ED Series - Digi-Key

ED Series
The Global Expert in Solid State Relay Technology
ED Series
ABOUT US
Crydom, a brand of Custom Sensors & Technologies (CST) and global
expert in Solid State Relay Technology, has a distinguished record of
providing high quality, world class Solid State Relay and Control Products
for a variety of heating, lighting and motion control applications. Crydom
products, coupled with unparalleled technical support, timely delivery
and competitive pricing, provide Crydom’s clients with the innovative
products and support necessary to succeed in today’s competitive and
DIN RAIL OR PC MOUNTED PLUG-IN
SOLID STATE RELAYS & SOCKETS
“LIFEPLUS ED SERIES” PLUG IN SOLID
STATE RELAYS
Crydom’s new “LifePlus ED Series” of AC and DC Output Plug-in Solid
State Relays are designed to replace industry standard 12 x 29 mm plug-in
Electromechanical Relays. Crydom’s proven Solid State Relay
fast paced global markets.
Technology offers substantial performance advantages over traditional
Crydom’s extensive selection of standard off-the-shelf products is
greater life expectancy (>100 million operations), contactless high speed
EMR switching solutions in many applications including significantly
constantly being updated and expanded through its continuous
improvement and aggressive new product development programs.
Utilizing state of the art designs, materials and technology, Crydom offers
a wide range of AC and DC output SSRs in industry standard Panel Mount,
PCB Mount and DIN Rail packages, all meeting global safety and
switching which eliminates contact bounce, arcing and resulting electrical
noise, precise low power logic compatible control inputs, acoustically
silent operation and high shock and vibration resistance.
Available in a SPST N.O. configuration, the “LifePlus ED series” offer
output ratings of either 3 or 5 Amps rms at 24 to 280 VAC, or 5 Amps DC
standards agency requirements such as CE, RoHS, UL, IEC, etc.
at 1 to 48 or 1 to 80 VDC, all at 40 °C ambient temperature. AC outputs
Bolstered by four decades of Solid State Relay operations experience,
outputs utilize high efficiency FETs, both technologies resulting in the
Crydom also specializes and encourages
adapted
and
incorporate Crydom’s proven Back-to-Back SCR technology while DC
fully
custom-designed SSR products for nearly any application where unique
lowest possible on-state power dissipation and high surge current ratings
which makes the “Crydom LifePlus” an excellent choice for applications
specifications and optimized performance are critical for success.
such as small Motors, Solenoids, Heaters and Lamps. Optically isolated
Crydom’s modern purpose-built 100,000 square foot manufacturing
18 to 36 VAC and 90 to 140 VAC.
facility houses all aspects of its ISO certified operation including Design
and Development Engineering, Manufacturing Operations and Quality
Assurance, Customer Service, Finance, Marketing and General
Management, permitting close coordination of all aspects of Crydom’s
activities.
Applications Engineering and Sales support are both
performed in the field to provide Crydom’s Customers with the
unparalleled technical and commercial support.
Following rigid design guidelines and standards, Crydom products have
set the bench mark for SSR performance and reliability world wide. In
addition to award winning designs, Crydom has acquired an impressive
list of patents related to SSRs and Solid State Controls, while continuing
to develop new circuit and technology-related inventions as part of
control inputs available include 3 to 15 VDC, 18 to 32 VDC, 48 to 72 VDC,
Cydom’s “LifePlus ED Series” are UL 508 recognized for general
purpose, motor control and pilot duty applications, and compliant to IEC
62314 LC-A resistive and LC-B inductive application requirements. They
are also CE certified to the IEC Low Voltage Directive and compliant to the
IEC EMC directive.
“LIFEPLUS ED SERIES” DIN RAIL AND
PCB MOUNT ACCESSORY SOCKETS
The “LifePlus ED Series” includes accessory sockets accepting the
Crydom ED Series SSRs and industry standard 12 x 29 mm plug-in relay
packages. One version socket fits standard 35 mm DIN rail while a second
version is PCB mountable, allowing direct replacement of SPST N.O.
extensive R&D programs.
EMRs in both type installations. Equipped with screws for wire termination
To learn more about Crydom SSR technology and products, or how an
provide an easy means to install and utilize Crydom ED Series Solid State
and a positive latch for relay retention, the “LifePlus ED Series” sockets
alliance with Crydom can contribute to the success of your project, visit
www.crydom.com or contact your authorized Crydom Distributor or
Crydom Customer Service Representative today.
Relays.
Featuring all solid state construction, “LifePlus ED Series” SSRs and
Sockets provide an excellent improvement in performance over
traditional EMRs. For more information on “Crydom LifePlus” Series
SSRs, contact the nearest Crydom Distributor, Representative or Local
Crydom Sales Office, or visit our website at www.crydom.com.
www.crydom.com
ED Series
ED Series
AC Output Pluggable SSRs
12 x 29 mm industry standard plug-in package
3 & 5 Amps output power rating available
3 to 15 VDC, 18 to 32 VDC, 48 to 72 VDC, 18 to 36 VAC & 90 to 140 VAC control input
options available
Plug in replacement of EMRs
Convenient Quick Connect terminals for PCB or direct wiring
Fits standard DIN rail & PCB mountable sockets, also available as accessories
UL & IEC Resistive/Motor/Pilot Duty Ratings available
LED input status indicator
Zero Voltage for resistive loads and Random Turn-On for inductive loads versions available
Output Specifications (A)
ED24x3
ED24x5
24-280 VAC
Operating Voltage Range (47-63 Hz) [Vrms]
600
Transient Overvoltage [Vpk]
0.1
Maximum Off-State Leakage Current @ Maximum Operating Voltage [mArms]
500
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
500
3
Maximum Load Current [Arms]
5
150 mA
Minimum Load Current [Arms]
1 Cycle Surge Current (50/60 Hz) [Apk]
240 / 250 (C)
Maximum I²t for Fusing (50/60Hz) [A² sec]
285 / 260
600 / 625 (C)
1780 / 1620
≤1.1
Maximum On-State Voltage Drop @ Rated Current [Vpk]
0.5
Minimum Power Factor (with Maximum Load)
UL 508 Resistive Load @ 280 VAC [Arms]
3
5
UL 508 Motor Controller @ 240 VAC [HP]
¼
½
UL 508 Pilot Duty @ 120 V (Make/Break) [Amps] (B)
15 / 1.5
UL 508 Pilot Duty @ 240 V (Make/Break) [Amps] (B)
IEC 62314 LC-A @ 280 VAC [FLA]
7.5 / 0.75
IEC 62314 LC-B @ 240 VAC [Kw]
3
5
0.37
0.55
Input Specifications (A)
ED24Dx
ED24Cx
ED24Fx
ED24E5
ED24B5
Control Voltage Range
3-15 VDC
18-32 VDC
48-72 VDC
18-36 VAC
90-140 VAC
Minimum Turn-On Voltage
Must Turn-Off Voltage
3 VDC
18 VDC
48 VDC
18 VAC
90 VAC
1.9 VDC
10.5 VDC
24 VDC
10 VAC
48 VAC
Maximum Reverse Voltage [VDC]
6
Minimum Input Current (for on-state)
Maximum Input Current
Nominal Input Impeadance [Ohm]
3.8 mA @ 3 VDC
3.8 mA @ 18 VDC
3.8 mA @ 48 VDC
3.8 mA @ 18 VAC
3.2 mA @ 90 VAC
33.8 mA @ 15 VDC
6.9 mA @ 32 VDC
5.8 mA @ 72 VDC
8.5 mA @ 36 VAC
4.9 mA @ 140 VAC
500
4.8 K
12.5 K
4.5 K
28 K
Maximum Turn-On Time [msec] (Zero Voltage)
1/2 Cycle (D)
Maximum Turn-Off Time [msec]
1/2 Cycle (E)
General Specifications (A)
ED24x3
ED24x5
Dielectric Strength, Input to Output to Base (50/60Hz) [Vrms]
3750
Minimum Insulation Resistance @ 500 VDC
109
Maximum Capacitance, Input to Output [pF]
10
Ambient Operating Temperature Range [°C]
-30 to 80
Ambient Storage Temperature Range [°C]
IP ratings
-40 to 125
IP00 / IP10 when mounted in PCBSED / DRSED socket or equivalent
Housing Material
PBT 30% GF, UL 94 V0
Terminal Finish
Sulfamate Nickel
LED Status Indicator for Control Input
Weight (typical) [oz] (gr)
On: Green
0.705 (20)
1.06 (30)
Humidity
Quick Connect / 0.187 x 0.02 (4.75 x 0.51)
General Notes
Derating Curves (F, G)
(A) All parameters at 25ºC unless otherwise specified.
(B) Pilot duty ratings, per UL 508, available for ED24D3, ED24D5 & ED24E5.
(C) TJ = 25°C, time: 20 msec. (50 Hz) / 16.6 msec. (60 Hz).
(D) Turn-On time for Random-type AC Output (R suffix) is 0.1 msec for DC Control Models, and for AC Control
Models is 20 msec.
(E) Turn-Off Time for AC output versions with AC control is 30 msec.
(F) UL ratings are for relays only. To achieve maximum ratings, there must be a minimum spacing of 0.67 in (≥17 mm)
between the devices in free air.
(G) 100% Duty Cycle.
ED24xxx
6.0
Load Current (Amps)
Terminal type / size [in] (mm)
5 to 85% HR
5.0
4.0
3.0
2.0
1.0
0
10
5 Amps
3 Amps
20
30
40
50
Ambient Temperature (ºC)
Complete specifications of these & other Crydom products available at: www.crydom.com
60
70
80
ED Series
Wiring Diagram (J,K)
Part Number Nomenclature
Series
ED
Output Voltage
06: 1-48 VDC (5 Amps only)
10: 1-80 VDC (5 Amps only)
24: 24-280 VAC
24
C
RELAY (L,M)
Part no.: ED series
Operational Current
3: 3 Amps (not available with B & E suffixes)
5: 5 Amps
5
(Bottom view)
Load
4
R
4
(11)
2
Switching Mode
Blank: Zero Voltage Turn-On
(AC Output only)
R: Random Turn-On
(AC Output only)
Control Voltage
B: 90-140 VAC
C: 18-32 VDC
D: 3-15 VDC (H)
E: 18-36 VAC
F: 48-72 VDC
3
(14)
3
1
5
1 (A1)
Required for valid part number
For options only and not required for valid part number
5 (A2)
DC/AC
Control Voltage
Mechanical Dimensions
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
SOCKET
Part no.: PCBSED
1.10
[27.9]
.99
[25.0]
3
4
2
1.47
[37.4]
AC Output: 3 Amps
DC Output: C, D & F suffix
.82
[20.8]
3
(14)
Load
AC Output: 5 Amps
DC Output: B, E suffix
(Bottom view)
1
5
5 (A2)
1 (A1)
.02
[0.5]
.24
[6.1]
.30
[7.6]
.12
[3.0]
.20
[5.1]
.19
[4.8]
SOCKET (N,P)
Part no.: DRSED
.21
[5.3]
(Top view)
4
(11)
.10
[2.5]
1
4
(11)
4
2
2
4
3
(14)
3
3
Load
5
.39
[9.9]
.50
[12.7]
1.14
[29.0]
(H) 5-15 VDC range for ED06/10D5
(J) DC inductive loads must be diode suppressed.
(K) No grounding required.
(L) For sockets intended for AC input control voltage, the AC line can be wired to either DRSED socket terminal 1 (A1-) or terminal 5 (A2+). Proper
polarity must be observed for DC input control voltage sockets being terminal 5 (A2+) positive with respect to terminal 1 (A1-).
(M) For AC loads, the AC line can be wired to either DRSED socket terminal 4 (11) or terminal 3 (14). The AC load may also be wired on either the
line or neutral side of the SSR. For DC loads, the proper polarity must be observed for the power supply, load and DRSED socket with terminal
3 (14) being positive with respect to terminal 4 (11).
(N) Minimum wire strip lenght 0.197 in (5 mm), maximum 0.256 in (6.5 mm) for wiring socket DRSED.
(P) Input / Output terminals screw M3 Combo Drive for socket DRSED.
5 (A2)
1 (A1)
ED Series Accessories
DRSED
PCBSED
DIN Rail Mountable Socket
Part no.: DRSED
Fingersafe IP10 DIN rail mountable socket to
mount ED series relays onto standard 35 mm
DIN rail. Rated at 250 V AC/DC, 12 Amps. The
DRSED includes M3 Combo screws.
Questions?
Call or e-mail:
America Tel.: +1 (877) 502 5500
e-mail: [email protected]
EMEA Tel.: +44 (0) 1202 606030
e-mail: [email protected]
PC Board Mountable Socket
Part no.: PCBSED
PC Board mountable socket for ED series
relays. Rated at 250 V AC/DC, 12 Amps.
Suggested Pin-out hole diameter: 1.0 mm
Asia Tel.: +86 (0) 21 2401 7766
e-mail: [email protected]
ED Series
ED Series
DC Output Pluggable SSRs
12 x 29 mm industry standard plug-in package
5 Amps output power rating
5 to 15 VDC, 18 to 32 VDC, 48 to 72 VDC, 18 to 36 VAC & 90 to 140 VAC control
input options available
Plug in replacement of EMRs
Convenient Quick Connect terminals for PCB or direct wiring
Fits standard DIN rail & PCB mountable sockets, also available as accessories
UL & IEC Resistive/Motor Ratings available
LED input status indicator
Output Specifications (A)
ED06x5
Absolute maximum operating voltage [VDC]
Rated Voltage [VDC]
EDxxD5
ED10x5
60
100
1-48
1-80
EDxxC5
EDxxF5
EDxxE5
EDxxB5
N/A
20 (Q)
Maximum Off-State Leakage Current @ Rated Voltage [µA]
Maximum Load Current [A]
5
Minimum Load Current [A]
0.1
60 (R)
Maximum Surge Current (10ms) [ADC]
≤ 0.3
Maximum On-State Voltage Drop @ 40ºC Rated Current [VDC]
0.034 (S)
Maximum On-State Resistance (RDS-ON) [Ohm]
Maximum PWM (Hz)
500
500
500
N/A
UL 508 Resistive Load @ Rated Voltage [A]
5
5
5
5
5
UL 508 Motor Controller@ Rated Voltage [FLA]
2
2
2
1.5
1.5
IEC 60947-4-1 DC-1@ Rated Voltage [ADC]
5
5
5
5
5
IEC 60947-4-1 DC-3@ Rated Voltage [FLA]
5
5
5
5
5
Input Specifications (A)
EDxxD5
EDxxC5
EDxxF5
EDxxE5
EDxxB5
Control Voltage Range
5-15 VDC
18-32 VDC
48-72 VDC
18-36 VAC
90-140 VAC
Minimum Turn-On Voltage
5 VDC
18 VDC
48 VDC
18 VAC
90 VAC
1.3 VDC
2.0 VDC
4.0 VDC
4.0 VAC
11 VAC
11 mA @ 5 VDC
10.7 mA @ 18 VDC
10.8 mA @ 48 VDC
12 mA @ 18 VAC
7.3 mA @ 90 VAC
42.8 mA @ 15 VDC
19.7 mA @ 32 VDC
16.3 mA @ 72 VDC
25.3 mA @ 36 VAC
10.9 mA @ 140 VAC
350
1.6 K
4.4 K
1.5 K
12.5 K
EDxxE5
EDxxB5
Must Turn-Off Voltage
Maximum Reverse Voltage [VDC]
3
Minimum Input Current (for on-state)
Maximum Input Current
Nominal Input Impeadance [Ohm]
Maximum Turn-On Time [msec]
0.6
Maximum Turn-Off Time [msec]
0.3
General Specifications (A)
EDxxD5
EDxxC5
EDxxF5
Dielectric Strength, Input/Output/Base (50/60Hz) [Vrms]
2500
Minimum Insulation Resistance @ 500 VDC
109
Maximum Capacitance, Input/Output [pF]
10
Ambient Operating Temperature Range [°C]
-30 to 80
Ambient Storage Temperature Range [°C]
-40 to 125
Housing Material
PBT 30% GF, UL 94 V0
Terminal Finish
IP ratings
Sulfamate Nickel
IP00 / IP10 when mounted in PCBSED / DRSED socket or equivalent
LED Status Indicator for Control Input
On: Green
Weight (typical) [oz] (gr)
0.705 (20)
0.705 (20)
0.705 (20)
1.06 (30)
1.06 (30)
5 to 85% HR
Humidity
Terminal type / size [in] (mm)
Quick Connect / 0.187 x 0.020 (4.75 x 0.51)
General Notes
Derating Curves (T,G)
To view available Installation Sheet
scan the QR code with your
smartphone or visit www.crydom.com
ED06x5 & ED10x5
6.0
Load Current (Amps)
(A) All parameters at 25ºC unless otherwise specified.
(Q) Output Voltage is Maximum Operating Voltage, Control Voltage = 0 V, TJ = 25°C
(R) Output Voltage = 2.5 VDC
(S) At maximum load current
(T) UL ratings are for relays only. To achieve maximum ratings, there must be a minimum spacing of
0.63 in (≥16 mm) between the devices in free air
(G) 100% Duty Cycle
5.0
4.0
3.0
2.0
1.0
0
10
20
30
40
50
Ambient Temperature (ºC)
Complete specifications of these & other Crydom products available at: www.crydom.com
60
70
80
AMERICA
EUROPE, MIDDLE EAST
& AFRICA
United States & Canada
Crydom Inc
2320 Paseo de las Americas,
Suite 201
San Diego, CA 92154
Sales Support:
Tel.: +1 (877) 502 5500
Fax: +1 (619) 210 1590
[email protected]
Technical Support:
Tel.: +1 (877) 702 7700
[email protected]
United Kingdom
Crydom SSR Ltd
Arena Business Centre
Holyrood, Close
Poole, Dorset BH17 7FJ
Sales Support
Tel.: +44 (0) 1202 606030
Fax: +44 (0) 1202 606035
[email protected]
Tech Support
[email protected]
Mexico
American Countries
CST Latinoamerica
Alameda Rio Negro, 1030,
18º andar – Conjunto 1803
CEP: 06454-000
Barueri - São Paulo
Brasil
Tel.: +55 (11) 2505 7500
Fax: +55 (11) 2505 7507
[email protected]
Austria & Switzerland
Italy
Tel.: +44 (0) 1202 606030
Fax: +44 (0) 1202 606035
[email protected]
Tel.: +39 (0) 2 665 99 260
Fax: +39 (0) 2 665 99 268
[email protected]
Belgium
Spain
Tel.: +32 (0) 2 460 4413
Fax: +32 (0) 2 461 2614
[email protected]
Tel.: +34 902 876 217
Fax: +34 902 876 219
[email protected]
France
Netherlands
Tel.: +33 (0) 810 123 963
Fax: +33 (0) 810 057 605
[email protected]
Tel.: +31 (0) 71 582 0068
Fax: +31 (0) 71 542 1648
[email protected]
Germany
Middle East,
Africa & Other European
Countries
Tel.: +49 (0) 180 3000 506
Fax: +49 (0) 180 3205 227
[email protected]
ASIA PACIFIC
China & Hong Kong
Custom Sensors &
Technologies Asia
(Shanghai) Ltd.
13th floor
Chang Feng International
Tower
89 Yunling Road (East)
Putuo District
Shanghai, 200062
Sales Support
Tel.: +86 (0) 21 6065 6699
Fax: +86 (0) 21 6065 7749
[email protected]
Tech Support
[email protected]
Taiwan
Specifications are subject to change without prior notice.
Crydom and the Crydom logo are registered trademarks
of Crydom Inc.
05/2011
Tel. : +44 (0) 1202 606030
Fax: +44 (0) 1202 606035
[email protected]
India
Custom Sensors &
Technologies
2F, No. 39, Ji-Hu Road
Nei-Hu Dist.
Taipei 114
Tel: +886 2 8751 6388
Fax: +886 2 2657 8725
[email protected]
CST Sensors India Pvt Ltd
Unit 1301 and 1302 Prestige
Meridian II
30 M.G.Road,
Bangalore-560001
Tel: +91 (80) 4113 2204/05
Fax: +91 (80) 4113 2206
[email protected]
South Korea
South East Asian &
Pacific Countries
Custom Sensors &
Technologies
2F, Jeil Bldg.,
94-46 Youngdeungpo-dong
7-ga Youngdeungpo-gu,
Seoul, 150-037
Tel.: +82 2 2629 8312
Fax: +82 2 2629 8310
[email protected]
CAT/CR/LP/EN
© 2011 Crydom Inc., All Rights Reserved.
Southern & Central
Automatismo Crouzet
S.A. de C.V.
Calzada Zavaleta 2505-C Col
Sta Cruz Buenavista C.P.
72150 - Puebla
Sales Support:
Toll free: 01 800 087 6333
Tel. : +52 (222) 409 7000
Fax : +52 (222) 409 7810
[email protected]
Technical Support:
Toll free: 01 800 838 3736
Distributed by :
Custom Sensors &
Technologies
2F, No. 39, Ji-Hu Road
Nei-Hu Dist.
Taipei 114, Taiwan
Tel.: +886 2 8751 6388
Fax: +886 2 2657 8725
[email protected]