TR11 Series

E209569
up to 12 Amps
UL1077 Recognized
Supplementary Protector/
Circuit Breaker for Equipment
Applications:
Protection of Control Transformers, UPS, Power
strips, Solenoids etc., against damage due to
overload conditions.
Current Rating
0.5 -16.0A
Rated Voltage
240V AC, 50/60Hz, 32V DC / 24V DC (VDE)
Initial insulation resistance
Power Loss
Operating Temperature
Operational Life at 2xIn
Limited short circuit current
(As per EN 60934)
> 100 M ohms.
(As per EN 60934)
1.5 KV for One minute.
6 In ~ up to 9.0A
(As per EN 60934)
4 In - up to 12.0A
60A Max. ~ from 10.0A to 12.0A
60A Max. - from 10.0A to 12.0A
8x In for <6.0A
60A MAX. for > 6.0A
1 - 2 Watts
Maximum 60°C Ambient
1000 Cycles
1000 Amps PC 1
Terminals
0.25” Quick connect
Applicable Standards
EN 60934, CSA 22.2 No. 235, UL-1077
Dielectric strength
Overload Switching Capacity
Maximum Breaking Capacity
up to 16.0 A
Approvals
Accessories
18
(min) 60
30
20
10
5
1
(S) 50
20
upto 12.0A
10
Dust Cover, DC-TR11 C (see page 20)
5
Time Current Characteristics:
The standard characteristic is valid for ambient temperatures of
+23°C. If the device is to be used in an ambient temperature other
than +23°C, allowances must be made when selecting the current
rating according to the following guidelines:
Ambient temp. °C
-20
0
+10
+20
+30
+40
+50
+60
Correction Factor
0.8 0.88 0.9
0.96
1
1.05
1.12
1.2
1.3
Example :
Operating
Characteristic
-5
Normal Continuous Current
Ambient Temperature
Correction Factor
Recommended Current Rating
Select the nearest
:
:
:
:
:
1.8A
40°C
1.12
1.8 x 1.12 = 2.016
2.0A
2
1
Trip time
Altech UL1077
TR11 Series
0.5
0.2
0.1
1.05 1.32
2
3
4 5
8 10
Multiple of Rated Current
Rated current
Ambient
Temperature
<6A
>6A
23°C
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
TR-11 Characteristics
& Mounting Options
Central
Mounting
Standard Pack: 10
Weight:
0.27kg (0.6 lb.)
Snap
Fitting*
E209569
Rated
Current
0.5A
0.9A
1.0A
1.2A
1.5A
1.8A
2.0A
2.2A
2.5A
2.7A
3A
3.3A
4A
5A
6A
6.5A
7A
8A
9A
10A
12A
15A
16A
Type/
Cat. No.
TR-11CX630.5A
TR-11CX630.9A
TR-11CX631A
TR-11CX631.2A
TR-11CX631.5A
TR-11CX631.8A
TR-11CX632A
TR-11CX632.2A
TR-11CX632.5A
TR-11CX632.7A
TR-11CX633A
TR-11CX633.3A
TR-11CX634A
TR-11CX635A
TR-11CX636A
TR-11CY636.5A
TR-11CY637A
TR-11CY638A
TR-11CY639A
TR-11CY6310A
TR-11CY6312A
TR-11CY6315A
TR-11CY6316A
Rated
Current
Type/
Cat. No.
up to 12 Amps
Rated
Current
Type/
Cat. No.
Rated
Current
Type/
Cat. No.
Wing
Clips*
Standard Pack: 10
Weight:
0.27kg (0.6 lb.)
Integral
Mounting*
Standard Pack: 10
Standard Pack: 10
Weight:
0.27kg (0.6 lb.)
Weight:
0.27kg (0.6 lb.)
* SPECIAL ORDER ONLY. Contact Altech for more details.
PCB Mounting and additional Shunt Terminal available, please contact Altech.
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
Altech UL1077
Application Examples:
Protection of Control Transformers, UPS,
Power strips, Solenoids etc., against
damage due to overcurrent conditions.
19
Central Mounting
10
MAXIMUM TORQUE 0.5 Nm
9
6
10.8/12
13.3/14.5
PANEL CUTOUT
19
27.5
9
7
8.7
10.2
11
M10 X 1
3
DIA 4
A/F 13
0.8
DIA 4
9.4
10.2
Alternate 1
Alternate 2
15
Wing Clips
3
15.5
27.5
11
PANEL CUTOUT
15 9+0.1
12
Ø1
5 .5
DIA 12
14.5
Altech UL1077
TR-11
Dimensions & Mounting Options
19
7
12.7
15.2
13.9 +0.1
0.8
DIA 4
12
PANEL CUTOUT
X +0.1
2
21.7
.2
7
11
11.3 +0.1
14
25.6
11.2
13
8.5
Snap Fitting
15
0.8
9
10
27.5
19
7
11
11.2
DIA 4
85
Integral Mounting
15
0.8
15
Dust Cover
2
18
Cover is suitable for central mounting type
circuit breaker to provide dust & splash
protection (IP 54).
Type/Cat. No.: DC TR11 C
M10 X 1
DIA 16
Dimensions in mm (to convert to inches multiply by 0.03937)
20
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com