AZPRD

AZPRD
50 AMP HEAVY DUTY
POWER RELAY
FEATURES
•
•
•
•
•
•
SPST, DPST, SPDT, and DPDT versions available
AC and DC coils available
UL Class F (155°C) molded construction
PRD, PRDD and PRDE are UL and cUL Listed
PRDS, PRDQ, and PRDR are UL cUR Recognized
UL, CUL file E44211
CONTACTS
Arrangement
Ratings
UL, CUR
SPST ( 1 Form A & B), SPST-NO-DM ( Form 1X),
SPST-NC-DB (Form 1Y), DPST ( 2 Form A & B ),
SPDT ( 1 Form C), DPDT ( 2 Form C)
Max. switched power: 840W or 12000 VA Res. Load
Max. switched current: 30A
Max. switched voltage: 600 VAC, 28 VDC
30A at 240 VAC Res. [1][2][3]
1.5 HP at 120; 240 VAC [1][2][3]
2.0 HP at 240; 277; 600 VAC [1][2][3]
3600W at 120 VAC / 240 VAC ballast [1][2][3]
30A at 240 VAC Res., 100k cycles [1][2][3]
20A at 600 VAC Res. [1][2][3]
30A at 28 VDC Res.[1][2][3]
Aux. Snap Switch 1/4HP at 125 VAC / 240 VAC [2]
20A at 125 VDC [3]
50A at 277 VAC Res., [4][5]
40A at 277 VAC General use (inductive) [4][5]
GENERAL DATA
Life Expectancy
Mechanical
Electrical
Minimum operations
1 x 107
1 x 105 at 30A 240 VAC Res.
Operate Time (typical)
30 msec at nominal coil voltage
Release Time (typical)
30 msec at nominal coil voltage
(without suppression)
Dielectric Strength
2200 Vrms contact to contact
2200 Vrms contact to coil
(at sea level for 1 min.)
Insulation Resistance
100 megohms min. at 20°C, 500 VDC
50% RH
Dropout
DC: > 10% of nominal coil voltage
AC: > 20% of nominal coil voltage
Ambient Temperature
Operating
PRDQ series [1], PRDS [2]. PRDD [3], PRDE [4], PRDR [5]
Material
Resistance
Silver cadmium oxide
< 50 milliohms initially
(24V, 1A voltage drop method)
Weight
-45°C
-45°C
-45°C
-45°C
(-49°F)
(-49°F)
(-49°F)
(-49°F)
to
to
to
to
80°C (176°F) AC coil, 30A
70°C (239°F) AC coil, 50A
115°C (176°F) DC coil, 30A
105°C (239°F) DC coil, 50A
227 grams
COIL
Power
At Pickup Voltage
(typical)
DC: 1.12W
AC: 6.9 VA
Max. Continuous
Dissipation
DC: 3.3W at 25°C
AC: 12.5 VA at 25°C
Temperature Rise
70°C at nominal coil voltage (AC)
35°C at nominal coil voltage (DC)
NOTES
1. All values at 25°C (77°F).
2. Relay may pull in with less than “Must Operate” value.
3. Specifications subject to change without notice.
Max. Temperature
155°C (311°F)
8/31/15w
AZPRD
RELAY ORDERING DATA
COIL SPECIFICATIONS – DC Coil
Nominal Current
mA ± 10%
333
Coil Resistance
± 10%
18
ORDER NUMBER*
Nominal Coil
VDC
6
Must Operate
VDC
4.50
Max. Continuous
VDC
7.8
12
9.1
15.4
166
72
AZPRD–1C–12D
24
18.0
32.0
83
290
AZPRD–1C–24D
48
36.0
62.6
42
1150
AZPRD–1C–48D
110
82.5
143.0
18.2
6050
AZPRD–1C–110D
AZPRD–1C–6D
COIL SPECIFICATIONS – AC Coil 50/60 Hz
Nominal Coil
VAC
6
Must Operate
VAC
5.1
Max. Continuous
VAC
6.9
Nominal Coil
Power VA
9.5
12
10.2
13.8
9.5
Coil Resistance
± 10%
0.85
2.85
ORDER NUMBER*
AZPRD–1C–6A
AZPRD–1C–12A
24
20.4
27.6
9.5
11.5
AZPRD–1C–24A
120
102.0
138.0
9.5
295.0
AZPRD–1C–120A
240
204.0
276.0
9.5
1170.0
AZPRD–1C–240A
480
408.0
552.0
9.5
4860.0
AZPRD–1C–480A
*For double pole version replace “-1C” with “-2C”, “-2A”, or “-2B”. For SPST replace “-1C” with “-1A” or “-1B”. For SPST-NO-DM replace “-1C” with “-1X”(Short
Base). For SPST-NC-DB replace “-1C” with “-1Y”(Long Base). For addition of SPDT Auxiliary Snap Switch Rated at 10A and 1/4 H.P. add “S” after PRD. For
Q.C. 0.250” terminals add “Q” after PRD. For blow out magnets used in high dc loads add “D” after PRD. For 50A rating with box lug termination add “E” after
PRD. For 50A rating with screw termination add “R” after PRD.
8/31/15w
AZPRD
MECHANICAL DATA
1 Form C
2 Form C
WIRING DIAGRAM
8
6
6
4
4
7
7
5
1 Form C
2 Form C
2
1
2
1
2
1
3
3
3
2
1
5
5
5
3
1 Form A
2 Form A
8
4
7
7
1
2 Form B
2
6
3
3
2
1
1 Form B
8
5
2
1
Form 1X
7
2
1
Form 1Y
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
8/31/15w