2204/05
Fax: +91 (80) 4113 2206
[email protected]
OTHER ASIAN AND
PACIFIC COUNTRIES
Custom Sensors &
Technologies
3F, No. 39, Ji-Hu Road
Nei-Hu Dist.
Taipei 114, Taiwan
Tel.: +886 2 8751 6388
Fax: +886 2 2657 8725
[email protected]
CAT/CR/SO/EN
Distributed by :
© 2010 Crydom Inc., All Rights Reserved.
Specifications are subject to change without prior notice.
Crydom and the Crydom logo are registered trademarks
of Crydom Inc.
08/2010