datasheet

Current Transducer HASS 50..600-S
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 50 .. 600 A
All Data are given with a RL = 10 kΩ
Electrical data
Primary nominal
current rms
IPN (A)
50
100
200
300
400
500
600
VOUT
GTH
VREF
RL
ROUT
CL
V C
IC
Primary current
Type
measuring range
IPM (A)
± 150
± 300
± 600
± 900
± 900
± 900
± 900
HASS 50-S
HASS 100-S
HASS 200-S
HASS 300-S
HASS 400-S
HASS 500-S
HASS 600-S
Analog Output voltage @ IP
Theoretical sensitivity Reference voltage 1) Ouput voltage
Ouput impedance
Load impedance
Load resistance
Output internal resistance
Capacitive loading (± 20 %)
Supply voltage (± 5 %)2)
Current consumption @ VC = 5V
Features
VOE ± (0.625. IP/ IPN) V
0.625
V/ IPN
2.5 ± 0.025
V
typ. 200
Ω
≥ 200
Ω
≥ 2
kΩ
< 5
Ω
= 4.7
nF
5
V
19
mA
Accuracy - Dynamic performance data
Accuracy 3) @ IPN , TA = 25°C
εL
Linearity error
0 .. IPN
0 .. IPM
TCVOE Temperature coefficient of VOE (+25.. +85°C)
(-40.. +25°C)
TCVREF Temperature coefficient of VREF
(+25.. +85°C)
(-40.. +25°C)
TCVOE/VREFTemperature coefficient of VOE /VREF TCG
Temperature coefficient of G VOE Electrical offset voltage @ IP = 0, TA = 25°C VOM Magnetic offset voltage @ IP = 0
after an overload of IPM
tra
Reaction time to 10 % of IPN step
tr
Response time to 90 % of IPN step
di/dt
di/dt accurately followed
Vno Output voltage noise (DC .. 10 kHz)
(DC .. 1 MHz)
BW
Frequency bandwidth (- 3 dB) 4)
X
Notes:
≤ ± 1
%
≤ ± 0.5
%
≤ ± 1
%
≤ ± 0.4
mV/K
≤ ± 0.525
mV/K
≤ ± 0.01
%/K
≤ ± 0.015
%/K
≤ ± 0.15
mV/K
≤ ±0.05% of reading//K
VREF ± 0.025
V
< ± 0.4
< 3
< 5
> 100
< 20
< 40
DC .. 50
%
µs
µs
A/µs
mVpp
mVpp
kHz
●● Hall effect measuring principle
●● Galvanic isolation between
primary and secondary circuit
●● Isolation test voltage 3300 V
●● Low power consumption
●● Single power supply + 5 V
●● Fixed offset & Gain
●● Isolated plastic case recognized
according to UL 94-V0.
Advantages
●● Easy installation
●● Small size and space saving
●● Only one design for wide current
ratings range
●● High immunity to external
interference
●● Internal & external reference.
Applications
●● AC variable speed drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Application domain
●● Industrial.
It is possible to overdrive VREF with an external reference voltage
between 1.5V - 2.8V providing its ability to sink or source approximately 5 mA.
2)
Maximum supply voltage (not operating) < 6.5 V
3)
Excluding Offset and Magnetic offset voltage
4)
Small signal only to avoid excessive heatings of the magnetic core.
1)
Page 1/3
120323/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Current Transducer HASS 50..600-S
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
Standards - 40 .. + 85
- 40 .. + 85
55
EN 50178:1997
°C
°C
g
Isolation characteristics
Vb
Rated isolation voltage rms with following conditions
-Over voltage category Ⅲ
-Pollution degree 2
-Heterogeneous field
Single insulation
Reinforced insulation
Vd
Ve
Vw
dCp
dCl
CTI
EN50178
600V
300V
Rms voltage for AC isolation test, 50 Hz, 1 min
Partial discharge extinction voltage rms @ 10 pC
Impulse withstand voltage 1.2/50 µs
Creepage distance
Clearance distance
Comparative Tracking Index (Group I)
IEC61010-1
600V
150V
3.3
> 1
6
> 5.5
> 5.5
> 600
kV
kV
kV
mm
mm
V
Safety
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
120323/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HASS 50..600-S (in mm)
Mechanical characteristics
●●
●●
●●
●●
●●
General tolerance
± 0.5 mm
Aperture for primary conductor 20.4x10.4x0.5mm
Transducer fastening
M4
Recommended fastening torque <1.5N・m
Connection of secondary
Molex 5045-04A
Remarks
●● Arrow indicates positive current flow direction.
●● Temperature of the primary conductor should not exceed
100°C.
Page 3/3
120323/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com