APPLIKATION, D918, Baumer_D918_DS_EN_1512.pdf, 771 KB

D918
Flanged chemical seals
Main Features
„„
Pressure range from 10 mbar
to 420 bar
„„
Flange class 1500/2500
„„
NPS 1/2" to 2"
„„
Temperature -40 °C to +400 °C
„„
Stainless steel 1.4404 NACE
„„
Pressure, level or flow meas-
urement
„„
Mounted on differential,
absolute or gauge pressure
transmitters.
Applications
„„Oil & Gas / Chemical
„„Energy
Technical Data
Filling liquids
Suitable for high temperature
Capillary
1.5 to 15 m
Process flange
Class 1500/2500 as per EN1759-1 or
ANSI B16-5 NPS 1/2" to NPS 2" / DN15 to DN50
Raised face (B/RF) or ring joint face (J/RTJ)
Integrated steam tracing circuit: 1/4 NPT inlet/
outlet, Ø 8 mm drilling
Bolts ISO (metric) or ASME (UNC)
Drain/vent valve
Class 1500: stainless steel needle valve SW¼"
OD10
Class 2500: double block needle valve SW½"
OD12
Maximum pressure
Depending on class, temperature and material
(see tables page 2 and page 3)
CE conformity
PED 97/23/CE
ATEX 94/9/CE
Material
Upper part
Forged Stainless steel 1.4404 EN 10222-5
Compliant with NACE MR 0103 or MR 0175
Diaphragm
Stainless steel (1.4435) or Hastelloy C276 (2.4819)
Active diameter 95 mm
Internal Sealing joint Ring Joint R32 316L
The ring joint is also supplied in case of delivery
of the chemical seal alone without the process
flange.
Capillary
Length 1.5 - 3 - 4.5 - 6 - 9 - 12 and 15 meters
Stainless steel capillary tube and protection
White plastic outer sheath UL94V0
Process flange
Forged stainless steel 1.4404 EN 10222-5
Compliant with NACE MR 0103 or MR 0175
Chemical seal side
ASTM A193 B8M cl.2/A194 8M
Process side
ASTM A193 B7M/A194 2HM
Bolting
Filling liquid
Category III
Ex II 2 GD c (the associated transmitter must
comply with the ATEX zone where it is used)
LRS8: 0...300°C (for vacuum and absolute
pressure)
LRS9: -40...400°C (high temperature oil)
Other liquids on request
Design and specifications subject to change without notice
Measurement ranges Gauge or differential pressure: 10 mbar min.
Absolute pressure: 50 mbar min.
Temperature
-40 °C ... +400 °C
Options
• 0393 mounting on high pressure side (HP) 1)
• 0385 mounting on low pressure side (LP) 1)
Only for differential transmitters with :
- only 1 seal mounted
- 2 different seals mounted on LP and HP side
• Capillary with low-temperature controlled electric heat tracing
• Reduce influence of environmental temperature
• Improve response time for long capillary
• Decrease in effects of outside temperature :
at −40 °C capillary tube temperature over +30 °C
at +40 °C capillary tube temperature below +60 °C
• Approx. Ø 25 mm heat insulation
• Sealed outer sheath
Capillary
Flange material
www.baumer.com
2015-09-14
1)
Please contact Baumer for other material
Data sheet A42.17
Page 1 / 4
D918
Flanged chemical seals
Dimensions (mm)
D918 class 1500
116 to 135
OD
10
Vent valve
Hanger ring
0
h.8
sc
ØD
1/4
ØK
Ø 230
N x Ø L1
50
100
10
0
Axial
output
1/4 sch.80
98
Option
Side output
50
Steam tracing
1/4NPT
Drain valve
OD 10
Flange dimensions (mm)
DN
Class
ØK
ØL1 ISO
ØL1
ASME
N
Weight
kg
N° GRTJ (1)
15
1500
82.6
M20
3/4" UNC
4
34
R 12
1500
88.9
M20
3/4" UNC
4
35
R 14
1500
101.6
M24
7/"8 UNC
4
36
R 16
1500
123.8
M27
1" UNC
4
40
R 20
1500
165.1
M24
7/8" UNC
8
44
R 24
1/2"
20
3/4"
25
1"
40
1"1/2
50
2"
(1)
Number of the RTJ groove in case of RTJ flange on process side. Gasket not supplied.
Max pressure (bar) / Temperature / Material / Class 1500
Class
20°C
50°C
100°C
150°C
200°C
250°C
300°C
350°C
1.4404 / EN 10222-5
1500#
228
217
199
182
164
152
142
136
130
1.4541 / EN 10222-5
1500#
240
229
211
200
188
176
163
150
150
150
400°C
1.4539 / EN 10272
1500#
250
250
246
228
210
192
174
162
1.4462 / EN 10222-5
1500#
250
250
250
236.4
222.2
211.7
-
-
-
1.4410 / EN 10222-5
1500#
250
250
250
250
239.9
227.9
-
-
-
Monel 400
N04440 according to ASME SB-564
1500#
176.1
165
153.2
145
139.8
139.8
139.8
139.8
137.8
Hastelloy
N10276 according to ASME SB-564
1500#
250
250
250
243.7
228.3
213.9
201.6
192.3
185.1
ASME SA-350 gr. LF2
1500#
250
250
231.9
226
219.2
208.7
193.6
184.8
172.5
2015-09-14
The maximum working pressure can be limited by the characteristics of the piping customer side (standard and class of the flange, material, gasket...)
Design and specifications subject to change without notice
Temperature
Material
www.baumer.com
Data sheet A42.17
Page 2 / 4
D918
Flanged chemical seals
Dimensions (mm)
D918 class 2500
Vent valve
121 to 141
O 250
"
12
N x O L1
100
OD
or
1/2
Hanger ring
’’
1/2
OK
OD
SW
Axial output
SW 1/2’’
130
Option
Side output
50
0
10
Steam tracing
1/4NPT
OD 12 or 1/2"
Drain valve
Flange dimensions (mm)
DN
Class
ØD
ØK
ØL1 ISO
ØL1 ASME
N
Weight
kg
N° GRTJ (1)
15
2500
250
88.9
M20
3/4" UNC
4
45
R13
2500
250
95.2
M20
3/4" UNC
4
46
R16
2500
250
107.9
M24
7/8" UNC
4
50
R18
2500
250
146.0
M30
1" 1/8 UNC
4
56
R23
2500
250
171.4
M27
1" UNC
8
60
R26
1/2"
20
3/4"
25
1"
40
1"1/2
50
2"
(1)
Number of the RTJ groove in case of RTJ flange on process side. Gasket not supplied.
Class
1.4404 / EN 10222-5
2500#
Temperature
20°C
50°C
100°C
150°C
200°C
250°C
300°C
350°C
400°C
380
362
332
304
274
254
236
226
216
1.4541 / EN 10222-5
2500#
400
382
352
334
314
294
272
260
250
1.4539 / EN 10272
2500#
400
400
400
380
350
320
290
270
250
1.4462 / EN 10222-5
2500#
400
400
400
378.3
355.6
338.7
-
-
-
1.4410 / EN 10222-5
2500#
400
400
400
400
383.8
364.7
-
-
-
Monel 400
N04440 according to ASME SB-564
2500#
294.8
275.1
255.4
233.1
233.1
233.1
233.1
233.1
229.7
Hastelloy
N10276 according to ASME SB-564
2500#
400
400
400
400
376.4
352.7
332.4
317.1
305.1
ASME SA-350 gr. LF2
2500#
400
400
386.6
376.9
365.1
347.7
322.7
308
287.5
The maximum working pressure can be limited by the characteristics of the piping customer side (standard and class of the flange, material, gasket...)
www.baumer.com
Data sheet A42.17
Page 3 / 4
2015-09-14
Material
Design and specifications subject to change without notice
Max pressure (bar) / Temperature / Material / Class 2500
D918
Flanged chemical seals
Ordering details D918
D918
– M
.
.
Vent valve (2)
Model
Top housing material
D9 1 8
0
1
9
E
–
Forged NACE compliant 1.4404 st. steel
M
Capillary type
St. steel tube and protection
St. steel tube and protection and white plastic ATEX sheath
St. steel tube and reinforced protection
St. steel tube and protection, heat-insulated
St. steel tube and protection, traced/heat-insulated
Outlet position
Axial outlet
Side outlet
F
A
D
F
M
P
0
1
Capillary length
1.5 m
3m
4.5 m
6m
9m
12 m
15 m
Instrument connection (1)
G1/2 Female
1/2NPT Female
For ABB 265 DR (D)
For ABB 265 GR - 265 VS (G)
For Honeywell STD 820/830/720/730 (D)
For Honeywell STG 740/770 (G)
For Honeywell STG 84x/87x/88x (G)
For Honeywell STA 840/740 (A)
For SIEMENS SITRANS (D)
For SIEMENS SITRANS (G)
For YOKOGAWA EJX110 (low volumes) capsules M, H, V (D)
For YOKOGAWA EJX 430 (low volumes) (G)
For YOKOGAWA EJX 110 (standard flanges) capsules M, H, V (D)
For YOKOGAWA EJX 310/430 (standard flanges) (A) (G)
For YOKOGAWA EJX 440 (standard flanges) (G)
For YOKOGAWA EJX 130A (D)
Filling liquids
LRS8 vacuum oil
LRS9 high temperature oil
Diaphragm material
St. steel 316L (1.4435)
Hastelloy C276 (2.4819)
St. steel 316L (1.4435) (P < 25 mbar)
Hastelloy C276 (2.4819) (P < 25 mbar)
Diaphragm coating
No coating
Gold 15 µm
ssss
(1)
F
.
E
3
F
6
9
D
G
0
1
0
M
A
L
N
H
J
A
D
E
G
7
8
F
V
P
Q
W
Y
0
0
R
Q
0
2
3
4
6
7
0
5
6
8
9
0
M
2
6
C
D
0
7
.
0
2
6
None
1 SW1/4" OD10 valve (4)
1 SW1/4" OD3/8" valve (4)
Double block needle valve
SW1/2" OD12
Double block needle valve
SW1/2" OD1/2"
Heat tracing circuit (2)
None
With
Bolts (2)
Without flange
ISO (metric) (3)
ASME (UNC)
Process flange face finish (2)
Standard finish
Process flange face type (2)
Without flange
Raised face (RF)
Ring joint face (RTJ)
DN / NPS (2)
Without flange
NPS 1/2" (DN15)
NPS 3/4" (DN20)
NPS 1" (DN25)
NPS 1"1/2 (DN40)
NPS 2" (DN50)
PN / Class (2)
Without flange
Class 1500
Class 2500
Process flange material (2)
Without flange
Forged NACE compliant
1.4404 st. steel
Process flange standard (2)
Without flange
ANSI B16-5
EN 1759-1
(2)
To codify chemical seal delivered without the process flange, select
codes 0. Ex: D918–MD03F967.0000000000
(3)
Except flanges ANSI B16-5
(4)
Only class 1500
2015-09-14
Type of transmitter : D= Differential / G=Gauge/ A=Absolute
0
1
9
E
None
1 SW1/4" OD10 valve (4)
1 SW1/4" OD3/8" valve (4)
Double block needle valve
SW1/2" OD12
Double block needle valve
SW1/2" OD1/2"
Drain valve (2)
Design and specifications subject to change without notice
Flanged chemical seals
www.baumer.com
Data sheet A42.17