APPLIKATION, RDY5, Baumer_RDY5_DS_EN_1512.pdf, 1.3 MB

RDY5
Differential pressure switch with intrinsic safety
for high static pressure
Main Features
„„
Excellent repeatability
„„
Dead band adjustment for regulation
„„
Fix dead band for control and alarm
„„
High static pressure up to 80 bar
„„
Intrinsic safety Hazardous area 0, 1, 2
Applications
„„Power generation safety equipment
„„Pressurized chambers control
„„Liquid level control
Technical Data
2 ... 10 mbar to 10 ... 2000 mbar
Temperature
Process: -15 ... +150 °C
Ambient: -25 ... + 55 °C
Storage: -40 ... + 70 °C
± 1% F.S. / constant pressure cycle
Repeatability
CE conformity
Low Voltage Directive LVD 2006/95/EC
ATEX Directive 94/9/EC
Protection rating
IP 66 (EN 60529)
Electrical
connection
Electrical function
Terminal block with plastic cable gland for
Ø 7 to 10.5 mm
Adjustment
2 external adjustment screws for set point and
dead band.
When set point adjustment is required it is necessary to know the static pressure, as it has an
influence on the set point.
ATEX
See ordering code details on page 5
Cover
Zamak blue painted
Captive stainless steel screws
Case
Black Zamak
Mounting
Wall mounting braket
Type examination certificate
LCIE 03 ATEX 6123X
EN 60079-0: 2012 (internal conformity analysis)
EN 60079-11: 2012
Marking
0081
IM1
Ex ia I Ma
II 1 G
Ex ia IIC T6 or T5 Ga
Electrical data
Umax = 28 Vdc
Imax = 120 mA
Pmax = 0.84 W
Ground connection
Via internal terminal block
Ci = Negligible ; Li = Negligible
Process connection Stainless steel 1.4404 (316L)
Sensing element
Scale
Pressure range codes 111 to 131
Flanges:Stainless steel 1.4404 (316L)
Diaphragm: Nitrile Butyl rubber
Pressure range codes 156 to 163
Flanges:Stainless steel 1.4404 (316L)
Diaphragm:Viton®
Internal. Accuracy on reading ± 5% F.S.
Options
Code SETP
Oxygen application
Code 0765
Mounting on 2" pipe
Code 0407
Electrical connection: stainless steel connector (Souriau)
Code 2298
Mobile plug for stainless steel connector (Souriau)
Code 2249
Stainless steel tag plate and wire
Code 9941
Lead seal of the adjustment screws
Code 8990
2015-11-13
Customer specific set point adjustment
Design and specifications subject to change without notice
Pressure range
www.baumer.com
Data sheet A32.41
Page 1 / 5
RDY5
Differential pressure switch with intrinsic safety
for high static pressure
Principle
∆P
A flexible sensing element actuates a microswitch by means of a
piston. The set point is adjusted by means of a compressible spring
installed in opposition.
NC
NC
NC
C
C
C
NO
NO
HP < LP
NO
HP > LP
Set point and reset point must be between 10% and 90% of the selected
scale.
Standard factory adjustment
Setpoint at 50% of the scale on falling pressure
NC
C
NC
NC
C
C
NO
NO
NO
Customer speciffic factory adjustment (option SETP)
The following specifications have to be given with the order:
• Setpoint value
• Adjustment on falling or raising pressure.
• Static pressure
• Dead band value (as needed) when using an adjustable dead band
switch
Electrical connections
2 SPDT
1 SPDT
NC
Blue
COM
Red
NO
White
NC
Blue
COM
Red
NO
White
NC
Blue
COM
Red
Yellow / green
NO
White
Yellow / green
Certified safety
barrier
NO
C
Non hazardous
area
NO
or NC
NC
+
Rc 1
Supply
–
Screen
For max. ambient temperature refer to technical data on page 1.
The installation must be made in an intrinsically safe circuit whose certified electrical safety parameters do not exceed any of the values Umax,
Imax and Pmax given in the electrical data on page 1.
2015-11-13
All necessary measures must be taken by the user, to avoid the calorific transfer from the fluid to the apparatus head increasing the head's
temperature to such that it reaches the self-ignition temperature of the gas in which it is used.
Design and specifications subject to change without notice
Hazardous area
Zone 0, 1, 2
www.baumer.com
Data sheet A32.41
Page 2 / 5
RDY5
Differential pressure switch with intrinsic safety
for high static pressure
Micro switches characteristics
Switch code
M (K)
C (W)
S
Type
Gold contact
Hermetic
Ultrasensitive
Gold contact
6 Vdc
10 ... 50 mA
5 ... 120 mA
10 ... 50 mA
12 Vdc
10 ... 50 mA
5 ... 66 mA
10 ... 50 mA
24 Vdc
10 ... 33 mA
5 ... 33 mA
10 ... 33 mA
30 Vdc
N/A
N/A
N/A
48 Vdc
N/A
N/A
N/A
110 Vdc
N/A
N/A
N/A
220 Vdc
N/A
N/A
N/A
115 Vac
N/A
N/A
N/A
250 Vac
Dielectric rigidity between contacts and ground
N/A
N/A
N/A
2000 V
1500 V
2000 V
Adjustable ranges
Scale
Max
ΔP
Max P
Static
Micro-switch dead band (1)
Adjustable dead band
Code
M (K*)
Fixed dead band
C(W*)
10%
90%
10%
S
90%
10%
90%
mbar
mbar
bar
2 ... 10
10
0... 5
111
1.2 - 10
1.6 - 10
4.5 - 10
4.5 - 10
0.7
1.2
1.7 - 20
2.2 - 20
5 - 20
5.5 - 20
0.9
1.4
mbar
2 ... 20
50
0... 5
112
2 ... 50
50
0... 5
121
1.7 - 30
2.2 - 30
5 - 30
5.5 - 30
0.9
1.4
2 ... 100
100
0... 5
131
1.7 - 40
2.5 - 40
5.5 - 40
10 - 40
1.2
2
10 ... 200
200
5.5... 50
156
8 - 80
10.5 - 80
35 - 80
45 - 80
5.8
9.5
10 ... 400
400
5.5... 50
157
15 - 150
20 - 150
40 - 150
50 - 150
10.5
17
10 ... 1000
1000
5.5... 50
158
18 - 150
22 - 150
45 - 150
60 - 150
11.5
19.6
10 ... 700
700
5.5... 80
161**
20 - 200
30 - 200
60 - 350
90 - 350
18.5
22.5
10 ... 1500
1500
5.5... 80
162**
20 - 300
30 - 300
60 - 350
100 - 350
18.5
22.5
10 ... 2000
2000
5.5... 80
163**
30 - 300
60 - 300
90 - 350
200 - 350
20.7
33.6
(*) For version with 2 microswitches lower values of the dead band must be multiplied x 1.5
(**) G1/4 female only
The value of the dead band is depending on the value of the set point.
This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For adjustable dead band the lower value corresponds to the
dead band spring totally released and the higher corresponds to the dead band spring fully tensed. For other set points the dead band value can be calculated by linear
interpolation between the values at 10% and 90%.
2015-11-13
Design and specifications subject to change without notice
(1)
www.baumer.com
Data sheet A32.41
Page 3 / 5
RDY5
Differential pressure switch with intrinsic safety
for high static pressure
Dimensions (mm)
125
76.5
144
5
64
100
45°
76.5
130
Pressure range codes: 111 - 121 - 131
Weight: 10 kg
Pressure range codes: 156 - 157 - 158
Weight: 6.4 kg
48
G1/2(M)
LP
Hex 24
Ø 148
HP
83
94
Hex 24
Ø 260
56
LP
88
G 1/2(M)
=
139
=
58
130
Hex 24
Hex 24
HP
G 1/2(M)
130
G1/2(M)
76.5
95
28.5
Design and specifications subject to change without notice
Pressure range codes: 161-162-163
Weight: 7 kg
97
LP
36
HP
Ø120
2015-11-13
2 holes G 1/4 (F)
Hex 24
www.baumer.com
Data sheet A32.41
Page 4 / 5
RDY5
Differential pressure switch with intrinsic safety
for high static pressure
Ordering details RDY5
RD
Model
Differential pressure switch
Approvals
ATEX intrinsic safety
Y
5
.
xxx
/
RD
Y
Sensing element
Diaphragm (Nitrile Butyl rubber, ranges 111 to 131, Viton ®, ranges 156 to 163)
Type of micro switches
Deadband
1 SPDT hermetically changeover switch
Adjustable
2 SPDT hermetically changeover switch
Adjustable
1 SPDT gold contact changeover switch
Adjustable
2 SPDT gold contact changeover switch
Adjustable
1 SPDT ultrasensitive gold contact changeover switch
Fix
Process connection
G 1/4 female (only pressure ranges 161, 162, 163)
G 1/2 male (standard)
1/2 NPT male
1/4 NPT female
Pressure range (mbar)
Pressure range (kPa)
2
...
10
0.2 ...
1
2
...
20
0.2 ...
2
2
...
50
0.2 ...
5
2
... 100
0.2 ...
10
10
...
200
1
...
20
10
...
400
1
...
40
10
... 1000
1
...
100
10
...
700
1
...
70
10
... 1500
1
...
150
10
... 2000
1
...
200
Options to be added behind the / (see example below)
–
–
5
C
W
M
K
S
H
3
6
8
.
111
112
121
131
156
157
158
161
162
163
Process connection G1/4 female
Process connection G1/4 female
Process connection G1/4 female
/
Ordering example with options
RD
Y
–
5
C
3
.
111
/
0407
_
9941
Differential pressure switch
With ATEX approval intrinsic safety
Sensing element diaphragm
1 SPDT hermetically changeover switch
Process connection G 1/2 male
Pressure range 2 ... 10 mbar
Design and specifications subject to change without notice
Option: Mounting on 2" pipe
2015-11-13
Option: Stainless steel tag plate and wire
www.baumer.com
Data sheet A32.41