DataSheet

DIN Rail Mount
DataSheet
SeriesOne DR Series
ATEX
• Ratings 3 Amps
• Load voltage ratings of 1-60VDC, 1-100VDC, 24-280VAC and 48-600VAC
• Fits standard 35mm DIN-RAIL
• LED input status indicator
• AC or DC control
• Zero-crossing (resistive loads) or random turn-on (inductive loads) output
• UL 508 Endurance Rating for Enhanced Reliability
• UL Class I and II, Division 2, for Hazardous Locations
PRODUCT SELECTION
Control Voltage
280V, 3A
600V, 3A
60V, 3A
100V, 3A
4-32 VDC
90-140 VAC
200-280 VAC
18-36 VAC
DR24D03X
DR24B03X
DR24A03X
DR24E03X
DR48D03X
DR06D03X
DR10D03X
AVAILABLE OPTIONS
Series
DR
Operating Voltage
06: 1-60 VDC
10: 1-100 VDC
24: 24-280 VAC
48: 48-600 VAC
06
D
Rated Load Current
03: 3 Amps
03
X
Control Voltage
D: 4-32 VDC
A: 200-265 VAC
AC
Output
B: 90-140 VAC
Only
E: 18-36 VAC
Switching Type
Blank: Zero Voltage Turn-On
(AC Output Only)
R: Instantaneous Turn-On
(AC Output)
R
Agency Approvals
X: ATEX II 3G Ex nA IIC T4 Gc
approved
Required for valid part number
For options only and not required for valid part number
OUTPUT SPECIFICATIONS AC Output (1)
Description
DR24x03X
DR48x03X
Operating Voltage (2A)
Transient Overvoltage [Vpk]
Maximum Load Current, resistive (2)
Minimum Load Current [mArms]
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum Surge Current (50/60Hz, 1 cycle) [Apk]
Maximum I²t for Fusing (50/60 Hz, 1/2 cycle) [A² sec]
HP Rating UL 508/IEC60947 [HP (KW)] @ 240V
HP Rating UL 508/IEC60947 [HP (KW)] @ 380V
HP Rating UL 508/IEC60947 [HP (KW)] @ 480V
Minimum Power Factor (at Maximum Load)
Min/Max stranded wire
Min/Max solid wire
Weight (Typical)
24-280 Vrms
600
3 Arms
0.15 Arms
0.1
500
1.3
285/300
410/375
1/4 (.18)
1/2 (.37)
1/2 (.37)
0.5
22/14 AWG
22/14 AWG
1.76 oz. (50g)
48-600 Vrms
1200
3 Arms
0.15 Arms
0.1
500
1.3
285/300
410/375
1/4 (.18)
1/3 (.25)
1/2 (.37)
0.5
22/14 AWG
22/14 AWG
1.76 oz. (50g)
Do not forget to visit us at: www.crydom.com
Copyright © 2014 Crydom Inc. Specifications subject to change without notice.
DR06D03X
1-60 VDC
N/A
3
2.5 mA
0.1
N/A
0.6
60
N/A
N/A
N/A
N/A
N/A
22/14 AWG
22/14 AWG
1.76 oz. (50g)
DR10D03X
1-100 VDC
N/A
3
2.5 mA
0.1
N/A
0.6
60
N/A
N/A
N/A
N/A
N/A
22/14 AWG
22/14 AWG
1.76 oz. (50g)
DIN Rail Mount
DataSheet
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range (4)
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Minimum Input Current for [mA] (5)
Maximum Input Current for [mA] (5)
Maximum Turn-on Time [msec] (6) (7)
Maximum Turn-off Time [msec] (8)
Min/Max stranded/solid wire
DRxxDxxX
DRxxBxxX
4-32 VDC
4.0 VDC
1.0 VDC
9
11
1/2 Cycle
1/2 Cycle
22/16 AWG
90-140 Vrms
90 Vrms
10 Vrms
3
5
20 msec
30 msec
22/16 AWG
DRxxAxxX
DRxxExxX
200-265 Vrms
200 Vrms
40 Vrms
2.5
3.3
20 msec
30 msec
22/16 AWG
18-36 Vrms
18 Vrms
4 Vrms
3.5
8
20 msec
30 msec
22/16 AWG
GENERAL SPECIFICATIONS (1)
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Recommended Terminal Screw Torque Range
Parameters
4000 Vrms (9)
109 Ohm
10 pF
-30 to 80 °C
-30 to 100 °C
4,4-7.0 in lb (0.5-0.8Nm)
GENERAL NOTES
(1) All parameters at 25°C unless otherwise specified.
(2) See Derating curves
(2A) For AC output frequency is 47-63Hz
(3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
(4) DC control includes reverse polarity protection.
(5) Input circuitry incorporates active current limiter.
(6) Turn-on time for DC control random turn-on versions is 0.1 msec.
(7) Turn-on time for DC output 600µsec.
(8) Turn-off time for DC output 300µsec.
(9) 2500Vrms for DC output.
Standards of Complience
IEC 62314
LC A, Resistive or Slightly Inductive Load Ratings: 3A @40°C ambient for DR24x03X, 3A @ 40°C ambient for DR48x03X
LC B, Motor Loads Ratings: 0.18KW @ 240VAC for DR24x03X and 0.375KW @ 480VAC DR48x13X
Shock and Vibration (Applies to all part numbers)
Vibration Resistence according to IEC 60068-2-6: 0.35mm and 0.75mm Amplitude over 10-55 Hz
Shock Resistance according to IEC 60068-2-27: 15g/11ms
EMC (Applies to all part numbers)
IEC 61000-4-2: Electrostatic Discharge- Level 3
IEC 61000-4-4: Electrically Fast Transients- Level 3
IEC 61000-4-5: Electrical Surges- Level 3
ANSI / ISA 12.12.01-2013
Nonincendive Electrical Equipement for Use in class I and II, Division 2 and Class III, Division 1 and 2 Hazadous (classified) locations
This equipement is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipement is only accesible with the use of a tool
suitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations only
ATEX
Compliance with Essential Health and Safety Requiriments has been assessed by reference to Standards EN 60079-0:2012+A11:2013
and EN 60079-15-:2010
Do not forget to visit us at: www.crydom.com
Copyright © 2014 Crydom Inc. Specifications subject to change without notice.
DIN Rail Mount
DataSheet
MECHANICAL SPECIFICATIONS (1)
WIRING DIAGRAM
Do not forget to visit us at: www.crydom.com
Copyright © 2014 Crydom Inc. Specifications subject to change without notice.
DIN Rail Mount
DataSheet
THERMAL DERATE INFORMATION
DRxxx03X
Single and multiple units
Load Current (Amps)
3
2
1
0
0
10
20
30
40
50
60
70
80
Ambient Temperature (ºC)
AGENCY APPROVALS
IND. CONT. EQ.
4WB8
E116949
II 3G Ex nA IIC T4 Gc
Rev 042115
Do not forget to visit us at: www.crydom.com
Copyright © 2014 Crydom Inc. Specifications subject to change without notice.
DIN Rail Mount
DataSheet
ACCESORIES
Do not forget to visit us at: www.crydom.com
Copyright © 2014 Crydom Inc. Specifications subject to change without notice.
DIN Rail Mount
DataSheet
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
• Disconnect all
power before
installing or
working with
this equipment.
• Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
• Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
• Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
• Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
• Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
• Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
• Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSI
ONE.
• Spenga tutta
l'alimentazion
e che fornisce
questa
apparecchiatu
ra prima del
lavorare a questa
apparecchiatu ra
存在电击、
爆炸或电弧
闪烁危险
•
在操作此设
备之前请先
关闭电源。
若不遵守这些说明,
可能会导致严重的
人身伤害甚至死亡。
• Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima della
rotazione
sull'alimentazi one
L'omissione di
seguire queste
istruz ioni
provocherà la
morte o di
lesioni serie
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告
RISK OF MATERIAL DAMAGE AND HOT
ENCLOSURE
RISQUE DE DOMMAGE MATERIEL ET DE
SURCHAUFFE DU BOITIER
GEFAHR VON MATERIALSCHÄDEN UND
GEHÄUSEERHITZUNG
• The product's side panels may be hot, allow
the product to cool before touching.
• Follow proper mounting instructions including
torque values.
• Do not allow liquids or foreign objects to enter
this product.
• Les panneaux latéraux du produit peuvent être
chauds. Laisser le produit refroidir avant de le
toucher.
• Respecter les consignes de montage, et
notamment les couples de serrage.
• Ne pas laisser pénétrer de liquide ni de corps
étrangers à l'intérieur du produit.
• Die Seitenwände können heiß sein. Lassen Sie
das Produkt abkühlen, bevor Sie es berühren.
• Beachten Sie die Montageanweisungen,
• Führen Sie keine Flüssigkeiten oder
Fremdkörper in das Produkt ein.
Le non-respect de cette directive peut entraîner,
Failure to follow these instructions can result in des lésions corporelles graves ou des
serious injury, or equipment damage.
dommages matériels.
Die Nichtbeachtung dieser Anweisung kann
Körperverletzung oder Materialschäden
zur Folge haben.
RIESGO DE DAÑOS MATERIALES Y DE
SOBRECALENTAMIENTO DE LA UNIDAD
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO
CALDO
材料损坏和高温外壳的危险性
• Los paneles laterales del producto pueden
estar calientes. Esperar que el producto se
enfríe antes de tocarlo.
• Respetar las instrucciones de montaje, y en
particular los pares de apretado.
• No dejar que penetren líquidos o cuerpos
extraños en el producto.
• I pannelli laterali dell'apparecchio possono
scottare; lasciar quindi raffreddare il prodotto
prima di toccarlo.
• Seguire le istruzioni di montaggio corrette.
• Non far entrare liquidi o oggetti estranei in questo
apparecchio.
Si no se respetan estas precauciones pueden
producirse graves lesiones, daños materiales.
La mancata osservanza di questa precauzione può
causare gravi rischi per l'incolumità personale o
danni alle apparecchiature.
Do not forget to visit us at: www.crydom.com
Copyright © 2014 Crydom Inc. Specifications subject to change without notice.
• 产品的一侧面板可能很热,在其冷却前请
不要触碰。
• 遵照正确的安装说明,包括扭矩值。
• 请勿让液体及其他异物进入本产品。
如不能正确执行这些操作说明,
极有可能造成严重人体伤害或者设备的损坏。
DIN Rail Mount
DataSheet
ANNEX - ENVIROMENTAL INFORMATION
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.
Part
Name
Toxic or hazardous Substance and Elements
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr (VI))
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
Semiconductor die
Solder
附件 - 环保信息
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,
电子信息产品污染控制标识要求。
部件
名称
铅
汞
镉
有毒有害物质或元素
六价铬
多溴联苯
(Pb)
(Hg)
(Cd)
(Cr (VI))
半导体芯片
焊接点
50
Do not forget to visit us at: www.crydom.com
Copyright © 2014 Crydom Inc. Specifications subject to change without notice.
(PBB)
多溴二苯醚
(PBDE)