APPLIKATION, RDE4, Baumer_RDE4_DS_EN_1512.pdf, 1.2 MB

RDE4 - RDE8
Differential pressure switch, explosion proof
Main Features
„„
Excellent repeatability
„„
Dead band adjustment for regulation
„„
Fix dead band for control and alarm
„„
Explosion proof Hazardous areas 1, 2, 21, 22
Applications
„„Power generation safety equipment
„„Pressurized chambers control
„„Liquid level control
Technical Data
Pressure range
-2.5 ... 2.5 mbar to 2.5 ... 30 bar
Mounting
3 back lugs for wall mounting
Temperature
Pressure range codes 110 to 157
Medium:
-15 ... + 150 °C
Ambient: -20 ... + 55 °C
Storage: -40 ... + 70 °C
Pressure range codes 211 to 258
Medium:
-50 ... + 200 °C
Ambient: -20 ... + 55 °C
Storage: -40 ... + 70 °C
± 1% F.S. / constant pressure cycle
Ground connection
Via internal terminal block
Electrical
connection
Terminal block with metallic cable gland for
Ø 7 to 12 mm standard
Electrical function
See ordering code details on page 5
Adjustment
2 external adjustment screws for set point and
dead band.
When set point adjustment is required it is necessary to know the static pressure, as it has an
influence on the set point.
Type examination certificate
LCIE 03 ATEX 6231X (Type RA80)
EN 60079-0: 2012 (internal conformity analysis)
EN 60079-1:2007
EN 60079-31: 2009
Marking
0081
II 2 G D
Ex d IIC T6 or T5 Gb
Ex t IIIC IIC T80 °C or T95 °C Db IP6X
CE conformity
Protection rating
Low Voltage Directive LVD 2006/95/EC
ATEX Directive 94/9/EC
IP 66 (EN 60529)
Process Connection Stainless steel 1.4404 (316L)
Sensing element
Pressure range codes 110 to 157
Flanges:Stainless steel 1.4404 (316L)
Diaphragm:Viton®
Pressure range codes 211 to 256
Bellow:Stainless steel 1.4404 or
1.4432 (316L)
Scale
Housing
Pressure range codes 257 and 258
Piston:Nickel plated steel
Internal. Accuracy on reading ± 5% F.S.
ATEX
T° ambient
-20 °C to +60 °C (T6 or T80 °C) or
-20 °C to +70 °C (T5 or T95 °C)
Design and specifications subject to change without notice
Repeatability
Type RA80, explosion proof, flameproof
Alumunium epoxy painted.
Captive stainless steel screws
Options
Code SETP
Oxygen application
Code 0765
Lead seal of the adjustment screws
Code 8990
Mounting on 2" pipe
Code 0407
Stainless steel tag plate and wire
Code 9941
2015-11-13
Customer specific set point adjustment
www.baumer.com
Data sheet A32.22
Page 1 / 5
RDE4 - RDE8
Differential pressure switch, explosion proof
Principle
∆P
A flexible sensing element actuates a microswitch by means of a
piston. The set point is adjusted by means of a compressible spring
installed in opposition.
NC
NC
C
C
NC
C
NO
NO
NO
HP > LP
HP < LP
Set point and reset point must be between 10% and 90% of the selected scale.
Standard factory adjustment
Setpoint at 50% of the scale on falling pressure
NC
C
NO
NC
NC
C
C
NO
NO
Customer speciffic factory adjustment (option SETP)
The following specifications have to be given with the order:
• Setpoint value
• Adjustment on falling or raising pressure.
• Static pressure
• Dead band value (as needed) when using an adjustable dead band
switch
Electrical connections
2 SPDT
1 SPDT
NC
COM
NO
Blue
Red
White
NC
Blue
COM
Red
NO
White
NC
Blue
COM
Red
NO
White
Yellow / green
Hazardous areas : 1, 2, 21, 22
-20 °C ≤ Ta ≤ +70 °C
Dust IP6x
Gases
T° surface
Class
Ta = 60 °C
80 °C
T6
Ta = 70 °C
95 °C
T5
Important: Maximum power dissipation in the case
must not exceed 5 W
2015-11-13
All necessary measures must be taken by the user, to avoid the calorific transfer from the fluid to the apparatus head increasing the head's temperature
to such that it reaches the self-ignition temperature of the gas in which it is used.
Design and specifications subject to change without notice
Yellow / green
www.baumer.com
Data sheet A32.22
Page 2 / 5
RDE4 - RDE8
Differential pressure switch, explosion proof
Micro switches characteristics
Switch code
A (B)
Type
M (K)
Standard
6 Vdc
Gold contact
10... 50 mA
C (W)
E (F)
D (V)
Hermetic
Ultra sensitive
Ultra sensitive
Hermetic
0.4... 10 A
5 mA ... 4 A
0.4... 1A
0.4... 4A
12 Vdc
0.4... 10 A
10... 50 mA
5 mA ... 4 A
0.4... 1A
0.4... 4A
24 Vdc
0.4... 6A
10... 50 mA
5 mA ... 4 A
0.4... 1A
0.4... 4A
0.4... 1A
0.4... 30 Vdc
0.4... 6A
10... 10 mA
5 mA ... 3 A
48 Vdc
0.4... 6A
10... 50 mA
5 mA ... 3 A
N/A
N/A
110 Vdc
0.1... 0.5 A
10... 50 mA
5 mA ... 1 A
N/A
N/A
220 Vdc
0.1... 0.25 A
10... 50 mA
5 mA ... 0.5 A
115 Vac
0.4... 10 A
10... 50 mA
50 mA ... 3 A
250 Vac
0.2... 10 A
10... 10 mA
Dielectric rigidity between contacts and ground
2000 V
2000 V
N/A
0.4... 2A
N/A
10 A
N/A
50 mA ... 2.5 A
0.2 ... 10 A
N/A
1500 V
2000 V
1000 V
Adjustable ranges
Scale
mbar
Micro-switch dead band (1)
Adjustable dead band
Code
A (B*)
M (K*)
Fixed dead band
C(W*)
E(F*)
10%
90%
10%
90%
10%
D (V*)
90%
10%
90%
mbar
bar
5
0.15
110
N/A
N/A
N/A
N/A
0.45
0.6
N/A
N/A
0.15
111
1.8 - 15
2.4 - 15
6.7 - 15
6.7 - 15
0.45
0.6
2.25
3
-2.5 ... 2.5
2 ... 10
Max P
Static
10
mbar
2 ... 50
50
0.15
121
2.6 - 45
3.3 - 45
7.5 - 45
7.5 - 45
0.6
0.75
3
4.5
2 ... 100
100
0.15
131
2.6 - 60
3.7 - 60
8.2 - 60
15 - 60
0.75
1.05
3
4.5
19.5
10 ... 200
200
1
156
12 - 120
15.5 - 120
37 - 120
60 - 120
3.75
5.1
15
10 ... 400
400
1
157
22 - 225
30 - 225
45 - 225
67 - 225
6.75
9
27
Code
bar
mbar
bar
36
bar
0.05... 0.5
0.5
7
211
0.13 - 0.45
0.15 - 0.45
0.22 - 0.6
0.3 - 0.6
37.5
45
0.17
0.18
0.05... 1
1
7
221
0.13 - 0.45
0.15 - 0.45
0.22 - 0.75
0.33 - 0.75
37.5
45
0.17
0.18
0.15... 0.5
0.5
30
214
0.22 - 0.75
0.27 - 0.75
N/A
N/A
82.5
90
0.26
0.33
0.36
0.15... 1
1
30
224
0.22 - 0.9
0.3 - 0.9
N/A
N/A
82.5
90
0.26
0.15... 4
4
30
234
0.22 - 2.2
0.37 - 2.2
0.97 - 3
1.2 - 3
82.5
97.5
0.26
0.4
235
1 - 3.7
1.6 - 3.7
1.12 - 3.7
1.6 - 3.7
105
150
1.26
2.03
4
4
30
0.8... 10
0.8... 10
30
245
1 - 3.7
1.6 - 3.7
1.12 - 3.7
1.6 - 3.7
105
150
1.26
2.03
1.5... 10
10
65
246
1.8 - 7.5
3.7 - 7.5
3.7 - 9
5.2 - 9
270
360
2.18
4.5
1.5... 20
20
65
256
1.8 - 7.5
3.7 - 7.5
3.7 - 9
5.2 - 9
270
360
2.18
4.5
2.5... 20
20
220
257
3.7 - 20
5.2 - 20
9 - 20
10 - 20
1200
1500
4.5
6.3
2.5... 30
30
220
258
4.5 - 30
6 - 30
9 - 30
10 - 30
1275
1500
5.4
7.2
(*) For version with 2 microswitches lower values of the dead band must be multiplied x 1.5
The value of the dead band is depending on the value of the set point.
This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For adjustable dead band the lower value corresponds to the
dead band spring totally released and the higher corresponds to the dead band spring fully tensed. For other set points the dead band value can be calculated by linear
interpolation between the values at 10% and 90%.
2015-11-13
(1)
Design and specifications subject to change without notice
Max
ΔP
www.baumer.com
Data sheet A32.22
Page 3 / 5
RDE4 - RDE8
Differential pressure switch, explosion proof
Dimensions (mm)
Set point adjustment
Differential adjustment
56
(3x) Ø 9 on Ø 222
86
20
Ø 194
12
0°
Weight: 4.4 kg
120°
116
RA
139
EE
x d II C T
0°
6
12
Cable gland
not mounted
121
Pressure range codes: 156 - 157
Weight: 1 kg
Pressure range codes: 110 - 111 - 121 - 131
Weight: 1.8 kg
LP
80
78
LP
Hex 24
HP
70
46.5
G 1/2(M)
Ø 220
Pressure range codes: 211 - 221
Weight: 1.6 kg
136
G 1/2(M)
Ø 146
56
HP
HP
86
Pressure range codes: 214 - 224 - 234 - 235 - 245 - 246 - 256 - 257 - 258
Weight: 1.2 kg
Design and specifications subject to change without notice
Hex 24
LP
89
70
HP
LP
Ø 65
27
70
G 1/2(M)
2015-11-13
G 1/2(M)
www.baumer.com
Data sheet A32.22
Page 4 / 5
RDE4 - RDE8
Differential pressure switch, explosion proof
Ordering details RDE4 - RDE8
RD E
Model
Differential pressure switch
Approvals
Explosion proof
Sensing element
Diaphragm (Viton®, range 110 to 157)
Bellow (stainless steel, range 211 to 258)
Type of micro switches
1 SPDT standard changeover switch
2 SPDT standard changeover switch
1 SPDT hermetically changeover switch
2 SPDT hermetically changeover switch
1 SPDT ultra sensitive changeover switch
2 SPDT ultra sensitive changeover switch
1 SPDT hermetically, ultra sensitive changeover switch
2 SPDT hermetically, ultra sensitive changeover switch
1 SPDT gold contact changeover switch
2 SPDT gold contact changeover switch
Process connection
G 1/2 male (standard)
1/2 NPT male
1/4 NPT female
.
–
xxx
/
RD
E
–
4
8
Deadband
Adjustable
Adjustable
Adjustable
Adjustable
Fix
Fix
Fix
Fix
Adjustable
Adjustable
A
B
C
W
E
F
D
V
M
K
3
6
8
.
Pressure range (mbar)
Pressure range (kPa)
-2.5 ...
2.5
-0.25 ...
0.25
2
...
10
0.2 ...
1
2
...
50
0.2 ...
5
2
...
100
0.2 ...
10
10
...
200
1
...
20
10
...
400
1
...
40
Pressure range (bar)
Pressure range (kPa)
0.05 ...
0.5
5 ...
50
0.05 ...
1
5 ...
100
0.15 ...
0.5
15 ...
50
0.15 ...
1
15 ...
100
0.15 ...
4
15 ...
400
0.8 ...
4
80 ...
400
0.8 ...
10
80 ... 1000
1.5 ...
10
150 ... 1000
1.5 ...
20
150 ... 2000
2.5 ...
20
250 ... 2000
2.5 ...
30
250 ... 3000
Options to be added behind the / (see example below)
110
111
121
131
156
157
211
221
214
224
234
235
245
246
256
257
258
/
RD
E
–
4
C
3
.
111
/
0407
_
9941
Differential pressure switch
With ATEX approval Explosion proof
Diaphragm Viton®
1 SPDT hermetically changeover switch
Process connection G 1/2 male
Pressure range 2 ... 10 mbar
Option: Mounting on 2" pipe
2015-11-13
Option: Stainless steel tag plate and wire
Design and specifications subject to change without notice
Ordering example with options
www.baumer.com
Data sheet A32.22
Page 5 / 5