led display power supply series

ECU
_
POWER SUPPLY
Mounted Power Supply Series
PFC Power Supply Series
Din-Rail Power Supply Series
Open-Frame Power Supply Series
Industry-Specific Power Supply
(IN) +15i
ECU Electronics Industrial Co. Ltd was established in 1992, which was invested by NO. 38
Research Institute of China Electronics Technology Group Corp. ECU has been qualified
1509001, 15014001, OHSAS18001, GJB9001 system certifications. Many of our products
have obtained international certifications such as CQC, CCC, CB, UL, GSA, CE, TUV etc.
Series of industrial power supply we manufactured are exported worldwide.
CE CB
VEMA
nEUR
DE7,41
c
us
cimus
All ECU Power Supplies are ROHS compliant.
1S014001 OHSAS18001 1S09001 GJB9001
Contents
Mounted Power Supply
EPA Series
15W, 25W, 35W, 50W, 75W, 100W, 150W
02-08
ESP Series
60W, 100W, 200W, 250W, 350W
09 - 13
Security ESP Series
20W(A), 42W(A), 70W(A), 20W, 42W, 70W, 140W
14-20
PFC Power Supply
ESF Series
75W, 100W, 150W, 200W
21-24
ESFG Series
350W
25
Din-Rail Power Supply
EDA Series _
45W, 75W„ 120W, 240W, 480W
26-30
EDR Series
10W, 30W, 60W„ 100W
31-34
Open-Frame Power Supply
OP Series
10-30W, 30-60W, 12W, 50W, 60W
35-39
Industry-Specific Power Supply
Communication Power Supply Series
FOP Series
350W, 500W, 700W
40-42
LED Display Power Supply Series
OP Series
25W, 40W
43
LCD Inverter Power Supply Series
EINV Series
01, 02, 04, 06
44
Power Industry Series
OP Series
15D, 181
45-46
Special Industry Series
EUP Series
47
200W
LED Driver Series
Constant cutrent / Constant current+Constant voltage
New announced product for sale
48
OUNTED POWER SUPPLY
EPR Series
15W
15W
taiiht,Ti
Single Output
Size (L*W*H)
78mm x 51mm x 28mm
2-1451
Be.
Ta 5
Product features
Universal AC input! full range
Power on indication
IA 11 f: Ma! VITO D 1 I Welril
Protections: Overload / Short circuit
Compact. High efficiency. High reliability
100% full load burn-in test
2 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
88-264VAC, 124-370VDC
47-63Hz
30A@230VAC full load cold start
20ms@230VAC full load
110%-180% auto-recovery
-20-70t (refer to output derating curve)
UL60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, 1min
I/P-FG: 1.5kVAC. 1min
0/P-FG: 0.5kVAC, 1min
Weight
0.16kg/pcs
Tol.
R&N
Effi.
Load Regulation
DC adjustment range
_—■■■•■■••1■ 1M■
11
EPR-15-5
5V, 3A
±3%
80mV
76%
t 2%
4.75V-5.25V
EPA-15-12
12V, 1.25A
±3%
120mV
79%
± 2%
10.8V-13.2V
EPR-15-24
24V, 0.63A
±3%
120nnV
81%
±2%
21.6V-26.4V
EPA-15-48
48V, 0.32A
±3%
200mV
83%
± 2%
43.2V-52.8V
02
01 Eli la CI
EPR Series
Product features
Protections: Overload / Short circuit
Compact. High efficiency, High reliability
100% full load burn-in test
2 years warranty
Specifications
Input voltage
88-264VAC, 124-370VDC
47-63Hz
Input frequency
Inrush current
Hold up time
Overload protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
30A@230VAC full load cold start
--:==20ms@230VAC full load
110%-180% auto-recovery
-20-70`C (refer to output derating curve)
UL60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC. 1min
0/P-FG: 0.5kVAC, lmin
Weight
0.17kg/pcs
P/N
Output
Tol.
R&N
Effi.
Load Regulation
DC adjustment range
EPR-25-5
5V, 5A
±3%
80mV
76%
±2%
4.75V-5.25V
EPR-25-12
12V, 2.1A
±3%
120mV
79%
±2%
10.8V-13.2V
EPR-25-24
24V, 1.1A
±3%
120nnV
81%
±2%
21.6V-26.4V
EPR-25-48
48V, 0.57A
±3%
200mV
83%
±2%
43.2V-52.8V
03
1.1ITTIREMAO:
1RIMY
Universal AC input / full range
Power on indication
EPR Series
Size (12W*H)
99mm x 81mm x 36mm
Product features
IA 11 f: Ma! VITO D k 1 I Welril
Universal AC input / full range
Power on indication
Protections: Overload / Over voltage / Short circuit
Compact, High efficiency, High reliability
100% full load burn-in test
2 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
88-264VAC, 124-370VDC
47-63Hz
30A@230VAC full load cold start
_..-20ms@230VAC full load
110%-150% auto-recovery
110%-145%
-20-70t (refer to output derating curve)
UL60950-1, TUV EN60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, lmin
0/P-FG: 0.5kVAC, lmin
Weight
0.27kg/pcs
R&N
Effi.
Load Regulation
DC adjustment range
EPR-35-5
5V, 5A
± 3%
80mV
76%
± 2%
4.75V-5.25V
_ EPR-35-12
12V, 3A
±3%
120mV
81%
±2%
10.8V-13.2V
EPR-35-15
15V, 2.3A
±3%
120mV
81%
±2%
13.5V-16.5V
EPR-35-24
24V, 1.5A
±3%
120mV
83%
±2%
21.6V-26.4V
EPR-35-36
36V, 0.9A
± 3%
200mV
83%
± 2%
32.4V-39.6V
EPR-35-48
48V, 0.8A
± 3%
200mV
84%
± 2%
43.2V-52.8V
04
1:1313E11311
EPR Series
BT
015
CE CB rk,AL's
19
03.5
74
Product features
Universal AC input / full range
Power on indication
Protections: Overload / Over voltage / Short circuit
Compact, High efficiency, High reliability
100% full load burn-in test
2 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
88-264VAC, 124-370VDC
47-63Hz
30A@230VAC full load cold start
_?..-20ms(0230VAC full load
110%-150% auto-recovery
110%-145%
-20-70°C (refer to output derating curve)
UL60950-1, TUV EN60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, 1min
Weight
0.31kg/pcs
R&N
Effi.
Load Regulation
EPR-50-5
5V, 8A± 3%80mV
77%
± 2%
4.75V-5.25V
EPR-50-12
12V, 4.2A±3%120mV
81%
±2%
10.8V-13.2V
EPR-50-15
15V, 3.3A±3%120mV
81%
±2%
13.5V-16.5V
EPR-50-24
84%
±2%
21.6V-26.4V
EPR-50-36
24V, 2.2A±3%120mV
36V, 1.3A±3%120mV
84%
±2%
32.4V-39.6V
EPR-50-48
48V, 1.1A±3%200mV
86%
±2%
43.2V-52.8V
Output
05
DC adjustment range
ES PI!
EPR Series
eie
173.5
Q
O
,
1
, :
ck,
V)
-4./-
111=1:11
=col
ii.
75.5
Product features
Universal AC input / full range
Power on indication
Protections: Overload / Over voltage / Short circuit
Compact, High efficiency, High reliability
100% full load burn-in test
2 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
88-264VAC, 124-370VDC
47-63Hz
30A4g11230VAC full load cold start
?-.20ms@230VAC full load
110%-150% auto-recovery
110%-145%
-20-70t (refer to output derating curve)
UL60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, lmin
0/P-FG: 0.5kVAC, 1nnin
0.41kg/pcs
Tol.
R&N
Effi.Load RegulationDC adjustment range
_
EPR-75-5
5V, 12A
±3%
80mV
76%
±2%
4.75V-5.25V
_ EPR-75-12
12V, 6.2A
±3%
120mV
81%
±2%
10.8V-13.2V
EPR-75-15
15V, 5A
±3%
120mV
81%
±2%
13.5V-16.5V
EPR-75-24
24V, 3.2A
±3%
120mV
84%
±2%
21.6V-26.4V
EPR-75-36
36V, 2.1A
±3%
120mV
84%
±2%
32.4V-39.6V
EPR-75-48
48V, 1.6A
± 3%
200mV
86%
± 2%
43.2V-52.8V
06
EPR Series
CD ISE11311
NMI
gird.
035
/
1=7
.05Q
m=u
_
1_2) 5 CE CB (74
Al ®
4■■1■1
* —
ema
117
1
Product features
Universal AC input / full range
Power on indication
Protections: Overload / Over voltage / Short circuit
Compact, High efficiency, High reliability
100% full load burn-in test
2 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
Output
EPR-100-5
EPR-100-12
EPR-100-15
EPR-100-24
EPR-100-36
EPR-100-48
5V, 14A
12V, 8.5A
15V, 6.6A
24V, 4.5A
36V, 2.7A
48V, 2.3A
±3%
±3%
±3%
±3%
±3%
±3%
80mV
120mV
120mV
120mV
200mV
200mV
Effi.
Load Regulation
DC adjustment range
76%
±2%
± 2%
±2%
±2%
±2%
±2%
4.75V-5.25V
10.8V-13.2V
13.5V-16.5V
21.6V-26.4V
81%
81%
84%
84%
84%
07
88-264VAC, 124-370VDC
47-63Hz
>35A6t0230VAC full load cold start
_?-20ms@230VAC full load
110%-150% auto-recovery
110%-145%
-20-70t (refer to output derating curve)
UL60950-1, TUV EN60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, lmin
0/P-FG: 0.5kVAC, 1min
0.51kg/pcs
32.4V-39.6V
43.2V-52.8V
213219113 op WI
EPR Series
‘j4
:5 .- •
•
;
- • •
to. •
: •--
.+. • -
0.3
---5 -- ---41r 1
i
'1'
i
il
4-M3
I
lt-Itt
t
+
Ofr
r
62
1
03.5
199
120
1
in
, ..ea-13-6113
.
ami
41
CE CB1 csMus
Product features
AC input selectable by switch
Power on indication
Protections: Overload / Over voltage / Short circuit
Compact, High efficiency, High reliability
100% full load burn-in test
2 years warranty
Specifications
Weight
88-132VAC, 176-264VAC,
249-370VDC
47-63Hz
35A@230VAC full load cold start
-20ms@230VAC full load
110%-150% auto-recovery
110%-145%
-20-70t (refer to output derating curve)
UL60950-1, TUV EN60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, 1min
I/P-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, 1min
0.61kg/pcs
R & NEffi.
Load RegulationDC adjustment range
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
,
EPR-150-5
5V, 22A
±3%
80mV
77%± 2%
4.75V-5.25V
EPR-150-12
12V, 12.5A
±3%
120mV
83%
±2%
10.8V-13.2V
EPR-150-15
15V, 10A
±3%
120mV
83%
±2%
13.5V-16.5V —
EPR-150-24
24V, 6.5A
±3%
120mV
86%
±2%
21.6V-26.4V
EPR-150-36
36V, 4.1A
±3%
200mV
86%
±2%
32.4V-39.6V
EPR-150-48
48V, 3.3A
±3%
200mV
87%
±2%
43.2V-52.8V
08
ESP Series
Ea 02 CD El 0 RI
E.,
INIII
= _..
-_
4
.
,.
5 SEEITMI
,
,
,
,
'0•1
I
11
035
=
'$-(0
4:7
53.6
107
Product features
Universal AC input! full range
Constant voltage or constant current (CV/CC)
Protections: Short circuit / Overload / Over voltage / Over temperature
Suitable for led display, industry control
LED indicator for power on
1 year warranty
Specifications
Input voltage
Input frequency
Inrush current
90-264VAC
47-63Hz
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
[email protected] full load cold start
_- 20ms@230VAC full load
110%-150% auto-recovery
110%-145%
-20-70t (refer to output derating curve)
EN60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, 1min
0.35kg/pcs
1 Ul. I 1 Ot 14 L-111.1_,Jal.2 1 1G9UICUIVI 11_,..., 0.41j1.4041 1 !GI It I721 1.9G
ESP-60-12
_
ESP-60-15
ESP-60-18
ESP-60-24
_ ESP-60-36
ESP-60-48
12V, 5A
15V, 4A
18V, 3.3A
24V, 2.5A
36V, 1.6A
48V, 1.25A
,---
±3%
±3%
±3%
±3%
±3%
±3%
■
L
120mV
120mV
150mV
240mV
240mV
240mV
_
84%
87%
88%
88%
89%
89%
09
±2% 10.8V-13.2V
±2% 13.5V-16.5V
±2%
_
16.2V-19.8V
±2%
21.6V-26.4V
±2%
32.4V-39.6V
±2%
43.2V-52.8V
001li!!11MIII:E1
ESP Series
02.5
+
035
84i-3-M3
to=
0.12
LILL
=
0_
6130
1
Product features
AC input selectable by switch
Constant voltage
Protections: Short circuit / Overload / Over voltage / Over temperature
Suitable to industry control
LED indicator for power on
1 year warranty
Specifications
Input voltage
Hold up time
Overload protection
Over voltage protection
Operating temperature
110%-145%
-20-70t (refer to output derating curve)
Safety standard
EMC standard
Withstand voltage
EN60950-1
EN55022 Class B, EN55024
Input frequency
Inrush current
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, lmin
0/P-FG: 0.5kVAC, lmin
0.60kg/pcs
Weight
Tol.
11.1
88-132VAC, 176-264VAC
47-63Hz
55A@230VAC full load cold start
.-20ms@230VAC full load
110%-150% auto-recovery
R & NEffi.Load RegulationDC adjustment range
88% 2'. 21.6V-26.4V
ESP-100-2424V, 4.5A 1 ± 3% 1200mV88%
10
_
ESP Series
EICSIRI%F13
mgium
<1
H
L Hllo..D
12oneN I
DI
ons
Product features
AC input selectable by switch
Protections: Overload / Over voltage / Short circuit
Fan cooling
100% full load burn-in test
1 year warranty
Specifications
Input voltage
Input frequency
88-132VAC, 176-264VAC
47-63Hz
<50A full load cold start
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
-:-:=20ms@230VAC full load
120%-150%
constant current limiting, auto-recovery
115%-145%
-20-70°C (refer to output load derating curve)
EN60950-1
EN61000-6-2
EN61000-4-2,3,4.5,6,81 11
EN55022 Class B
Withstand voltage
I/P-0/P: 1.5kVAC, lmin
UP-FG: 1.5kVAC. 1min
Weight
0/P-FG: 0.5kVAC, 1min
0.89kg/pcs
R & NEffi.
Load RegulationDC adjustment range
Output
Tol.
ESP-200-24
24V, 8.3A
±3%
100mV
83%
±2%
21.6V-26.4V
ESP-200-36
36V, 5.6A
±3%
240nnV
84%
±2%
32.4V-39.6V1
ESP-200-48
48V, 4.2A
± 3%
240mV
85%
± 2%
43.2V-52.8V
11
ail a ha 191s
ESP Series
it
bmax,
UI
0,
[
LJJI
I]i,
---I.1.1 II 1.1.1 1 A1111.1
ABE
215
--
Product features
AC input selectable by switch
Protections: Overload / Over voltage / Short circuit
Fan cooling
100% full load burn-in test
1 year warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
88-132VAC, 176-264VAC
47-63Hz
<50A full load cold start
=_--- 20ms@230VAC full load
120%-150%
constant current limiting, auto-recovery
120%-150%
-20-70t (refer to output load derating curve)
EN60950-1
EN61000-6-2
EN61000-4-2,3,4,5,6,8,11
EN55022 Class B
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, lmin
0/P-FG: 0.5kVAC, 1min
0.90kg/pcs
Weight
R&N
Effi.Load Regulation
DC adjustment range
ESP-250-24
24V, 10.5A
±3%
100mV
83%
±2%
21.6V-26.4V
ESP-250-36
36V, 6.9A
±3%
300mV
83%
±2%
32.4V-39.6V
ESP-250-48
48V, 5.2A
± 3%
300mV
85%
± 2%
43.2V-52.8V
12
ESP Series
la eg
"pp
1.11,1
s
M[1=
ri.n
n4_0
__ 41-11.11-114141-1111-araill1414-1M-R-ral--- -'11
150
23
I215
a
Product features
AC input selectable by switch
Protections: Overload / Over voltage / Short circuit
Fan cooling
100% full load burn-in test
1 year warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
47-63Hz
<50A full load cold start
_-20ms@230VAC full load
120%-150%
constant current limiting, auto-recovery
115%-145%
-20-70t (refer to output load derating curve)
EN60950-1
EN61000-6-2
EN61000-4-2,3,4.5,6,8,11
EN55022 Class B
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, lmin
0/P-FG: 0.5kVAC, 1min
0.92kg/pcs
Weight
P/N
88-132VAC, 176-264VAC
OutputTol.R & N
Effi.
Load RegulationDC adjustment range
I
_
ESP-350-24
24V, 14.6A
±3%
100mV
83%
±2%
21.6V-26.4V
ESP-350-36
36V, 9.7A
± 3%
240nnV
84%
±2%
32.4V -39.6V
ESP-350-48
48V, 7.3A
± 3%
240mV
85%
± 2%
43.2V-52.8V
13
Security Series
c'3
_
o
o
2-103 A
1 . CIE
COD
rar
g
\
_r12,
105
Product features
Universal AC input / full range
Power on indication
Air cooling
Protection for deeply discharged battery
Protections: Overload / Short circuit
Metal case, Compact
100% full load burn-in test
1 year warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
90-264VAC
47-63Hz
40A@220VAC full load cold start
__-20ms@230VAC
105%-180% auto-recovery
-20-40t
GB4943-2001, EN60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, 1min
0.30kg/pcs
P/N
Output
Tol.
R&N
Effi.
Load Regulation
ESP-20-13.8A
13.8V, 1.5A
±3%
140mV
80%
± 2%
14
a
Security Series
Product features
Universal AC input / full range
Power on indication
Air cooling
Protection for deeply discharged battery
Protections: Overload / Short circuit
Metal case, Compact
100% full load burn-in test
1 year warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
90-264VAC
47-63Hz
40A@220VAC full load cold start
_-- 20ms@230VAC
105%-180% of the rated output power
-20-40t
GB4943-2001, EN60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC. 1min
0/P-FG: 0.5kVAC, 1min
0.37kg/pcs
P/N
Output
Tol.
R&N
Effi.
Load Regulation
ESP-42-13.8A
13.8V, 3A
±3%
140mV
80%
±2%
ESP-42-27.6A
27.6V, 1.5A
±3%
240mV
80%
±2%
i
Security Series
13 RI =0 Eli
015
0,1 1
1, 03.5
3-M3
22
fly
--IF
''''
..-4..,
-I
Product features
Universal AC input / full range
Power on indication
Air cooling
Protection for deeply discharged battery
Protections: Overload / Short circuit
Metal case, Compact
100% full load burn-in test
1 year warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
P/N
ESP-70-13.8A
90-264VAC
47-63Hz
40A@220VAC full load cold start
.--:-1,20ms@230VAC
105%-180% of the rated output power
-20-40t
GB4943-2001, EN60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, 1min
0.45kg/pcs
Output
:rol.R & NEffi.Load Regulation
13.8V, 5A
±3% I140mVI80%
16
± 2%
CD ha 11=1
Security Series
03_5
03.5
Ab. 11
+,
i
4-
xj
i'll
Product features
230VAC input only
Power on indication
Metal case
Protections: Overload / Short circuit
Battery reverse charge protection
100% full load burn-in test
1 year warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
195-253VAC
50-60Hz
40A@220VAC full load cold start
--_-_-1, 20ms@230VAC full load
300% of the rated output power
-20-40t
EN60950, GB4943-2001
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC. 1min
0/P-FG: 0.5kVAC, 1min
0.37kg/pcs
P/N
Output
Tol.
R&N
Effi.
Load Regulation
ESP-20-13.8
13.8V, 1.5A
±3%
140mV
80%
±2%
dr
la
17
1
Security Series
CDP
03.5
TA
Product features
230VAC input only
Power on indication
Metal case
Protections: Overload / Short circuit
Battery reverse charge protection
100% full load burn-in test
1 year warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
P/N
Output
195-253VAC
50-60Hz
40A@220VAC full load cold start
__-20ms@230VAC full load
150% of the rated output power
-20-40t
EN60950, GB4943-2001
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC. 1min
0/P-FO: 0.5kVAC, 1min
0.37kg/pcs
74. Load Regulation
Tol. R & N Effi. -
ESP-42-13.8
13.8V, 3A
±3%120mV 70%
±2%
ESP-42-27.6
27.6V, 1.5A
±3% I240mV 70%
± 2%
18
Security Series
NMI
03$
t
/T073
093.5
.V11-
22 ,
117
Product features
230VAC input only
Power on indication
Metal case
Protections: Overload / Short circuit
Battery reverse charge protection
100% full load burn-in test
1 year warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
195-253VAC
50-60Hz
40A@220VAC full load cold start
_- 20ms@230VAC full load
150% of the rated output power
-20-40t
EN60950, 0B4943-2001
EN55022 Class B, EN55024
I/P-0/P: 3kVAC, lmin
I/P-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, lmin
0.45kg/pcs
Tol. R & N
Effi.Load Regulation
13.8V, 5A
±3%
120mV
76%
± 2%
27.6V, 2.5A
±3%
240mV
80%
± 2%
P/N
Output
ESP-70-13.8
ESP-70-27,6
Security Series
C:15P
PPlirrP..
03 5
0:?.5
, -••
41_4.
195
15g
•
d
Product features
230VAC input only
Power on indication
Metal case
Protections: Overload / Short circuit
Battery reverse charge protection
100% full load burn-in test
1 year warranty
Specifications
Input voltage
195-253VAC
Input frequency
50-60Hz
Inrush current
40A@220VAC full load cold start
Hold up time
;_--- 20ms@230VAC full load
Overload protection
150% of the rated output power
Operating temperature
-20-40t
Safety standard
EN60950, GB4943-2001
EMC standard
EN55022 Class B, EN55024
Withstand voltage
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, 1min
Weight
1
.P/N
ESP-140-13.8
ESP-140-27.6
27.6V, 5A
R&N
Tol.
Output
1
13.8V, 10A
0.70kg/pcs
Load Regulation
Effi.
1
it
±3%
120mV
80%
±2%
±3%
240mV
83%
± 2%
20
ESF Series
BIRS '1) OM
,
ED
0
31
0
1
77
Product features
Universal AC input I full range
PF>0.96@115VAC, >0.93 ©230VAC
Built-in remote ON/OFF control
Standby power consumption 0.5W
Power on indication
Air cooling
Protection: Overload / Over voltage / Short circuit / Over temperature
100% full load burn-in test
2 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage Protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
90-264VAC
47-63Hz
40A@230VAC
20A@110VAC full load cold start
._- 20ms@230VAC full load
105%-150% auto-recovery
105%-140%
-20-70°C (refer to output load derating curve)
UL60950-1, EN60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, 1min
0/13-FG: 0.5kVAC, 1min
0.42kg/pcs
._
Load Regulation1
Output
Tol.
R&N
Effi.
ES F-75-5
5V, 15A
±2.5%
100mV
80%
±2%
ESF-75-12
12V, 6.3A
±1.5%
100mV
87%
± 1%
ES F-75-24
24V, 3.2A
± 1.5%
150mV
88%
± 1%
,ESF-75-48
48V, 1.5A
± 1.5%
240mV
90%
± 1%
P/N
21
sr
ESF Series
100W *IMA LT,
PFC,Ijj fit EP. a
100W Single Output (with PFC)
Size (L*W*H)
129mm x 98mm x 38mm
Product features
IAMR111
41:
0WatellE0
Universal AC input / full range
PF>0.96@115VAC, >0.93 4. 230VAC
Built-in remote ON/OFF control
Standby power consumption .50.5W
Power on indication
Air cooling
Protection: Overload / Over voltage / Short circuit / Over temperature
100% full load burn-in test
2 years warranty
Specifications
Input voltage
Input frequency
Inrush current
90-264VAC
47-63Hz
40A@230VAC
20A@110VAC full load cold start
Hold up time
20ms(§230VAC full load
Overload protection
105%-150% auto-recovery
Over voltage protection 105%-140%
Operating temperature
-20-70°C (refer to output load derating curve)
Safety standard
UL60950-1, EN60950-1
EMC standard
EN55022 Class B, EN55024
Withstand voltage
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, 1min
Weight
0.42kg/pcs
P
Output
Tol,
R&N
Effi.
Load Regulation
ESF-100-5
5V, 18A
± 2.5%
100mV
80%
± 2%
ESF-100-12
12V, 8.4A
± 1.5%
100mV
87%
± 1%
ESF-100-24
24V, 4.2A
±1.5%
150mV
88.5%
± 1%
ESF-100-48
48V, 2.1A
± 1.5%
240mV
90%
± 1%
__,
22
B
ESF Series
GS
(01))
150W *NM LT, PA' P FC fit EP. a
150W Single Output (with PFC)
Size (L*W*H)
159mm x 97mm x 38mm
,
'
-
Product features
Mr:nit-14:kIATCMC
Universal AC input! full range
PFA.96@115VAC, ›0.93@230VAC
Built-in remote ON/OFF control
Standby power consumption-5.0.5W
Power on indication
Built-in 5V/0.3A standby output
Air cooling
Protection: Overload / Over voltage / Short circuit
100% full load burn-in test
2 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
90-264VAC
47-63Hz
70A@230VAC
35A@110VAC full load cold start
..20ms@230VAC full load
105%-150% auto-recovery
105%-140%
-20-70t (refer to output load derating curve)
UL60950-1, EN60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, 1min
I/P-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, 1min
0.58kg/pcs
P/N
Output
Tol.
R&N
Eth.
Load Regulation
ESF-150-12
12V, 12.5A
± 1.5%
100mV
87%
± 1%
ESF-150-24
24V, 6.4A
±1.5%
150mV
88%
± 1%
ESF-150-48
48V, 3.2A
±1.5%
300mV
90%
± 1%
23
ESF Series
'kW
150
U., 51ra
117
Product features
Universal AC input / full range
PFA.96 e 115VAC, ›0.93@230VAC
Built-in remote ON/OFF control
Standby power consumption-50.5W
Power on indication
Built-in 5V/0.3A standby output
Air cooling
Protection: Overload / Over voltage / Short circuit
100% full load burn-in test
2 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
90-264VAC
47-63Hz
70ACO230VAC
35A(0110VAC full load cold start
..20ms@230VAC full load
105%-150% auto-recovery
105%-140%
-20-70t (refer to output load derating curve)
UL60950-1, EN60950-1
EN55022 Class B, EN55024
I/P-0/P: 1.5kVAC, lmin
I/P-FG: 1.5kVAC, lmin
0/P-FG: 0.5kVAC, 1min
0.58kg/pcs
P/N
Output
Tol.
R&N
Eth.
Load Regulation
ESF-200-12
12V, 16.7A
± 1.5%
100mV
87%
± 1%
ESF-200-24
24V, 8.4A
± 1.5%
150mV
88%
± 1%
ESF-200-48
48V, 4.2A
±1.5%
300mV
90%
± 1%
—
24
ESFG Series
Product features
Universal AC input / full range
Active PFC meets EN61000-3-2
High efficiency at 90% typical
Protections: Short circuit / Over load / Over voltage / Over temperature
Remote voltage sense
U-bracket low profile: 38mm
2 years warranty
Specifications
Input voltage
Input frequency
90-264VAC
Inrush current
Hold up time
Leakage current
Total rated output power
Operating temperature
.
I
P/N
Safety standard
EMC standard
Withstand voltage
0/P-FG: 0.5kVAC, lmin
1.07kg/pcs
Weight
DC Output
47-63Hz
44A@230VAC full load cold start
-:-=16ms@230VAC full load
2mA max
300W (Air cooling)
350W (23.5CFM FAN)
-20-65t
UL60950-1, EN60950-1
CISPR / FCC Class B
I/P-0/P: 3kVAC, 1min
I/P-FG: 1.5kVAC, 1min
Output Current
R&N
Tot.
Load Regulation
ESFG-350-24
24V
12.5A
14.6A
150mV
±2%
±0.1%
ESFG-350-36
36V
8.3A
9.7A
150mV
±2%
± 0.1%
ESFG-350-48
48V
6.25A
7.3A
150mV
±2%
±0.1%
25
EDA Series
MI la Pi
E
ha
Product features
Universal AC input/full range
Power on indication
Air cooling
Protection: Overload / Over voltage / Over temperature I Short circuit
100% full load burn-in test
3 years warranty
Specifications
Input voltage
Input frequency
Inrush current
88-264VAC, 124-370VDC
47-63Hz
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Output
Tol.
EDA-45-5
EDA-45-12
EDA-45-24
EDA-45-48
5V, 5A
12V, 3.5A
24V, 2.0A
±2%
±2%
±2%
±2%
48V, 1.0A
105%-150%
auto-recovery, constant current limiting
115%-135%
-25-70t (refer to output load derating curve)
EN60950-1, UL508
EN55022 Class B
EN61000-6-2
I/P-0/P: 3kVAC, lmin
I/P-FG: 1.5kVAC, lmin
0/P-FG: 0.5kVAC, 1min
0.31kg/pcs
Weight
P/N
35A@230VAC full load cold start
--_-=, 20ms@230VAC full load
R&N
Effi.Load Regulation
50mV
100mV
120mV
,200mV
81%
85%
87%
89%
26
±2%
±2%
±2%
± 2%
DC Adjustment Range
5V-5.5V
12V-14V
24V -28V
48V-53V
EDA Series
COMPIIME1301
Product features
Universal AC input / full range
Power on indication
Air cooling
Protection: Overload / Over voltage / Over temperature / Short circuit
100% full load burn-in test
3 years warranty
Specifications
Input voltage
Input frequency
Inrush current
88-264VAC, 124-370VDC
47-63Hz
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
0/P-FG: 0.5kVAC, 1min
0.36kg/pcs
Weight
P/N
35A@230VAC full load cold start
_-.20ms@230VAC full load
105%-150%
auto-recovery, constant current limiting
115%-135%
-25-70'C (refer to output load derating curve)
EN60950-1, UL508
EN55022 Class B
EN61000-6-2
I/P-0/P: 3kVAC, 1min
I/P-FG: 1.5kVAC, lmin
Output
Tol.
R & NEffi.Load RegulationDC Adjustment Range 1
5V, 5A
± 2%
50mV
82%
12V, 3.5A
±2%
100mV
86%
±2%
12V-14V
EDA-75-24
24V, 2.0A
±2%
120mV
88%
±2%
24V-28V
EDA-75-48
48V, 1.0A
± 2%
200mV
90%
± 2%
48V-53V
EDA-75-5
EDA-75-12
_
27
± 2%
5V-5.5V
EDA Series
Product features
Universal AC input / full range
PF >0.99@115VAC, >0.96@230VAC
High efficiency, high reliability
Power on indication
Air cooling
Built-in DC OK relay contact.
150% peak load capability
Optional inrush current immunity. Less than 10A
Optional current Sharing.
Protections: Overload / Over voltage / Over temperature / Short circuit
100% full load burn-in test
3 years warranty
Specifications
Input voltage
Input frequency
Inrush current
88-264VAC, 124-370VDC
47-63Hz
70A@230VAC
35A@115VAC full load cold start
-1,-1,20ms@230VAC full load
105%-150% of full load for 3s and shut
down output voltage with auto-recovery
120%-140%
-25-70t (refer to output derating curve)
EN60950-1, UL508
EN55022 Class B
EN61000-6-2
I/P-0/P: 3kVAC, lmin
I/P-FG: 1.5kVAC. 1min
0/P-FG: 0.5kVAC, 1min
0.54kg/pcs
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
P/N
Output
'Tol.
R&N
Effi.
Load RegulationDC Adjustment Range
1
EDA-120-12
12V, 10A
± 1%
EDA-120-24
24V, 5A
± 1%
48V, 2.5A
± 1%
.EDA-120-48
90%
± 1%
12V-14V
80mV
91%
± 1%
24V-28V
130mV
92%
t1%
48V-53V
80nnV
EDA Series
Product features
Universal AC input / full range
PF ›0.99@ 115VAC, ›0.96@ 230VAC
High efficiency, high reliability
Power on indication
Air cooling
Built-in DC OK relay contact.
Optional current Sharing.
Protections: Overload / Over voltage / Over temperature / Short circuit
100% full load burn-in test
3 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
P/N
Output
EDA-240-24
24V, 10A
EDA-240-48
48V, 5A _
88-264VAC, 124-370VDC
47-63Hz
65A@230VAC
35A@115VAC full load cold start
_- 20ms@230VAC full load
105%-150% of full load, shut down output
voltage with auto-recovery
120%-140%
-25-70t (refer to output derating curve)
EN60950-1, UL508
EN55022 Class B
EN61000-6-2
I/P-0/P: 3kVAC, lmin
I/P-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, 1min
0.81kg/pcs
R&N
Effi.
Load Regulation
DC Adjustment Range
_ ± 1%
100mV
92%
± 1%
24V-28V
± 1%
150mV
92%
± 1%
48V-53V
Tol.
Bla
EDA Series
1 10 I" 8 M.
61
1
lEm■
-
Product features
Universal AC input / full range
PF>0.99@ 115VAC, >0.96@ 230VAC
High efficiency, High reliability, Compact case
Power on indication
Air cooling
Built-in DC OK relay contact
150% peak load capability
Optional current Sharing (9+1)
Protections: Overload / Over voltage / Over temperature / Short circuit
100% full load burn-in test
3 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
P/N
Output
'Tol.
R&N
Effi.
100mV
1.1
88-264VAC, 124-370VDC
47-63Hz
35A@230VAC
20A@115VAC full load cold start
3-2,20ms©230VAC full load
105%-150% of full load for 3s and shut
down output voltage with auto-recovery
120%-140%
-25-70°C (refer to output derating curve)
EN60950-1, UL508
EN55022 Class B
EN61000-6-2
I/P-0/P: 3kVAC, lmin
I/P-FG: 1.5kVAC. 1min
0/P-FG: 0.5kVAC, lmin
1.32kg/pcs
Load Regulation
DC Adjustment Range
94%
± 2%
24V-28V
36V-40V
48V-55V
,
E DA-480-24
24V, 20A
EDA-480-36
36V, 13.5A
± 1%
150mV
94%
±2%
EDA-480-48
48V, 10A
± 1%
150mV
94%
t 2%
±1%
EDR Series
Product features
Universal AC input full range
DC OK indication
Air cooling
Protections: Overload / Over voltage / Short circuit
Plastic case and low cost
Double Insulation, high security
100% full load burn-in test
3 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
lP/N
Il
85-264VAC
47-63Hz
15A@115VAC, 30A@230VAC
30ms@230VAC full load
120%-200% auto-recovery
120%-140%
-20-70°C
UL60950-1, EN60950-1
EN55022 Class B, En55024
I/P-0/P: 3kVAC, 1min
UP-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, 1min
0.20kg/pcs
Output
Tot.
R&N
Effi.
Load Regulation
5V, 1.5A
±5%
50mV
75%
±2%
EDR-10-12
12V, 0.83A
±5%
50mV
80%
±2%
EDR-10-24
24V, 0.42A
±5%
50mV
80%
±2%
EDR-10-48
48V, 0.21A
±5%
50mV
84%
±2%
EDR-10-5
EDR Series
ip
-
pon— •
Product features
Universal AC input / full range
Power on indication
Air cooling
Protections: Overload / Over voltage / Over temperature / Short circuit
Plastic case and low cost
Double Insulation, high security
100% full load burn-in test
3 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
P/N
EDR-30-12
EDR-30-24
Output
12V, 2.5A
24V, 1.25A
85-264VAC
47-63Hz
15A@100VAC
30A@200VAC
------ 30ms @230VAC full load
120%-200% auto-recovery
120%-140%
-10-70t
EN60950, UL508
EN55022 Class B
EN61000-6-2
I/P-0/P: 3kVAC, lmin
IIP-FG: 1.5kVAC, 1min
01P-FG: 0.5kVAC, 1min
0.22kg/pcs
Tol. R & N•Effi.Load Regulation
±5%
± 5%
32
50mV
83%
±2%
50mV
83%
± 2%
M E CO
EDR Series
Hi' 1
l'7,71
0
0
0
;
0
0
-
El
71
1
0
0
0•
57
Product features
Universal AC input/full range
Power on indication
Air cooling
Protections: Overload / Over voltage / Over temperature / Short circuit
Plastic case and low cost
Double Insulation, high security
100% full load burn-in test
3 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
Tol.R & N
85-264VAC
47-63Hz
15A @ 100VAC
30A@200VAC
::_1, 30ms@230VAC full load
120%-200% auto-recovery
120%-140%
-10-70t
EN60950, UL508
EN55022 Class B
EN61000-6-2
I/P-0/P: 3kVAC, lmin
I/P-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, 1min
0.26kg/pcs
P/N
Output
EDR-60-12
12V, 5A
± 5%
50mV
86%
±2%
EDR-60-24
24V, 2.5A
± 5%
50mV
86%
± 2%
33
1 Effi.Load Regulation
EDR Series
gro
0
0
=MEI
0
0
57
Product features
Universal AC input / full range
Power on indication
Air cooling
Protections: Overload / Over voltage / Over temperature / Short circuit
Plastic case and low cost
Double Insulation, high security
100% full load burn-in test
3 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
Output
85-264VAC
47-63Hz
15A @ 100VAC
30A@200VAC
-7-_,1 30ms @230VAC full load
120%-200% auto-recovery
120%-140%
-10-70°C
EN60950, UL508
EN55022 Class B
EN61000-6-2
I/P-0/P: 3kVAC, lmin
I/P-FG: 1.5kVAC, 1min
0/P-FG: 0.5kVAC, lmin
0.38kg/pcs
Tol. R & N
Effi.•Load Regulation
EDR-100-12
12V, 8.33A
±5%
50mV
86%
±2%
EDR-100-24
24V, 4.17A
±5%
50mV
86%
±2%
34
OPEN-FRAME POWER SUPPLY
OP Series
Size (L*W*H).
101 6mm x 50.8mm x 33mm
Product features
100% full load burn-in test
2 years warranty
Specifications
Input voltage
Output voltage
90-264VAC
24VDC
Input frequency
Operating temperature
47-63Hz
-20-70t
Storage temperature
R&N
Voltage regulation
-45-90t
Efficiency
Safety standards
EMC standards
Weight
± 3%
>82%
UL60950-1
GB4943-2001
EN55022 Class B, EN55024
0.11kg/pcs
Open frame power is commonly made to meet custom needs, such as dimension to fit the internal space of clients' machine.
Considering the delivery and price, we suggest you to use standard ones in our manual. Meanwhile, we also accept customization.
IA r il EIT=1: k MAO W iFM= 0 Si 0 F[€
Universal AC input! full range
Protections: Overload / Over voltage! Short circuit
OP Series
Size (L*W*FI).
101 6mm x 50.8mm x 33mm
Product features
Universal AC input / full range
Ir0171:
IIkCC
Protections: Overload / Over voltage / Short circuit
100% full load burn-in test
2 years warranty
PAMr:
Specifications
Input voltage
90-264VAC
Output voltage
24VDC
Input frequency
47-63Hz
Operating temperature
-25-70t
Storage temperature
-45-90t
R&N
Voltage regulation
± 30/0
Efficiency
>82%
Safety standards
UL60950-1
EMC standards
GB4943-2001
EN55022 Class B, EN55024
Weight
0.30kg/pcs
ECU devotes to service our customers with power supplies and solutions of high efficiency and high reliability. If our catalog
products cannot meet your requirements, please contact our sales for more information.
OP Series
Product features
Universal AC input / full range
Protections: Over temperature / Short circuit / Short voltage
100% full load burn-in test
2 years warranty
Specifications
Input voltage
90-264VAC
Input frequency
47-63Hz
Inrush current
50A@220VAC
30A @ 110VAC
Output voltage
12VDC
Hold-up time
:;=,20ms@230VAC
_
full load
Overload protection
105%-180%
Operating temperature
0-40t
Storage temperature
-40-70t
R&N
150mV
Efficiency
Safety standards
UL1950-1
EN60950, TUV
EMC standards
CSA 22.2 No.234
Withstand voltage
11P-0/P: 3kVAC, lmin
Weight
0.05kg/pcs
ECU's power supplies have high reliability because all of them must pass through 100% burn-in test. which lasts for four hours.
IArElf-6WklivaDIMITZITAEl■tf:IC
Over current / Over voltage protection adjustable
B
OP Series
Product features
Universal AC input / Full range
Protections: Over voltage / Short circuit
100% full load burn-in test
2 years warranty
Specifications
Input voltage
90-264VAC
Nominal 100-240VAC
Input frequency
47-63Hz
35A@230VAC full load cold start
Inrush current
Over voltage protection
Operating temperature
Safety standard
EMC standard
Withstand voltage
Weight
18A@115VAC full load cold start
110-160%
0-40t
UL60950
EN55022 Class B
I/P-0/P: 3kVAC, lmin
I/P-FG: 1.5kVAC, 1min
0.24kg/pcs
Tol.1
R & N Effi.Load Regulation
5V, 10A
±4%
80mV
81%
± 2%
OP-50-12
12V, 4.2A
±2%
100mV
82%
± 1%
OP-50-24
24V, 2.1A
±2%
200mV
85%
± 1%
OP-50-5
38
OP Series
vio
Product features
Universal AC input / full range
Power on indication
Cooling by free air convection
Protections: Short circuit / Over voltage / Over load
100% full load burn-in test
2 years warranty
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Over voltage protection
Operating temperature
Safety standards
EMC standards
Withstand voltage
P/N
Output
OP-60-12
OP-60-24
90-264VAC
47-63Hz
40A@230VAC
25A@115VAC full load cold start
-320ms@230VAC full load
110-160%
0-50t
IEC60950-1
EN55022 Class B, EN55024
I/P-0/P: 3kVAC, lmin
I/P-FG: 1.5kVAC. lmin
Connection
0/P-FG: 0.5kVAC, 1min
3P/6P 3.96mm
Weight
HX39603-3A HX39603-6A
0.30kg/pcs
Tol.'
R&N
Effi.
Load Regulation
12V, 0-5A
±2%
100mV
80%
± 1%
24V, 0-2.5A
±2%
240mV
83%
± 1%
_
39
INDUSTRY-SPECIFIC POWER SUPPLY
COMMUNICATION POWER SUPPLY SERIES
ECP Series
ECP-350
2 29
Q
Size (L*W*H).
220mm x 87mm x 48.5mm
B
& 0000000000000000000001
0 0 0 0 0 q 000000 0
, .41'• 000000000000000000000 I
:
,':,' 00000
00
00
_e_zpoe
oet..
00000000 =
000100,-,00000000 111
0
Product features
I r EVALI! 4.11111 I gi I
AC/OK signal DC/OK signal TTL signal remote control
Output Protections: Overload / Over voltage / Over temperature
/ Short circuit
Input Protections: Over voltage Under voltage
MTBF: -3--'100kHrs at 25t
Air cooling
E! 0 Vale
Specifications
Input voltage
Frequency range
Max input ac current
Inrush current
Operate Efficiency
Storage temperature
Operating temperature
Operating Humidity
Harmonic current
IEC61000-3-2 Class D
Less than 0.75mA. 230VAC
Leakage current
Input under voltage
Input over voltage
r
150-300VAC
50Hz / 60Hz ± 5%
6A max at full load
30A max. 230VAC
85%, 230 VAC
-45-85t
-40-70t
10%-90% RH
Meet GB17625.1-1998
140-160VAC
300-325VAC
Output Characteristics
P/N
Output voltage
Rated current
Regulation
OVP
UVP
OCP
+28V
10A
± 2%
30.5-34V
13-20V
11.5-15.5A
+9V
8A
±2%
10-13V
6-8.5V
8.3-13.5A
ECP-350
MI Gil CI la
ECP Series
Product features
AC/OK signal DC/OK signal TTL signal remote control
Output Protections: Overload / Over voltage / Over temperature
/ Short circuit
Input Protections: Over voltage / Under voltage
MTBF: _.-.100kHrs at 25t
Forced air cooling by built-in DC fan with fan speed
Input voltage
Frequency range
Max input ac current
Inrush current
Operate Efficiency
Storage temperature
Operating temperature
Operating Humidity
Harmonic current
Leakage current
Input under voltage
Input over voltage
d d 83M
Specifications
150-300VAC
50Hz / 60Hz ±5%
5A max at full load
30A max, 230VAC
_?-88%, 230 VAC
-45-85t
-40-70t
10%-90% RH
Meet GB17625.1-1998
IEC61000-3-2 Class D
Less than 0.75mA, 230VAC
135-145VAC
300-325VAC
Output Characteristics
P/N
ECP-500
Output voltage
Rated current
Regulation
OVP
UVP
OCP
+27V
15A
±2%
30.5-34V
13-20V
23-25A
+9V
8A
± 2%
10-13V
6-8.5V
11-13.5A
+M9V
3A
± 2%
10-13V
6-8.5V
5.5-7A
Battery
0.4A
12.4-12.8
41
10-12V
ECP Series
ECP-700W
Size (L*W*H):
284mm x 130mm x 60mm
Product features
rr[0:1!
raY1103NPIOrWAIN, P 4411111I 0 I
AC/OK signal DC/OK signal TTL signal remote control
Output Protections: Overload / Over voltage / Over temperature
/ Short circuit
Input Protections: Over voltage / Under voltage
MTBF: -3100kHrs at 25t
Forced air cooling by built-in DC fan with fan speed
Specifications
Input voltage
Frequency range
Max input an current
Inrush current
Operate Efficiency
Storage temperature
Operating temperature
Operating Humidity
Harmonic current
150-300VAC
50Hz / 60Hz ± 5°.
6A max at full load
30A max. 230VAC
230VAC
-45-85t
-40-70t
10%-95% RH
Meet GB17625.1-1998
IEC61000-3-2 Class D
Less than 0.75mA. 230VAC
Leakage current
Input under voltage
Input over voltage
135-145VAC
300-325VAC
Output Characteristics
P/N
Output voltage
Rated current
Regulation
OVP
UVP
± 2%
±2%
±2%
30.5-34V
10-13V
10-13V
13-20V
6-8.5V
6-8.5V
10-12V
L_
ECP-700
+28V
+9V
+M9V
Battery
20A
10A
5A
0.4A
12.4-12.8
42
OCP U
23-25A
11-13.5A
5.5-7A
INDUSTRY-SPECIFIC POWER SUPPLY
LED DISPLAY POWER SUPPLY SERIES
OP Series
Product features
]
OP-25-5
OP-40-5
4:1 wide input range
Non-isolated
Isolated
Air Cooling
100% full load burn-in test
Input characteristics
Model
OP-25-5
OP-40-5
Input voltage
9-36VDC
18-72VDC
110%-160%
11O% 180%
auto-recovery
Overload protection
-
auto-recovery
Operating temperature
MTBF
-40t-70°C
100kHrs
Safety Standard
200kHrs
Meet LVD
0.1kg/pcs
Weight
0.16kg/pcs
P/N
Output
Tol.
R&N
Effi.
Load Regulation
OP-25-5
5V / 5A
± 5%
75mV
75%
± 3%
P/N
Output
Tol.
R&N
Effi.
Load Regulation
OP-40-5
5V / 8A
± 5%
50mV
77%
j
43
±
3%
d d 83M
2 years warranty
EINV Series
Product features
Balanced lamp current
Open protection and Short circuit protection
High efficiency
Storage Temperature: -25-70°C
Operating Temperature: 0-70t
Storage Humidity: 10%-95% RH, non-condensing
Operating Humidity: 10%-95% RH, non-condensing
1 year warranty
Specifications
Applied for LCD
Dimension (mm)
Input Voltage (V)
For 1 CCFL
For 2 CCFL
7'/8'
10'
120x25x10
10.8-13.2
120x22x10
10.8-13.2
Typical input voltage (V)
Input Current (A) typ.
12
0.5
Lamp current (mA) typ.
Frequency (kHz)
6.5
40-60
12
1.0
6.5
40-60
Vin=12V, Von/off=5V, Vadj=0V
Specifications
For 4 CCFL
Applied for LCD
Dimension (mm)
Input Voltage (V)
Typical input voltage (V)
Input Current (A) typ.
Lamp current (mA) typ.
Frequency (kHz)
For 6 CCFL
15717719'
15717719'
141x41x15
180x45x15
10.8-13.2 / 21.6-26.4
10.8-13.2/ 21.6-26.4
12 / 24
12 / 24
1.8 / 1.0
3.2 / 1.6
6.6
6.6
40-55
40-55
Vin=12V/24V, Von/off=5V, Vadj=0V
44
____
OP Series
UGI
Product features
Universal AC input / Ultra range
Input Protections: Over voltage
Output Protections: Overload / Short circuit
Isolated for each output.
100% full load burn-in test
3 years warranty
Specifications
Input voltage
Input frequency
Operating temperature
Storage temperature
Safety standards
P/N
OP-15D
Output
65-500VAC
47-63Hz
-40-70t
-45-105t
UL60950-1
EMC standards
GB4943-2001
EN55022 Class B, EN55024
Weight
0.11kg/pcs
Tol. R & N Effi.Load Regulation
± 4% 50mV 77%
±2%
±2%1 00mVI77%
12V, 4.2A
±1%
5.3V, 10A
ECU Power Supply series are all models of great demand in market, and we are still optimizing and developing more
suitable products to meet customers needs. Thanks for your attention.
OP Series
Product features
Universal AC input / Ultra range
Input Protections: Over voltage
Output Protections: Overload / Short circuit
Isolated for each output.
100% full load burn-in test
3 years warranty
•
Specifications
P/N
OP-18T
Input voltage
Input frequency
150-500VAC
47-63Hz
Operating temperature
Storage temperature
Safety standards
EMC standards
-40-70t
-45-105t
UL60950-1
GB4943-2001
Weight
EN55022 Class B, EN55024
0.11kg/pcs
Output
To!.
R&N
Effi.
Load Regulation
5.3V, 10A
±4%
50mV
80%
± 2%
12V, 4.2A
±2%
.100mV
80%
±2%
13V, 0.5A
±2%
100mV
80%
±2%
From July.2006 ECU upgraded its producing lines to be lead—free. You can use any of them with assurance that our power supplies
are 100% ROHS compliant.
1:11
EUP Series
Product features
Universal AC input! full range
PF>0.95
Power on indication
Air cooling
Protection: Overload / Over voltage / Short circuit
100% full load burn-in test
2 years warranty
Specifications
Input voltage
Input frequency
90VAC-264VAC
47-63Hz
70A@230VAC
Inrush current
Hold up time
Overload protection
Over voltage protection
Operating temperature
Safety standards
EMC standard
Withstand voltage
35A@110VAC full load cold start
__20ms@230VAC full load
105%-150% auto-recovery
105%-140%
-20-70t (refer to output load derating curve)
UL60950-1, EN60950-1
EN55022 Class B, EN55024
1/P-0/19: 1.5kVAC,1min
I/P-FG: 1.5kVAC,1min
0/P-FG: 0.5kVAC,1min
0.55kg/pcs
Weight
P/N
Output
Tol.
R&N
Effi.
EUP-200-24
24V, 0-8.3A
± 2.5%
400mV
90%
Load Regulation
9W-21W
22W-25W
40W-60W
14W-21W
14W-21W
25W-40W
14W-21W
30W-50W
300-50TMulti-output
60W-100W
30W-50WDimmable
30W-50W
50W-100W
60W-75W
120W-150W
180W-200W
120W--1 50WDimmable
45W-60WAdjustable
80W-100WAdjustable
180WAdjustable
60W-80W
100W-120W
120W-150W
180W-200W
• New productDeveloping
14(*i
w.,(€
CB
KEN 3:Za,Anus
US
As ECU LED Driver has formed a fairly complete system with rich content, we have also made the special catalog for our
LED driver series for customers° detailed reading. Please contact our sales department and agency for it if you need.
Since our products are being kept updating all the time, you can find the latest products information on our website.
•
According to different situations of application, our security series power supplies have two types-the full range
input voltage and single input voltage for customers choice. Its limit charging protection mode can effectively
prevent the overcharge of the battery so as to guarantee the usage safety.
•
ECU also offers customizing power supplies according to different industries specific demands. We welcome
your communicate with our engineers to provide you with the most suitable solution.
•
ECU's power supplies have high reliability because all of them must pass through 100% burn-in test, which
lasts for four hours.
•
Open frame power is commonly made to meet custom needs, such as dimension to fit the internal space of
clients' machine. Considering the delivery and price, we suggest you to use standard ones in our manual.
Meanwhile, we also accept customization.
•
The lead-time is 2-3 weeks for general standard products, 3-8 weeks for customized samples.
•
From July.2006 ECU upgraded its producing lines to be lead-free. You can use any of them with assurance that
our power supplies are 100% ROHS compliant.
WWI klir
■■■ 1 ,101111
1.111i 1,11i,
■ 111,1 1..1 ID
.1 LI I, 11,,,11‘1,.
CERTIFICATE
REIF II at a1* NC id, II ill 4S
...tr.. IN,
ECL f_leams. lad*
.1.fl I I 41101
111...•TS.111.,.--11.1[1.11.11M4
iik26 •■•.• . Low ...1111112.rnatla
.11.•
14111111.41..
am BAM1111.1.1, 2117.1111.•
ONSAS S11.110.014.}.
=
441111.1,1411V.,
, .
CERTIFICATE
...la
Go*.
Certificate of Compliance
g
A
=71
e., •■ 1.6
" _14
V- •
•
■,,,
/Irep.Men ittreal... we alp. Iv Mar Mr
kfivt
or, 8 w I.M.e.e■er
au)veule Mron M.( SVw f
to•M IV .. 13 ow& ...AverriMerin•aurr•• (*wile . au(
.Ttfr. ltdr-
--
At)
•
ripe. 4,1
•
,
•
ECU devotes to service our customers with power supplies and solutions of high efficiency and high reliability.
If our catalog products cannot meet your requirements, please contact our sales for more information.
•
ECU Power Supply series are all models of great demand in market, and we are still optimizing and developing
more suitable products to meet customers' needs. Thanks for your attention.
IS` 11M WI
I 1111 M /Z
17 ECU ELECTRONICS INDUSTRIAL CO.,LTD.
Address: No.41 TianZhi Rd, Huadian Building,
Hefei, 230088, Anhui, China
Tel: 86-551-5311411 86-551-2368818
Fax: 86-551-5324417 ext 0
E-mail: [email protected]
Http://www.ecu.com.cn