PQM1-M Datasheet - DC-DC CONVERTER | CUI Inc

For more information, please visit the product page.
date
04/08/2014
page
1 of 6
SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
1 W isolated output
smaller package
single regulated output
1,500 Vdc isolation
continuous short circuit protection
extended temperature range (-40~85°C)
high efficiency at light load
efficiency up to 75%
input
voltage
MODEL
output
voltage
output
current
output
power
ripple
and noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
typ
(mVp-p)
typ
(%)
PQM1-S5-S3-M
5
4.75~5.25
3.3
25
243
0.8
50
58
PQM1-S5-S5-M
5
4.75~5.25
5
20
200
1
50
72
PQM1-S5-S9-M
5
4.75~5.25
9
12
111
1
50
74
PQM1-S5-S12-M
5
4.75~5.25
12
9
84
1
50
73
PQM1-S5-S15-M
5
4.75~5.25
15
7
67
1
50
74
PQM1-S12-S5-M
12
11.4~12.6
5
20
200
1
50
73
PQM1-S12-S9-M
12
11.4~12.6
9
12
111
1
50
74
PQM1-S12-S12-M
12
11.4~12.6
12
9
84
1
50
73
PQM1-S12-S15-M
12
11.4~12.6
15
7
67
1
50
75
PQM1-S24-S5-M
24
22.8~25.2
5
20
200
1
50
73
PQM1-S24-S9-M
24
22.8~25.2
9
12
111
1
50
74
PQM1-S24-S12-M
24
22.8~25.2
12
9
84
1
50
73
PQM1-S24-S15-M
24
22.8~25.2
15
7
67
1
50
74
Note:
1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
PART NUMBER KEY
PQM1 - SXX - S XX - M - X
Base Number
Input Voltage
Output
S = single
cui.com
Output Voltage
Packaging Style
"blank" = tube
TR = tape & reel
For more information, please visit the product page.
CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/08/2014 │ page 2 of 6
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
5 Vdc input models
12 Vdc input models
24 Vdc input models
4.75
11.4
22.8
5
12
24
5.25
12.6
25.2
Vdc
Vdc
Vdc
surge voltage
for maximum of 1 second
5 Vdc input models
12 Vdc input models
24 Vdc input models
-0.7
-0.7
-0.7
9
18
30
Vdc
Vdc
Vdc
filter
capacitance filter
max
units
±0.25
%
OUTPUT
parameter
conditions/description
min
line regulation
for Vin change of 1%
load regulation
measured from 10% load to full load
3.3 Vdc output models
all other models
voltage accuracy
at 100% load
switching frequency
at 100% load, nominal input voltage
temperature coefficient
at 100% load
typ
3
1
100
%
%
±3
%
300
kHz
±0.03
%/°C
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous, automatic recovery
min
typ
max
units
min
typ
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output for 1 minute at 1 mA max.
1,500
Vdc
isolation resistance
input to output at 500 Vdc
1,000
MΩ
conducted emissions
CISPR22/EN55022 class B (external circuit required, see Figure 1)
radiated emissions
CISPR22/EN55022 class B (external circuit required, see Figure 1)
ESD
IEC/EN61000-4-2, class B, contact ± 8kV
MTBF
as per MIL-HDBK-217F @ 25°C
RoHS
2011/65/EU
3,500,000
hours
ENVIRONMENTAL
parameter
conditions/description
operating temperature
see derating curve
min
storage temperature
storage humidity
non-condensing
temperature rise
at full load, Ta = 25°C
typ
max
-40
85
°C
-55
125
°C
95
25
cui.com
units
%
°C
For more information, please visit the product page.
CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/08/2014 │ page 3 of 6
SOLDERABILITY
parameter
conditions/description
max
units
hand soldering
1.5 mm from case for 10 seconds
min
300
°C
reflow soldering
see reflow soldering profile
245
°C
max
units
Temperature(°C)
2 50
2 45
2 17
2 00
typ
°C ( M a x .)
P e a k . Te m p 2 4 5 6 0 S e c M ax
( > 2 1 7°C )
1 50
1 00
50
0
Time (sec.)
MECHANICAL
parameter
conditions/description
dimensions
15.24 x 11.20 x 7.25 (0.600 x 0.441 x 0.285 inch)
min
case material
epoxy resin (UL94-V0)
weight
typ
mm
2.0
g
MECHANICAL DRAWING
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
PIN CONNECTIONS
PIN
FUNCTION
1
GND
2
Vin
4/5
0V
7
+Vo
10
NC
NC: No Connection
Top View
Top View
PCB Layout
Side View
Front View
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/08/2014 │ page 4 of 6
DERATING CURVE
Temperature Derating Curve
Load (%)
100
80
60
Safe operating area
40
20
-40
-20
0
20
40
60 71
85
100
Ambient Temperature (°C)
EMC RECOMMENDED CIRCUIT
Figure 1
V in
LDM
C1
GND
Table 1
Recommended external circuit components
V in
+Vo
DC DC
GND
C2
LOAD
0V
cui.com
Vout
(Vdc)
C1
C2
LDM
3.3
4.7μF/50V
10μF
6.8μH
5
4.7μF/50V
10μF
6.8μH
9
4.7μF/50V
4.7μF
6.8μH
12
4.7μF/50V
2.2μF
6.8μH
15
4.7μF/50V
1μF
6.8μH
For more information, please visit the product page.
CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/08/2014 │ page 5 of 6
APPLICATION NOTES
1.
Output load requirement
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2.
Overload Protection
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add
this is to add a circuit breaker to the circuit.
3.
Recommended circuit
If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low
ESR (see Figure 2 & Table 2). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too
high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance
must be less than the maximum capacitive load (see Table 3).
Figure 2
+Vo
V in
DC
Cin
DC
Cout
GND
0V
Table 2
Vin
(Vdc)
Cin
(μF)
Vo
(Vdc)
Cout
(μF)
Vout
(Vdc)
5
4.7
3.3
10
3.3
220
12
2.2
5
10
5
220
24
1
9
4.7
9
220
--
--
12
2.2
12
220
--
--
15
1
15
220
Note:
Note:
Table 3
Max. Capacitive Load
(μF)
It’s not recommended to connect any external capacitors in
applications with less than 0.5 watt output.
1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.
2. Max. capacitive load tested at input voltage range and full load.
3. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/08/2014 │ page 6 of 6
REVISION HISTORY
rev.
1.0
description
date
initial release
04/08/2014
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.