Technical Data: RP2E

RP2E
Compact pressure switch Explosion proof
Main Features
„„
Excellent repeatability
„„
Dead band adjustment for regulation
„„
Fix dead band for control and alarm
„„
Resistant to accidental overpressure
„„
Explosion proof Hazardous areas 1, 2, 21, 22
Applications
„„Pneumatic appliances
„„Power generation safety equipment
„„Water treatment
„„Valve and compressor control
Technical Data
Pressure range
0 ... 1 bar to 0 ... 100 bar
Temperature
Process : Ambient : Storage : -40 ... +150 °C
-20 ... +70 °C (T5)
-20 ... +60 °C (T6)
-40 ... +70 °C
Repeatability
± 1% F.S. / constant pressure cycle
CE conformity
Low Voltage Directive LVD 2006/95/EC
ATEX Directive 94/9/EC
IP 66 (EN 60529)
Protection rating
Process Connection Stainless steel 1.4404 (316L)
Diaphragm
Stainless steel 1.4404 (316L)
Scale
Internal graduated scale
Weight
1.8 kg
Housing
Grey painted aluminium housing
Explosion proof
Mounting
2 x M6 x 16 screws
Ground connection
Via internal or external terminal block
Electrical
connection
Via internal terminal block with cable gland
3/4 NPT (ATEX certified) for cable Ø 7 to 12 mm
Electrical function
See ordering code details on page 4
Adjustment
Internal adjustment possible for set point and
dead band
Type examination certificate
LCIE 02 ATEX 6219X
EN 60079-0: 2012 (internal conformity analysis)
EN 60079-1: 2007
EN 60079-31: 2009
Marking
0081
II 2 G D
Ex d IIC T6 or T5 Gb
Ex t IIIC IIC T80 °C or T95 °C Db IP6X
ATEX
Code SETP
Oxygen application
Code 0765
Mounting on 2" pipe
Code 0407
Stainless steel tag plate and wire
Code 9941
2015-11-10
Customer specific set point adjustment
Design and specifications subject to change without notice
Options
www.baumer.com
Data sheet A32.02
Page 1 / 4
RP2E
Compact pressure switch Explosion proof
Principle
A flexible sensing element actuates a microswitch by means of a
piston. The set point is adjusted by means of a compressible spring
installed in opposition.
NC
NC
NC
C
C
C
NO
NO
P
NO
Set point and reset point must be between 10% and 90% of the
selected scale.
Standard factory adjustment
Setpoint at 50% of the scale on falling pressure
NC
C
NC
NC
C
C
NO
Customer speciffic factory adjustment (option SETP)
The following specifications have to be given with the order:
• Setpoint value
• Adjustment on falling or raising pressure
• Dead band value (as needed) when using an adjustable dead band
switch
NO
NO
Adjustable ranges
Micro-switch dead band 1)
Adjustable dead band
Code
bar
bar
bar
41
Fixed dead band
R
L
M-P
U (2xSPDT)
10%
90%
10%
90%
10%
90%
10%
90%
mbar
mbar
mbar
mbar
mbar
mbar
mbar
mbar
N/A
N/A
30
60
120
330
150
300
0 ... 1
0 ... 1.6
42
100 - 200
200 - 550
35
70
150
390
175
350
43
125 - 230
250 - 700
40
80
180
480
200
400
44
150 - 290
320 - 900
45
90
210
540
225
450
0 ... 2.5
0 ... 4
0 ... 10
50
6
45
190 - 350
420 - 1200
50
100
240
630
250
500
0 ... 10
46
260 - 500
600 - 1800
55
110
300
750
275
550
0 ... 4
51
500 - 1000
1250 - 2000
110
200
600
1320
550
1000
0 ... 6
52
550 - 1100
1350 - 2200
110
235
750
1620
550
1175
0 ... 10
53
650 - 1300
1500 - 2600
120
270
840
2010
600
1350
54
800 - 1600
1700 - 3100
130
305
960
2370
650
1525
40
100
0 ... 16
0 ... 25
55
1000 - 2000
2000 - 3900
140
340
1050
2730
700
1700
0 ... 40
56
1400 - 2800
2600 - 5200
150
380
1140
3150
750
1900
0 ... 10
61
1000 - 2000
3000 - 6000
200
500
1500
3600
1000
2500
0 ... 16
62
1150 - 2300
3500 - 7000
280
700
2100
3960
1400
3500
0 ... 25
0 ... 40
100
200
63
1350 - 2700
4200 - 8400
360
900
2700
5500
1800
4500
64
1700 - 3400
5350 - 10700
440
1100
3300
7350
2200
5500
0 ... 60
65
2100 - 4200
6900 - 13800
520
1300
3900
9600
2600
6500
0 ... 100
66
3000 - 6000
10000-20000
600
1500
4500
13200
3000
7500
The value of the dead band is depending on the value of the set point.
This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For adjustable dead band the lower value corresponds to
the dead band spring totally released and the higher corresponds to the dead band spring fully tensed. For other set points the dead band value can be calculated
by linear interpolation between the values at 10% and 90%.
1)
www.baumer.com
Data sheet A32.02
Page 2 / 4
Design and specifications subject to change without notice
P. Max
accidental
2015-11-10
Scale
P. Max
permanent
RP2E
Compact pressure switch Explosion proof
Micro switches characteristics
Switch code
R
L
M
P
U
Fixed dead band
Type
Adjustable
Dead band
Standard
Gold contact
Ultra sensitive
Double
6 Vdc
0.4 ... 10 A
N/A
10 ... 50 mA
0.4 ... 4 A
0.4 ... 10 A
12 Vdc
0.4 ... 10 A
N/A
10 ... 50 mA
0.4 ... 4 A
0.4 ... 10 A
24 Vdc
0.4 ... 5 A
N/A
10 ... 50 mA
0.4 ... 4 A
0.4 ... 6 A
30 Vdc
0.4 ... 5 A
N/A
10 ... 50 mA
0.4 ... 2 A
0.4 ... 6 A
48 Vdc
0.4 ... 5 A
N/A
10 ... 50 mA
N/A
0.4 ... 6 A
110 Vdc
0.2 ... 0.5 A
N/A
10 ... 50 mA
N/A
0.4 ... 0.5 A
220 Vdc
0.1 ... 0.25 A
N/A
10 ... 50 mA
N/A
0.1 ... 0.25 A
115 Vac
0.4 ... 10 A
0.4 ... 10 A
10 ... 50 mA
N/A
0.4 ... 10 A
250 Vac
0.2 ... 10 A
0.2 ... 10 A
N/A
N/A
0.2 ... 10 A
2000 V
2000 V
2000 V
1000 V
2000 V
Dielectric rigidity between contacts and ground
Electrical connections
2 x SPDT
1 x SPDT
NC
COM
NO
Blue
Red
White
NC
Blue
COM
Red
NO
White
Yellow / green
NC
Blue
COM
Red
NO
White
Hazardous areas : zone 1, 2, 21, 22
-20 °C ≤ Ta ≤ +70 °C
Dust IP65
Gases
T° surface
Class
Ta = 60 °C
80 °C
T6
Ta = 70 °C
95 °C
T5
Important : Maximum power dissipation in the case
must not exceed 5 W
Yellow / green
All necessary measures must be taken by the user, to avoid the calorific transfer from the fluid to the apparatus head increasing the head's
temperature to such that it reaches the self-ignition temperature of the gas in which it is used.
Design and specifications subject to change without notice
Dimensions (mm)
2 fixing holes for
M6 screw
ATEX certified
Cable gland (not mounted)
www.baumer.com
2015-11-10
1/4 NPT female
Data sheet A32.02
Page 3 / 4
RP2E
Compact pressure switch Explosion proof
Ordering details RP2E
RP2
Model
Compact pressure switch
RP2
Approvals
ATEX Explosion proof
Type of micro switches
1 SPDT standard change over switch
1 SPDT gold contact change over switch
1 SPDT hermetically ultra sensitive change over switch
1 SPDT change over switch with adjustable dead band
2 SPDT double change over switch
.
–
xx
/
–
E
L
M
P
R
U
.
Process connection
G1/2 male (standard)
1/2 NPT male
1/4 NPT female
1/2 NPT female
Pressure range (bar)
Over pressure max. (bar)
0 ... 1
10
0 ... 1.6
10
0 ... 2.5
10
0 ... 4
10
0 ... 6
10
0 ... 10
10
0 ... 4
40
0 ... 6
40
0 ... 10
40
0 ... 16
40
0 ... 25
40
0 ... 40
40
0 ... 10
100
0 ... 16
100
0 ... 25
100
0 ... 40
100
0 ... 60
100
0 ... 100
100
Options to be added behind the / (see example below)
3
6
8
N
41
42
43
44
45
46
51
52
53
54
55
56
61
62
63
64
65
66
/
Ordering example with options
RP2
–
E
L
.
3
53
/
0765
_
0407
_
9941
Compact pressure switch
ATEX Explosion proof
1 SPDT standard change over switch
Design and specifications subject to change without notice
Process connection G1/2 male
Pressure range 0 ... 10 bar over pressure max. 40 bar
Option: Oxygen application
Option: Mounting on 2" pipe
2015-11-10
Option: Stainless steel tag plate and wire
www.baumer.com
Data sheet A32.02