Bussmann series NH catalogue Leadership in circuit protection Energizing a world that demands more. We deliver: • Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable • Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power • Aerospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently • Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions Discover today’s Eaton. Powering business worldwide As a global power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery and businesses. Eaton’s innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, efficiently, safely and sustainably. 2 EATON Bussmann series NH catalogue We provide integrated solutions that help make energy, in all its forms, more practical and accessible. With 2014 sales of $22.6 billion, Eaton has approximately 100,000 employees around the world and sells products in more than 175 countries. Eaton.com Table of contents Section Page Section Page NH Fuse links technical data Technical data 4 - 11 4-6 690 Volts range - gG Technical data 32 - 39 32 NH Fuse links applications Features of the NH DIN range 7 8 Catalogue numbers summary Size 000 33 34 Product range overview 9 Ordering key Sizing guide 9 10 Size 00 Size 1 Size 2 35 36 37 NH Fuse links dimensions - mm 11 Size 3 Size 4 38 39 400 Volts range - gG Technical data Catalogue numbers summary 12 - 18 12 13 Size 000 Size 00 Sizes 01 and 1 Sizes 02 and 2 14 15 16 17 Sizes 03 and 3 18 500 Volts range - gG Technical data Catalogue numbers summary Size 000 19 - 31 19 20 - 21 22 Size 00 Size 0 Size 01 23 24 25 Size 1 Size 02 Size 2 Size 03 Size 3 Size 4 26 27 28 29 30 31 500 and 690 Volts range - aM Technical data Catalogue numbers summary Size 000 40 - 46 40 41 42 Size 00 Size 1 Size 2 43 44 45 Size 3 46 Accessories NH Fuse bases and accessories NH Fuse rails - vertical NH Fuse switch disconnectors - vertical NH Fuse switch disconnectors - horizontal Index 47 - 63 47 - 52 53 - 55 56 - 61 62 - 74 75 - 76 EATON Bussmann series NH catalogue 3 NH Fuse links technical data Introduction Bussmann’s NH fuse link range uses the latest technology to provide class leading fuse link performance and reliable indication. With a unique patented dual indicator design capable of operating a microswitch for remote fuse indication, Bussmann provides one of the most reliable solutions available. The range is fully compliant with IEC 60269-1 and 2 standards, with VDE 0636-2 third party approval and complies with the dimensional requirements of DIN 43620 for ease of use. In order to help select the correct product for an application, Bussmann provides the following application notes. Selecting the correct product Non-fault overload currents (motor inrush currents etc) Before making a fuse link selection the following information should be known about the system or circuit to be protected. To prevent nuisance operation of the fuse link, the fuse link rating selected for the application should take into account any non-fault overload currents. Please refer to the time-current curves in the catalogue. Type of application (cable protection/motor protection) For general applications or cable protection, the standard gG (general purpose) NH fuse link should be considered. For Motor protection applications, the aM (motor protection) NH fuse link should be considered. Motor Protection (aM) fuse links have partial range breaking ability and cannot clear low overload faults. They should only be applied to circuits also protected by a motor protection relay or where only high short-circuit faults could occur. Note: Please note that misapplication of a fuse link can be problematical, consult Bussmann if there is any doubt over fuse link selection. System voltage Bussmann’s NH fuse links are available in three voltage ratings, 400 V, 500 V and 690 V. These are maximum voltage ratings and should not be used where the nominal system voltage could exceed the fuse link’s maximum rating. Full load current In accordance with IEC standards, Bussmann’s NH fuse links are tested to carry full load current. The Current of a fuse link should be equal or greater than the operational current of the circuit and equal or smaller than the continuous current carrying capacity of the conductor. The standard gG (general purpose) NH fuse link with a conventional fusing current of 1.6 times Current will give assured cable protection against the effects of overcurrents. 4 EATON Bussmann series NH catalogue Possible fault conditions and maximum short-circuit current This information is essential in order to select the fuse link that would provide the best possible protection under all fault conditions. Bussmann’s NH fuse links have a maximum breaking capacity of 120 kA and should never be used on a system where the maximum short-circuit current exceeds this level. Please refer to the time-current curves in the catalogue. Time-current curves The time-current curve is probably the most useful piece of all fuse link data available. It allows you to determine how quickly the fuse link will operate under fault conditions and which fuse link will not operate under non-fault overload currents. To use the curve simply plot the prospective Root Mean Square (RMS) fault current along the X axis and draw a line vertically upwards from this point. Where this point intersects the fuse curve line, plot a line across to the Y axis for the relevant rating. The Y axis shows the nominal operating time for the fuse in seconds. Hence, it shows how quickly the fuse link will operate under different fault currents. The graph can be used to check if a fuse link can withstand an overload condition that is not considered to be a fault such as a direct-on-line (DOL) motor start. For example, if a motor starts and the inrush current is six times the full load current for 10 seconds, the exact point can be plotted onto the time-current curve. Any fuse link line lying to the right of this point will withstand the motor start current (allowing for a +/-10% tolerance on each fuse link curve). If the fuse link curve falls to the left of this point, then the fuse link will not withstand the motor start current and will inadvertently operate when the motor is started. In summary, the rule for time-current curves is that any point on or to the right of a fuse link curve would indicate the fuse link has operated in the given time. Any point to the left of the curve would indicate the fuse link has not operated. Cut-off curves The graph consists of an A-B line running diagonally from bottom left to top right, see drawing below. This is known as the non current-limiting line. Branching from this A-B line you can see each individual fuse link rating line running diagonally left to right. To read the graph, plot the RMS prospective fault current along the X axis. If this point only intersects the A-B line then the prospective fault current is too low to benefit from the current-limiting effect of the fuse link. However, if this point intersects the relevant fuse link line, plot a line across to the Y axis. This point on the Y axis shows the peak asymmetrical let-through current the fuse link will allow to pass before operating. The peak asymmetrical let-through current is the absolute worst case peak current the fuse link will allow to pass through, taking into account the DC offset seen under short-circuit conditions and low power factor. The RMS let-through current is read from the graph using the same procedure above. Instead of plotting the point of intersection with the fuse link current-limiting line over to the Y axis, it should only be plotted as far as the A-B line. At this point, a line can be drawn back down to the X axis to show a RMS symmetrical value of let-through current. This is known as the “up, over and down method”. EATON Bussmann series NH catalogue 5 I²t values I²t values are measured at the time of testing the fuse link at their rated breaking capacity and voltage. I²t is effectively the amount of heating energy the fuse link will allow to pass during fault clearing at high short-circuit faults. I²t values relevant for short-circuit faults cannot be calculated from the time-current or cut-off curves. The published I²t figures always show two values, pre-arcing/total clearing and are representative of the area under the first half cycle of the fault current. • The pre-arcing value is the area under the first half cycle of fault current showing on the graph in yellow to the point just before an arc occurs within the fuse link. This is due to the element material being vaporised by the very high short-circuit current. • The total clearing I²t is the yellow and green area under the first half cycle from the start of the short-circuit current flow to the point where the fuse link has become an insulator, completely isolating the flow of current. The diagram here shows a representation of I²t during a half cycle of fault current. I²t values give a good representation of the speed of operation of a fuse link. A small I²t value would indicate a very fast-acting fuse link whereas a large I²t value would indicate a fairly slow operating fuse link. In all cases the total clearing I²t value of the fuse link must be smaller than the I²t value of the device to be protected in order for the fuse link to provide adequate protection against short-circuit faults. For fuse link discrimination (see definition of discrimination below) in distribution systems, the total clearing I²t value of the fuse link downstream should be less than the pre-arc- ing I²t value of the fuse link upstream. This ensures the smaller fuse link, in the system operates well before the larger upstream fuse link. NH discrimination Bussmann’s NH fuse links are easy to use on distribution networks where discrimination between large and small fuse links are required. This can be achieved by applying a discrimination factor of 1 to 1.6 without the need to check the fuse link data. For example, by using a 100 A fuse link downstream from the main 160A fuse link, in the event of a fault condition, the smaller 100A fuse link is sure to operate before the 160A fuse link, ensuring discrimination. DC applications Bussmann’s NH fuse links can be used on DC applications. In all cases the fuse links can be used at half of their AC rating with a time constant of no more than 10mS. The time constant is the rate of rise of fault current and should be as close to a 50Hz AC half cycle as possible. Power loss Every effort is made to ensure the power loss of the fuse link is kept to a minimum. Bussmann provides fuse links with some of the lowest power losses in the industry. Power loss of the fuse link is given off as heat and this should be taken into account when fitting fuse links into unventilated areas. It is preferable that a fuse link has good airflow around the body of the fuse link to ensure cool running and prevent nuisance operation of the fuse link due to thermal stresses. Should further information be required please contact Bussmann’s application engineers: 00 44 (0) 1509 882 699 or [email protected] 6 EATON Bussmann series NH catalogue NH Fuse links applications NH fuse links can be found on a solar distribution network NH fuse links can be found in a wind turbine NH fuse links can be found on the low voltage side of substations NH fuse links can be used for protection of cables and distribution circuits NH fuse links can be used for industrial motor applications EATON Bussmann series NH catalogue 7 Lug is voltage free NH Dual indicator system from Bussmann • High breaking capacity • 400, 500 and 690 V a.c. • Dual indication • Insulated tag variants option available • IEC 60269-1 and 2, DIN 43620, VDE 0636-2, CE Mark. Lug is live part Metal Gripping Lugs Features of the NH DIN range Dual indicator system Bussmann’s patented dual indicator provides clear indication, ensuring extremely reliable local and remote* signalling, decreasing fuse link replacement time and costs. * with the use of an optional microswitch accessory Low power loss Bussmann’s “low watts loss” fuse links reduce overall operating costs and carbon footprint through lower energy consumption and heat transfer to equipment. To find out how much you can save, please contact our technical applications department: [email protected]. Globally compliant Bussmann’s NH fuse links are tested and comply with IEC 60269-1 and 2, DIN 43620, VDE, CE, CCC (China), RoHS and can be recycled, ensuring global acceptance. Lead and cadmium free Bussmann is the world’s first true manufacturer of a complete range of Lead and Cadmium free NH fuse links. Negating any legislation concerns regarding the amount of hazardous materials permissible within the fuse links. Recycling Bussmann is dedicated to produce recyclable products and is a member of an industry recognised recycling scheme. The “HRC” symbol on Bussmann’s NH fuse links define the product suitable for recycling, limiting disposal cost. 8 EATON Bussmann series NH catalogue Cd/Pb-free Insulated Metal Gripping Lugs Amps Size Class Voltage (V a.c.) Product range overview gG 400 000 2 4 6 10 16 20 25 32 35 40 50 63 80 100 125 160 200 224 250 300 315 355 400 425 450 500 630 800 1000 00 125 160 01 1 02 35 40 50 63 80 100 125 160 16 16 200 224 250 17 35 40 50 63 80 100 125 160 200 224 250 315 355 400 03 250 gG 500 22 50 63 80 100 125 160 23 6 10 16 20 25 32 35 40 50 63 80 100 125 160 24 25 6 10 16 20 25 32 35 40 50 63 80 100 125 160 50 63 80 100 125 160 200 224 250 02 gG 26 315 355 27 35 40 50 63 80 100 125 160 200 224 250 2 250 300 315 355 400 425 450 500 28 03 250 29 315 355 400 000 00 1 500 630 800 1000 50 63 80 100 125 160 31 36 50 63 80 100 125 160 200 224 250 200 224 250 3 250 37 315 315 355 400 425 38 500 630 800 39 42 6 10 16 20 25 32 35 40 50 43 63 80 100 1 1250 34 35 2 4 6 10 16 20 25 32 35 40 50 63 2 000 00 30 315 355 400 425 450 500 630 800 4 aM 18 2 4 6 10 16 20 25 32 35 40 50 63 80 100 4 690 18 500 630 3 500 and 690 17 630 315 355 400 3 0 01 1 Page 14 15 2 000 00 1250 2 4 6 10 16 20 25 32 35 40 50 63 80 100 44 50 63 80 100 125 160 2 125 160 200 224 250 3 45 315 355 315 355 400 500 46 : Part available, for example Size 00 400 V is available in 125 and 160A Ordering key Current rating NH fuse link Utilisation class Body size Bussmann by Eaton Insulated metal gripping lugs (optional) Complete Catalogue Numbers 100 Intuitive catalogue numbers NH G 000 B 100 NH G 000 B I I Bussmann logical catalogue numbering system provides simple identification of fuse link current, utilisation class, size and voltage, ensuring easy identification on site reducing replacement time and improving network productivity. EATON Bussmann series NH catalogue 9 Sizing guide Size 000 Size 02 Size 00 Size 2 Size 0 Size 03 Size 01 Size 3 Size 1 Size 4 10 EATON Bussmann series NH catalogue NH Fuse links dimensions - mm Size a1 a2 (max) a3 a4 b c1 c2 d e1 (max) e2 (max) e3 (max) e4 f (max) 000 78.5±1.5 54 45±1.5 49±1.5 15 35 10 2±0.5 41 21 16 6 8 00 0 78.5±1.5 125±2.5 54 68 45±1.5 62 +3 -1.5 49±1.5 68 +1.5 -3 15 15 35 35 11 11 2±0.5 2.5±0.5 48 48 30 30 25 25 6 6 15 15 01 1 02 2 03 3 4* 135±2.5 135±2.5 150±2.5 150±2.5 150±2.5 150±2.5 200±3 75 75 75 75 75 75 84 62±2.5 62±2.5 62±2.5 62±2.5 62±2.5 62±2.5 62±2.5 68±2.5 68±2.5 68±2.5 68±2.5 68±2.5 68±2.5 90±3 15 20 20 25 25 32 50 40 40 48 48 60 60 85 11 11 11 11 11 11 10 2.5±0.5 2.5±0.5 2.5±0.5 2.5±0.5 2.5±0.5 3±0.5 3±0.5 48 53 53 61 61 75 102 30 40 40 53 53 70 102 25 25 25 25 25 25 25 6 6 6 6 6 6 8 15 15 15 15 15 18 30 * Size 4 is a single indication fuse lin with slotted end tags EATON Bussmann series NH catalogue 11 400 V a.c. - class gG/gL - 2 to 630 amps - sizes 000 to 3 Description 400Vac A square bodied range of industrial fuse links for a wide variety of applications. Catalogue numbers structure • (amp)NHG(size)B-400 e.g. 100NHG02B-400 with conducting metal gripping lugs • (amp)NHG(size)BI-400 e.g. 100NHG000BI-400 with insulated metal gripping lugs Class of operation • gL/gG. Standards / approvals • IEC 60269-1 and 2, VDE 0636, DIN 43620 and CE. Technical data • Sizes 000 to 3 • Voltage: 400 V a.c. • Current: 2 to 630 A • Rated breaking capacity: 120 kA AC • Rated frequency: 50Hz • Operating frequency: 45-62Hz. Optional microswitch • BVL50 or 170H0236. Compatible fuse holders • • Fuse bases 1 pole: • SD(size)-D DIN-Rail mounted • SD(size)-S: Screw mounting Fuse bases 3 pole • TD(size)-D, DIN-Rail mounted • Fuse bases accessories: IP20, shroud and phase barrier kits • Fuse rails - vertical: EBF series • Fuse switch disconnectors vertical: EBV series • Fuse switch disconnectors horizontal: EBH series. Environmental • Recyclable • RoHS compliant • Lead and cadmium free. Packaging • All fuse links are packed in threes. Features: • Reliable dual indicator system • Low temperature rise • Globally compliant. Data sheet 720099 12 EATON Bussmann series NH catalogue 400 V a.c. - class gG/gL - 2 to 630 amps - sizes 000 to 3 Catalogue Numbers Size 000 00 01 1 Voltage Conducting Metal Gripping Lugs 2NHG000B-400 4NHG000B-400 6NHG000B-400 10NHG000B-400 Insulated Metal Gripping Lugs 2NHG000BI-400 4NHG000BI-400 6NHG000BI-400 10NHG000BI-400 16 16NHG000B-400 16NHG000BI-400 20 20NHG000B-400 20NHG000BI-400 25 25NHG000B-400 25NHG000BI-400 32 35 32NHG000B-400 35NHG000B-400 32NHG000BI-400 35NHG000BI-400 40 50 40NHG000B-400 50NHG000B-400 40NHG000BI-400 50NHG000BI-400 63 63NHG000B-400 63NHG000BI-400 80 100 80NHG000B-400 100NHG000B-400 80NHG000BI-400 100NHG000BI-400 125NHG00B-400 125NHG00BI-400 160NHG00B-400 35NHG01B-400 40NHG01B-400 50NHG01B-400 63NHG01B-400 160NHG00BI-400 35NHG01BI-400 40NHG01BI-400 50NHG01BI-400 63NHG01BI-400 80 100 80NHG01B-400 100NHG01B-400 80NHG01BI-400 100NHG01BI-400 125 160 200 125NHG01B-400 160NHG01B-400 200NHG1B-400 125NHG01BI-400 160NHG01BI-400 200NHG1BI-400 224NHG1B-400 250NHG1B-400 224NHG1BI-400 250NHG1BI-400 35NHG02B-400 40NHG02B-400 50NHG02B-400 35NHG02BI-400 40NHG02BI-400 50NHG02BI-400 63 80 100 63NHG02B-400 80NHG02B-400 100NHG02B-400 63NHG02BI-400 80NHG02BI-400 100NHG02BI-400 125 160 200 224 250 125NHG02B-400 160NHG02B-400 200NHG02B-400 224NHG02B-400 250NHG02B-400 125NHG02BI-400 160NHG02BI-400 200NHG02BI-400 224NHG02BI-400 250NHG02BI-400 315NHG2B-400 355NHG2B-400 400NHG2B-400 630NHG2B-400 250NHG03B-400 315NHG03B-400 355NHG03B-400 400NHG03B-400 500NHG3B-400 630NHG3B-400 315NHG2BI-400 355NHG2BI-400 400NHG2BI-400 250NHG03BI-400 315NHG03BI-400 355NHG03BI-400 400NHG03BI-400 500NHG3BI-400 630NHG3BI-400 125 160 35 40 50 63 Voltage (V a.c.) 400 400 400 400 224 250 02 2 03 3 35 40 50 315 355 400 630 250 315 355 400 500 630 400 400 400 400 400Vac gG/gL Dual Indicator Current (Amps) 2 4 6 10 Pack Quantity 3 3 3 3 3 3 3 3 EATON Bussmann series NH catalogue 13 400 V a.c. - class gG/gL - 2 to 100 amps - size 000 Time-current characteristics Time in seconds (s) 400Vac Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 2NHG000B-400 4NHG000B-400 6NHG000B-400 10NHG000B-400 16NHG000B-400 20NHG000B-400 25NHG000B-400 32NHG000B-400 35NHG000B-400 40NHG000B-400 50NHG000B-400 63NHG000B-400 80NHG000B-400 100NHG000B-400 Catalogue Numbers With Insulated Metal Gripping Lugs 2NHG000BI-400 4NHG000BI-400 6NHG000BI-400 10NHG000BI-400 16NHG000BI-400 20NHG000BI-400 25NHG000BI-400 32NHG000BI-400 35NHG000BI-400 40NHG000BI-400 50NHG000BI-400 63NHG000BI-400 80NHG000BI-400 100NHG000BI-400 I²t (Amps² Seconds) Fuse Link Size 000 Current (Amps) 2 4 6 10 16 20 25 32 35 40 50 63 80 100 Voltage (V a.c.) 400 Minimum Pre-Arcing 3.5 6 14 60 240 584 1000 2400 2900 4000 4000 6000 9900 18,100 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 720099 14 EATON Bussmann series NH catalogue *I1 120 kA at 400 V a.c. 5.5 10.5 19 175 710 1800 2800 9600 11,300 16,400 12,000 20,400 35,700 39,800 Watts Loss (W) 0.8 1.4 2.2 1.5 2.3 2.2 3.1 2.8 2.8 3 3.4 4.5 4.7 5.2 Net Weight Per Fuse (Kg) 0.133 400 V a.c. - class gG/gL - 125 and 160 amps - size 00 Time in seconds (s) 400Vac Time-current characteristics Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 125NHG00B-400 160NHG00B-400 Catalogue Numbers With Insulated Metal Gripping Lugs 125NHG00BI-400 160NHG00BI-400 I²t (Amps² Seconds) Fuse Link Size 00 Current (Amps) 125 160 Voltage (V a.c.) 400 Minimum Pre-Arcing 25,000 60,000 *I1 120 kA at 400 V a.c. 80,000 126,000 Watts Loss (W) 8 7.8 Net Weight Per Fuse (Kg) 0.185 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 720099 EATON Bussmann series NH catalogue 15 400 V a.c. - class gG/gL - 35 to 250 amps - sizes 01 & 1 Time-current characteristics Time in seconds (s) 400Vac Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 35NHG01B-400 40NHG01B-400 50NHG01B-400 63NHG01B-400 80NHG01B-400 100NHG01B-400 125NHG01B-400 160NHG01B-400 200NHG1B-400 224NHG1B-400 250NHG1B-400 Catalogue Numbers With Insulated Metal Gripping Lugs 35NHG01BI-400 40NHG01BI-400 50NHG01BI-400 63NHG01BI-400 80NHG01BI-400 100NHG01BI-400 125NHG01BI-400 160NHG01BI-400 200NHG1BI-400 224NHG1BI-400 250NHG1BI-400 I²t (Amps² Seconds) Fuse Link Size 01 1 Current (Amps) 35 40 50 63 80 100 125 160 200 224 250 Voltage (V a.c.) 400 400 Minimum Pre-Arcing 2400 3300 4200 6600 9600 16,000 24,000 53,000 89,000 119,000 171,000 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 720099 16 EATON Bussmann series NH catalogue *I1 120 kA at 400 V a.c. 7600 10,600 10,400 16,300 33,600 56,000 86,400 111,300 232,000 322,000 479,000 Watts Loss (W) 4.9 5 4.7 5.6 5.6 6.8 8.8 8.9 12 12 14 Net Weight Per Fuse (Kg) 0.269 0.387 400 V a.c. - class gG/gL - 35 to 630 amps - sizes 02 & 2 Time-current characteristics 10 000 315 2 250 1 000 224 6 200 4 160 2 125 100 100 6 80 TIME - Seconds 4 Time in seconds (s) 400Vac 400 355 6 4 63 2 50 10 40 35 6 4 2 630 1 6 4 2 0.1 6 4 2 0.01 6 8 100 2 4 6 8 1000 Current in Amps (A) CURRENT - Amperes 2 4 6 8 10 000 2 Technical data Catalogue Numbers With Metal Gripping Lugs 35NHG02B-400 40NHG02B-400 50NHG02B-400 63NHG02B-400 80NHG02B-400 100NHG02B-400 125NHG02B-400 160NHG02B-400 200NHG02B-400 224NHG02B-400 250NHG02B-400 315NHG2B-400 355NHG2B-400 400NHG2B-400 630NHG2B-400 Catalogue Numbers With Insulated Metal Gripping Lugs 35NHG02BI-400 40NHG02BI-400 50NHG02BI-400 63NHG02BI-400 80NHG02BI-400 100NHG02BI-400 125NHG02BI-400 160NHG02BI-400 200NHG02BI-400 224NHG02BI-400 250NHG02BI-400 315NHG2BI-400 355NHG2BI-400 400NHG2BI-400 - I²t (Amps² Seconds) Fuse Link Size 02 2 Current (Amps) 35 40 50 63 80 100 125 160 200 224 250 315 355 400 630 Voltage (V a.c.) 400 400 Minimum Pre-Arcing 2400 3300 4200 6600 10,000 16,000 24,000 50,000 89,000 119,000 171,000 280,000 350,000 504,000 2,100,000 *I1 120 kA at 400 V a.c. 7600 10,600 10,400 16,300 34,800 56,000 86,400 185,000 232,000 322,000 479,000 924,000 1,155,000 1,673,000 5,775,000 Watts Loss (W) 4.4 5 6.5 5.5 5.5 6.6 8.7 10 12 12 14 19 22 24 44 Net Weight Per Fuse (Kg) 0.402 0.630 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 720099 EATON Bussmann series NH catalogue 17 400 V a.c. - class gG/gL - 250 to 630 amps - sizes 03 & 3 Time-current characteristics Time in seconds (s) 400Vac Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 250NHG03B-400 315NHG03B-400 355NHG03B-400 400NHG03B-400 500NHG3B-400 630NHG3B-400 Catalogue Numbers With Insulated Metal Gripping Lugs 250NHG03BI-400 315NHG03BI-400 355NHG03BI-400 400NHG03BI-400 500NHG3BI-400 630NHG3BI-400 I²t (Amps² Seconds) Fuse Link Size 03 3 Current (Amps) 250 315 355 400 500 630 Voltage (V a.c.) 400 400 Minimum Pre-Arcing 115,000 280,000 350,000 504,000 686,000 1,590,000 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 720099 18 EATON Bussmann series NH catalogue *I1 120 kA at 400 V a.c. 379,500 924,000 1,155,000 1,663,000 2,605,000 6,201,000 Watts Loss (W) 18 19 22 24 30 36 Net Weight Per Fuse (Kg) 0.634 1.043 500 V a.c. - class gG/gL - 2 to 1250 amps - sizes 000 to 4 Description A square bodied range of industrial fuse links for a wide variety of applications. Catalogue Numbers structure • (amp)NHG(size)B e.g. 100NHG01B. Class of operation gL/gG. 500Vac • Standards / approvals • IEC 60269-1 and 2, VDE 0636, DIN 43620 and CE. Technical data • Sizes 000 to 4 • Voltage: 500 V a.c. • Current: 2 to 1250 A • Rated breaking capacity: 120 kA AC • Operating frequency: 45-62Hz. Optional microswitch • BVL50 or 170H0236. Compatible fuse holders • • Fuse bases 1 pole: • SD(size)-D DIN-Rail mounted • SD(size)-S: Screw mounting Fuse bases 3 pole • TD(size)-D, DIN-Rail mounted • Fuse bases accessories: IP20, shroud and phase barrier kits • Fuse rails - vertical: EBF series • Fuse switch disconnectors vertical: EBV series • Fuse switch disconnectors horizontal: EBH series Environmental • Recyclable • RoHS compliant • Lead and cadmium free. Packaging • Size 000 to 3: 3 in a pack / Size 4: 1 in a pack. Features: • Reliable dual indicator system (size 4 single indication only) • Low temperature rise • Globally compliant. Data sheet 10164 EATON Bussmann series NH catalogue 19 500 V a.c. - class gG/gL - 2 to 1250 amps - sizes 000 to 4 Catalogue Numbers - sizes 000 to 01 gG/gL Dual indicator Size 000 500Vac 00 Current (Amps) 2 4 Voltage (V a.c.) 500 Voltage Conducting Metal Gripping Lugs 2NHG000B 4NHG000B Insulated Metal Gripping Lugs 2NHG000BI 4NHG000BI 6 6NHG000B 6NHG000BI 10 16 10NHG000B 16NHG000B 10NHG000BI 16NHG000BI 20 20NHG000B 20NHG000BI 25 32 25NHG000B 32NHG000B 25NHG000BI 32NHG000BI 35 40 35NHG000B 40NHG000B 35NHG000BI 40NHG000BI 50 50NHG000B 50NHG000BI 63 80 100 63NHG000B 80NHG000B 100NHG000B 63NHG000BI 80NHG000BI 100NHG000BI 50NHG00B 63NHG00B 80NHG00B 50NHG00BI* 63NHG00BI* 80NHG00BI* 100NHG00B 125NHG00B 160NHG00B 100NHG00BI* 125NHG00BI 160NHG00BI 6NHG0B 10NHG0B 16NHG0B - 20 25 32 20NHG0B 25NHG0B 32NHG0B - 35 40 50 63 80 100 125 160 6 10 16 20 25 32 35 40 50 63 80 100 125 160 35NHG0B 40NHG0B 50NHG0B 63NHG0B 80NHG0B 100NHG0B 125NHG0B 160NHG0B 6NHG01B 10NHG01B 16NHG01B 20NHG01B 25NHG01B 32NHG01B 35NHG01B 40NHG01B 50NHG01B 63NHG01B 80NHG01B 100NHG01B 125NHG01B 160NHG01B 6NHG01BI 10NHG01BI 16NHG01BI 20NHG01BI 25NHG01BI 32NHG01BI 35NHG01BI 40NHG01BI 50NHG01BI 63NHG01BI 80NHG01BI 100NHG01BI 125NHG01BI 160NHG01BI 50 63 80 500 100 125 160 0 01 6 10 16 500 500 * Available upon request Data sheet 10164 20 EATON Bussmann series NH catalogue Pack Quantity 3 3 3 3 500 V a.c. - class gG/gL - 2 to 1250 amps - sizes 000 to 4 Catalogue Numbers - sizes 1 to 4 gG/gL Dual Indicator Voltage Conducting Metal Gripping Lugs 50NHG1B Insulated Metal Gripping Lugs 50NHG1BI 63 63NHG1B 63NHG1BI 80 80NHG1B 80NHG1BI 100 125 100NHG1B 125NHG1B 100NHG1BI 125NHG1BI 160 160NHG1B 160NHG1BI 200 224 200NHG1B 224NHG1B 200NHG1BI 224NHG1BI 250NHG1B 315NHG1B 250NHG1BI 315NHG1BI 355NHG1B 355NHG1BI 35NHG02B 40NHG02B 50NHG02B 63NHG02B 80NHG02B 35NHG02BI 40NHG02BI 50NHG02BI 63NHG02BI 80NHG02BI 100 125 100NHG02B 125NHG02B 100NHG02BI 125NHG02BI 160 200 160NHG02B 200NHG02B 160NHG02BI 200NHG02BI 224 250 250 300 315 224NHG02B 250NHG02B 250NHG2B 300NHG2B 315NHG2B 224NHG02BI 250NHG02BI 250NHG2BI 300NHG2BI 315NHG2BI 355NHG2B 400NHG2B 425NHG2B 450NHG2B 500NHG2B 250NHG03B 315NHG03B 355NHG03B 400NHG03B 315NHG3B 355NHG3B 400NHG3B 425NHG3B 450NHG3B 500NHG3B 630NHG3B 800NHG3B 500NHG4G 630NHG4G 800NHG4G 1000NHG4G 1250NHG4G 355NHG2BI 400NHG2BI 425NHG2BI 450NHG2BI 500NHG2BI 250NHG03BI 315NHG03BI 355NHG03BI 400NHG03BI - 250 315 Voltage (V a.c.) 500 440 355 02 2 03 3 4** 35 40 50 63 80 355 400 425 450 500 250 315 355 400 315 355 400 425 450 500 630 800 500 630 800 1000 1250 500 500 440 500 500 440 500 - Pack Quantity 3 500Vac Size 1 Current (Amps) 50 3 3 3 3 3 3 3 1 * Available upon request ** Size 4 NH is a single indication fuse with slotted end tags Data sheet 10164 EATON Bussmann series NH catalogue 21 500 V a.c. - class gG/gL - 2 to 100 amps - size 000 Time-current characteristics Time in seconds (s) 500Vac Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 2NHG000B 4NHG000B 6NHG000B 10NHG000B Catalogue Numbers With Insulated Metal Gripping Lugs 2NHG000BI 4NHG000BI 6NHG000BI 10NHG000BI 16NHG000B 20NHG000B 25NHG000B 32NHG000B 35NHG000B 40NHG000B 50NHG000B 63NHG000B 80NHG000B 100NHG000B 16NHG000BI 20NHG000BI 25NHG000BI 32NHG000BI 35NHG000BI 40NHG000BI 50NHG000BI 63NHG000BI 80NHG000BI 100NHG000BI I²t (Amps² Seconds) Fuse Link Size 000 Current (Amps) 2 4 6 10 16 20 25 32 35 40 50 63 80 100 Voltage (V a.c.) 500 Minimum Pre-Arcing 3.5 6 14 58 *I1 120 kA at 500 V a.c. 6 12 21 290 Watts Loss (W) 3.9 1.8 2 1.5 234 490 920 1800 2400 3300 5900 6300 9800 18,100 1200 2500 4600 9000 11,800 16,500 29,500 24,900 38,900 72,300 2.3 2.2 3.1 3.4 3.7 4 4.9 4.6 6.3 7.4 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10164 22 EATON Bussmann series NH catalogue Net Weight Per Fuse (Kg) 0.130 500 V a.c. - class gG/gL - 50 to 160 amps - size 00 Time in seconds (s) 500Vac Time-current characteristics Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 50NHG00B 63NHG00B 80NHG00B 100NHG00B 125NHG00B 160NHG00B Catalogue Numbers With Insulated Metal Gripping Lugs 50NHG00BI 63NHG00BI 80NHG00BI 100NHG00BI 125NHG00BI 160NHG00BI I²t (Amps² Seconds) Fuse Link Size 00 Current (Amps) 50 63 80 100 125 160 Voltage (V a.c.) 500 Minimum Pre-Arcing 5800 5800 11,000 19,000 25,000 64,000 *I1 120 kA at 500 V a.c. 21,500 25,000 35,000 60,000 125,000 310,000 Watts Loss (W) 5 5 7 7.5 10 10 Net Weight Per Fuse (Kg) 0.190 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10164 EATON Bussmann series NH catalogue 23 500 V a.c. - class gG/gL - 6 to 160 amps - size 0 Time-current characteristics 10 000 160 125 6 4 100 2 1 000 6 500Vac 4 80 2 63 50 100 40 6 35 TIME (Seconds) Time in seconds (s) 4 32 25 20 2 10 16 6 10 4 2 1 6 4 2 6 0.1 6 4 2 0.01 6 10 8 2 4 6 8 100 2 4 6 8 1000 2 4 6 Current in(Amperes) Amps (A) CURRENT Technical data Catalogue Numbers With Metal Gripping Lugs 6NHG0B 10NHG0B 16NHG0B 20NHG0B 25NHG0B 32NHG0B 35NHG0B 40NHG0B 50NHG0B 63NHG0B 80NHG0B 100NHG0B 125NHG0B 160NHG0B I²t (Amps² Seconds) Fuse Link Size 0 Current (Amps) 6 10 16 20 Voltage (V a.c.) 500 25 32 35 40 50 63 80 100 125 160 Minimum Pre-Arcing 14 58 240 490 *I1 120 kA at 500 V a.c. 21 290 1200 2500 Watts Loss (W) 2 2 3 3.5 1200 1800 2400 3300 5600 6600 9800 20,600 25,000 62,000 5600 9000 11,800 16,500 27,800 26,100 38,900 82,300 125,000 310,000 3.2 4.8 4.7 5 6.3 5.6 7.1 7.5 11.8 12.3 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10164 24 EATON Bussmann series NH catalogue Net Weight Per Fuse (Kg) 0.260 500 V a.c. - class gG/gL - 6 to 160 amps - size 01 Time-current characteristics 10 000 6 4 2 1 000 6 160 4 125 80 100 63 6 50 40 Time in seconds (s) 4 TIME (Seconds) 500Vac 100 2 35 2 32 10 25 6 4 2 1 20 6 16 4 10 2 0.1 6 6 4 2 0.01 4 6 8 10 2 4 6 8 100 2 Current in Amps (A) CURRENT (Amperes) 4 6 8 1000 2 4 Technical data Catalogue Numbers With Metal Gripping Lugs 6NHG01B 10NHG01B 16NHG01B 20NHG01B Catalogue Numbers With Insulated Metal Gripping Lugs 6NHG01BI 10NHG01BI 16NHG01BI 20NHG01BI 25NHG01B 32NHG01B 35NHG01B 40NHG01B 50NHG01B 63NHG01B 80NHG01B 100NHG01B 125NHG01B 160NHG01B 25NHG01BI 32NHG01BI 35NHG01BI 40NHG01BI 50NHG01BI 63NHG01BI 80NHG01BI 100NHG01BI 125NHG01BI 160NHG01BI I²t (Amps² Seconds) Fuse Link Size 01 Current (Amps) 6 10 16 20 25 32 35 40 50 63 80 100 125 160 Voltage (V a.c.) 500 Minimum Pre-Arcing 14 58 240 490 *I1 120 kA at 500 V a.c. 21 290 1200 2500 Watts Loss (W) 2 2 3 3.4 1200 1800 2400 3300 5600 6600 9800 20,600 25,000 62,000 5600 9000 11,800 16,500 27,800 26,100 38,900 82,300 125,000 310,000 5 4.8 4.6 5 6.3 5.6 7.1 7.7 11.8 12.3 Net Weight Per Fuse (Kg) 0.270 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10164 EATON Bussmann series NH catalogue 25 500 V a.c. - class gG/gL - 50 to 355 amps - size 1 Time-current characteristics Time in seconds (s) 500Vac Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 50NHG1B 63NHG1B 80NHG1B 100NHG1B 125NHG1B 160NHG1B 200NHG1B 224NHG1B 250NHG1B 315NHG1B 355NHG1B Catalogue Numbers With Insulated Metal Gripping Lugs 50NHG1BI 63NHG1BI 80NHG1BI 100NHG1BI 125NHG1BI 160NHG1BI 200NHG1BI 224NHG1BI 250NHG1BI 315NHG1BI 355NHG1BI I²t (Amps² Seconds) Fuse Link Size 1 Current (Amps) 50 63 80 100 125 160 200 224 250 315 355 Voltage (V a.c.) 500 440 Minimum Pre-Arcing 6350 6800 10,500 22,000 29,000 62,000 97,000 124,000 151,300 320,000 320,000 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10164 26 EATON Bussmann series NH catalogue *I1 120 kA at 500 V a.c. 18,000 23,000 31,200 68,200 82,000 310,000 368,600 471,200 574,900 750,000 750,000 Watts Loss (W) 6.4 5.6 7.7 8.2 13 12.3 15 18 19 22 32 Net Weight Per Fuse (Kg) 0.390 500 V a.c. - class gG/gL - 35 to 250 amps - size 02 Time in seconds (s) 500Vac Time-current characteristics Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 35NHG02B 40NHG02B 50NHG02B 63NHG02B 80NHG02B 100NHG02B 125NHG02B 160NHG02B 200NHG02B 224NHG02B 250NHG02B Catalogue Numbers With Insulated Metal Gripping Lugs 35NHG02BI 40NHG02BI 50NHG02BI 63NHG02BI 80NHG02BI 100NHG02BI 125NHG02BI 160NHG02BI 200NHG02BI 224NHG02BI 250NHG02BI I²t (Amps² Seconds) Fuse Link Size 02 Current (Amps) 35 40 50 63 80 100 125 160 200 224 250 Voltage (V a.c.) 500 Minimum Pre-Arcing 2400 3300 5600 6600 9800 20,600 25,000 62,000 96,900 124,000 151,300 *I1 120 kA at 500 V a.c. 11,800 16,500 27,800 26,100 38,900 82,300 100,000 248,000 367,900 471,200 574,900 Watts Loss (W) 4.7 5 6.4 5.5 7.3 7.5 12 12 15 18 19 Net Weight Per Fuse (Kg) 0.402 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10164 EATON Bussmann series NH catalogue 27 500 V a.c. - class gG/gL - 250 to 500 amps - size 2 Time-current characteristics Time in seconds (s) 500Vac Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 250NHG2B 300NHG2B 315NHG2B 355NHG2B 400NHG2B 425NHG2B 450NHG2B 500NHG2B Catalogue Numbers With Insulated Metal Gripping Lugs 250NHG2BI 300NHG1BI 315NHG2BI 355NHG2BI 400NHG2BI 425NHG2BI 450NHG2BI 500NHG2BI I²t (Amps² Seconds) Fuse Link Size 2 2 Current (Amps) 250 300 315 355 400 425 450 500 Voltage (V a.c.) 500 440 Minimum Pre-Arcing 170,000 320,000 361,700 446,500 642,900 720,000 870,000 1,200,000 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10164 28 EATON Bussmann series NH catalogue *I1 120 kA at 500 V a.c. 437,000 840,000 1,446,500 1,785,800 2,571,500 1,862,000 2,275,000 2,720,000 Watts Loss (W) 23 20 21 27 30 31 31 37 Net Weight Per Fuse (Kg) 0.630 500 V a.c. - class gG/gL - 250 to 400 amps - size 03 Time in seconds (s) 500Vac Time-current characteristics Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 250NHG03B 315NHG03B 355NHG03B 400NHG03B Catalogue Numbers With Insulated Metal Gripping Lugs 250NHG03BI 315NHG03BI 355NHG03BI 400NHG03BI I²t (Amps² Seconds) Fuse Link Size 03 Current (Amps) 250 315 355 400 Voltage (V a.c.) 500 Minimum Pre-Arcing 160,800 361,700 446,500 642,900 *I1 120 kA at 500 V a.c. 642,900 1,446,500 1,785,800 2,571,500 Watts Loss (W) 20 21 27 30 Net Weight per Fuse (Kg) 0.640 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10164 EATON Bussmann series NH catalogue 29 500 V a.c. - class gG/gL - 315 to 800 amps - size 3 Time-current characteristics Time in seconds (s) 500Vac Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 315NHG3B 355NHG3B 400NHG3B 425NHG3B 450NHG3B 500NHG3B 630NHG3B 800NHG3B I²t (Amps² Seconds) Fuse Link Size 3 3 Current (Amps) 315 355 400 425 450 500 630 800 Voltage (V a.c.) 500 440 Minimum Pre-Arcing 375,000 400,000 642,900 570,000 670,000 886,000 1,590,000 2,420,000 *I1 120 kA at 500 V a.c. 970,000 1,110,000 2,571,500 1,934,000 2,260,000 3,898,400 6,996,000 5,420,000 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10164 30 EATON Bussmann series NH catalogue Watts Loss (W) 22 25 30 30 33 37 47 59 Net Weight Per Fuse (Kg) 1.050 1.050 500 V a.c. - class gG/gL - 500 to 1250 amps - size 4* Time in seconds (s) 500Vac Time-current characteristics Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 500NHG4G 630NHG4G 800NHG4G 1000NHG4G 1250NHG4G I²t (Amps² Seconds) Fuse Link Size 4 Current (Amps) 500 630 800 1000 1250 Voltage (V a.c.) 500 Minimum Pre-Arcing 800,000 880,000 1,500,000 4,800,000 7,000,000 **I1 120 kA at 500 V a.c. 3,850,000 4,100,000 6,480,000 13,000,000 18,000,000 Watts Loss (W) 37 47 68 80 108 Net Weight Per Fuse (Kg) 2.200 * Size 4 NH is a single indication fuse with slotted end tags ** I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10164 EATON Bussmann series NH catalogue 31 690 V a.c. - class gG/gL - 2 to 800 amps - sizes 000 to 4 Description A square bodied range of industrial fuse links for a wide variety of applications. Catalogue Numbers structure • (amp)NHG(size)B-690 e.g. 2NHG000B-690. Class of operation • gL/gG. Standards / approvals • IEC 60269-1 and 2, DIN 43620 Part 1 and 3. Technical data 690Vac gG • Sizes 000 to 4 • Voltage: 690 V a.c. • Current: 2 to 800 A • Rated breaking capacity: 120 kA • Operating frequency: 45-62Hz. Optional microswitch • BVL50 or 170H0236. Compatible fuse holders • • Fuse bases 1 pole: • SD(size)-D DIN-Rail mounted • SD(size)-S: Screw mounting Fuse bases 3 pole • TD(size)-D, DIN-Rail mounted • Fuse bases accessories: IP20, shroud and phase barrier kits • Fuse rails - vertical: EBF series • Fuse switch disconnectors vertical: EBV series • Fuse switch disconnectors horizontal: EBH series Environmental • Recyclable • RoHS compliant • Lead and cadmium free for sizes 000 to 4 (2 to 1250A). Packaging • Sizes 000 to 3: 3 per carton • Size 4: 1 per carton Features: • Reliable dual indicator system (size 4 single indication only) • Low temperature rise • Globally compliant • UL on limited ratings. Data sheet 720109 32 EATON Bussmann series NH catalogue 690 V a.c. - class gG/gL - 2 to 800 amps - sizes 000 to 4 Catalogue Numbers- sizes 000 to 4 gG/gL Dual Indicator 00 Voltage (V a.c.) 690 4 4NHG000B-690 6 10 6NHG000B-690 10NHG000B-690 16 20 25 16NHG000B-690 20NHG000B-690 25NHG000B-690 32 35 32NHG000B-690 35NHG000B-690 40 40NHG000B-690 50 50NHG000B-690 63 50 63 80 690 100 125 160 1 2 3 4* Voltage Conducting Metal Gripping Lugs 2NHG000B-690 50 63 63NHG000B-690 50NHG00B-690 63NHG00B-690 80NHG00B-690 3 100NHG00B-690 660 690 125NHG00B-690 160NHG00B-660 50NHG1B-690 63NHG1B-690 80 100 80NHG1B-690 100NHG1B-690 125 160 200 125NHG1B-690 160NHG1B-690 200NHG1B-690 224 250 200 224 250 315 250 315 224NHG1B-690 250NHG1B-690 200NHG2B-690 224NHG2B-690 250NHG2B-690 315NHG2B-690 250NHG3B-690 315NHG3B-690 355 400 425 500 630 800 Pack Quantity 3 690Vac gG Size 000 Current (Amps) 2 690 690 690 355NHG3B-690 400NHG3B-690 425NHG3B-690 500NHG3B-690 630NHG4B-690 800NHG4B-690 3 3 3 3 1 *Size 4 is a fuse link with single indication fuse link with slotted end tags Please consult us should you wish to order 500 Volts size 4 [email protected] or 00 44 (0) 1509 882 699 Data sheet 720109 EATON Bussmann series NH catalogue 33 690 V a.c. - class gG/gL - 2 to 63 amps - size 000 690Vac gG Time in seconds (s) Time-current characteristics Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 2NHG000B-690 4NHG000B-690 6NHG000B-690 10NHG000B-690 16NHG000B-690 20NHG000B-690 25NHG000B-690 32NHG000B-690 35NHG000B-690 40NHG000B-690 50NHG000B-690 63NHG000B-690 I²t (Amps² Seconds) Fuse Link Size 000 Current (Amps) 2 4 6 10 16 20 25 32 35 40 50 63 Voltage (V a.c.) 690 Minimum Pre-Arcing 3.5 6 14 60 240 500 920 1800 2800 3300 6100 6500 *I1 120 kA at 690 V a.c. 8 16 25 400 1200 2500 4400 9600 15,000 15,000 26,500 30,500 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 720109 34 EATON Bussmann series NH catalogue Watts Loss (W) 4 2 2 1.5 2.5 2.5 3.5 3.5 4 4 5.5 5.5 Net Weight Per Fuse (Kg) 0.118 690 V a.c. - class gG/gL - 50 to 160 amps - size 00 690Vac gG Time in seconds (s) Time-current characteristics Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 50NHG00B-690 63NHG00B-690 80NHG00B-690 100NHG00B-690 125NHG00B-690 160NHG00B-660 I²t (Amps² Seconds) Fuse Link Size 00 00 Current (Amps) 50 63 80 100 125 160 Voltage (V a.c.) 690 660 Minimum Pre-Arcing 5800 5800 11,000 19,000 27,500 40,500 *I1 120 kA at 690 V a.c. 35,000 43,000 54,500 92,000 105,000 135,000 Watts Loss (W) 5 5 7 7.5 9.5 13 Net Weight Per Fuse (Kg) 0.182 0.182 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 720109 EATON Bussmann series NH catalogue 35 690 V a.c. - class gG/gL - 50 to 250 amps - size 1 690Vac gG Time in seconds (s) Time-current characteristics Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 50NHG1B-690 63NHG1B-690 80NHG1B-690 100NHG1B-690 125NHG1B-690 160NHG1B-690 200NHG1B-690 224NHG1B-690 250NHG1B-690 I²t (Amps² Seconds) Fuse Link Size 1 Current (Amps) 50 63 80 100 125 160 200 224 250 Voltage (V a.c.) 690 Minimum Pre-Arcing 6350 6800 10,500 22,000 29,000 71,000 105,000 120,000 150,000 *I1 120 kA at 690 V a.c. 26,500 36,000 47,500 105,000 120,000 240,000 350,000 430,000 520,000 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 720109 36 EATON Bussmann series NH catalogue Watts Loss (W) 6.4 5.6 7.7 8.2 13 13 17 19 22 Net Weight Per Fuse (Kg) 0.380 690 V a.c. - class gG/gL - 200 to 315 amps - size 2 690Vac gG Time in seconds (s) Time-current characteristics Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 200NHG2B-690 224NHG2B-690 250NHG2B-690 315NHG2B-690 I²t (Amps² Seconds) Fuse Link Size 2 Current (Amps) 200 224 250 315 Voltage (V a.c.) 690 Minimum Pre-Arcing 99,000 130,000 170,000 295,000 *I1 120 kA at 690 V a.c. 385,000 485,000 625,000 760,000 Watts Loss (W) 18 20 23 32 Net Weight Per Fuse (Kg) 0.620 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 720109 EATON Bussmann series NH catalogue 37 690 V a.c. - class gG/gL - 250 to 500 amps - size 3 690Vac gG Time in seconds (s) Time-current characteristics Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 250NHG3B-690 315NHG3B-690 355NHG3B-690 400NHG3B-690 425NHG3B-690 500NHG3B-690 I²t (Amps² Seconds) Fuse Link Size 3 Current (Amps) 250 315 355 400 425 500 Voltage (V a.c.) 690 Minimum Pre-Arcing 160,000 375,000 400,000 475,000 630,000 856,000 *I1 120 kA at 690 V a.c. 715,000 1,400,000 1,650,000 1,600,000 1,700,000 2,480,000 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 720109 38 EATON Bussmann series NH catalogue Watts Loss (W) 21 22 25 37 35 43 Net Weight Per Fuse (Kg) 1.050 690 V a.c. - class gG/gL - 630 and 800 amps - size 4* 690Vac gG Time in seconds (s) Time-current characteristics Current in Amps (A) Technical data Catalogue Numbers With Metal Gripping Lugs 630NHG4B-690 800NHG4B-690 I²t (Amps² Seconds) Fuse Link Size 4 Current (Amps) 630 800 Voltage (V a.c.) 690 Minimum Pre-Arcing 1,730,000 3,330,000 *I1 120 kA at 690 V a.c. 6,550,000 11,000,000 Watts Loss (W) 44 61 Net Weight Per Fuse (Kg) 2.500 *Single indication fuse link with slotted end tags ** I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Please consult us should you wish to order 500 Volts size 4 [email protected] or 00 44 (0) 1509 882 699 Data sheet 720109 EATON Bussmann series NH catalogue 39 500 and 690 V a.c. - class aM - 6 to 500 amps - sizes 000 to 3 Description A range of class aM square bodied industrial fuse links for a wide variety of motor protection applications. Catalogue Numbers structure • 500 Volts: (amp)NHM(size)B • 690 Volts: (amp)NHM(size)B-690. Class of operation • aM. Standards / approvals • IEC 60269-1 and 2, DIN 43620 Part 1 and 3. Technical data • Sizes 000 to 3 • Voltage: 500 and 690 V a.c. • Current: 6 to 500 A • Rated breaking capacity: 120 kA • Operating frequency: 45-62Hz. Optional microswitch • BVL50 or 170H0236. aM Compatible fuse holders • • Fuse bases 1 pole: • SD(size)-D DIN-Rail mounted • SD(size)-S: Screw mounting Fuse bases 3 pole • TD(size)-D, DIN-Rail mounted • Fuse bases accessories: IP20, shroud and phase barrier kits • Fuse rails - vertical: EBF series • Fuse switch disconnectors vertical: EBV series • Fuse switch disconnectors horizontal: EBH series Environmental • Recyclable • RoHS compliant • Lead and cadmium free. Packaging • All fuse links are packed in threes. Features: • Reliable dual indicator system (except size 2, 315 and 355 A which are single indication) • Low watts loss • Metal gripping lugs. Data sheet 10165 40 EATON Bussmann series NH catalogue 500 and 690 V a.c. - class aM - 6 to 500 amps - sizes 000 to 3 Catalogue Numbers- sizes 000 to 3 00 1 2 3 690 V a.c. class aM Current (Amps) 6 10 Voltage Conducting Metal Gripping Lugs 6NHM000B 10NHM000B Voltage Conducting Metal Gripping Lugs 6NHM000B-690 10NHM000B-690 16 16NHM000B 16NHM000B-690 20 25 20NHM000B 25NHM000B 20NHM000B-690 25NHM000B-690 32 32NHM000B 32NHM000B-690 35 40 50 63 35NHM000B 40NHM000B 50NHM000B 63NHM00B 35NHM000B-690 40NHM000B-690 50NHM000B-690 63NHM00B-690 80 80NHM00B 80NHM00B-690 100 50 63 100NHM00B 50NHM1B 63NHM1B 100NHM00B-690 50NHM1B-690 63NHM1B-690 80 100 125 160 80NHM1B 100NHM1B 125NHM1B 160NHM1B 80NHM1B-690 100NHM1B-690 125NHM1B-690 160NHM1B-690 125 160 200 125NHM2B 160NHM2B 200NHM2B 125NHM2B-690 160NHM2B-690 200NHM2B-690 224 250 224NHM2B 250NHM2B 224NHM2B-690 250NHM2B-690 315* 355* 315 315NHM2B* 355NHM2B* 315NHM3B 315NHM2B-690* 355NHM2B-690* 315NHM3B-690 355 400 500 355NHM3B 400NHM3B 500NHM3B 355NHM3B-690 400NHM3B-690 500NHM3B-690 Pack Quantity 3 3 3 3 aM Size 000 500 V a.c. class aM 3 * Single indication Data sheet 10165 EATON Bussmann series NH catalogue 41 500 and 690 V a.c. - class aM - 6 to 50 amps - size 000 Time in seconds (s) Time-current characteristics aM Current in Amps (A) Technical data 500 V a.c. 690 V a.c. Catalogue Numbers With Metal Gripping Lugs 6NHM000B 10NHM000B 16NHM000B 20NHM000B 25NHM000B 32NHM000B 35NHM000B 40NHM000B 50NHM000B Catalogue Numbers With Metal Gripping Lugs 6NM000B-690 10NHM000B-690 16NHM000B-690 20NHM000B-690 25NHM000B-690 32NHM000B-690 35NHM000B-690 40NHM000B-690 50NHM000B-690 I²t (Amps² Seconds) Fuse Link Size 000 Current (Amps) 6 10 16 20 25 32 35 40 50 Minimum Pre-Arcing 48 200 500 1450 3500 2200 3000 4700 11,000 *I1 120 kA at 690 V a.c. 650 1800 4400 7250 13,500 7500 12,000 14,500 27,000 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10165 42 EATON Bussmann series NH catalogue Watts Loss (W) 0.3 0.5 0.8 0.9 1.1 2.1 2.1 2.3 2.7 Net Weight Per Fuse (Kg) 0.118 500 and 690 V a.c. - class aM - 63 to 100 amps - size 00 aM Time in seconds (s) Time-current characteristics Current in Amps (A) Technical data 500 V a.c. 690 V a.c. Catalogue Numbers With Metal Gripping Lugs 63NHM00B 80NHM00B 100NHM00B Catalogue Numbers With Metal Gripping Lugs 63NHM00B-690 80NHM00B-690 100NHM00B-690 I²t (Amps² Seconds) Fuse Link Size 00 Current (Amps) 63 80 100 Minimum Pre-Arcing 16,000 24,000 35,000 *I1 120 kA at 690 V a.c. 52,000 69,500 110,000 Watts Loss (W) 3.1 4.3 5.5 Net Weight Per Fuse (Kg) 0.186 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10165 EATON Bussmann series NH catalogue 43 500 and 690 V a.c. - class aM - 50 to 160 amps - size 1 Time in seconds (s) Time-current characteristics aM Current in Amps (A) Technical data 500 V a.c. 690 V a.c. Catalogue Numbers With Metal Gripping Lugs 50NHM1B 63NHM1B 80NHM1B 100NHM1B 125NHM1B 160NHM1B Catalogue Numbers With Metal Gripping Lugs 50NHM1B-690 63NHM1B-690 80NHM1B-690 100NHM1B-690 125NHM1B-690 160NHM1B-690 I²t (Amps² Seconds) Fuse Link Size 1 Current (Amps) 50 63 80 100 125 160 Minimum Pre-Arcing 10,000 12,500 19,500 33,000 49,500 110,000 *I1 120 kA at 690 V a.c. 39,500 49,500 77,500 105,000 170,000 315,000 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10165 44 EATON Bussmann series NH catalogue Watts Loss (W) 3 4.4 5.6 6.7 8.8 10.6 Net Weight Per Fuse (Kg) 0.380 500 and 690 V a.c. - class aM - 125 to 355 amps - size 2 aM Time in seconds (s) Time-current characteristics Current in Amps (A) Technical data 500 V a.c. 690 V a.c. Catalogue Numbers With Metal Gripping Lugs 125NHM2B 160NHM2B 200NHM2B 224NHM2B 250NHM2B 315NHM2B* 355NHM2B* Catalogue Numbers With Metal Gripping Lugs 125NHM2B-690 160NHM2B-690 200NHM2B-690 224NHM2B-690 250NHM2B-690 315NHM2B-690* 355NHM2B-690* I²t (Amps² Seconds) Fuse Link Size 2 Current (Amps) 125 160 200 224 250 315 355 Minimum Pre-Arcing 56,500 120,000 175,000 255,000 300,000 510,000 570,000 **I1 120 kA at 690 V a.c. 215,000 510,000 730,000 1,050,000 1,280,000 1,150,000 1,300,000 Watts Loss (W) 9.7 11 14 15 17 23 28 Net Weight Per Fuse (Kg) 0.615 * Single indication ** I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10165 EATON Bussmann series NH catalogue 45 500 and 690 V a.c. - class aM - 315 to 500 amps - size 3 Time in seconds (s) Time-current characteristics aM Current in Amps (A) Technical data 500 V a.c. 690 V a.c. Catalogue Numbers With Metal Gripping Lugs 315NHM3B 355NHM3B 400NHM3B 500NHM3B Catalogue Numbers With Metal Gripping Lugs 315NHM3B-690 355NHM3B-690 400NHM3B-690 500NHM3B-690 I²t (Amps² Seconds) Fuse Link Size 3 Current (Amps) 315 355 400 500 Minimum Pre-Arcing 480,000 500,000 680,000 1,050,000 *I1 120 kA at 690 V a.c. 1,600,000 1,300,000 2,000,000 2,800,000 * I1 is the maximum breaking capacity test at Voltage according to IEC 60269-1 and 2 requirements Data sheet 10165 46 EATON Bussmann series NH catalogue Watts Loss (W) 20 27 28 36 Net Weight Per Fuse (Kg) 1.050 NH Fuse bases and accessories - SD and TD series Description NH fuse bases with thermoplastic bodies, DIN rail and/or screw mounting (size 4 screw mounting only). Range of accessories including phase barriers, IP20 finger-safe protection kits and neutral links available. Microswitch also available for remote signaling of fuse link operation. Catalogue numbers structure • SD(size)-D, SD(size)-S: 1-pole • TD(size)-D, TD(size)-DI: 3-pole. Standards / approvals IEC 60269-1 and 2, VDE 0636-1 and 2. • Technical data • Voltage: 690 V a.c. • Current: 160 to 1600A • Rated for fuse links with breaking capacity: 120 kA Compatible fuse links NH 400, 500 and 690 V a.c. NH gG and aM fuse links • Packaging • 1-pole: 3, SD4 and 3-pole: 1 • Packaging 100% recyclable • Complies with IEC 60269-1 and 2 fuse system A (NH base), manufacturers type test certificates of compliance available. • 3-pole integral NH00 base available with reduced width. • Clip-in phase barriers, terminal shrouds and fuse covers available. • Vibration tested to IEC 60068-2-6 for marine use. Accessories Features Fuse base catalogue numbers Catalogue Numbers Size 00 Poles 1-pole 3-pole 1 1-pole 3-pole 1-pole 2 3-pole 3 4 1-pole 3-pole 1-pole Current (Amps) 160 160 160 250 250 400 400 400 400 630 630 1250 1600 DIN-Rail and Screw Mounting SD00-D TD00-D TD00-DI* SD1-D TD1-D SD2-D SD2-DD** TD2-D TD2-DD** SD3-D** TD3-D** N/A N/A Screw Mounting Only SD00-S N/A N/A SD1-S N/A SD2-S N/A N/A N/A SD3-S N/A SD4-S SD4-S1600 Pack Quantity 3 1 1 3 1 3 3 1 1 3 1 1 1 Compatible Fuse Links Size 400/500/690 V NH gG and aM fuse links * 3-pole integral base moulding. ** Double fuse contact clips. Data sheet 10163 EATON Bussmann series NH catalogue 47 NH Fuse bases and accessories - SD and TD series Technical data SD00-D SD1-D TD00-D TD1-D TD00-DI Glass filled PBT Silver plated copper Zinc clear plated steel Fuse Base Catalogue Numbers Base Contacts Screw, nuts and washers Derating temperature factors for maximum current 35°C 40°C 50°C Maximum power acceptance Degree of protection with covers fitted Terminal screw Maximum tightening torque terminal screw DIN-Rail Fixing Screw With microswitch 16A/250V Fuse operated signal SD2-D TD2-D SD3-D TD3-D 1 0.95 0.85 32W IP20 M10 32N•m 1 0.95 0.85 45W IP20 M10 32N•m 1 0.95 0.85 60W IP20 M12 32N•m 1 0.95 0.85 1 0.95 0.85 110W M16 56N•m 145W M16 56N•m Solid links catalogue numbers Size NH00 NH1 NH2 NH3 Current (Amps) 160 250 400 630 Catalogue Numbers SDL-00 SDL-1 SDL-2 SDL-3 Pack Quantity 3 3 3 3 Solid link Accessories Accessories Fuse extraction handle Size NH00-3 Current (Amps) 160 - 630 Catalogue Numbers FEH Pack Quantity 1 Fuse extraction handle Shroud kits Fuse Base Series SD1 SD2 SD3 Fuse size NH1 NH2 NH3 Current (Amps) 250 400 630 Catalogue Numbers SD12-SK SD12-SK SD3-SK Description Kit includes 2 shrouds and 1 fuse cover Shroud kit Data sheet 10163 48 EATON Bussmann series NH catalogue SD4-S1600 1 0.95 0.85 12W IP20 M8 10N•m -20 to 70°C -40 to 80°C Operating temperature range Storage temperature range SD4-S NH Fuse bases and accessories - SD and TD series Phase Barrier Kit Size NH00 NH1 Current (Amps) 160 250 Catalogue Numbers SD00-PB SD12-PB Pack Quantity 1 1 NH2 400 SD12-PB 1 NH3 630 SD3-PB 1 Description 2-Phase barriers 2-Phase barriers and 2 ganging links Phase barrier Ganging link IP Protection Kits Current (Amps) 160 Size NH00 Catalogue Numbers TD00-IP20 Fuse Cover 3 Shroud 6 Phase Barrier 2 Ganging Link 1 TD00-IP20I TD00-IP20IC 250 400 630 TD1-IP20 TD2-IP20 TD3-IP20 3 1 3 6 2 2 Description Triple pole protection kit for TD00-D with shrouds, fuse covers and phase barriers Integral triple pole protection kit for TD00-DI with molded shrouds and phase barriers Integral triple pole protection kit for TD00-DI with fuse covers and molded shrouds and phase barriers Triple pole protection kit with terminal shrouds, fuse cover phase barriers and ganging links Accessories NH1 NH2 NH3 Integral Kit TD00-IP20 TD00-IP20I TD00-IP20IC TD(size 1 to 3)-IP20 Microswitch Catalogue Numbers BVL50 170H0236 170H0238 Pack Quantity 1 12 12 Ratings 6 A 250 V a.c. 2 A 250 V a.c. 2A 250 V a.c. Microswitch suitable for the following NH fuse links: • 400 Volts gG/gL • 500 Volts gG/gL and aM • 690 Volts gG/gL and aM. BVL50 170H0236 Note: Microswitches fit onto the fuse gripping lugs and are applicable to all NH size Bussmann fuses. Data sheet 10163 EATON Bussmann series NH catalogue 49 NH Fuse bases and accessories - SD and TD series Dimensions (mm) 1-pole, size 00 Size NH00 Pole 1-pole A 120 B 102 C 35.5 D 20 E 56 F 24 G 51 H M8x20 I 25 J 8 J 10 10 10 10 K 30 30 30 30 Dimensions (mm) 1-pole, sizes 1, 2 and 3 Accessories Size NH1 NH2 NH3 Poles/Type 1-pole 1 pole 1-pole double clip 1-pole A 199 224 223 239 B 175 199 199 209 Data sheet 10163 50 EATON Bussmann series NH catalogue C 56 56 56 56 D 35 35 35 36 E 79 79 82 82 F 37 37.5 37 37.5 G 78 86 79 88 H M10x25 M10x25 M10x25 M12x30 I 25 25 25 25 NH Fuse bases and accessories - SD and TD series Dimensions (mm) 1-pole, size 4 Size NH4 Poles/Type 1-pole 1250A 1-pole 1600A A 295 295 B 255 255 C 90 90 D 52 60 E 105 105 F 47 50 G 122 125 H M16x40 M16x40 I 30 30 J 14 14 K 40 40 L 150 150 M 92 92 N M12x40 M12x40 Accessories Dimensions (mm) 3-pole, size 00 Size NH00 Poles/Type 3-pole A 120 B 102 C 35.5 D 20 E 56 F 24 G 51 H M8x20 I 25 J 8 K - L 103.5 M 34 N 146 P 89 Data sheet 10163 EATON Bussmann series NH catalogue 51 NH Fuse bases and accessories - SD and TD series Dimensions (mm) integral 3-pole, size 00 Size NH00 Poles/Type 3-pole Integral A 120 B 102 C - D 20 E 56 F 24 G 51 H I M8x20 - J K 7.5x10 63.5 L 97 M 32.3 N 146 P 90 Dimensions (mm) 3-pole, sizes 1, 2 and 3 Accessories Size NH1 NH2 NH3 Poles/Type 3-pole 3-pole 3-pole double clip 3-pole A 199 224 223 239 B 175 199 199 209 C 56 56 56 56 Data sheet 10163 52 EATON Bussmann series NH catalogue D 35 35 35 36 E 79 79 82 82 F 37 37.5 37 37.5 G 78 86 79 88 H M10x25 M10x25 M10x25 M12x30 I 25 25 25 25 J 10 10 10 10 K 30 30 30 30 L 188 188 188 221 M 66 66 66 82.5 N 245 245 245 260 P 125.5 125.5 125.5 137.5 NH Fuse rails - vertical - EBF series Description Bussmann’s range of NH Fuse rails is specifically designed to be used with NH Fuse links. All energized metal parts are fully protected against accidental contact. They are intended for direct installation on horizontal or vertical busbar systems. Functionality • Designed for installation onto 185 mm busbar systems, sizes 00,1,2 and 3 • Fuse rail width: size 00 - 50 mm, size 2,3 - 100 mm • IP20 Touch protection • EBF 00/100 mm fuse rails are designed for installation onto 100 mm busbar systems. Installation onto 185 mm busbar system is possible by using an adaptor Catalogue Numbers structure EBF • Suitable for installation in environments free of any dust, explosive or aggressive gases. • Altitude up to 2000 metre above sea level • Can be used in outdoor environments if they are installed in IP34 cabinets • Relative air humidity should not be higher than 50% temperature of +40oC • Ambient temperature from -25oC to +55oC Standards / approvals • IEC 60269-1 and CE. Technical data • Voltage: 690 V a.c. • Current: • 160 A size 00 • 400 A size 2 • 630 A size 3 Features Compatible fuse links • NH 400, 500 and 690 V NH gG and aM fuse links • Possible installation of various earthing devices • Various options for cable terminations • Wide range of accessories • Touch protection IP20 with fuse shrouds Packaging • 1 per carton. Accessories • Operating conditions Catalogue Numbers Current Busbar Catalogue Size (Amps) system Numbers Vertical fuse rail for NH Size 00 EBF00230S8 100 mm* EBF00230V1 EBF00230V0 00 160 EBF00330S8 185mm EBF00330V1 Pack Quantity Cable Terminals Bridge terminals with bridge clamps (S) 4 - 70 mm2, screw terminals with M8 screws V-Terminals with V-Clamps 25 - 120 SW V Terminals without V-Clamps Bridge terminals with bridge clamps (S) 4 - 70 mm2, screw terminals with M8 screws V-Terminals with V-Clamps 25 - 120 SW V Terminals without V-Clamps EBF00330V0 Vertical fuse rail suitable for NH Size 1 and size 2 fuses V-Terminals with V-Clamps (35 - 240 mm2) EBF2330V1 Screw terminals with pressed nuts M10 (M10 Screw) 2 400 185 mm EBF2330M1 2V-Terminals with double V-Clamps (2 x 50 - 240 mm2) EBF2330W1 Vertical fuse rail suitable for NH Size 3 fuses V-Terminals with V-Clamps (70 - 300 SW) EBF3330V1 Screw terminals with pressed nuts M12 (M12 Screw) 3 630 185 mm EBF3330M1 2V-Terminals with double V-Clamps (2 x 50 - 240 mm2) EBF3330W1 Compatible Fuse Links Weight Size 1 1 kg 1.1 kg 1 kg 1 2 kg 2.2 kg 2 kg 1 3.2 kg 3.1 kg 3.8 kg 1 4 kg 3.1 kg 00 1 and 2 3 4.8 kg * EBF 00 - 100 mm fuse rails are designed for installation onto 100 mm busbar systems. Installation onto a 185 mm busbar system is possible by using an adaptor EATON Bussmann series NH catalogue 53 NH Fuse rails - vertical - EBF series Technical data Type Size Rated thermal current Ith = In Voltage Un Rated insulation voltage UI Rated frequency A V V Hz Rated power dissipation W Rated short-circuit withstand current kA EBF 00 100 mm 00 EBF 00 185 mm 00 EBF 2 2 EBF3 3 160 690 1000 160 690 1000 400 690 1000 630 690 1000 50 - 60 50 - 60 50 - 60 50 - 60 12 100 12 100 45 100 60 100 100 Mechanical durability Number of cycles 100 100 100 Weight IP Degree of protection kg 0.75 2 4.5 5 IP 00 00 201 201 00 00 2 3 Size of fuse links 1 With fuse links shrouds Dimensions (mm) - EBF 00 100 mm busbar system Accessories M8 M Screws S 54 V-Terminals EATON Bussmann series NH catalogue M8 Screws V-Terminals side view side view NH Fuse rails - vertical - EBF series Dimensions (mm) - EBF 00 185 mm busbar system M8 Screws V-Terminals Accessories Dimensions (mm) - EBF 2 and 3 EBF 2 and 3 EBF 2 and 3 With terminals 2V (2 x 240 mm2) EATON Bussmann series NH catalogue 55 NH Fuse switch disconnectors - vertical - EBV series Description Eaton's Bussmann series NH Vertical Gear is specifically designed to be used with NH fuse links. All energized metal parts are fully protected against accidental contact. They are suitable for direct installation on horizontal or vertical busbar systems. The three poles can be switched independently or simultaneously depending upon the version. These are manually operated switches and the making and breaking is dependent on the speed of the operation. The EBV series NH gear are provided complete with the clamps(i.e. screws/V-terminals/2V-terminals) and shrouds for cable termination. Functionality • Designed for installation onto 100 mm or 185 mm busbar system • Making and breaking operation should be done with determined movement Operating conditions • Parrallel moving, double contact system • • Suitable for top cable termination connection Suitable for installation in environments free of any dust, explosive or aggressive gases. • Altitude up to 2000 metre above sea level • Can be used in outdoor environments if they are installed in IP34 cabinets • Relative air humidity should not be higher than 50% temperature of +40oC • Ambient temperature from -25oC to +55oC Catalogue Numbers structure • EBV (see table below) Standards / approvals • IEC 60947-1 and 3, EN 60947-1 and 3 Technical data • Voltage: 690 V a.c. • Current: 160 to 910 A Accessories • Utilisation category: Touch protection IP 30 from the front. • Top/bottom cable termination possibility • Test holes provided on the cover to measure the voltage across the link AC21B 690 V a.c. Size 3 • AC22B 500 V a.c. Sizes 00 to 3 • Various options for cable terminations • AC23B 400 V a.c. Size 00 to 3. • Wide range of accessories NH 400, 500 and 690 V gG and aM fuse links. Busbar mounting options • Size 00 NH gear are available in two versions suitable for installations onto 100 mm busbar and 185 mm busbar system. 100 mm rails can be installed on the 185 mm busbar system by using an adaptor • Sizes 1,2 and 3 are suitable for installation onto 185 mm busbar system 56 • • Compatible fuse links • Features EATON Bussmann series NH catalogue Packaging • 1 per carton. NH Fuse switch disconnectors - vertical - EBV series Catalogue Numbers Current Busbar Catalogue Size (Amps) System Numbers Cable Terminals Vertical fuse switch disconnector for NH Size 00 for 100 mm busbar system - simultaneous 3 phase switching 00 160 100 EBV0023TS8 Bridge terminals with bridge clamps (s) 4-70mm², screw terminals with M8 screws EBV00023TV1 V-terminals with V-clamps 25-120SW 1 1.3 kg Vertical fuse switch disconnector for NH Size 00 for 185 mm busbar system - simultaneous 3 phase switching 00 160 185 EBV0033TS8 Bridge terminals with bridge clamps (s) 4-70 mm2, screw terminals with M8 screws EBV0033TV1 V-terminals with V-clamps 25-120SW EBV0033TV0 V-terminals without V-clamps EBV233SW1 2V-terminals with double clamps 240 mm2 EBV233SV0 V-terminals without V-clamps 00 1.5 kg V-terminals, without V-clamps Vertical fuse switch disconnector for NH Size 00 for 185 mm busbar system - each phase switching separately 00 160 185 EBV0033SS8 Bridge terminals with bridge clamps (s) 4-70 mm², screw terminals with M8 screws EBV0033SV1 V-terminals with V-clamps 25-120SW EBV0033SV0 V-terminals, without V-clamps Vertical fuse switch disconnector for NH Sizes 1 and 2 for 185 mm busbar system - each phase switching separately V-terminals with V-clamps 240 mm2 2 400 185 EBV233SV1 Screw terminals with pressed nuts M10 EBV233SM1 1.3 kg 1 2.8 kg 2.9 kg 2.8 kg 00 1 2.7 kg 2.8 kg 00 2.7 kg 1 5.8 kg 5.7 kg 1 and 2 6.4 kg 5.5 kg EBV233SW0 2V-terminals without double V-clamps Vertical fuse rail suitable for NH Sizes 1 and 2 fuses for 185mm busbar system - simultaneous 3 phase switching V-terminals with V-clamps 240 mm2 2 400 185 EBV233TV1 1 5.8 kg 5.7 kg 6.4 kg 5.5 kg 6.9 kg 1 and 2 Screw terminals with pressed nuts M10 EBV233TM1 2V-terminals with double V-clamps 240 mm2 EBV233TW1 V-terminals without V-clamps EBV233TV0 2V-terminals without double V-clamps EBV233TW0 Vertical fuse rail suitable for NH size 3 fuses for 185mm busbar system - each phase switching separately V-terminals with V-clamps 240 mm2 3 630 185 EBV333SV1 1 6.6 kg 6.5 kg 3 EBV333SM2 Screw terminals with pressed nuts M12 EBV333SW1 2V-terminals with double V-clamps 240mm2 V-terminals without V-clamps EBV333SV0 EBV333SW0 2V-terminals without double V-clamps Vertical fuse rail suitable for NH size 3 fuses for 185 mm busbar system - simultaneous 3 phase switching V-terminals with V-clamps 240 mm2 3 630 185 EBV333TV1 Screw terminals with pressed nuts M12 EBV333TM2 2V-terminals with double V-clamps 240 mm2 EBV333TW1 EBV333TV0 EBV333TW0 V-terminals without V-clamps 2V-terminals without double V-clamps 6.9 kg Accessories EBV0023TV0 Compatible Pack Fuse Links Quantity Weight Size 7.2 kg 6.3 kg 6.7 kg 1 6.6 kg 6.5 kg 3 7.2 kg 6.3 kg 6.7 kg EATON Bussmann series NH catalogue 57 NH Fuse switch disconnectors - vertical - EBV series Technical data Type Rated thermal current with fuse links Ith = In Rated thermal current with solid links Ith Voltage Un Utilisation category Rated switching current Ie Rated short-circuit making current Rated short-circuit withstand current Rated insulation voltage Ui Rated impulse withstand voltage Uimp Rated short time withstand current Icw Rated frequency Mechanical durability Electrical durability IP Rating Fuse links size A EBV 00/ 100 mm 160 EBV 00 160 EBV 2 400 EBV 3 630 A V N/A 690 N/A 690 600 690 750 690 690 V a.c. 500 V a.c. AC-22B N/A AC-22B N/A AC-22B N/A AC-21B AC-22B 400 V a.c. A AC-23B AC-23B AC-23B AC-23B 160 160 400 630 690 V a.c. 500 V a.c. 400 V a.c. 690 V a.c. 25 25 25 100 80 N/A 100 80 100 100 100 100 80 100 100 80 500 V a.c. 100 N/A 100 100 400 V a.c. 100 100 100 100 V kV kA Hz No. of cycles 1000 8 N/A 50/60 1600 1000 12 N/A 50/60 1600 1000 12 122)/ 153) 50/60 1000 1000 12 142)/ 163) 50/60 1000 IP 200 30 00 200 20 00 200 30 1, 2 200 30 3 1: fuse link gTr 630 kVA, DIN 43620, VDE 0636/2011 voltage 2 For disconnectors 1-phase disconnected 3: For disonnectors 3-phase disconnectors Dimensions (mm) - EBV 00 100 mm EBV 00 (each phase switching separately) [ [ Accessories M8 Screws 58 M10 Screws EATON Bussmann series NH catalogue NH Fuse switch disconnectors - vertical - EBV series Dimensions (mm) - EBV 00 (Three phase switching simultaneously) [ Dimensions (mm) - EBV 2 (Each phase switching separately) Accessories M12 Screws V-Terminals EATON Bussmann series NH catalogue 59 NH Fuse switch disconnectors - vertical - EBV series Dimensions (mm) - EBV 2 (Three phase switching simultaneously) M12 Screws V-Terminals Dimensions (mm) - EBV 3 (One phase) Accessories M12 Screws 60 EATON Bussmann series NH catalogue V-Terminals NH Fuse switch disconnectors - vertical - EBV series Dimensions (mm) - EBV 3 (Three phase) M12 Screws V-Terminals Accessories EATON Bussmann series NH catalogue 61 NH Fuse switch disconnectors - horizontal - EBH000 Description Bussmann’s range of EBH000 NH Horizontal Gear is specifically designed to be used with size 000 NH Fuse links up to 160 A. They have compact dimensions, all energized metal parts are fully protected against accidental contact. These are manually operated switches and the making and breaking is dependent on the speed of the operation. Functionality • Designed for installation onto mounting platess, 60 mm or 100 mm busbar systems • Making and breaking operation should be done with determined movement • Parallel moving, double contact system • Suitable for top or bottom cable terminal connection Catalogue numbers structure • EBH000 O on mounting plates • EBH000 1 on 60 mm busbar systems Operating conditions • Suitable for installation in environments free of any dust, explosive or aggressive gases • Altitude up to 2000 metres above sea level • Can be used in outdoor environments if they are installed in IP34 cabinets • Relative air humidity should not be higher than 50% temperature of +40oC • Ambient temperature from -25oC to +55oC Standards/approvals • IEC 60947-1 and 3, EN 60947-1 and 3 Technical data • Voltage: 690 V a.c. • Current: 160 A Features Utilisation category: • Touch for IP 30 from the front AC21B • Top/bottom cable termination possibility AC22B • Compact dimensions • AC23B • • DC21B Test holes provided on the cover to measure the voltage across the link • Various options for cable terminations • Wide range of accessories) • • • Accessories Compatible fuse links • Size 000 NH Fuse links up to 160 A Mounting options • On mounting plates: EBH000 O • On to 60 mm busbar systems: EBH000 1 62 EATON Bussmann series NH catalogue Packaging • 1 per carton. NH Fuse switch disconnectors - horizontal - EBH000 Catalogue Numbers Current Busbar Catalogue Size (Amps) System Numbers Cable Terminals Horizontal fuse switch disconnector for NH size 000 up to 160 A for installation on mounting plates for connection of round conductors - S-bridge clamps 000 160 N/A EBH000O3TS5 EBH000O3TS5-D Pack Quantity Compatible Fuse Links Size 1 000 up to 160 A for connection of round conductors - S-bridge clamps, option to install on DIN rail for connection of round conductors with lug terminals - M8 screws EBH000O3TM8-D for connection of round conductors with lug terminals - M8 screws, option to install on DIN rail EBH000O3TS5L for connection of round conductors - S-bridge clamps, lengthened terminal shrouds EBH000O3TM8L for connection of round conductors with lug terminals - M8 screws, lengthened terminal shrouds Horizontal fuse switch disconnector for NH size 000 up to 160 A for installation on 60 mm busbar 000 160 60 mm EBH00013TBS5 Cable terminal – bottom, for connection of round conductors - S-bridge clamps EBH000O3TM8 EBH00013TTS5 EBH00013TBM8 EBH00013TTM8 Cable terminal – top, for connection of round conductors - S-bridge clamps Cable terminal – bottom, for connection of conductors with lug terminals - M8 screws Cable terminal – top, for connection of conductors with lug terminals - M8 screws 000 up to 160 A 1 Technical data Utilisation category Rated switching current Ie Rated switching Voltage Ue Rated short circuit making current Rated short-circuit withstand current Rated insulation voltage Ui Rated power dissipation Rated impulse withstand voltage Uimp Rated frequency Mechanical durability Electrical durability IP Rating Fuse links size DIN-Rail A V 690 V EBH 000 160 690 AC-23B AC-22B AC-22B 160 100 100 400 690 400 100 100 100 690 V V 25 1000 25 1000 25 1000 25 1000 25 1000 W kV Hz Nb of cycles Nb of cycles 12 8 50-60 12 8 50-60 12 8 50-60 12 8 50-60 12 8 50-60 2000 300 IP20 000 2000 300 IP20 000 2000 300 IP20 000 2000 300 IP20 000 2000 300 IP20 000 A V Mounting plates AC-21B DC-21B 160 160 250 690 100 100 Accessories Rated thermal current with solid links Ith Voltage Un Busbar EATON Bussmann series NH catalogue 63 NH Fuse switch disconnectors - horizontal - EBH000 Dimensions (mm) - EBH000 On mounting plates Accessories With extended terminal shrouds Dimensions and spacing of holes for installation on EBH000 O on mounting plates 64 EATON Bussmann series NH catalogue NH Fuse switch disconnectors - horizontal - EBH000 Dimensions (mm) - EBH000 (60 mm busbar mounting) JUXERĞüV]\Q\PP Bottom cable terminal Accessories JUXERĞüV]\Q\PP Top cable terminal EATON Bussmann series NH catalogue 65 NH Fuse switch disconnectors - horizontal - EBH00 to 4 Description Eatons' Bussmann series NH horizontal fuse switch disconnectors are specifically designed to be used with NH fuse links. All energised metal parts are fully protected against accidental contact. These are manually operated switches and the making and breaking is dependent on the speed of the operation. The EBV series NH gear are provided complete with the clamps (i.e. screws/V-terminals/2V-terminals) and cable for shrouds for cable termination. Functionality • Designed for installation onto mounting platess, 60 mm or 100 mm busbar systems • Making and breaking operation should be done with determined movement • Parallel moving, double contact system Operating conditions • Suitable for top or bottom cable terminal connection • Suitable for installation in environments free of any dust, explosive or aggressive gases • Altitude up to 2000 metre above sea level • Can be used in outdoor environments if they are installed in IP34 cabinets • Relative air humidity should not be higher than 50% temperature of +40oC • Ambient temperature from -25oC to +55oC Catalogue Numbers structure • EBH (see catalogue numbers table) Standards/approvals • IEC 60947-1 and 3, EN 60947-1 and 3 Technical data • Voltage: 400, 500 and 690 V a.c. • Current: 160 to 1600 A • Utilisation category: Touch for IP 30 from the front • Top/bottom cable termination possibility • Test holes provided on the cover to measure the voltage across the link Accessories AC21B Size 4 • AC22B Sizes 00 (V 120), 1-S, 3, 4 • AC23B Sizes 00 to 2 • Various options for cable terminations • DC21B Sizes 00, 2 and 3 • Wide range of accessories) • DC21B Sizes 00, 1 and 2 NH 400, 500 and 690 V NH gG and aM fuse links Mounting options • • • Compatible fuse links • Features On mounting plates • EBH00 O, EBH1 O, EBH2 O, EBH3 O On to busbar systems • • 60 mm busbar systems: EBH00 1, EBH1 1, EBH2 1 installation on to busbar system with hooked clamps • 100 mm busbar systems: EBH2 2, EBH1 2 installation on to busbar system with hooked clamps 66 EATON Bussmann series NH catalogue Packaging • 1 per carton. NH Fuse switch disconnectors - horizontal - EBH00 to 4 Catalogue Numbers Current Busbar Catalogue Size (Amps) System Numbers Cable Terminals Horizontal fuse switch disconnector for NH size 00 for installation on mounting plates For connection of round conductors 00 160 N/A EBH00O3TS5 EBH00O3TM8 EBH00O3TV1 For connection of conductors with lug terminals For connection of sector-shaped conductors EBH00O3TS5L For connection of round conductors, lenghtened terminal shrouds Pack Quantity Compatible Fuse Links Size 1 00 1 00 1 1 1 1 1 1 1 2 1 2 EBH00O3TM8L For connection of conductors with lug terminals, lenghtened terminal shrouds EBHOO03TV1L For connection of sector-shaped conductors, lengthened terminal shrouds Horizontal fuse switch disconnector for NH size 00 for installation on 60 mm busbar 00 160 60 mm EBH0013TBM8 Cable terminal - bottom, for connection of conductors with lug terminals EBH0013TTM8 Cable terminal - top, for connection of conductors with lug terminals EBH0013TBF EBH0013TTF Cable terminal - top, for connection of conductors with bare ends Cable terminal - bottom, for connection of conductors with bare ends frame clamps Horizontal fuse switch disconnector for NH size 1 for installation on mounting plates For connection of round conductors - S-bridge clamps 1 250 N/A EBH1O3TS8 For connection of conductors with lug terminals - screws EBH1O3TM1 EBH1O3TV1 For connection of sector-shaped conductors V-clamps For connection of round conductors, top terminals, V-terminals, bottom terminals, S-bridge terminals For connection of round conductors, top terminals, V-terminals, bottom terminals, EBH1O3TVM screw terminals For connection of round conductors, top terminals, S-bridge terminals, bottom EBH1O3TSV terminals, V-terminals For connection of round conductors, top terminal, screw terminals, bottom terminals, EBH1O3TMV V-terminals Horizontal fuse switch disconnector for NH size 1 for installation on 60 mm busbar Top cable terminals, for connection of round conductors, S-bridge clamps 1 250 60 mm EBH113TTS8 EBH1O3TVS Bottom cable terminals, for connection of round conductors, S-bridge clamps Bottom cable terminals, for connection of conductors with lug terminals - screws Top cable terminals, for connection of sector-shaped conductors - V-clamps Bottom cable terminals for connection of sector-shaped conductors - V-clamps EBH113TBM1 EBH113TTV1 EBH113TBV1 Horizontal fuse switch disconnector for NH size 1 for installation on 100 mm busbar Top cable terminals, for connection of round conductors 1 250 100 mm EBH123TTS8 Bottom cable terminals, for connection of round conductors - S-bridge clamps EBH123TBS8 EBH123TTM1 Top cable terminals, for connection of conductors, with lug terminals - screws EBH123TBM1 Bottom cable terminals, for connection of conductors, with lug terminals - screws Top cable terminals, for connection of sector shaped conductors - V-clamps EBH123TTV1 Bottom cable terminals for connection EBH123TBV1 Horizontal fuse switch disconnector for NH size 2 for installation on mounting plates For connection of round conductors - S-bridge clamps 2 400 N/A EBH2O3TS8 For connection of conductors with lug terminals - M10 screws EBH2O3TM1 For connection of sector-shaped conductors - V-clamps EBH2O3TV1 For connection of sector-shaped conductors - double V-clamps EBH2O3TW1 Horizontal fuse switch disconnect for NH size 2 for installation on 60 mm busbar 2 400 60 EBH213TBM1 Bottom cable terminals, for connection of conductors with lug terminals, M10 screws EBH213TTM1 Top cable terminals, for connection of conductors with lug terminals, M10 screws Bottom cable terminals, for connection of sector-shaped conductors, V-clamps EBH213TBV1 Top cable terminals, for connection of sector shaped conductors, V-clamps EBH213TTV1 EBH213TBW1 Bottom cable terminals, for connection of sector shaped conductors, double V-clamps EBH213TTW1 Top cable terminals, for connection of sector shaped conductors, double V-clamps Accessories EBH113TBS8 1: Please contact Bussmann to discuss specific requirements EATON Bussmann series NH catalogue 67 NH Fuse switch disconnectors - horizontal - EBH00 to 4 Catalogue Numbers Current Busbar Catalogue Size (Amps) System Numbers Cable Terminals Horizontal fuse switch disconnector for NH size 2 for installation on 100 mm busbar Bottom cable terminals, for connection of conductors with lug terminals, M10 screws 2 400 100 mm EBH223TBM1 Top cable terminals, for connection of conductors with lug terminals, M10 screws EBH223TTM1 Pack Quantity Compatible Fuse Links Size 1 2 1 3 1 3 1 4 Bottom cable terminals, for connection of sector shaped conductors , V-clamps EBH223TBV1 EBH223TTV1 Top cable terminals, for connection of sector shaped conductors, V-clamps Bottom cable terminals, for connection of sector shaped conductors, double V-clamps Top cable terminals, for connection of sector shaped conductors, double V-clamps EBH223TBW1 EBH223TTW1 Horizontal fuse switch disconnector for NH size 3 for installation on mounting plates For connection of round conductors, S-bridge clamps 3 630 N/A EBH3O3TS8 For connection of conductors with lug terminals, M12 screws EBH3O3TM2 Horizontal fuse switch disconnector for NH size 3 for installation on 60 mm busbar 3 630 60 mm EBH313TM2 For installation on to 60 mm busbar system, top/bottom cable terminals, M12 screws Horizontal fuse switch disconnector for NH size 4 for installation on mounting plates 4a 1250 N/A EBH403TM2-12 Three phase switching simultaneously 1600 EBH403TM2-16 Three phase switching simultaneously 1250 EBH403SM2-12 Each phase switching simultaneously 1600 EBH403SM2-16 Each phase switching simultaneously Technical data - sizes 00, 1 and 2 Rated thermal current with solid links Ith Voltage Un Utilisation category Rated switching current Ie Accessories Rated switching Voltage Ue Rated short circuit making current Rated short-circuit withstand current Rated insulation voltage Ui Rated power dissipation Rated impulse withstand voltage Uimp Rated frequency Mechanical durability Electrical durability IP Rating Weight Fuse links size 68 A V A V 690 V 400 V 690 V 400 V V W kV Hz No of cycles IP kg EBH 1 250 690 AC-23B DC-21B DC-22B 160 160 160 250 440 690 20 20 80 20 20 100 20 20 80 AC-23B AC-22B DC-22B AC-23B DC-21B 400 400 250 250 250 440 690 250 690 400 15 80 25 80 80 15 100 25 100 100 100 1000 12 8 50-60 1600 200 20 0.7, 0.9 00 EATON Bussmann series NH catalogue EBH 2 400 690 EBH 00 160 690 20 N/A 20 N/A 80 80 25 80 100 1000 100 25 100 1000 32 8 50-60 1600 200 30 2.5 1 50-60 N/A 45 12 50-60 1000 200 20 3 / 4.5 2 N/A DC-22B 400 220 20 20 N/A NH Fuse switch disconnectors - horizontal - EBH00 to 4 Technical data - sizes 3 and 4a Rated thermal current with solid links Ith Voltage Un Utilisation category Rated switching current Ie Rated switching Voltage Ue Rated short circuit making current Rated short-circuit withstand current Rated insulation voltage Ui Rated power dissipation Rated impulse withstand voltage Uimp Rated frequency Mechanical durability Electrical durability IP Rating Weight Fuse links size A V A V 690 V 400 V 690 V 400 V V W kV Hz No of cycles IP kg EBH 3 630 690 AC-22B 630 690 100 100 DC-21B 630 250 100 100 EBH4a 1250 500 1600 400 AC-22B 1250 500 AC-21B 1600 400 25 50 800 25 1000 60 12 50-60 N/A 8 50-60 1000 200 20 5 / 5.9 3 4a Accessories Dimensions (mm) for EBH00 suitable for installation on mounting plates Without extended terminals With extended terminals Dimensions and spacing holes for installation on mounting plates EATON Bussmann series NH catalogue 69 NH Fuse switch disconnectors - horizontal - EBH00 to 4 Dimensions (mm) for EBH1 suitable for installation on mounting platess ě Screw terminals Accessories ě V Clamps Dimensions and spacing holes for installation on mounting platess 70 EATON Bussmann series NH catalogue NH Fuse switch disconnectors - horizontal - EBH00 to 4 Dimensions (mm) for EBH1 suitable for installation on 60 mm busbar ě Dimensions (mm) for EBH1 suitable for installation on 100 mm busbar Accessories ě EATON Bussmann series NH catalogue 71 NH Fuse switch disconnectors - horizontal - EBH00 to 4 Dimensions (mm) for EBH2 suitable for installation on mounting platess Screw Terminals Accessories V Terminals Dimensions and spacing holes for installation on mounting platess 72 EATON Bussmann series NH catalogue NH Fuse switch disconnectors - horizontal - EBH00 to 4 Dimensions (mm) for EBH2 suitable for installation on 60 mm busbar Dimensions (mm) for EBH2 suitable for installation on 100 mm busbar Accessories EATON Bussmann series NH catalogue 73 NH Fuse switch disconnectors - horizontal - EBH00 to 4 Dimensions (mm) for EBH3 Dimensions (mm) for EBH4 Accessories 74 EATON Bussmann series NH catalogue Index - by catalogue numbers Catalogue number Size Voltage Class Type 170H0236 N/A 250 N/A Microswitch Page 49 170H0238 N/A 250 N/A Microswitch 49 BVL50 N/A 250 N/A Microswitch EBF 00 to 3 690 N/A NH Fuse rails - vertical EBH00 to 4 00 to 4 400, 500, 690 N/A NH Fuse disconnector - horizontal 66-74 EBH000 000 690 N/A NH Fuse disconnector - horizontal 62-65 EBV N/A 690 N/A NH Fuse disconnector - vertical 56-61 FEH N/A N/A N/A Fuse extraction handle 48 NHG000B 000 500 gG/gL NH Fuse - Metal 22 NHG000B-400 000 400 gG/gL NH Fuse - Metal 14 NHG000B-690 000 690 gG/gL NH Fuse - Metal 34 NHG000BI 000 500 gG/gL NH Fuse - IMGL 22 NHG000BI-400 000 400 gG/gL NH Fuse - IMGL 14 49 53-55 NHG00B 00 500 gG/gL NH Fuse - Metal 23 NHG00B-400 00 400 gG/gL NH Fuse - IMGL 15 NHG00B-690 00 690 gG/gL NH Fuse - Metal 35 NHG00BI 00 500 gG/gL NH Fuse - IMGL 23 NHG00BI-400 00 400 gG/gL NH Fuse - IMGL 15 NHG01B 01 500 gG/gL NH Fuse - Metal 25 NHG01B-400 01 400 gG/gL NH Fuse - Metal 16 NHG01BI 01 500 gG/gL NH Fuse - IMGL 25 NHG01BI-400 01 400 gG/gL NH Fuse - IMGL 16 NHG02B 02 500 gG/gL NH Fuse - Metal 27 NHG02B-400 02 400 gG/gL NH Fuse - Metal 17 NHG02BI 02 500 gG/gL NH Fuse - IMGL 27 NHG02BI-400 02 400 gG/gL NH Fuse - IMGL 17 NHG03B 03 500 gG/gL NH Fuse - Metal 29 NHG03B-400 03 400 gG/gL NH Fuse - Metal 18 NHG03BI 03 500 gG/gL NH Fuse - IMGL 29 NHG03BI-400 03 400 gG/gL NH Fuse - IMGL 18 NHG0B 0 500 gG/gL NH Fuse - Metal 24 NHG1B 1 500 gG/gL NH Fuse - Metal 26 NHG1B-400 1 400 gG/gL NH Fuse - Metal 16 NHG1B-690 1 690 gG/gL NH Fuse - Metal 36 NHG1BI 1 500 gG/gL NH Fuse - IMGL 26 NHG1BI-400 1 400 gG/gL NH Fuse - IMGL 16 NHG2B 2 500 gG/gL NH Fuse - Metal 28 NHG2B-400 2 400 gG/gL NH Fuse - Metal 17 NHG2B-690 2 690 gG/gL NH Fuse - Metal 37 NHG2BI 2 500 gG/gL NH Fuse - IMGL 28 NHG2BI-400 2 400 gG/gL NH Fuse - IMGL 17 NHG3B 3 500 gG/gL NH Fuse - Metal 30 NHG3B-400 3 400 gG/gL NH Fuse - Metal 18 NHG3B-690 3 690 gG/gL NH Fuse - Metal 38 NHG3BI-400 3 400 gG/gL NH Fuse - IMGL 18 NHG4B-690 4 690 gG/gL NH Fuse - Metal 39 NHG4G 4 500 gG/gL NH Fuse - Metal 31 NHM000B 000 500 aM NH Fuse - Metal 42 NHM000B-690 000 690 aM NH Fuse - Metal 42 NHM00B 00 500 aM NH Fuse - Metal 43 NHM00B-690 00 690 aM NH Fuse - Metal 43 NHM1B 1 500 aM NH Fuse - Metal 44 NHM1B-690 1 690 aM NH Fuse - Metal 44 NHM2B 2 500 aM NH Fuse - Metal 45 NHM2B-690 2 690 aM NH Fuse - Metal 45 NHM3B 3 500 aM NH Fuse - Metal 46 NHM3B-690 3 690 aM NH Fuse - Metal SD-D 1-pole 690 N/A NH Base SDL N/A N/A N/A Solid link 48 SD-PB N/A N/A N/A Phase barrier kit 49 SD-S 1-pole 690 N/A NH Base SD-SK N/A N/A N/A Shroud kit TD-D 3-pole 690 N/A NH Base TD-IP20 N/A N/A N/A IP20 Protection kit 46 47-52 47-52 48 47-52 49 IMGL: Insulated Metal Gripping Lugs EATON Bussmann series NH catalogue 75 Index - by size Size Voltage Catalogue number Class Type 0 500 NHG0B gG/gL NH Fuse - Metal 24 00 400 NHG00B-400 gG/gL NH Fuse - IMGL 15 00 400 NHG00BI-400 gG/gL NH Fuse - IMGL 15 00 500 NHG00B gG/gL NH Fuse - Metal 23 00 500 NHG00BI gG/gL NH Fuse - IMGL 23 00 500 NHM00B aM NH Fuse - Metal 43 00 690 NHG00B-690 gG/gL NH Fuse - Metal 35 00 690 NHM00B-690 aM NH Fuse - Metal 43 00 to 3 690 EBF N/A NH Fuse rails - vertical 53-55 00 to 4 400, 500, 690 EBH00 to 4 N/A NH Fuse disconnector - horizontal 66-74 000 400 NHG000B-400 gG/gL NH Fuse - Metal 14 000 400 NHG000BI-400 gG/gL NH Fuse - IMGL 14 000 500 NHG000B gG/gL NH Fuse - Metal 22 000 500 NHG000BI gG/gL NH Fuse - IMGL 22 000 500 NHM000B aM NH Fuse - Metal 000 690 EBH000 N/A NH Fuse disconnector - horizontal 000 690 NHG000B-690 gG/gL NH Fuse - Metal 34 000 690 NHM000B-690 aM NH Fuse - Metal 42 01 400 NHG01B-400 gG/gL NH Fuse - Metal 16 01 400 NHG01BI-400 gG/gL NH Fuse - IMGL 16 01 500 NHG01B gG/gL NH Fuse - Metal 25 01 500 NHG01BI gG/gL NH Fuse - IMGL 25 02 400 NHG02B-400 gG/gL NH Fuse - Metal 17 02 400 NHG02BI-400 gG/gL NH Fuse - IMGL 17 02 500 NHG02B gG/gL NH Fuse - Metal 27 02 500 NHG02BI gG/gL NH Fuse - IMGL 27 03 400 NHG03B-400 gG/gL NH Fuse - Metal 18 03 400 NHG03BI-400 gG/gL NH Fuse - IMGL 18 03 500 NHG03B gG/gL NH Fuse - Metal 29 03 500 NHG03BI gG/gL NH Fuse - IMGL 29 1 400 NHG1B-400 gG/gL NH Fuse - Metal 16 1 400 NHG1BI-400 gG/gL NH Fuse - IMGL 16 1 500 NHG1B gG/gL NH Fuse - Metal 26 1 500 NHG1BI gG/gL NH Fuse - IMGL 26 1 500 NHM1B aM NH Fuse - Metal 44 1 690 NHG1B-690 gG/gL NH Fuse - Metal 36 1 690 NHM1B-690 aM NH Fuse - Metal 1-pole 690 SD-D N/A NH Base 47-52 1-pole 690 SD-S N/A NH Base 47-52 2 400 NHG2B-400 gG/gL NH Fuse - Metal 17 2 400 NHG2BI-400 gG/gL NH Fuse - IMGL 17 2 500 NHG2B gG/gL NH Fuse - Metal 28 2 500 NHG2BI gG/gL NH Fuse - IMGL 28 2 500 NHM2B aM NH Fuse - Metal 45 2 690 NHG2B-690 gG/gL NH Fuse - Metal 37 2 690 NHM2B-690 aM NH Fuse - Metal 45 3 400 NHG3B-400 gG/gL NH Fuse - Metal 18 3 400 NHG3BI-400 gG/gL NH Fuse - IMGL 18 3 500 NHG3B gG/gL NH Fuse - Metal 30 3 500 NHM3B aM NH Fuse - Metal 46 3 690 NHG3B-690 gG/gL NH Fuse - Metal 38 3 690 NHM3B-690 aM NH Fuse - Metal 3-pole 690 TD-D N/A NH Base 4 500 NHG4G gG/gL NH Fuse - Metal 4 690 NHG4B-690 gG/gL NH Fuse - Metal 39 N/A 250 170H0236 N/A Microswitch 49 N/A 250 170H0238 N/A Microswitch 49 N/A 250 BVL50 N/A Microswitch N/A 690 EBV N/A NH Fuse disconnector - vertical N/A N/A FEH N/A Fuse extraction handle 48 N/A N/A SDL N/A Solid link 48 N/A N/A SD-PB N/A Phase barrier kit 49 N/A N/A SD-SK N/A Shroud kit 48 N/A N/A TD-IP20 N/A IP20 Protection kit 49 76 EATON Bussmann series NH catalogue Page 42 62-65 44 46 47-52 31 49 56-61 IMGL: Insulated Metal Gripping Lugs Notes EATON Bussmann series NH catalogue 77 Notes 78 EATON Bussmann series NH catalogue Customer satisfaction team Bussmann’s Customer Satisfaction Team is available to answer questions regarding Bussmann products. Europe calls can be made between: Monday - Thursday 7.30 a.m. - 5.30 p.m. GMT Friday 7.30 a.m. - 5.00 p.m. GMT The Customer Service Satisfaction Team can be reached via: Phone: 00 44 (0) 1509 882 600 Fax: 00 44 (0) 1509 882 786 Email: [email protected] 'My Eaton' customer center 'My eaton' portal supports the following Divisions: B-Line, Bussmann, Crouse-Hinds, Cooper Lighting, Cooper Power Systems, Cooper Safety, and Cooper Wiring Devices. Get started today at www.my.eaton.com by clicking ‘Request User ID and Password’. • Easy to Navigate • Simple to Use • Real-Time Data. Online resources Visit www.bussmann.com for the following resources: • Product cross reference • Product profiles • Online catalogues for the latest United States and European catalogues. Application engineering Application Engineering assistance is available to all customers. The Application Engineering team is staffed by university-qualified electrical engineers who are available with technical and application support. Europe calls can be made between: Monday - Thursday 8.30 a.m. - 4.30 p.m. GMT Friday 8.30 a.m. - 4.00 p.m. GMT Application Engineering can be reached via: Phone: 00 44 (0) 1509 882 699 Fax: 00 44 (0) 1509 882 794 Email: [email protected] EATON Bussmann series NH catalogue 79 At Eaton, we’re energized by the challenge of powering a world that demands more. With over 100 years experience in electrical power management, we have the expertise to see beyond today. From groundbreaking products to turnkey design and engineering services, critical industries around the globe count on Eaton. We power businesses with reliable, efficient and safe electrical power management solutions. Combined with our personal service, support and bold thinking, we are answering tomorrow’s needs today. Follow the charge with Eaton. Visit eaton.com/electrical. Contact your local Eaton office Electrical Sector Eaton’s Bussmann business Melton Road Burton-on-the-Wolds LE12 5TH Leicestershire United Kingdom [email protected] www.bussmann.com Eaton Industries Manufacturing GmbH Electrical Sector EMEA Route de la Longeraie 71110 Morges, Switzerland Eaton.eu © 2014 Eaton All Rights Reserved Printed in the United Kingdom Publication No. CA132004EN November 2014 Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations. Eaton is a registered trademark. All other trademarks are property of their respective owners.