ETSA Datasheet - AC-DC POWER SUPPLY | CUI Inc

For more information, please visit the product page.
date
11/20/2014
page
1 of 8
SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY
60 W power
universal input (90~264 Vac)
compact size
single regulated output from 12~24 V
over voltage and short circuit protections
UL/cUL, Intertek and PSE safety approvals
level V efficiency
custom designs available
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
5
60
200
V
3.42
60
240
V
2.7
60
240
V
ETSA120500U
12
ETSA190342U
19
ETSA240270U
24
efficiency
level
1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors.
O
PART NUMBER KEY
N
Notes:
TI
MODEL
N
U
•
•
•
•
•
•
•
•
ED
FEATURES
D
IS
C
ETSA120500U X - XX - SZ - CXX
Base Number
example of 12 Vdc, 5 A
DC Plug Type:
see output plug options
on page 7
Factory
Input Cable:
“Blank” = No Cable
C = North American input cable
2 = European input cable
3 = United Kingdom input cable
4 = Australian input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
cui.com
Designation
Reserved for Custom
Configurations
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/20/2014 │ page 2 of 8
INPUT
parameter
conditions/description
min
voltage
typ
90
47
inrush current
12 V output
all other outputs
leakage current
12 V output
all other outputs
no load power consumption
12 V output
all other outputs
U
OUTPUT
parameter
conditions/description
min
line regulation
PROTECTIONS
conditions/description
over voltage protection
output voltage clamped by internal protection
zener
short circuit protection
output shut down, auto restart
TI
parameter
parameter
Vac
63
Hz
typ
1.4
1.5
A
A
0.35
0.25
mA
mA
0.3
0.5
W
W
max
units
±1
%
±5
%
N
load regulation
SAFETY & COMPLIANCE
units
264
ED
frequency
max
conditions/description
min
typ
max
units
1,500
Vac
input to output at 10 mA for 1 minute
input to output at 500 Vdc
safety approvals
UL/cUL (UL 60950-1), EN 60950-1/IEC 60950-1, PSE
EMI/EMC
FCC part 15, subpart b, class B; CE; CISPR 22, class B; ICES-003; ANSI C63.4; EN 61204-3; EN
55022; EN 55024; EN 61000-(2, 3); IEC 61000-4-(2, 3, 4, 5, 6, 8, 11)
RoHS
2011/65/EU
O
N
isolation voltage
insulation resistance
100
MΩ
ENVIRONMENTAL
parameter
max
units
0
40
°C
storage temperature
-10
70
°C
operating humidity
20
80
%
storage humidity
10
90
%
min
D
IS
C
operating temperature
conditions/description
cui.com
typ
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/20/2014 │ page 3 of 8
MECHANICAL
conditions/description
114 x 47 x 32.4 (4.488 x 1.850 x 1.276 inches)
min
input plug
IEC320 / C14
max
units
mm
230
weight1
Notes:
typ
ED
parameter
dimensions
1. weight does not include AC Cord
MECHANICAL DRAWING
D
IS
C
O
N
TI
N
U
units: mm
tolerance: ±1mm
cui.com
g
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/20/2014 │ page 4 of 8
DC CORD
ED
cord length
U
S&T
CABLE GAUGE
CORD LENGTH
16 AWG
1,000 mm ±100
ETSA190342U
18 AWG
1,530 mm ±100
ETSA240270U
18 AWG
1,530 mm ±100
N
MODEL NO.
ETSA120500U
NORTH AMERICAN INPUT CABLE
Ĭijıı
IJĹĴıĮĴı
IS
C
O
N
units: mm
TI
AC CORD
EUROPEAN INPUT CABLE
ń
ŏ
ō
ĵ
D
IJķ
ijĶıŗ ſ
ŚńĮIJij
ŏİIJĵĹĸĸ
ŚőĮijĴ
units: mm
Ĭijıı
ĮĴı
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/20/2014 │ page 5 of 8
AC CORD (CONTINUED)
UNITED KINGDOM INPUT CABLE
units: mm
ŏ
ED
ń
ŏİIJĵĹĸĸ
ŚńĮIJij
ō
ĵ
U
+200
1830 -30
AUSTRALIAN INPUT CABLE
N
TI
ŏ
ŚőĮĴĶ
ō
ņ
N
O
IS
C
D
units: mm
BLACK INSULATION
1830 ±30
cui.com
ĵ
SOUTH KOREA INPUT CABLE
ō
+200
1830-30
ŏ
units: mm
ń
CHINA INPUT CABLE
ŚńĮIJij
+200
1830-30
ŏİIJĵĹĸĸ
ŏİIJĵĹĸķġIJıłġijĶıŗſ
units: mm
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/20/2014 │ page 6 of 8
AC CORD (CONTINUED)
BRAZIL INPUT CABLE
ED
units: mm
U
1830±30
SOUTH AFRICA INPUT CABLE
TI
N
units: mm
1830±30
D
IS
C
units: mm
O
JAPAN INPUT CABLE
N
1830±30
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/20/2014 │ page 7 of 8
OUTPUT PLUG OPTIONS
14±0.5
ED
ø3.5 +0/-0.1
ø3.5 +0/-0.1
3.5 mm Phono Plug
14±0.5
*Tip positive
P1
P1R
C
Right Angle PXR
Standard PXX
B
A
O
IS
C
B
N
B
A
C
C
A
B
C
Unit
5.5
2.1
9.5
mm
P6/P6R
5.5
2.5
9.5
mm
P7/P7R
3.5
1.35
9.5
mm
P8/P8R
3.8
1.35
9.5
mm
P9/P9R
3.8
1.05
9.5
mm
TI
Locking DC Plug
EIAJ Plugs
P5/P5R
N
Standard PX
B
A
B
A
C
A
U
Standard DC Plug
A
B
C
Unit
P10
5.5
2.1
9.5
mm
P11
5.5
2.5
9.5
mm
EIAJ
A
B
C
P12/P12R
EIAJ-1
2.35
0.7
P13/P13R
EIAJ-2
4.0
1.7
P14/P14R
EIAJ-3
4.75
1.7
C
Right Angle PXXR
D
Stripped and Tinned
25±5
9±2
D
DC PLUG TYPE
PXX X X
Plug Type:
PXX = See above plug options
ST = Stripped and Tinned
Plug Angle:
“blank” = Straight
R = Right Angle
*Contact CUI for additional plug options
cui.com
Plug Polarity:
P = Center Positive
N = Center Negative
D
Unit
9.5
NA
mm
9.5
5.0
mm
9.5
5.0
mm
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/20/2014 │ page 8 of 8
REVISION HISTORY
description
date
1.0
initial release
12/05/2011
1.01
updated P7/P7R B dimension, V-Infinity branding removed, safety and
EMI/EMC data updated
08/15/2012
1.02
updated DC Cord information
11/14/2012
1.03
updated series number
1.04
added ac cord options
ED
rev.
11/20/2012
11/20/2014
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.