Datasheet

DRA4 CMX Series
• 54mm 4 Channel DIN Rail Mount SSR Assembly
• DC Ratings up to 200 VDC and 8 Amps
• 3-10 and 20-28VDC control
• Cage style screw terminals for easy connection
• Fits standard 35mm DIN rail
• Includes LED Status indicator
PRODUCT SELECTION
Description
3A
8 A (3)
DRA4-CMX200D3
DRA4-CMXE200D3
DRA4-CMX100D10
DRA4-CMXE100D10
Description
3A
8 A (3)
Operating Voltage [VDC]
Maximum Off-State Leakage Current @ Rated Voltage [µAdc]
Maximum Load Current [A] (2) (3)
Minimum Load Current [A]
Maximum On-State Resistence [Ohm]
Maximum Surge Current (10msec) [Apk]
Maximum On-State Voltage Drop @ Rated Current [VDC]
1-200
100
3
0
0.2
30
0.6
1-100
100
8
0
0.01
100
0.1
3-10 VDC Control
20-28 VDC Control
OUTPUT SPECIFICATIONS (1)
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Must Turn On Voltage
Must Turn Off Voltage
Typycal Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [µsec]
DRA4-CMX
DRA4-CMXE
3.0-10.0 VDC
3.0 VDC
1 .0 VDC
15 mAdc @ 5Vdc
300 Ohm
1
300
20.0-28.0 VDC
20.0 VDC
1 .0 VDC
12 mAdc @ 20 Vdc
780 Ohm
1
300
GENERAL SPECIFICATIONS
Description
Parameters
Dielectric Strength (4)
Minimum Insulation Resistance (@ 500 VDC)(4)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
2500 Vrms
109 Ohms
15 pF
-30 to 80°C
-30 to 125°C
0.23 oz. (104.6g)
Thermally Conductive Epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) See derating chart on page 3.
3) Steady state load Current exceeding 8 amps will damage socket.
4).Dielectric and insulation resistance is measured between input and output.
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
E116950 3 and 10A CMX relays only
Rv. 110811
ANNEX - ENVIROMENTAL INFORMATION