Data Sheet

DRA1 CX Series
• 10mm Single Channel DIN Rail Mount SSR Assembly
• AC Ratings up to 380 VAC and 5 Amps
• 3-15 and 15-32VDC control
• Cage style screw terminals for easy connection
• Fits standard 35mm DIN rail
• Includes LED Status indicator
PRODUCT SELECTION
Description
3-15 VDC Control
4-15 VDC Control
15-32 VDC Control
5A
5A
5A
DRA1-CX240D5
DRA1-CX240D5-B (2)
DRA1-CX240D5R
DRA1-CXE240D5
DRA1-CXE240D5R
5A
5A
DRA1-CX380D5
DRA1-CXE380D5
DRA1-CX380D5R
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage [VAC]
Transient Overvoltage [Vpk]
Maximum Load Current [Arms] (3)
Minimum Load Current [Arms]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum off-state dv/dt @ maximum rated voltage [V/µsec] (4)
Maximum 1 Cycle Surge Current (50/60 Hz) [Apk]
Maximum I²t for fusing (50/60 Hz, 1/2 cycle) [A² sec]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
CX(E)240x5
CX(E)380x5
12-280
600
5
0.06
0.1
500
239/250
285/260
1.4
48-380**
1200
5
0.06
0.1
500
239/250
285/260
1.4
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Must Turn On Voltage
Must Turn Off Voltage
Typycal Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec] (5)
Maximum Turn-Off Time [µsec]
DRA1-CX
DRA1-CX240D5-B (2)
DRA1-CX380D5
DRA1-CXE
3-15 VDC
3.0 VDC
1 .0 VDC
15 mAdc
300 Ohm
1/2 Cycle
1/2 Cycle
4-28 VDC
1.0 VDC
4 .0 VDC
10 mAdc
1360 Ohm
1/2 Cycle
1/2 Cycle
4-15 VDC
4.0 VDC
1 .0 VDC
15 mAdc
240 Ohm
1/2 Cycle
1/2 Cycle
15-32 VDC
15.0 VDC
1 .0 VDC
15 mAdc
1500 Ohm
1/2 Cycle
1/2 Cycle
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
Parameters
4000 VRMS
109 Ohms
10 pF
-30 to 80°C
-30 to 125 °C
0.063 lb (28.6g)
Themally Conductive Epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) The output is normally closed and does not have a LED status indicator
3) See Derating chart on page 3.
4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
5) Turn-on time for DC control random turn-on versions is 0.1 msec
**NOTE: Voltages in excess of 380V will damage output terminals.
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
E116950 (relay only)
LR81689 (relay only)
70938 UG (relay only)
Rev. 110811
ANNEX - ENVIROMENTAL INFORMATION