APPLIKATION, RPPY4, Baumer_RPPY4_DS_EN_1512.pdf, 1.2 MB

RPPY4
Industrial pressure switch with intrinsic safety and
high overpressure resistance
Main Features
„„
High over pressure resistant
„„
Excellent repeatability
„„
Fix dead band for control and alarm
„„
Dead band adjustment for regulation
„„
Intrinsic safety Hazardous area 0, 1, 2
Applications
„„Power generation safety equipment
„„Pressurized chambers control
„„Liquid level control
Technical Data
Pressure range
-50 mbar ... 0 to 0 ... 2500 mbar
Temperature
Process: Ambient: Storage: -15 ... +150 °C
-25 ... +70 °C (T5)
-30 ... +55 °C (T6)
-40 ... +70 °C
Repeatability
± 1% F.S. / constant pressure cycle
CE conformity
Low Voltage Directive LVD 2006/95/EC
ATEX Directive 94/9/EC
Protection rating
IP 66 (EN 60529)
Electrical
connection
Terminal block with plastic cable gland for
Ø 7 to 10.5 mm
Electrical function
See ordering code details on page 5
Adjustment
2 external adjustment screws on top of the case
for set point and dead band
ATEX
Flanges:
Stainless steel 1.4404 (316L)
Diaphragm:Viton®
Scale
Internal. Accuracy on reading ± 5% F.S.
Cover
Zamak blue painted
Captive stainless steel screws
Case
Black Zamak
Mounting
Wall mounting braket
Ground connection
Via internal terminal block
Ci = Negligible ; Li = Negligible
Process connection Stainless steel 1.4404 (316L)
Design and specifications subject to change without notice
Sensing element
Type examination certificate
LCIE 03 ATEX 6123X
EN 60079-0: 2012 (internal conformity analysis)
EN 60079-11: 2012
Marking
0081
IM1
Ex ia I Ma
II 1 G
Ex ia IIC T6 or T5 Ga
Electrical data
Umax = 28 Vdc
Imax = 120 mA
Pmax = 0.84 W
Options
Code SETP
Oxygen application
Code 0765
Mounting on 2" pipe
Code 0407
Electrical connection: stainless steel connector (Souriau)
Code 2298
Mobile plug for stainless steel connector (Souriau)
Code 2249
Stainless steel tag plate and wire
Code 9941
Lead seal of the adjustment screws
Code 8990
2015-11-12
Customer specific set point adjustment
www.baumer.com
Data sheet A32.09
Page 1 / 5
RPPY4
Industrial pressure switch with intrinsic safety and
high overpressure resistance
Principle
A vapour filled sensing element actuates a microswitch by means of
a lever. The set point and the dead band are set by springs mounted
in opposition
NC
NC
NC
C
C
C
NO
NO
NO
Set point and reset point must be between 10% and 90% of the
selected scale.
Standard factory adjustment
Setpoint at 50% of the scale on falling pressure
NC
C
NC
NC
C
C
NO
Customer specific factory adjustment (option SETP)
The following specifications have to be given with the order:
• Setpoint value
• Adjustment on falling or raising pressure
• Dead band value (as needed) when using an adjustable dead band
switch
NO
NO
Electrical connections
2 SPDT
1 SPDT
NC
Blue
COM
Red
NO
White
NC
Blue
COM
Red
NO
Yellow / green
NC
COM
NO
White
Blue
Red
White
Yellow / green
Certified safety
barrier
NO
C
Non hazardous
area
NO
or NC
NC
+
Rc 1
Supply
–
Screen
For max. ambient temperature according to temperature classes T5 and T6 refer to technical data on page 1.
The installation must be made in an intrinsically safe circuit whose certified electrical safety parameters do not exceed any of the values Umax,
Imax and Pmax given in the electrical data on page 1.
2015-11-12
All necessary measures must be taken by the user, to avoid the calorific transfer from the fluid to the apparatus head increasing the head's
temperature to such that it reaches the self-ignition temperature of the gas in which it is used.
Design and specifications subject to change without notice
Hazardous area
Zone 0, 1, 2
www.baumer.com
Data sheet A32.09
Page 2 / 5
RPPY4
Industrial pressure switch with intrinsic safety and
high overpressure resistance
Micro switches characteristics
Switch code
M (K)
C (W)
S
Type
Gold contact
Hermetic
Ultrasensitive
Gold contact
6 Vdc
10 ... 50 mA
5 ... 120 mA
10 ... 50 mA
12 Vdc
10 ... 50 mA
5 ... 66 mA
10 ... 50 mA
24 Vdc
10 ... 33 mA
5 ... 33 mA
10 ... 33 mA
30 Vdc
N/A
N/A
N/A
48 Vdc
N/A
N/A
N/A
110 Vdc
N/A
N/A
N/A
220 Vdc
N/A
N/A
N/A
115 Vac
N/A
N/A
N/A
250 Vac
Dielectric rigidity between contacts and ground
N/A
N/A
N/A
2000 V
1500 V
2000 V
Adjustable ranges
P. Max
accidental
Scale
mbar
Micro-switch dead band 1)
Adjustable dead band
M (K*)
Code
bar
Fixed dead band
C (W*)
S
10%
90%
10%
90%
10%
90%
mbar
mbar
mbar
mbar
mbar
mbar
0
10
101
2 - 25
2.5 - 25
6.5 - 25
7.5 - 25
1.4
1.7
-2
... 10
10
102
1 - 10
1 - 10
N/A
N/A
1
1.1
-5
... 50
10
103
1 - 20
2 - 20
4.5 - 20
5 - 20
1
1.1
-8
... 100
10
104
1.5 - 25
2.5 - 25
5 - 25
10 - 25
1.2
1.4
50
151
12 - 80
20 - 80
25 - 80
40 - 80
7
11
15 - 80
25 - 80
30 - 80
45 - 80
8
11
-50 ... -200... 0
0
... 200
50
152
0
... 400
50
153
17 - 150
30 - 150
35 - 150
50 - 150
9.2
15.4
0
... 1000
50
154
22 - 150
35 - 150
45 - 150
60 - 150
14
19.5
20 - 350
40 - 350
40 - 350
70 - 350
16
25
0
... 700
100
171**
0
... 1500
100
172**
20 - 350
60 - 350
40 - 350
100 - 350
16
25
0
... 2500
100
173**
25 - 350
90 - 350
50 - 350
160 - 350
21
31
The value of the dead band is depending on the value of the set point.
This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For adjustable dead band the lower value corresponds to the
dead band spring totally released and the higher corresponds to the dead band spring fully tensed. For other set points the dead band value can be calculated by linear
interpolation between the values at 10% and 90%.
2015-11-12
1)
Design and specifications subject to change without notice
(*) For version with 2 microswitches lower values of the dead band must be multiplied x 1.5
(**) G1/4 female only
www.baumer.com
Data sheet A32.09
Page 3 / 5
RPPY4
Industrial pressure switch with intrinsic safety and
high overpressure resistance
Dimensions (mm)
125
76.5
=
144
139
=
58
130
5
64
100
45°
Pressure range code: 151 - 152 - 153 - 154
Weight: 6.4 kg
Hex 24
61
Ø 120
2015-11-12
Design and specifications subject to change without notice
G 1/2(M)
G 1/4
12
Ø 145
64
56
Ø 245
Hex 24
Hex 24
Hex 24
Hex 24
G 1/2(M)
Pressure range code: 171 - 172 - 173
Weight: 7 kg
84
Pressure range code: 101 - 102 - 103 - 104
Weight: 10 kg
www.baumer.com
Data sheet A32.09
Page 4 / 5
RPPY4
Industrial pressure switch with intrinsic safety and
high overpressure resistance
Ordering details RPPY4
RP
Model
Industrial pressure switch
Approvals
ATEX intrinsic safety
Sensing element
Diaphragm (Viton ®), high overpressure resistance
Type of micro switches
1 SPDT hermetically changeover switch
2 SPDT hermetically changeover switch
1 SPDT gold contact changeover switch
2 SPDT gold contact changeover switch
1 SPDT ultrasensitive gold contact changeover switch
Process connection
G 1/4 female (only pressure ranges 171, 172, 173)
G 1/2 male (standard)
1/2 NPT male
1/4 NPT female
Pressure range (mbar)
Pressure range (kPa)
-50 ...
0
-5
...
0
-2 ...
10
-0.2 ...
1
-5 ...
50
-0.5 ...
5
-8 ... 100
-0.8 ...
10
-200...
0
-20 ...
0
0 ... 200
0
...
20
0 ... 400
0 ...
40
0 ... 1000
0 ... 100
0 ... 700
0 ...
70
0 ... 1500
0 ... 150
0 ... 2500
0 ... 250
Options to be added behind the / (see example below)
PY
–
4
.
xxx
/
RP
PY
–
4
Deadband
Adjustable
Adjustable
Adjustable
Adjustable
Fix
C
W
M
K
S
H
3
6
8
.
101
102
103
104
151
152
153
154
171
172
173
Process connection G1/4 female
Process connection G1/4 female
Process connection G1/4 female
/
Ordering example with options
RP
PY
–
4
C
3
.
101
/
0407
_
9941
Industrial pressure switch
With ATEX approval intrinsic safety
Diaphragm Viton®
1 SPDT hermetically changeover switch
Process connection G 1/2 male
Design and specifications subject to change without notice
Pressure range -50 ... 0 mbar
Option: Mounting on 2" pipe
2015-11-12
Option: Stainless steel tag plate and wire
www.baumer.com
Data sheet A32.09
Page 5 / 5